Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 30(Pt 4): 708-716, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37255023

RESUMO

Differential deposition by DC magnetron sputtering was applied to correct for figure errors of X-ray mirrors to be deployed on low-emittance synchrotron beamlines. During the deposition process, the mirrors were moved in front of a beam-defining aperture and the required velocity profile was calculated using a deconvolution algorithm. The surface figure was characterized using conventional off-line visible-light metrology instrumentation (long trace profiler and Fizeau interferometer) before and after the deposition. WSi2 was revealed to be a promising candidate material since it conserves the initial substrate surface roughness and limits the film stress to acceptable levels. On a 300 mm-long flat Si mirror the average height errors were reduced by a factor of 20 down to 0.2 nm root mean square. This result shows the suitability of WSi2 for differential deposition. Potential promising applications include the upgrade of affordable, average-quality substrates to the standards of modern synchrotron beamlines.


Assuntos
Algoritmos , Síncrotrons , Raios X , Radiografia
2.
J Synchrotron Radiat ; 27(Pt 4): 1074-1079, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-33566018

RESUMO

A helium mini-cryostat has been developed for the hard X-ray nanoprobe ID16B of the European Synchrotron to collect X-ray excited optical luminescence and X-ray fluorescence at low temperature (<10 K). The mini-cryostat has been specifically designed to fit within the strong space restrictions and high-demanding mechanical constraints imposed by the beamline to provide vibration-free operation and maximal thermal stability. This paper reports the detailed design, architecture and technical requirements of the mini-cryostat, and presents the first experimental data measured using the cryogenic equipment. The resulting cryo-system features ultimate thermal stability, fast cool-down and ultra-low vibrations. The simultaneous X-ray fluorescence and X-ray excited optical luminescence data acquired from bulk GaN and core/shell InGaN/GaN multi-quantum wells validated the excellent performance of the cryostat with ultimate resolution, stability and sensitivity.

3.
J Synchrotron Radiat ; 26(Pt 6): 1872-1878, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31721729

RESUMO

The surface figure error of a hard X-ray mirror was improved by combining differential deposition and off-line metrology tools. Thin Cr layers were deposited on flat substrates by DC magnetron sputtering. The substrates were moved in front of a beam-defining aperture. The required velocity profile was calculated using a deconvolution algorithm. The Cr thickness profiles were measured directly using hard X-ray reflectivity data. The surface figure was characterized using conventional visible-light metrology instrumentation (long trace profiler) before and after the deposition. The method converges quickly, and after two iterations the mirror surface figure had improved by a factor of 7. The surface roughness evolves with increasing Cr thickness and deteriorates the quality of subsequent multilayer coatings. The mirror curvature can change upon coating, which complicates the interpretation of the surface metrology data. In this context, the role of layer stress is discussed. Potential improvements of the process are also proposed.

4.
J Synchrotron Radiat ; 23(1): 344-52, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26698084

RESUMO

Within the framework of the ESRF Phase I Upgrade Programme, a new state-of-the-art synchrotron beamline ID16B has been recently developed for hard X-ray nano-analysis. The construction of ID16B was driven by research areas with major scientific and societal impact such as nanotechnology, earth and environmental sciences, and bio-medical research. Based on a canted undulator source, this long beamline provides hard X-ray nanobeams optimized mainly for spectroscopic applications, including the combination of X-ray fluorescence, X-ray diffraction, X-ray excited optical luminescence, X-ray absorption spectroscopy and 2D/3D X-ray imaging techniques. Its end-station re-uses part of the apparatus of the earlier ID22 beamline, while improving and enlarging the spectroscopic capabilities: for example, the experimental arrangement offers improved lateral spatial resolution (∼50 nm), a larger and more flexible capability for in situ experiments, and monochromatic nanobeams tunable over a wider energy range which now includes the hard X-ray regime (5-70 keV). This paper describes the characteristics of this new facility, short-term technical developments and the first scientific results.

5.
J Synchrotron Radiat ; 19(Pt 1): 10-8, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22186639

RESUMO

The ESRF synchrotron beamline ID22, dedicated to hard X-ray microanalysis and consisting of the combination of X-ray fluorescence, X-ray absorption spectroscopy, diffraction and 2D/3D X-ray imaging techniques, is one of the most versatile instruments in hard X-ray microscopy science. This paper describes the present beamline characteristics, recent technical developments, as well as a few scientific examples from recent years of the beamline operation. The upgrade plans to adapt the beamline to the growing needs of the user community are briefly discussed.


Assuntos
Síncrotrons/instrumentação , Arsenitos/análise , Núcleo Celular/química , Citosol/química , Dano ao DNA/efeitos dos fármacos , Microanálise por Sonda Eletrônica , Complexo de Golgi/fisiologia , Células Hep G2 , Humanos , Manganês/metabolismo , Mitocôndrias/química , Nanopartículas/uso terapêutico , Espectrometria por Raios X/métodos , Espectroscopia por Absorção de Raios X/métodos , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA