Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Paediatr Int Child Health ; 35(3): 213-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26134488

RESUMO

BACKGROUND: At the time of the research, Dr Weiss was a clinical fellow in neonatal-perinatal medicine at Baylor College of Medicine, Texas Children's Hospital. Dr Profit was on faculty at Baylor College of Medicine, Texas Children's Hospital, Department of Pediatrics, Section of Neonatology. He held a secondary appointment in the Department of Medicine, Section of Health Services Research and conducted his research at the VA Health Services Research and Development Center of Excellence where he collaborated with Dr Kowalkowski.: Improving the quality of neonatal intensive care is an important health policy priority in Mexico. A formal assessment of barriers and priorities for quality improvement has not been undertaken. AIM: To provide guidance to providers and policy makers with regard to addressing opportunities for better care delivery in Mexican neonatal intensive care units. OBJECTIVE: To conduct a needs assessment regarding improvement of quality of neonatal intensive care delivery in Mexico. METHODS: Spanish-language survey administered to a volunteer sample of Mexican neonatal care providers attending a large paediatric conference in Mexico in June 2011. Survey domains included institutional context of quality improvement, barriers, priorities, safety culture, and respondents' characteristics. Results were analysed using descriptive analyses of frequencies, proportions and percentage positive response (PPR) rates. RESULTS: Of 91 respondents, the majority identified neonatology as their primary specialty (n = 48, 65%) and were physicians (n = 55, 73%). Generally, providers expressed a desire to improve quality of care (PPR 69%) but reported notable deterrents. Respondents (n, %) identified family inability to pay (38, 48%), overcrowded work areas (38, 44%), insufficient financial reimbursement (25, 36%), lack of availability of nurses (26, 30%), ancillary staff (25, 29%), and subspecialists (22, 25%) as the principal barriers. Respiratory care (27, 39%)--reduction of mechanical ventilation and initiation of nasal continuous positive airway pressure--and reduction in frequency of late-onset infections (19, 28%) were selected as top clinical priorities. There were substantial opportunities for improving safety (PPR 48%) and teamwork climate (PPR 58%). CONCLUSION: These findings may guide efforts to improving quality of care delivery in Mexican neonatal intensive care units.


Assuntos
Terapia Intensiva Neonatal/métodos , Terapia Intensiva Neonatal/organização & administração , Avaliação das Necessidades , Feminino , Humanos , Masculino , México , Qualidade da Assistência à Saúde
2.
Cancer Epidemiol ; 38(4): 386-92, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24947588

RESUMO

BACKGROUND: Hodgkin lymphoma (HL) incidence has increased since combined antiretroviral therapy (cART) introduction. It is unclear how different cART classes (e.g., protease inhibitors (PI), non-nucleoside reverse transcription inhibitors (NNRTI)) influence HL. This study aimed to determine the effects of cART duration on HL incidence among HIV-infected veterans. METHODS: We performed a retrospective cohort study utilizing the Veterans Affairs HIV Clinical Case Registry (1985-2010). HL cases were identified using ICD-9 codes (201.4-9). cART, PI, and NNRTI duration was the aggregate number of treatment days delivered. Incidence rates (IR) and rate ratios (IRR) were calculated from Poisson regression models to examine the effects of cART duration on HL. RESULTS: 31,576 cART users contributed 288,736 person-years (PY) and 211 HL cases (IR=7.3/10,000 person-years). HL incidence decreased from 25.1/10,000 PY (95%CI=18.9-33.4) within the first year of cART to 0.6/10,000 PY (95%CI=0.3-1.6) after ≥ 10 years. In multivariable models, each additional year of cART was associated with decreased HL incidence (IRR=0.80; 95%CI=0.75-0.86); similar effects were observed in models assessing HL incidence by PI and NNRTI. CONCLUSION: Our findings indicate long-term cART of any class is associated with decreased HL risk. High HL incidence directly following cART initiation supports a potential immune reconstitution mechanism in HIV-related HL. Further research is needed to evaluate the interaction between early cART, immune reconstitution, and HL.


Assuntos
Fármacos Anti-HIV/administração & dosagem , Infecções por HIV/complicações , Doença de Hodgkin/epidemiologia , Adulto , Estudos de Coortes , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Veteranos
3.
J Perinatol ; 31(11): 702-10, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21350429

RESUMO

OBJECTIVE: To systematically rate measures of care quality for very low birth weight infants for inclusion into Baby-MONITOR, a composite indicator of quality. STUDY DESIGN: Modified Delphi expert panelist process including electronic surveys and telephone conferences. Panelists considered 28 standard neonatal intensive care unit (NICU) quality measures and rated each on a 9-point scale taking into account pre-defined measure characteristics. In addition, panelists grouped measures into six domains of quality. We selected measures by testing for rater agreement using an accepted method. RESULT: Of 28 measures considered, 13 had median ratings in the high range (7 to 9). Of these, 9 met the criteria for inclusion in the composite: antenatal steroids (median (interquartile range)) 9(0), timely retinopathy of prematurity exam 9(0), late onset sepsis 9(1), hypothermia on admission 8(1), pneumothorax 8(2), growth velocity 8(2), oxygen at 36 weeks postmenstrual age 7(2), any human milk feeding at discharge 7(2) and in-hospital mortality 7(2). Among the measures selected for the composite, the domains of quality most frequently represented included effectiveness (40%) and safety (30%). CONCLUSION: A panel of experts selected 9 of 28 routinely reported quality measures for inclusion in a composite indicator. Panelists also set an agenda for future research to close knowledge gaps for quality measures not selected for the Baby-MONITOR.


Assuntos
Recém-Nascido de muito Baixo Peso , Unidades de Terapia Intensiva Neonatal/normas , Garantia da Qualidade dos Cuidados de Saúde , Coleta de Dados , Técnica Delphi , Humanos , Recém-Nascido , Qualidade da Assistência à Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA