Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 34(7): 4273-4283, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38177617

RESUMO

OBJECTIVES: To determine the diagnostic accuracy of ultra-high-resolution photon-counting detector CT angiography (UHR PCD-CTA) for evaluating coronary stent patency compared to invasive coronary angiography (ICA). METHODS: Consecutive, clinically referred patients with prior coronary stent implantation were prospectively enrolled between August 2022 and March 2023 and underwent UHR PCD-CTA (collimation, 120 × 0.2 mm). Two radiologists independently analyzed image quality of the in-stent lumen using a 5-point Likert scale, ranging from 1 ("excellent") to 5 ("non-diagnostic"), and assessed all coronary stents for the presence of in-stent stenosis (≥ 50% lumen narrowing). The diagnostic accuracy of UHR PCD-CTA was determined, with ICA serving as the standard of reference. RESULTS: A total of 44 coronary stents in 18 participants (mean age, 83 years ± 6 [standard deviation]; 12 women) were included in the analysis. In 3/44 stents, both readers described image quality as non-diagnostic, whereas reader 2 noted a fourth stent to have non-diagnostic image quality. In comparison to ICA, UHR PCD-CTA demonstrated a sensitivity, specificity, and accuracy of 100% (95% CI [confidence interval] 47.8, 100), 92.3% (95% CI 79.1, 98.4), and 93.2% (95% CI 81.3, 98.6) for reader 1 and 100% (95% CI 47.8, 100), 87.2% (95% CI 72.6, 95.7), and 88.6% (95% CI 75.4, 96.2) for reader 2, respectively. Both readers observed a 100% negative predictive value (36/36 stents and 34/34 stents). Stent patency inter-reader agreement was 90.1%, corresponding to a substantial Cohen's kappa value of 0.72. CONCLUSIONS: UHR PCD-CTA enables non-invasive assessment of coronary stent patency with high image quality and diagnostic accuracy. CLINICAL RELEVANCE STATEMENT: Ultra-high-resolution photon-counting detector CT angiography represents a reliable and non-invasive method for assessing coronary stent patency. Its high negative predictive value makes it a promising alternative over invasive coronary angiography for the rule-out of in-stent stenosis. KEY POINTS: • CT-based evaluation of coronary stent patency is limited by stent-induced artifacts and spatial resolution. • Ultra-high-resolution photon-counting detector CT accurately evaluates coronary stent patency compared to invasive coronary angiography. • Photon-counting detector CT represents a promising method for the non-invasive rule-out of in-stent stenosis.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Sensibilidade e Especificidade , Stents , Humanos , Feminino , Masculino , Angiografia Coronária/métodos , Idoso de 80 Anos ou mais , Estudos Prospectivos , Angiografia por Tomografia Computadorizada/métodos , Idoso , Fótons
2.
Radiology ; 307(5): e223305, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37338354

RESUMO

Background Recently introduced photon-counting CT may improve noninvasive assessment of patients with high risk for coronary artery disease (CAD). Purpose To determine the diagnostic accuracy of ultrahigh-resolution (UHR) coronary CT angiography (CCTA) in the detection of CAD compared with the reference standard of invasive coronary angiography (ICA). Materials and Methods In this prospective study, participants with severe aortic valve stenosis and clinically indicated CT for transcatheter aortic valve replacement planning were consecutively enrolled from August 2022 to February 2023. All participants were examined with a dual-source photon-counting CT scanner using a retrospective electrocardiography-gated contrast-enhanced UHR scanning protocol (tube voltage, 120 or 140 kV; collimation, 120 × 0.2 mm; 100 mL of iopromid; no spectral information). Subjects underwent ICA as part of their clinical routine. A consensus assessment of image quality (five-point Likert scale: 1 = excellent [absence of artifacts], 5 = nondiagnostic [severe artifacts]) and a blinded independent reading for the presence of CAD (stenosis ≥50%) were performed. UHR CCTA was compared with ICA using area under the receiver operating characteristic curve (AUC). Results Among 68 participants (mean age, 81 years ± 7 [SD]; 32 male, 36 female), the prevalence of CAD and prior stent placement was 35% and 22%, respectively. The overall image quality was excellent (median score, 1.5 [IQR, 1.3-2.0]). The AUC of UHR CCTA in the detection of CAD was 0.93 per participant (95% CI: 0.86, 0.99), 0.94 per vessel (95% CI: 0.91, 0.98), and 0.92 per segment (95% CI: 0.87, 0.97). Sensitivity, specificity, and accuracy, respectively, were 96%, 84%, and 88% per participant (n = 68); 89%, 91%, and 91% per vessel (n = 204); and 77%, 95%, and 95% per segment (n = 965). Conclusion UHR photon-counting CCTA provided high diagnostic accuracy in the detection of CAD in a high-risk population, including subjects with severe coronary calcification or prior stent placement. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Williams and Newby in this issue.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos Prospectivos , Estudos Retrospectivos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos
3.
Cardiology ; 146(2): 228-237, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32966978

RESUMO

AIM: The present study analyzes in depth the impact of different calcification patterns on disturbances of the conduction system in transcatheter aortic valve replacement (TAVR) patients. METHODS AND RESULTS: A total of 169 preprocedural TAVR multislice computed tomography scans from consecutive transfemoral (TF) TAVRs performed between 2014 and 2017 using either Edwards SAPIEN or Medtronic Evolut R valves were retrospectively evaluated. The volume, distribution, and orientation of annular and valvular aortic valve calcification were measured and their impact on postoperative conduction disturbances was determined using linear and logistic regression analyses. The total volume of calcification and distribution at the aortic annulus or valve did not influence the conduction system. Oval calcification of the left aortic cusp was independently associated with an elevated risk for an increase in atrioventricular block degree (+0.6, p = 0.03). Moreover, orthogonal calcifications at the level of the aortic annulus were associated with an increased risk for QRS prolongation (+26 ms, p = 0.004) and an increased risk for permanent pacemaker implantation (OR 4.3, p = 0.03) after TF TAVR. This was more pronounced in patients undergoing TF TAVR using a balloon-expandable Edwards SAPIEN 3 valve (QRS +38.195 ms, p < 0.001; OR permanent pacemaker 15.48, p = 0.013). CONCLUSION: Orthogonal annular calcification confers an increased risk for conduction disturbances after TAVR. This is even more pronounced after implantation of balloon-expandable valves.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Childs Nerv Syst ; 36(10): 2537-2552, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32507909

RESUMO

INTRODUCTION: Hemangioblastomas are rare, histologically benign, highly vascularized tumors of the brain, the spinal cord, and the retina, occurring sporadically or associated with the autosomal dominant inherited von Hippel-Lindau (VHL) disease. Children or adults with VHL disease have one of > 300 known germline mutations of the VHL gene located on chromosome 3. They are prone to develop hemangioblastomas, extremely rarely starting at age 6, rarely at age 12-18, and, typically and almost all, as adults. There is a plethora of VHL-associated tumors and cysts, mainly in the kidney, pancreas, adrenals, reproductive organs, and central nervous system. Due to a lack of causal treatment, alleviation of symptoms and prevention of permanent neurological deficits as well as malignant transformation are the main task. Paucity of data and the nonlinear course of tumor progression make management of pediatric VHL patients with hemangioblastomas challenging. METHODS: The Freiburg surveillance protocol was developed by combining data from the literature and our experience of examinations of > 300 VHL patients per year at our university VHL center. RESULTS: Key recommendations are to start screening of patients at risk by funduscopy with dilated pupils for retinal tumors with admission to school and with MRI of the brain and spinal cord at age 14, then continue biannually until age 18, with emergency MRI in case of neurological symptoms. Indication for surgery remains personalized and should be approved by an experienced VHL board, but we regard neurological symptoms, rapid tumor growth, or critically large tumor/cyst sizes as the key indications to remove hemangioblastomas. Since repeated surgery on hemangioblastomas in VHL patients is not rare, modern neurosurgical techniques should encompass microsurgery, neuronavigation, intraoperative neuromonitoring, fluorescein dye-based intraoperative angiography, intraoperative ultrasound, and minimally invasive approaches, preceded in selected cases by endovascular embolization. Highly specialized neurosurgeons are able to achieve a very low risk of permanent morbidity for the removal of hemangioblastomas from the cerebellum and spinal cord. Small retinal tumors of the peripheral retina can be treated by laser coagulation, larger tumors by cryocoagulation or brachytherapy. CONCLUSION: We consider management at experienced VHL centers mandatory and careful surveillance and monitoring of asymptomatic lesions are required to prevent unnecessary operations and minimize morbidity.


Assuntos
Hemangioblastoma , Neoplasias da Medula Espinal , Doença de von Hippel-Lindau , Adolescente , Adulto , Criança , Patrimônio Genético , Hemangioblastoma/diagnóstico por imagem , Hemangioblastoma/genética , Hemangioblastoma/cirurgia , Humanos , Procedimentos Neurocirúrgicos , Neoplasias da Medula Espinal/diagnóstico por imagem , Neoplasias da Medula Espinal/genética , Neoplasias da Medula Espinal/cirurgia , Doença de von Hippel-Lindau/genética , Doença de von Hippel-Lindau/cirurgia
5.
Radiologe ; 60(12): 1131-1141, 2020 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-33185699

RESUMO

BACKGROUND: Coronary CT angiography (cCTA) has a high negative predictive value for ruling out significant coronary stenoses. However, it is limited in determining hemodynamic significance of a stenosis and hence to prove the indication for therapy. OBJECTIVES: When and how is cCTA used according to current guidelines? Which functional CT techniques are available to test for hemodynamic significance of coronary stenoses? MATERIALS AND METHODS: The value of cCTA is explained on the basis of current guidelines by the European Society of Cardiology (ESC) for the diagnosis of chronic coronary syndromes. Functional CT techniques which test for hemodynamic significance of coronary stenoses are myocardial CT-perfusion (CT­P) and CT-based fractional flow reserve (CT-FFR). RESULTS: The new ESC guidelines classify cCTA as a class 1 recommendation for diagnosing coronary artery disease in symptomatic patients with low clinical likelihood. If clinical likelihood is high or an at least moderate stenosis is detected with cCTA, noninvasive functional (stress) imaging is preferred. There is a large body of evidence for CT­P and CT-FFR as functional tests. CONCLUSION: In the current guidelines, cCTA is highly recommended for the diagnosis of coronary artery disease. The functional CT techniques CT­P and CT-FFR have shown high diagnostic accuracy for myocardial ischemia of coronary stenoses in many clinical studies. However, these methods are not part of current guidelines yet and clinical adoption is still low.


