Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Skeletal Radiol ; 51(1): 89-99, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34550397

RESUMO

Five MRI patterns of marrow involvement (diffuse, focal, combined diffuse and focal, variegated, and normal) are observed in patients with a marrow proliferative disorder including MM. The wide range of marrow involvement patterns in monoclonal plasma cell proliferative disorders mirrors that of their natural histories that can vary from indolent to rapidly lethal. MRI of the axial bone marrow contributes to stage these disorders, but it should not be obtained for disease detection and characterization because of its limited specificity and sensitivity. At MRI, diffuse benign hematopoietic marrow hyperplasia and marrow heterogeneities in elderly patients mimic the diffuse and variegated patterns observed in MM patients. Careful analysis of fat- and fluid-sensitive MR images and quantitative marrow assessment by using MRI and FDG-PET can contribute in differentiating these changes from those associated with neoplastic marrow infiltration, with some residual overlapping findings.


Assuntos
Doenças da Medula Óssea , Mieloma Múltiplo , Idoso , Medula Óssea/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Mieloma Múltiplo/diagnóstico por imagem , Tomografia por Emissão de Pósitrons
2.
Bone ; 182: 117073, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38493932

RESUMO

INTRODUCTION: Massive bone allografts enable the reconstruction of critical bone defects in numerous conditions (e.g. tumoral, infection or trauma). Unfortunately, their biological integration remains insufficient and the reconstruction may suffer from several postoperative complications. Perfusion-decellularization emerges as a tissue engineering potential solution to enhance osseointegration. Therefore, an intrinsic vascular study of this novel tissue engineering tool becomes essential to understand its efficacy and applicability. MATERIAL AND METHODS: 32 porcine long bones (humeri and femurs) were used to assess the quality of their vascular network prior and after undergoing a perfusion-decellularization protocol. 12 paired bones were used to assess the vascular matrix prior (N = 6) and after our protocol (N = 6) by immunohistochemistry. Collagen IV, Von Willebrand factor and CD31 were targeted then quantified. The medullary macroscopic vascular network was evaluated with 12 bones: 6 were decellularized and the other 6 were, as control, not treated. All 12 underwent a contrast-agent injection through the nutrient artery prior an angio CT-scan acquisition. The images were processed and the length of medullary vessels filled with contrast agent were measured on angiographic cT images obtained in control and decellularized bones by 4 independent observers to evaluate the vascular network preservation. The microscopic cortical vascular network was evaluated on 8 bones: 4 control and 4 decellularized. After injection of gelatinous fluorochrome mixture (calcein green), non-decalcified fluoroscopic microscopy was performed in order to assess the perfusion quality of cortical vascular lacunae. RESULTS: The continuity of the microscopic vascular network was assessed with Collagen IV immunohistochemistry (p-value = 0.805) while the decellularization quality was observed through CD31 and Von Willebrand factor immunohistochemistry (p-values <0.001). The macroscopic vascular network was severely impaired after perfusion-decellularization; nutrient arteries were still patent but the amount of medullary vascular channels measured was significantly higher in the control group compared to the decellularized group (p-value <0.001). On average, the observers show good agreement on these results, except in the decellularized group where more inter-observer discrepancies were observed. The microscopic vascular network was observed with green fluoroscopic signal in almost every canals and lacunae of the bone cortices, in three different bone locations (proximal metaphysis, diaphysis and distal metaphysis). CONCLUSION: Despite the aggressiveness of the decellularization protocol on medullary vessels, total porcine long bones decellularized by perfusion retain an acellular cortical microvascular network. By injection through the intact nutrient arteries, this latter vascular network can still be used as a total bone infusion access for bone tissue engineering in order to enhance massive bone allografts prior implantation.


Assuntos
Engenharia Tecidual , Fator de von Willebrand , Suínos , Animais , Engenharia Tecidual/métodos , Fator de von Willebrand/análise , Osso e Ossos , Artérias , Colágeno , Alicerces Teciduais/química , Matriz Extracelular
3.
Prog Urol ; 23(10): 906-8, 2013 Sep.
Artigo em Francês | MEDLINE | ID: mdl-24034804

RESUMO

Hematuria is one of the most frequent minor complications after prostatic biopsy. We would like to report the case of a 68-year-old patient with massive hematuria after prostatic biopsy and intravesical active prostate bleeding diagnosed in B-mode ultrasonography.


Assuntos
Biópsia por Agulha/efeitos adversos , Hematúria/etiologia , Hemorragia/diagnóstico por imagem , Próstata/diagnóstico por imagem , Doenças Prostáticas/diagnóstico por imagem , Idoso , Hematúria/diagnóstico por imagem , Hemorragia/etiologia , Humanos , Masculino , Próstata/patologia , Doenças Prostáticas/etiologia , Ultrassonografia de Intervenção
5.
Diagn Interv Imaging ; 102(3): 171-180, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32830083

RESUMO

PURPOSE: To investigate the diagnostic performance of sacroiliac joint (SIJ) magnetic resonance imaging (MRI) and the incremental value of spine MRI to "predict" clinical disease activity in patients with axial spondyloarthritis (axSpA). MATERIALS AND METHODS: This cross-sectional study included adult patients with known axSpA according to the SpondyloArthritis International Society (ASAS) classification criteria, radiological arm. MRI disease activity was scored semi-quantitatively for SIJ and total spine MRI in each patient. Two cut-off levels (≥ 1.3 and ≥ 2.1) for ankylosing spondylitis disease activity score with C-reactive protein (ASDAS-CRP) were considered for clinical disease activity categorization. MRI scores were first evaluated individually. Then, SIJ score was combined with the score from a spine segment (lumbar, cervical, thoracic or total spine) to build a bi-parametric model using a classification tree. Receiver operating characteristic (ROC) curves were constructed to evaluate the classification performance according to disease activity category of these models. RESULTS: Forty-four patients (30 men, 14 women; mean age, 37 years±10 [SD] [range: 17-64 years]) with a mean disease duration of 5 years±8 (SD) (range: 0-35 years) were included. Thirty-six patients (36/44; 82%) had ASDAS-CRP≥1.3 and 27 patients (27/44; 61%) had ASDAS-CRP≥2.1. The most frequently involved spinal segment was mid-thoracic (T7-T8). The SIJ MRI score was an informative model to identify active axSpA (AUC≥0.7, regardless of the cut-off level on ASDAS-CRP). Performance of bi-parametric models based on "SIJ+thoracic spine" (for detecting patients with ASDAS-CRP≥1.3) or "SIJ+total spine" (for detecting patients with ASDAS-CRP≥2.1) outperformed that of the individual SIJ score (P<0.05). CONCLUSION: The combination of MRI of the SIJ and spine allows to accurately discriminate between active and inactive axSpA, outperforming SIJ MRI alone.


Assuntos
Articulação Sacroilíaca , Espondilartrite , Espondilite Anquilosante , Adulto , Estudos Transversais , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Articulação Sacroilíaca/diagnóstico por imagem , Articulação Sacroilíaca/patologia , Índice de Gravidade de Doença , Coluna Vertebral/diagnóstico por imagem , Espondilartrite/diagnóstico por imagem , Espondilite Anquilosante/patologia
6.
Diagn Interv Imaging ; 100(3): 169-175, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30573350

RESUMO

PURPOSE: To compare the diagnostic performance of T2-weighted Dixon, T1-weighted and Short-Tau Inversion Recovery (STIR) MR images for the detection of radiographically occult fractures (ROF) of the hip and pelvis in elderly patients after low-energy trauma. MATERIALS AND METHODS: A total of 22 patients older than 50 years with suspected ROF after low-energy trauma was prospectively included. There were 9 men and 13 women, with a mean age of 80.9 years±12.5 (SD) (range: 52-100 years). T2-weighted Dixon, T1-weighted and STIR MR images were analyzed by 3 independent radiologists blinded to the clinical data and the results of other imaging examinations. Readers separately assessed each series of images for the presence of fractures on a per bone analysis. Diagnostic performance of each reader was compared for Dixon and non-Dixon sequences using contingency tables and McNemar test. Interobserver agreement was evaluated according to the Fleiss-Cuzick's kappa statistics. RESULTS: The sensitivity of the Dixon sequence in the detection of ROF ranged from 90.9% (20/22; 95% CI: 70.8-98.9%) to 100% (22/22; 95% CI: 84.6-100%). The sensitivities of the non-Dixon sequences in the detection of ROF ranged from 95.5% (21/22; 95% CI: 77.2-99.9%) to 100% (22/22; 95% CI: 84.6-100%). For each reader, there were no statistical differences between combined Dixon and combined non-Dixon images for the detection of ROF (P=0.12, 0.99 and 0.99). Interobserver agreement with T2-weighted Dixon water-only images was significantly lower than that with the STIR sequence (0.70-0.79 vs. 0.87-0.93). CONCLUSION: T2-weighted Dixon may be a second-rate alternative to T1-weighted and STIR sequences for the detection of ROF of the hip and pelvis in elderly patients.


