1.
Artigo em Inglês | MEDLINE | ID: mdl-39224002

RESUMO

Coronary obstruction (CO) is a potential pitfall for transcatheter aortic valve replacement (TAVR), especially in valve in valve procedures into degenerated surgical or transcatheter prostheses. Bioprosthetic leaflet modification techniques that incorporate electrosurgery are evolving as the preferred strategy to mitigate the risk of CO in high CO risk settings. The UNICORN method is proposed as a more predictable leaflet modification strategy than the earlier described BASILICA approach, but its proponents have hitherto mandated the use of a balloon-expandable valve (BEV) prosthesis. Many patients have small prostheses and therein face a significant risk of patient prosthesis mismatch with BEV in this setting. This risk may be curtailed if a self-expanding valve (SEV) prosthesis could be used. Herein described is a modified approach to allow for the utilization of SEV systems in this setting.

2.
Heart Lung Circ ; 33(3): 324-331, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38184427

RESUMO

BACKGROUND: The Navitor (Abbott Inc, IL, USA) transcatheter heart valve is a novel third-generation self-expanding bioprosthesis with specific features to mitigate paravalvular regurgitation (PVR). Owing to its novelty, there is a paucity of data on its application in clinical practice. METHODS: Consecutive cohort analysis of the use of the Navitor system in an as-treated clinical setting at a quaternary heart hospital. RESULTS: Sixty consecutive non-clinical trial patients treated with Navitor were identified. All patients underwent a successful procedure. The mean age was 79.3 years (±SD 7.82), 56.67% (n=34) were female, and the mean STS score was 4.87 (±SD 5.70). At 30 days post-procedure, all patients were alive with no readmissions for heart failure. One patient had a major vascular complication (1.7%). Four patients (7.14% of patients without a pre-existing pacemaker) received a new permanent pacemaker. Two patients (3.4%) had a non-disabling stroke. PVR at 30 days was trivial or none in 75% of patients, and no patient had worse than mild PVR. CONCLUSIONS: The Navitor system in this as-treated cohort was associated with favourable clinical, haemodynamic, and safety outcomes.


Assuntos
Valvopatia Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Valvopatia Aórtica/etiologia , Desenho de Prótese , Fatores de Risco