Assuntos
Angiografia Coronária , Reserva Fracionada de Fluxo Miocárdico , Constrição Patológica , Humanos , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X
6.
Langenbecks Arch Surg ; 401(4): 449-56, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27048403

RESUMO

PURPOSE: The purpose of this study was to retrospectively evaluate diagnostic accuracy of cystic lesions of the pancreas in order to determine if less aggressive surgical treatment might be safe and therefore warranted. METHODS: A retrospective cohort study was conducted in 232 patients with either observed or resected cystic lesions of the pancreas referred for evaluation and treatment to the University Medical Center Freiburg, Germany, between 2001 and 2011. RESULTS: Most patients had MRI or CT for preoperative imaging (90.6 %). Preoperatively, benign pseudocysts (BPC) were diagnosed in 84 (36.2 %) patients and intraductal papillary mucinous neoplasm (IPMN) in 59 (25.2 %) patients, whereas serous cyst adenoma, mucinous cystic neoplasm (MCN), solid pseudopapillary tumors (SPPTs), and neuroendocrine tumors (NETs) were less common. In 43 % of patients, the preoperative diagnosis concurred with the postoperative diagnosis. The preoperative diagnosis was accurate in BPC, less so in IPMN, and inaccurate in MCN, NET, and SPPT. However, prediction of tumor biology was accurate; only 11 % of the lesions regarded as benign turned out to be malignant after resection, and no patient without resection developed malignancy at a median follow-up of 8 months. Subsequently, 89 % of diagnosed benign tumors had indeed benign pathology. CONCLUSIONS: The prediction of biology is often correct, whereas specific diagnosis is often wrong. A considerable amount of benign lesions are treated more aggressively than warranted if malignancy is suspected prior to surgery. Parenchyma-sparing techniques might be an option, but prospective multicenter studies need to follow. Experienced pancreatic radiologists can improve accuracy of preoperative biology.


Assuntos
Cisto Pancreático/diagnóstico por imagem , Cisto Pancreático/cirurgia , Idoso , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Pancreatectomia , Cisto Pancreático/patologia , Pancreaticoduodenectomia , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
7.
BMC Musculoskelet Disord ; 17: 147, 2016 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-27044378

RESUMO

BACKGROUND: The aim of this study was to assess and present the radiological morphology of the non-ossifying fibroma (NOF), to describe the life span according to the Ritschl-stages in an effort to determine critical stages with regard to pathological fractures and discuss the need for a follow-up. METHODS: Reports of a consecutive series of 87 patients with 103 NOFs and a mean follow-up of 27 months were analysed according to the Ritschl-stages with regard to age at time of diagnosis, localisation, duration of stage and symptoms. RESULTS: Mean patient age in our series was 20 years and lesions most frequently affected the long bones of the lower extremity. Nineteen lesions were categorized in stage A, 53 in stage B, 17 in stage C and 14 in stage D. Most lesions were detected incidentally. In six of ten clinically symptomatic patients with an average age of ten years a pathological fracture occurred, and four of them were located in the tibia. All of these were in stage B with a mean length of 44 mm, an average expansion in relation to the bone-diameter of 75 % in transversal and 87 % in sagittal plane. Duration of the stages was variable. In the critical stage B the mean was 21 months. CONCLUSION: The non-ossifying fibroma follows a characteristic radiomorphological course with variable duration of each stage. Stage B lesions were found to be at an increased risk of fracture, and the age range over which fractures occur was wide. No fractures were detected in the other three stages. Follow-up, including clinical survey and imaging, at six to twelve month intervals may therefore be considered in the case of larger stage B lesions until stage C is reached.


Assuntos
Neoplasias Ósseas/complicações , Fibroma/complicações , Fraturas Ósseas/etiologia , Fraturas Espontâneas/etiologia , Adolescente , Adulto , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/patologia , Criança , Progressão da Doença , Feminino , Fibroma/diagnóstico por imagem , Fibroma/patologia , Fraturas Ósseas/diagnóstico por imagem , Fraturas Espontâneas/diagnóstico por imagem , Humanos , Achados Incidentais , Masculino , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Adulto Jovem
8.
Strahlenther Onkol ; 191(4): 310-20, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25326142

RESUMO

BACKGROUND: Nodal pelvic/retroperitoneal recurrent prostate cancer (PCa) after primary therapy can be treated with salvage lymph node dissection (salvage-LND) in order to delay disease progression and offer cure for a subset of patients. Whether adjuvant radiotherapy (ART) in affected regions improves the outcome by elimination of residual tumour burden remains unclear. METHODS: A total of 93 patients with exclusively nodal PCa relapse underwent choline-positron-emission tomography-computed-tomography-directed pelvic/retroperitoneal salvage-LND; 46 patients had surgery only and 47 patients received ART in regions with proven lymph node metastases. In case of subsequent prostate specific antigen (PSA) progression, different imaging modalities were performed to confirm next relapse within or outside the treated region (TR). Mean follow-up was 3.2 years. RESULTS: Lymphatic tumour burden was balanced between the two groups. Additional ART resulted in delayed relapse within TR (5-year relapse-free rate 70.7 %) versus surgery only (5-year relapse-free rate 26.3 %, p < 0.0001). In both treatment arms, time to next relapse outside the TR was almost equal (median 27 months versus 29.6 months, p = 0.359). With respect to the detection of the first new lesion, regardless if present within or outside the TR, 5 years after the treatment 34.3 % of patients in the group with additional ART were free of relapse, versus 15.4 % in the surgery only group (p = 0.0122). ART had no influence on the extent of PSA reduction at latest follow-up compared to treatment with surgery only. CONCLUSION: ART after salvage-LND provides stable local control in TR and results in overall significant improved next-relapse-free survival, compared to patients who received surgery only in case of nodal PCa-relapse.


Assuntos
Excisão de Linfonodo/métodos , Recidiva Local de Neoplasia/prevenção & controle , Recidiva Local de Neoplasia/radioterapia , Neoplasias da Próstata/terapia , Terapia de Salvação/métodos , Idoso , Terapia Combinada/métodos , Humanos , Metástase Linfática , Masculino , Recidiva Local de Neoplasia/diagnóstico , Neoplasia Residual , Neoplasias da Próstata/diagnóstico , Radioterapia Adjuvante/métodos , Estudos Retrospectivos , Resultado do Tratamento
9.
Europace ; 17(10): 1526-32, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25745072

RESUMO

AIMS: Lesion formation during catheter ablation crucially depends on catheter-tissue contact. We sought to evaluate the impact of anatomical characteristics of the left atrium (LA) and the pulmonary veins (PVs) on contact force (CF) measurements. METHODS AND RESULTS: An anatomical map of the LA was obtained in 25 patients prior to catheter ablation of atrial fibrillation. Contact force (operator blinded) and local bipolar electrogram amplitudes (EGM) were measured in eight pre-defined segments around the PVs. After unblinding, points with low CF (≤5 g) were corrected to CF >5 g, and the distance between points was measured. In a pre-procedural computed tomography of the heart, LA volume as well as sizes and circumferences of the PV ostia were measured and correlated to CF measurements. Four hundred and twenty-six points in eight pre-defined LA locations were assessed. Low CF (<5 g) was found in 25.0% (43.5%) of points superior, 33.3% (66.7%) anterior, 32.1% (44.4%) inferior, and 15.5% (15.9%) posterior to the right (left) PVs. The mean distance after correction was 5.8 ± 3.4 mm. Local bipolar electrogram amplitudes between low- and high-CF points did not differ (1.21 ± 1.54 vs. 1.13 ± 1.3 mV, P = ns). The mean CF at the left PVs was significantly lower than at the right PVs (7.91 ± 3.74 vs. 13.95 ± 6.34 g, P < 0.001), with the lowest CF anterior to the left PVs (5.2 ± 3.6 g). Contact force measurements did not correlate to LA volume, size, and circumference of the PVs. CONCLUSION: Contact force during LA mapping significantly differs according to the location within the LA. These differences are independent of LA volume and anatomy of the PV ostia.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/anatomia & histologia , Veias Pulmonares/cirurgia , Idoso , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Resultado do Tratamento
10.
J Urol ; 192(1): 103-10, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24518792

RESUMO

PURPOSE: We evaluated the diagnostic accuracy of choline positron emission tomography/computerized tomography for nodal relapse of prostate cancer according to topographical site and tumor infiltration size in lymph nodes. MATERIALS AND METHODS: A total of 72 patients with nodal prostate cancer relapse after primary therapy underwent pelvic and/or retroperitoneal salvage lymph node dissection. Salvage was done after whole body positron emission tomography/computerized tomography with (11)C-choline or (18)F-fluoroethylcholine showed positron emission tomography positive lymph nodes but no other detectable metastasis. Diagnostic accuracy was evaluated in 160 dissected lymph node regions (pelvic left/right and retroperitoneal), 498 subregions (common, external and internal iliac, obturator, presacral, aortic bifurcation, aortal, vena caval and interaortocaval) and 2,122 lymph nodes. RESULTS: Lymph node metastasis was present in 32% of resected lymph nodes (681 of 2,122), resulting in 238 positive subregions and 111 positive regions. Positron emission tomography/computerized tomography was positive for 110 regions and 209 subregions. Sensitivity, specificity, positive and negative predictive values, and accuracy were 91.9%, 83.7%, 92.7%, 82.0% and 89.4% (region based), 80.7%, 93.5%, 91.9%, 84.1% and 87.3% (subregion based), and 57.0%, 98.4%, 94.5%, 82.6% and 84.9% (lesion based), respectively. Of 393 positive lymph node metastases detected by this method 278 (70.7%) were in lymph nodes with a less than 10 mm short axis diameter. Imaging sensitivity was 13.3%, 57.4% and 82.8% for a tumor infiltration depth of 2 or greater to less than 3 mm, 5 or greater to less than 6 mm and 10 or greater to less than 11 mm, respectively. Lymph node metastasis site and the radiotracer ((11)C-choline/(18)F-fluoroethylcholine) had no substantial impact on diagnostic accuracy. CONCLUSIONS: Choline positron emission tomography/computerized tomography detects affected lymph node regions (pelvic left/right and retroperitoneal) in patients with prostate cancer relapse with high accuracy and it seems helpful for guiding salvage lymph node dissection. Sensitivity decreases with the size of metastatic infiltration in lymph nodes. This technique detects metastasis in a significant fraction of lymph nodes that are not pathologically enlarged on computerized tomography.


Assuntos
Radioisótopos de Carbono , Colina/análogos & derivados , Recidiva Local de Neoplasia/diagnóstico , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico , Tomografia Computadorizada por Raios X , Idoso , Humanos , Metástase Linfática/diagnóstico , Masculino , Imagem Multimodal , Estudos Retrospectivos
11.
Eur J Radiol ; 173: 111360, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38342061

RESUMO

PURPOSE: To determine the diagnostic accuracy of volumetric interpolated breath-hold examination sequences with fat suppression in Dixon technique (VIBE-Dixon) for cardiac thrombus detection. METHOD: From our clinical database, we retrospectively identified consecutive patients between 2014 and 2022 who had definite diagnosis or exclusion of cardiac thrombus confirmed by an independent adjudication committee, serving as the reference standard. All patients received 2D-Cine plus 2D-Late-Gadolinium-Enhancement (Cine + LGE) and VIBE-Dixon sequences. Two blinded readers assessed all images for the presence of cardiac thrombus. The diagnostic accuracy of Cine + LGE and VIBE-Dixon was determined and compared. RESULTS: Among 141 MRI studies (116 male, mean age: 61 years) mean image examination time was 28.8 ± 3.1 s for VIBE-Dixon and 23.3 ± 2.5 min for Cine + LGE. Cardiac thrombus was present in 49 patients (prevalence: 35 %). For both readers sensitivity for thrombus detection was significantly higher in VIBE-Dixon compared with Cine + LGE (Reader 1: 96 % vs.73 %, Reader 2: 96 % vs. 78 %, p < 0.01 for both readers), whereas specificity did not differ significantly (Reader 1: 96 % vs. 98 %, Reader 2: 92 % vs. 93 %, p > 0.1). Overall diagnostic accuracy of VIBE-Dixon was higher than for Cine + LGE (95 % vs. 89 %, p = 0.02) and was non-inferior to the reference standard (Delta ≤ 5 % with probability > 95 %). CONCLUSIONS: Biplanar VIBE-Dixon sequences, acquired within a few seconds, provided a very high diagnostic accuracy for cardiac thrombus detection. They could be used as stand-alone sequences to rapidly screen for cardiac thrombus in patients not amenable to lengthy acquisition times.


Assuntos
Meios de Contraste , Trombose , Humanos , Masculino , Pessoa de Meia-Idade , Gadolínio , Estudos Retrospectivos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Trombose/diagnóstico por imagem , Aumento da Imagem/métodos
12.
Diagn Interv Radiol ; 2024 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-39463047

RESUMO

PURPOSE: The study aimed to assess the feasibility and image quality of dual-source photon-counting detector computed tomography (PCD-CT) in evaluating small-sized coronary artery stents with respect to different acquisition modes in a phantom model. METHODS: Utilizing a phantom setup mimicking the average patient's water-equivalent diameter, we examined six distinct coronary stents inflated in a silicon tube, with stent sizes ranging from 2.0 to 3.5 mm, applying four different CT acquisition modes of a dual-source PCD-CT scanner: "high-pitch," "sequential," "spiral" (each with collimation of 144 × 0.4 mm and full spectral information), and "ultra-high-resolution (UHR)" (collimation of 120 × 0.2 mm and no spectral information). Image quality and diagnostic confidence were assessed using subjective measures, including a 4-point visual grading scale (4 = excellent; 1 = non-diagnostic) utilized by two independent radiologists, and objective measures, including the full width at half maximum (FWHM). RESULTS: A total of 24 scans were acquired, and all were included in the analysis. Among all CT acquisition modes, the highest image quality was obtained for the UHR mode [median score: 4 (interquartile range (IQR): 3.67-4.00)] (P = 0.0015, with 37.5% rated as "excellent"), followed by the sequential mode [median score: 3.5 (IQR: 2.84-4.00)], P = 0.0326 and the spiral mode [median score: 3.0 (IQR: 2.53-3.47), P > 0.05]. The lowest image quality was observed for the high-pitch mode [median score: 2 (IQR: 1- 3), P = 0.028]. Similarly, diagnostic confidence for evaluating stent patency was highest for UHR and lowest for high-pitch (P < 0.001, respectively). Measurement of stent dimensions was accurate for all acquisition modes, with the UHR mode showing highest robustness (FWHM for sequential: 0.926 ± 0.061 vs. high-pitch: 0.990 ± 0.083 vs. spiral: 0.962 ± 0.085 vs. UHR: 0.941 ± 0.036, P = non-significant, respectively). CONCLUSION: Assessing small-sized coronary stents using PCD-CT technology is feasible. The UHR mode offers superior image quality and diagnostic confidence, while all modes show consistent and accurate measurements. CLINICAL SIGNIFICANCE: These findings highlight the potential of PCD-CT technology, particularly the UHR mode, to enhance non-invasive coronary stent evaluation. Confirmatory research is necessary to influence the guidelines, which recommend cardiac CT only for stents of 3 mm or larger.

13.
Clin Res Cardiol ; 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39230714

RESUMO

AIMS: To quantify greyzone fibrosis (GZF) in patients after acute myocardial infarction (MI) and to evaluate its correlation with MI-free survival and improvements in left ventricular ejection fraction (LVEF) compared with the established risk factors high-sensitivity cardiac troponin T (hs-cTnT) and Late Gadolinium Enhancement (LGE). METHODS AND RESULTS: The study involved 176 patients who experienced acute MI and underwent cardiac magnetic resonance (CMR) prior to hospital discharge, followed by a second CMR on average six months later. LGE was quantified in both examinations, a separate analysis of the GZF was conducted only in the follow-up CMR after resolution of the initial infarct edema. LVEF was measured in both CMR. hs-cTnT levels were assessed at hospital admission, as well as 8, 16, 24, 48 and 72 h after coronary intervention. Telephone follow-ups were conducted annually for up to 8 years. LGE measurements showed better correlation with MI-free survival (Harrell's C of 0.711 of LGE mass) compared to GZF (0.579 of GZF mass). Additionally, hs-cTnT outperformed GZF (Harrell's C of 0.645). As an univariable predictor for MI-free survival, only hs-cTnT reached significance (p < 0.05). With regard to improvements in ejection fraction, both hs-cTnT and LGE measurements showed acceptable correlation with improvement in ejection fraction (p < 0.05), while GZF measurements showed no correlation (p > 0.5). CONCLUSIONS: In CMR, the assessment of GZF demonstrated inferior p correlation compared to hs-cTnT and LGE in patients after acute MI with respect to the endpoint of MI-free survival. Furthermore, GZF showed no correlation with the improvement of LVEF.

14.
Int J Cardiovasc Imaging ; 40(4): 811-820, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38360986

RESUMO

To compare the diagnostic value of ultrahigh-resolution CT-angiography (UHR-CTA) compared with high-pitch spiral CTA (HPS-CTA) using a first-generation, dual-source photon-counting CT (PCD-CT) scanner for preprocedural planning of transcatheter aortic valve replacement (TAVR). Clinically referred patients with severe aortic valve stenosis underwent both, retrospective ECG-gated cardiac UHR-CTA (collimation: 120 × 0.2 mm) and prospective ECG-triggered aortoiliac HPS-CTA (collimation: 144 × 0.4 mm, full spectral capabilities) for TAVR planning from August 2022 to March 2023. Radiation dose was extracted from the CT reports, and the effective dose was calculated. Two radiologists analyzed UHR-CTA and HPS-CTA datasets, assessing the image quality of the aortic annulus, with regard to the lumen visibility and margin delineation using a 4-point visual-grading scale (ranges: 4 = "excellent" to 1 = "poor"). Aortic annulus area (AAA) measurements were taken for valve prosthesis sizing, with retrospective UHR-CTA serving as reference standard. A total of 64 patients were included (mean age, 81 years ± 7 SD; 28 women) in this retrospective study. HPS-CTA showed a lower radiation dose, 4.1 mSv vs. 12.6 mSv (p < 0.001). UHR-CTA demonstrated higher image quality to HPS-CTA (median score, 4 [IQR, 3-4] vs. 3 [IQR, 2-3]; p < 0.001). Quantitative assessments of AAA from both CTA datasets were strongly positively correlated (mean 477.4 ± 91.1 mm2 on UHR-CTA and mean 476.5 ± 90.4 mm2 on HPS-CTA, Pearson r2 = 0.857, p < 0.001) with a mean error of 22.3 ± 24.6 mm2 and resulted in identical valve prosthesis sizing in the majority of patients (91%). Patients with lower image quality on HPS-CTA (score value 1 or 2, n = 28) were more likely to receive different sizing recommendations (82%). Both UHR-CTA and HPS-CTA acquisitions using photon-counting CT technology provided reliable aortic annular assessments for TAVR planning. While UHR-CTA offers superior image quality, HPS-CTA is associated with lower radiation exposure. However, severely impaired image quality on HPS-CTA may impact on prosthesis sizing, suggesting that immediate post-scan image evaluations may require complementary UHR-CTA scanning.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Técnicas de Imagem de Sincronização Cardíaca , Angiografia por Tomografia Computadorizada , Eletrocardiografia , Próteses Valvulares Cardíacas , Valor Preditivo dos Testes , Desenho de Prótese , Doses de Radiação , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Feminino , Masculino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Idoso , Substituição da Valva Aórtica Transcateter/instrumentação , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Exposição à Radiação , Tomada de Decisão Clínica , Fótons , Tomografia Computadorizada Multidetectores
15.
Rofo ; 196(1): 25-35, 2024 Jan.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37793417

RESUMO

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD: The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms "photon-counting CT", "photon-counting detector", "spectral CT", "computed tomography" as well as on the authors' own experience. RESULTS: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level. Based on the identified literature, PCD-CT phantom measurements and initial clinical studies have demonstrated that the new technology allows for improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION: For clinical practice, the potential benefits include fewer beam hardening artifacts, a radiation dose reduction, and the use of new or combinations of contrast agents. In particular, critical patient groups such as oncological, cardiovascular, lung, and head & neck as well as pediatric patient collectives benefit from the clinical advantages. KEY POINTS: · Photon-counting computed tomography (PCD-CT) is being used for the first time in routine clinical practice, enabling a significant dose reduction in critical patient populations such as oncology, cardiology, and pediatrics.. · Compared to conventional CT, PCD-CT enables a reduction in electronic image noise.. · Due to the spectral data sets, PCD-CT enables fully comprehensive post-processing applications.. CITATION FORMAT: · Hagen F, Soschynski M, Weis M et al. Photon-counting computed tomography - clinical application in oncological, cardiovascular, and pediatric radiology. Fortschr Röntgenstr 2024; 196: 25 - 34.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Humanos , Criança , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Tórax , Imagens de Fantasmas , Pulmão
16.
Diagnostics (Basel) ; 13(12)2023 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-37370957

RESUMO

BACKGROUND: This study investigates whether the scan length adjustment of prospectively ECG-triggered coronary CT angiography (CCTA) using calcium-scoring CT (CAS-CT) images can reduce overall radiation doses. METHODS: A retrospective analysis was conducted on 182 patients who underwent CAS-CT and prospectively ECG-triggered CCTA using a second-generation Dual-Source CT scanner. CCTA planning was based on CAS-CT images, for which simulated scout view planning was performed for comparison. Effective doses were compared between two scenarios: Scenario 1-CAS-CT-derived CCTA + CAS-CT and Scenario 2-scout-view-derived CCTA without CAS-CT. Dose differences were further analyzed with respect to scan mode and body mass index. RESULTS: Planning CCTA using CAS-CT led to a shorter scan length than planning via scout view (114.3 ± 9.7 mm vs. 133.7 ± 13.2 mm, p < 0.001). The whole-examination effective dose was slightly lower for Scenario 1 (3.2 [1.8-5.3] mSv vs. 3.4 [1.5-5.9] mSv; p < 0.001, n = 182). Notably, Scenario 1 resulted in a significantly lower radiation dose for sequential scans and obese patients. Only high-pitch spiral CCTA showed dose reduction in Scenario 2. CONCLUSIONS: Using CAS-CT for planning prospectively ECG-triggered CCTA reduced the overall radiation dose administered compared to scout view planning without CAS-CT, except for high-pitch spiral CCTA, where a slightly opposite effect was observed.

17.
Eur Heart J Cardiovasc Imaging ; 24(12): 1672-1681, 2023 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-37409579

RESUMO

AIMS: To determine the conditions under which early hypoattenuated leaflet thickening (HALT) after transcatheter aortic valve implantation (TAVI) becomes haemodynamically relevant. METHODS AND RESULTS: The study included 100 patients (age: 81.5 ± 5.5 years; female 63%), thereof 50 patients with HALT. After anonymization and randomization, blinded readers measured maximum thrombus thickness per prosthesis (MT_pr) and movement restriction (MR_pr) on electrocardiogram (ECG)-gated whole heart cycle computed tomography angiography. These measurements were compared with echocardiographic mean pressure gradient (mPG), its increase from baseline (ΔmPG), and Doppler velocity index (DVI). Haemodynamic valve deterioration (HVD) was defined as mPG > 20 mmHg. Age, body mass index, valve type, valve size, left ventricular ejection fraction, and atrial fibrillation were considered as influencing factors. Multiple regression analysis revealed that only valve size (P = 0.001) and MT_pr (P = 0.02) had a significant influence on mPG. In an interaction model, valve size moderated the effect of MT_pr on mPG significantly (P = 0.004). Sub-group analysis stratified by valve sizes showed a strong correlation between MT_pr and echocardiographic parameters for 23 mm valves (mPG: r = 0.57, ΔmPG: r = 0.68, DVI: r = 0.55, each with P < 0.001), but neither for 26 nor 29 mm valves (r < 0.2, P > 0.2 for all correlations). Six of seven prostheses with HVD had a 23 mm valve diameter, while one had 29 mm (P = 0.02). CONCLUSION: Early HALT rarely causes significant mPG increase. Our study shows that valve size is a key factor influencing the haemodynamic impact of HALT. In small valve sizes, mPG is more likely to increase. Our study is the first to offer in vivo evidence supporting previous in vitro findings on this topic.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Volume Sistólico , Trombose/diagnóstico por imagem , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Masculino
18.
J Clin Med ; 12(21)2023 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-37959289

RESUMO

Background: We aimed to evaluate the feasibility of a non-contrast time-of-flight magnetic resonance angiography (TOF-MRA) protocol for the pre-procedural access route assessment of transcatheter aortic valve implantation (TAVI) in comparison with contrast-enhanced cardiac dual-source computed tomography angiography (CTA). Methods and Results: In total, 51 consecutive patients (mean age: 82.69 ± 5.69 years) who had undergone a pre-TAVI cardiac CTA received TOF-MRA for a pre-procedural access route assessment. The MRA image quality was rated as very good (median of 5 [IQR 4-5] on a five-point Likert scale), with only four examinations rated as non-diagnostic. The TOF-MRA systematically underestimated the minimal effective vessel diameter in comparison with CTA (for the effective vessel diameter in mm, the right common iliac artery (CIA)/external iliac artery (EIA)/common femoral artery (CFA) MRA vs. CTA was 8.04 ± 1.46 vs. 8.37 ± 1.54 (p < 0.0001) and the left CIA/EIA/CFA MRA vs. CTA was 8.07 ± 1.32 vs. 8.28 ± 1.34 (p < 0.0001)). The absolute difference between the MRA and CTA was small (for the Bland-Altman analyses in mm, the right CIA/EIA/CFA was -0.36 ± 0.77 and the left CIA/EIA/CFA was -0.25 ± 0.61). The overall correlation between the MRA and CTA measurements was very good (with a Pearson correlation coefficient of 0.87 (p < 0.0001) for the right CIA/EIA/CFA and a Pearson correlation coefficient of 0.9 (p < 0.0001) for the left CIA/EIA/CFA). The feasibility agreement between the MRA and CTA for transfemoral access was good (the right CIA/EIA/CFA agreement was 97.9% and the left CIA/EIA/CFA agreement was 95.7%, Kohen's kappa: 0.477 (p = 0.001)). Conclusions: The TOF-MRA protocol was feasible for the assessment of the access route in an all-comer pre-TAVI population. This protocol might be a reliable technique for patients at an increased risk of contrast-induced nephropathy.

19.
Radiologie (Heidelb) ; 62(11): 947-953, 2022 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-36006439

RESUMO

CLINICAL/METHODICAL ISSUE: Cardiac diseases are the leading cause of death. Many diseases can be specifically treated once a valid diagnosis is established. Cardiac magnetic resonance imaging (MRI) plays a central role in the workup of many cardiac pathologies. However, image acquisition as well as interpretation and related secondary image evaluation are time-consuming and complex. STANDARD RADIOLOGICAL METHODS: Cardiac MRI is becoming increasingly established in international guidelines for the evaluation of cardiac function and differential diagnosis of a wide variety of cardiac diseases. METHODOLOGICAL INNOVATIONS: Cardiac MRI has limited reproducibility due to the acquisition technique and interpretation of findings with complex secondary measurements. Artificial intelligence techniques and radiomics offer the potential to improve the acquisition, interpretation, and reproducibility of cardiac MRI. PERFORMANCE: Research suggests that artificial intelligence and radiomic analysis can improve cardiac MRI in terms of image acquisition and also diagnostic and prognostic value. Furthermore, the implementation of artificial intelligence and radiomics may result in the identification of new biomarkers. ACHIEVEMENTS AND PRACTICAL RECOMMENDATIONS: The implementation of artificial intelligence in cardiac MRI has great potential. However, the current level of evidence is still limited in some aspects; in particular there are too few prospective and large multicenter studies available. As a result, the algorithms developed are often not sufficiently validated scientifically and are not yet applied in clinical routine.


Assuntos
Inteligência Artificial , Cardiopatias , Humanos , Reprodutibilidade dos Testes , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Cardiopatias/diagnóstico por imagem
20.
In Vivo ; 36(5): 2323-2331, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36099133

RESUMO

BACKGROUND/AIM: To investigate whether quantitative analysis of diffusion weighted images allows for improved risk stratification of transition zone lesions in prostate magnetic resonance imaging (MRI) evaluated according to PI-RADSv2.1 [Prostate Imaging Reporting and Data System, target variable: clinically significant prostate cancer (csPCa)]. PATIENTS AND METHODS: Consecutive patients with transition zone lesions in 3T prostate MRI were enrolled in the study. All lesions on MRI were histopathologically verified by transperineal MRI-TRUS fusion biopsy. Two blinded radiologists re-evaluated all lesions according to PI-RADSv2.1. A consensus reading was performed after reading of all cases. Additionally, mean apparent diffusion coefficient values (mADC) were derived from blinded lesion segmentation. ROC analysis was performed for PI-RADS categories and PI-RADS categories with separate subcategories and diffusion coefficient values (ADC). Data were examined for optimal mADC cut-off values that improve stratification of csPCa and benign lesions. RESULTS: Among 85 patients (mean age=66.2 years), 98 transition zone lesions were detected. Biopsy confirmed csPCa in 24/98 cases. Area under the curve (AUC) was 0.89/0.90 for reader 1, 0.92/0.91 for reader 2 and 0.92/0.91 for the consensus reading (5 category analysis/analysis with subcategories separately). Inter-reader agreement was substantial, with lower PI-RADS categories assigned by the more experienced reader (p<0.05). AUC for mADC alone was 0.81. When a cut-off threshold of 950 µm2/s mADC is used to downgrade PI-RADS 3 lesions to PI-RADS 2, biopsy could be avoided in all benign PI-RADS 3 cases. CONCLUSION: Quantitative analysis of diffusion weighted images may help avoid unnecessary biopsies of transition zone PI-RADS 3 lesions.


Assuntos
Próstata , Neoplasias da Próstata , Idoso , Humanos , Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética , Masculino , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA