1.
J Radiol Prot ; 34(3): 509-28, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24938591

RESUMO

Monte Carlo calculations were used to investigate the efficiency of radiation protection equipment in reducing eye and whole body doses during fluoroscopically guided interventional procedures. Eye lens doses were determined considering different models of eyewear with various shapes, sizes and lead thickness. The origin of scattered radiation reaching the eyes was also assessed to explain the variation in the protection efficiency of the different eyewear models with exposure conditions. The work also investigates the variation of eye and whole body doses with ceiling-suspended shields of various shapes and positioning. For all simulations, a broad spectrum of configurations typical for most interventional procedures was considered. Calculations showed that 'wrap around' glasses are the most efficient eyewear models reducing, on average, the dose by 74% and 21% for the left and right eyes respectively. The air gap between the glasses and the eyes was found to be the primary source of scattered radiation reaching the eyes. The ceiling-suspended screens were more efficient when positioned close to the patient's skin and to the x-ray field. With the use of such shields, the Hp(10) values recorded at the collar, chest and waist level and the Hp(3) values for both eyes were reduced on average by 47%, 37%, 20% and 56% respectively. Finally, simulations proved that beam quality and lead thickness have little influence on eye dose while beam projection, the position and head orientation of the operator as well as the distance between the image detector and the patient are key parameters affecting eye and whole body doses.


Assuntos
Imagens de Fantasmas , Proteção Radiológica/instrumentação , Radiologia Intervencionista , Dispositivos de Proteção dos Olhos , Cristalino , Método de Monte Carlo , Radiometria , Contagem Corporal Total
2.
Phys Med ; 54: 42-48, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30337009

RESUMO

Interventional cardiac procedures may be associated with high patient doses and therefore require special attention to protect the patients from radiation injuries such as skin erythema, cardiovascular tissue reactions or radiation-induced cancer. In this study, patient exposure data is collected from 13 countries (37 clinics and nearly 50 interventional rooms) and for 10 different procedures. Dose data was collected from a total of 14,922 interventional cardiology procedures. Based on these data European diagnostic reference levels (DRL) for air kerma-area product are suggested for coronary angiography (CA, DRL = 35 Gy cm2), percutaneous coronary intervention (PCI, 85 Gy cm2), transcatheter aortic valve implantation (TAVI, 130 Gy cm2), electrophysiological procedures (12 Gy cm2) and pacemaker implantations. Pacemaker implantations were further divided into single-chamber (2.5 Gy cm2) and dual chamber (3.5 Gy cm2) procedures and implantations of cardiac resynchronization therapy pacemaker (18 Gy cm2). Results show that relatively new techniques such as TAVI and treatment of chronic total occlusion (CTO) often produce relatively high doses, and thus emphasises the need for use of an optimization tool such as DRL to assist in reducing patient exposure. The generic DRL presented here facilitate comparison of patient exposure in interventional cardiology.


Assuntos
Cardiologia/normas , Europa (Continente) , Valores de Referência
3.
Health Phys ; 115(4): 474-489, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30148813

RESUMO

A regulatory authority for radiation safety should continuously evaluate and improve the national safety framework, in line with current requirements and standards. In this context, the Greek Atomic Energy Commission initiated a series of concerted actions. The radiation dose to the population due to public and medical exposures was assessed. The assessment of dose due to public exposure was based on measurements of radon concentrations in dwellings, radionuclide concentrations in environmental samples, and air dose rates; the assessment of dose due to medical exposure was based on dose measurements for typical examinations or procedures and data on their frequency. The mean effective dose to a member of the population was found to be 4.5 mSv (1.8 mSv and 2.7 mSv from medical and public exposures, respectively). Regarding occupational exposure, aircrew dose assessment, eye lens monitoring, and the national dose registry were significantly improved. With respect to artificial tanning (sun beds), the ultraviolet radiation produced was assessed and the practices followed were observed. Results demonstrated exceedance of the 0.3 W m erythema effective irradiance limit set in European Union standards by 63.5% of the sun beds measured, along with general noncompliance with standards. An overarching activity was the upgrade of the Greek Atomic Energy Commission information system in order to collect and disseminate radiation data electronically, launch a networking strategy for interaction with stakeholders, and facilitate the process of regulatory control. In response to the above findings, regulatory actions have been initiated.


Assuntos
Exposição Ocupacional/análise , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Proteção Radiológica/normas , Banho de Sol , Materiais de Construção , Água Potável , Grécia , Humanos , Cristalino/efeitos da radiação , Doses de Radiação , Radioisótopos , Radônio/análise , Inquéritos e Questionários , Raios Ultravioleta , Poluentes Radioativos da Água
4.
Radiat Prot Dosimetry ; 165(1-4): 111-4, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25836684

RESUMO

The purpose of the present study was to present the national diagnostic reference levels (DRL) established for panoramic dental examinations in Greece. The establishment of DRL, as a tool for the optimisation of radiological procedures, is a requirement of national regulations. Measurements performed by the Greek Atomic Energy Commission on 90 panoramic systems have been used for the derivation of DRL values. DRL values have been proposed for exposure settings of different patient types (child, small adult and standard adult), both for film and digital imaging. The DRLs for different patient types are grouped in three categories: children, small adults (corresponding to female) and average adults (corresponding to male). Proposed DRLs for these groups are 2.2, 3.3 and 4.1 mGy, respectively. In order to investigate the correlation of DRLs with the available imaging modalities (CR, DR and film), this parameter was taken into account. DR imaging DRL is the lowest at 3.5 mGy, CR imaging the highest at 4.2 mGy and film imaging at 3.7 mGy. In order to facilitate comparison with other studies, kerma-width product values were calculated from Ki, air and field size.


Assuntos
Radiografia Dentária/normas , Radiografia Panorâmica/normas , Adulto , Ar , Criança , Bases de Dados Factuais , Feminino , Dosimetria Fotográfica/instrumentação , Dosimetria Fotográfica/métodos , Grécia , Humanos , Masculino , Imagens de Fantasmas , Doses de Radiação , Proteção Radiológica/métodos , Intensificação de Imagem Radiográfica/métodos , Intensificação de Imagem Radiográfica/normas , Radiografia Dentária/métodos , Radiografia Panorâmica/métodos , Radiometria , Valores de Referência , Raios X
5.
Radiat Prot Dosimetry ; 164(1-2): 84-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25316910

RESUMO

In preparation of a large European epidemiological study on the relation between eye lens dose and the occurrence of lens opacities, the European ELDO project focused on the development of practical methods to estimate retrospectively cumulative eye lens dose for interventional medical professionals exposed to radiation. The present paper applies one of the ELDO approaches, correlating eye lens dose to whole-body doses, to assess cumulative eye lens dose for 14 different Finnish interventional cardiologists for whom annual whole-body dose records were available for their entire working period. The estimated cumulative left and right eye lens dose ranged from 8 to 264 mSv and 6 to 225 mSv, respectively. In addition, calculations showed annual eye lens doses sometimes exceeding the new ICRP annual limit of 20 mSv. The work also highlights the large uncertainties associated with the application of such an approach proving the need for dedicated dosimetry systems in the routine monitoring of the eye lens dose.


Assuntos
Cateterismo Cardíaco/métodos , Cristalino/efeitos da radiação , Proteção Radiológica/métodos , Radiografia Intervencionista/métodos , Radiometria/métodos , Algoritmos , Cateterismo Cardíaco/efeitos adversos , Simulação por Computador , Humanos , Cristalino/lesões , Modelos Biológicos , Doses de Radiação , Radiografia Intervencionista/efeitos adversos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Radiat Prot Dosimetry ; 163(3): 319-24, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24891405

RESUMO

The purpose of this study is to present a national survey that was performed in Greece for the establishment of national Dose Reference Levels (DRLs) for seven common adult Computed Tomography (CT) examinations. Volumetric computed tomography dose index and dose-length product values were collected from the post-data page of 65 'modern' systems that incorporate tube current modulation. Moreover, phantom dose measurements on 26 'older' systems were performed. Finally, the effective dose to the patient from a typical acquisition during these examinations was estimated. The suggested national DRLs are generally comparable with respective published values from similar European studies, with the exception of sinuses CT, which presents significantly higher values. This fact, along with the large variation of the systems' dose values that were observed even for scanners of the same type, indicates a need for further patient protection optimisation without compromising the clinical outcome.


Assuntos
Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Tomografia Computadorizada de Feixe Cônico/normas , Exposição Ambiental/análise , Exposição Ambiental/normas , Contagem Corporal Total/estatística & dados numéricos , Contagem Corporal Total/normas , Adulto , Carga Corporal (Radioterapia) , Tomografia Computadorizada de Feixe Cônico/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento/normas , Grécia , Guias como Assunto , Humanos , Masculino , Imagens de Fantasmas/normas , Doses de Radiação , Proteção Radiológica/normas , Proteção Radiológica/estatística & dados numéricos , Valores de Referência
7.
Radiat Prot Dosimetry ; 156(4): 455-7, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23615358

RESUMO

Diagnostic reference levels (DRLs) is a tool for the optimisation of radiological procedures. Establishment of a DRL is a requirement of national regulations. Measurements performed by the Greek Atomic Energy Commission on 529 dental intraoral radiographic facilities have been used in order to define DRLs for digital and film imaging modalities, taking into account the region of the mouth to be imaged. Thus, different DRL values have been proposed for minimum (usually incisors), maximum (usually maxillary molars) and average exposure settings, both for film and digital imaging. The results have been compared with similar studies performed in Europe and the USA and are in line with the most recent ones.


Assuntos
Proteção Radiológica/métodos , Radiografia Dentária/normas , Padrões de Referência , Dosimetria Fotográfica/instrumentação , Dosimetria Fotográfica/normas , Grécia , Humanos , Mandíbula/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Garantia da Qualidade dos Cuidados de Saúde/normas , Doses de Radiação , Radiografia Dentária Digital/normas , Radiometria/instrumentação , Radiometria/normas
8.
Radiat Prot Dosimetry ; 157(4): 561-9, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23858492

RESUMO

This paper presents the dosimetry part of the European ELDO project, funded by the DoReMi Network of Excellence, in which a method was developed to estimate cumulative eye lens doses for past practices based on personal dose equivalent values, H(p)(10), measured above the lead apron at several positions at the collar, chest and waist levels. Measurement campaigns on anthropomorphic phantoms were carried out in typical interventional settings considering different tube projections and configurations, beam energies and filtration, operator positions and access routes and using both mono-tube and biplane X-ray systems. Measurements showed that eye lens dose correlates best with H(p)(10) measured on the left side of the phantom at the level of the collar, although this correlation implicates high spreads (41 %). Nonetheless, for retrospective dose assessment, H(p)(10) records are often the only option for eye dose estimates and the typically used chest left whole-body dose measurement remains useful.


Assuntos
Cardiologia/métodos , Cristalino/efeitos da radiação , Exposição Ocupacional , Proteção Radiológica/métodos , Radiologia Intervencionista/métodos , Antropometria , Simulação por Computador , Desenho de Equipamento , Humanos , Chumbo , Método de Monte Carlo , Imagens de Fantasmas , Radiometria/métodos , Reprodutibilidade dos Testes , Raios X
9.
Radiat Prot Dosimetry ; 150(3): 306-11, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22234422

RESUMO

Radiation exposure of the operator during cardiac catheter ablation procedures was assessed for an experienced cardiologist adopting various measures of radiation protection and utilised electroanatomic navigation. Chip thermoluminescent dosemeters were placed at the eyes, chest, wrists and legs of the operator. The ranges of fluoroscopy time and air kerma area product values associated with cardiac ablation procedures were wide (6.3-48.3 min and 1.7-80.3 Gy cm(2), respectively). The measured median radiation doses per procedure for each monitored position were 23.6 and 21.3 µSv to the left and right wrists, respectively, 25.3 and 30.4 µSv to the left and right legs, respectively. The doses to the eyes were below the minimum detectable dose of 9 µSv. The estimated median effective dose was 22.5 µSv. Considering the actual workload of the operator, the calculated annual doses to the hands, legs and eyes, as well as the annual effective dose, were all below the corresponding limits. The findings of this study indicate that cardiac ablation procedures performed at a modern laboratory do not impose a high radiation hazard to the operator when radiation protection measures are routinely adopted.


Assuntos
Arritmias Cardíacas/terapia , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Exposição Ocupacional/prevenção & controle , Proteção Radiológica , Adulto , Idoso , Ablação por Cateter/normas , Técnicas Eletrofisiológicas Cardíacas/normas , Olho/efeitos da radiação , Feminino , Fluoroscopia , Humanos , Perna (Membro)/efeitos da radiação , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/análise , Radiografia Intervencionista , Dosimetria Termoluminescente , Tórax/efeitos da radiação , Punho/efeitos da radiação , Adulto Jovem
10.
Radiat Prot Dosimetry ; 144(1-4): 492-6, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21212075

RESUMO

There are many factors that can influence the extremity and eye lens doses of the medical staff during interventional radiology and cardiology procedures. Numerical simulations can play an important role in evaluating extremity and eye lens doses in correlation with many different parameters. In the present study, the first results of the ORAMED (Optimisation of Radiation protection of MEDical staff) simulation campaign are presented. The parameters investigated for their influence on eye lens, hand, wrist and leg doses are: tube voltage, filtration, beam projection, field size and irradiated part of the patient's body. The tube voltage ranged from 60 to 110 kV(p), filtration from 3 to 6 mm Al and from 0 to 0.9 mm Cu. For all projections, the results showed that doses received by the operator decreased with increasing tube voltage and filtration. The magnitude of the influence of the tube voltage and the filtration on the doses depends on the beam projection and the irradiated part of the patient's body. Finally, the influence of the field size is significant in decreasing the doses.


Assuntos
Extremidades/efeitos da radiação , Cristalino/efeitos da radiação , Exposição Ocupacional/prevenção & controle , Proteção Radiológica/instrumentação , Radiologia Intervencionista/instrumentação , Radiometria/instrumentação , Alumínio/química , Antropometria , Simulação por Computador , Cobre/química , Humanos , Corpo Clínico , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Proteção Radiológica/métodos , Radiologia Intervencionista/métodos , Radiometria/métodos
11.
Radiat Prot Dosimetry ; 144(1-4): 173-6, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21196464

RESUMO

The use of active personal dosemeters (APDs) not only as a warning device but also, in some cases, as an official and hence stand-alone dosemeter is rapidly increasing. A comparison in terms of dose, energy and angle dependence, among different types of APD and a routinely used whole-body thermoluminescence dosemeter (TLD) has been performed. Significant differences were found between the TLD readings and mainly some not commonly used APDs. The importance of choosing the best adapted APD according to the radiation field characteristics is pointed out.


Assuntos
Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Dosimetria Termoluminescente/instrumentação , Calibragem , Radioisótopos de Césio/farmacologia , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Humanos , Exposição Ocupacional , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Radiometria/instrumentação , Radiometria/métodos , Reprodutibilidade dos Testes , Dosimetria Termoluminescente/métodos , Imagem Corporal Total
12.
Br J Radiol ; 84(997): 70-7, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21172967

RESUMO

OBJECTIVES: The aim of this study was to determine occupational dose levels in interventional radiology and cardiology procedures. METHODS: The study covered a sample of 25 procedures and monitored occupational dose for all laboratory personnel. Each individual wore eight thermoluminescent dosemeters next to the eyes, wrists, fingers and legs during each procedure. Radiation protection shields used in each procedure were recorded. RESULTS: The highest doses per procedure were recorded for interventionists at the left wrist (average 485 µSv, maximum 5239 µSv) and left finger (average 324 µSv, maximum 2877 µSv), whereas lower doses were recorded for the legs (average 124 µSv, maximum 1959 µSv) and the eyes (average 64 µSv, maximum 1129 µSv). Doses to the assisting nurses during the intervention were considerably lower; the highest doses were recorded at the wrists (average 26 µSv, maximum 41 µSv) and legs (average 18 µSv, maximum 22 µSv), whereas doses to the eyes were minimal (average 4 µSv, maximum 16 µSv). Occupational doses normalised to kerma area product (KAP) ranged from 11.9 to 117.3 µSv/1000 cGy cm² and KAP was poorly correlated to the interventionists' extremity doses. CONCLUSION: Calculation of the dose burden for interventionists considering the actual number of procedures performed annually revealed that dose limits for the extremities and the lenses of the eyes were not exceeded. However, there are cases in which high doses have been recorded and this can lead to exceeding the dose limits when bad practices are followed and the radiation protection tools are not properly used.


Assuntos
Extremidades/efeitos da radiação , Exposição Ocupacional/prevenção & controle , Proteção Radiológica/normas , Radiologia Intervencionista , Feminino , Humanos , Masculino , Corpo Clínico Hospitalar , Doses de Radiação , Radiologia Intervencionista/métodos
13.
Radiat Prot Dosimetry ; 144(1-4): 482-6, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21044993

RESUMO

The present study is focused on the personnel doses during several types of interventional radiology procedures. Apart from the use of the official whole body dosemeters (thermoluminescence dosemeter type), measurements were performed to the extremities and the eyes using thermoluminescent loose pellets. The mean doses per kerma area product were calculated for the monitored anatomic regions and for the most frequent types of procedures. Higher dose values were measured during therapeutic procedures, especially embolisations. The maximum recorded doses during a single procedure were 1.8 mSv to the finger (nephrostomy), 2.1 mSv to the wrist (liver chemoembolisation), 0.6 mSv to the leg (brain embolisation) and 2.4 mSv to the eye (brain embolisation). The annual doses estimated for the operator with the highest workload according to the measurements and the system's log book were 90.4 mSv to the finger, 107.9 mSv to the wrist, 21.6 mSv to the leg and 49.3 mSv to the eye. Finally, the effect of the beam angulation (i.e. projection) and shielding equipment on the personnel doses was evaluated. The measurements were performed within the framework of the ORAMED (Optimization of RAdiation Protection for MEDical staff) project.


Assuntos
Extremidades/efeitos da radiação , Cristalino/efeitos da radiação , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Radiologia Intervencionista , Radiometria/instrumentação , Angiografia/métodos , Desenho de Equipamento , Humanos , Chumbo , Exposição Ocupacional/análise , Roupa de Proteção , Equipamentos de Proteção , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Radiometria/métodos , Dosimetria Termoluminescente/instrumentação , Dosimetria Termoluminescente/métodos , Recursos Humanos
14.
Radiat Prot Dosimetry ; 144(1-4): 442-7, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21183540

RESUMO

The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in different hospitals in Europe will help towards this direction. This study aims at analysing the first results of the measurement campaign performed in IR and IC procedures in 34 European hospitals. The highest doses were found for pacemakers, renal angioplasties and embolisations. Left finger and wrist seem to receive the highest extremity doses, while the highest eye lens doses are measured during embolisations. Finally, it was concluded that it is difficult to find a general correlation between kerma area product and extremity or eye lens doses.


Assuntos
Cardiologia/métodos , Extremidades/efeitos da radiação , Cristalino/efeitos da radiação , Exposição Ocupacional/prevenção & controle , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Proteção Radiológica/normas , Radiologia Intervencionista/métodos , Simulação por Computador , Humanos , Cooperação Internacional , Doses de Radiação , Radiometria/métodos , Eficiência Biológica Relativa , Medição de Risco , Inquéritos e Questionários , Dosimetria Termoluminescente/métodos , Recursos Humanos
15.
Radiat Prot Dosimetry ; 144(1-4): 453-8, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21186215

RESUMO

The work package 3 of the ORAMED project, Collaborative Project (2008-11) supported by the European Commission within its seventh Framework Programme, is focused on the optimisation of the use of active personal dosemeters (APDs) in interventional radiology and cardiology (IR/IC). Indeed, a lack of appropriate APD devices is identified for these specific fields. Few devices can detect low-energy X rays (20-100 keV), and none of them are specifically designed for working in pulsed radiation fields. The work presented in this paper consists in studying the behaviour of some selected APDs deemed suitable for application in IR/IC. For this purpose, measurements under laboratory conditions, both with continuous and pulsed X-ray beams, and tests in real conditions on site in different European hospitals were performed. This study highlights the limitations of APDs for this application and the need of improving the APD technology so as to fulfil all needs in the IR/IC field.


Assuntos
Cardiologia , Exposição Ocupacional/prevenção & controle , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Radiologia Intervencionista , Radiometria/instrumentação , Desenho de Equipamento , Europa (Continente) , Hospitais , Humanos , Laboratórios , Método de Monte Carlo , Equipamentos de Proteção , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Radiação Ionizante , Radiometria/métodos , Recursos Humanos , Raios X