Assuntos
Fraturas Fechadas/diagnóstico por imagem , Fraturas do Quadril/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ossos Pélvicos/lesões , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ossos Pélvicos/diagnóstico por imagem , Sensibilidade e Especificidade
7.
Diagn Interv Imaging ; 99(1): 23-28, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29054404

RESUMO

PURPOSE: To compare the effectiveness of fat suppression and the image quality of the Dixon method with those of the chemical shift-selective (CHESS) technique in hands of normal subjects at non-enhanced three-dimensional (3D) T1-weighted MR imaging. MATERIALS AND METHODS: Both hands of 14 healthy volunteers were imaged with 3D fast spoiled gradient echo (FSPGR) T1-weighted Dixon, 3D FSPGR T1-weighted CHESS and 3D T1-weighted fast spin echo (FSE) CHESS sequences in a 1.5T MR scanner. Three radiologists scored the effectiveness of fat suppression in bone marrow (EFSBM) and soft tissues (EFSST) in 20 joints per subject. One radiologist measured the signal-to-noise ratio (SNR) in 10 bones per subject. Statistical analysis used two-way ANOVA with random effects (P<0.0083), paired t-test (P<0.05) and observed agreement to assess differences in effectiveness of fat suppression, differences in SNR and interobserver agreement. RESULTS: EFSBM was statistically significantly higher for the 3D FSPGR T1-weighted Dixon than for the 3D FSPGR T1-weighted CHESS sequence and the 3D FSE T1-weighted CHESS sequence (P<0.0001). EFSST was statistically significantly higher for the 3D FSPGR T1-weighted Dixon than for the 3D FSPGR T1-weighted CHESS sequence (P<0.0011) and for the 3D FSE T1-weighted CHESS sequence in the axial plane (P=0.0028). Mean SNR was statistically significantly higher for 3D FSPGR T1-weighted Dixon sequence than for 3D FSPGR T1-weighted CHESS and 3D FSE T1-weighted CHESS sequences (P<0.0001). CONCLUSION: The Dixon method yields more effective fat suppression and higher SNR than the CHESS technique at 3D T1-weighted MR imaging of the hands.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Mãos/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Adulto , Artefatos , Medula Óssea/diagnóstico por imagem , Feminino , Voluntários Saudáveis , Humanos , Masculino
9.
Diagn Interv Imaging ; 99(2): 55-64, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29396088

RESUMO

This article characterizes common meniscal pathologies, reviews magnetic resonance imaging (MRI) diagnostic criteria for meniscal tears, and identifies difficult-to-detect tears and fragments and the best MRI sequences and practices for recognizing these lesions. These difficult-to-diagnose meniscal lesions that radiologists should consider include tears, meniscocapsular separation lesions, and displaced meniscal fragments. Meniscus tears are either vertical, which are generally associated with traumatic injury, horizontal, which are associated with degenerative injury, or combinations of both. MRI has a high sensitivity for tears but not for fragments; MRI performance is also better for medial than lateral meniscal lesions. Fragment detection can be improved by recognizing signs secondary to migration, especially signs of epiphyseal irritation and mechanical impingement. Radial and peripheral tears, as well as those close to the posterior horn insertion, have been traditionally difficult to detect, but improvements in arthroscopic knowledge, identification of common lesion patterns, and selection of the proper MRI sequence and plane for each lesion type mean that, when properly used, MRI is an invaluable tool in detecting all types of meniscal tears.


Assuntos
Imageamento por Ressonância Magnética , Lesões do Menisco Tibial/diagnóstico por imagem , Humanos , Articulação do Joelho/diagnóstico por imagem
10.
Diagn Interv Imaging ; 97(2): 233-8, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26025159

RESUMO

PURPOSE: Cardiac perforations due to pacing and implantable defibrillator lead displacement are rare and their detection may be difficult. The goal of this study was to review the clinical and imaging presentation of cardiac perforation related to pacing lead displacement. PATIENTS AND METHODS: The clinical and imaging files of four patients (two men and two women) who experienced cardiac perforation related to pacing lead displacement were reviewed. The four patients were investigated in our radiology department over a 24-month-period. RESULTS: Two patients had clinical symptoms at the time lead displacement was detected and the other two were free of symptoms. In all patients, lead displacement was visible on imaging examinations in retrospect but was not detected prospectively. CONCLUSION: Radiologists should pay attention to the position of the tips of the leads on chest X-ray and CT, even late after the implantation and in asymptomatic patients.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Falha de Equipamento , Traumatismos Cardíacos/etiologia , Marca-Passo Artificial/efeitos adversos , Falha de Prótese , Adulto , Idoso , Feminino , Humanos , Doença Iatrogênica , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
11.
Diagn Interv Imaging ; 96(4): 341-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25746223

RESUMO

Eosinophilic fasciitis is a rare condition. It is generally limited to the distal parts of the arms and legs. MRI is the ideal imaging modality for diagnosing and monitoring this condition. MRI findings typically evidence only fascial involvement but on a less regular basis signal abnormalities may be observed in neighboring muscle tissue and hypodermic fat. Differential diagnosis of eosinophilic fasciitis by MRI requires the exclusion of several other superficial and deep soft tissue disorders.


Assuntos
Eosinofilia/diagnóstico , Fasciite/diagnóstico , Imageamento por Ressonância Magnética , Diagnóstico Diferencial , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA