Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Am Soc Echocardiogr ; 32(6): 708-719.e1, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30948144

RESUMO

BACKGROUND: Left atrial appendage (LAA) occlusion is an alternative to anticoagulation for stroke prevention in patients with atrial fibrillation. Accurate device sizing is crucial for optimal outcome. Patient-specific LAA models can be created using three-dimensional (3D) printing from 3D transesophageal echocardiographic (TEE) images, allowing in vitro model testing for device selection. The aims of this study were to assess the association of model-based device selection with procedural safety and efficacy and to determine if preprocedural model testing leads to superior outcomes. METHODS: In 72 patients who underwent imaging-guided LAA occlusion, 3D models of the LAA were created from 3D TEE data sets retrospectively (retrospective cohort). The optimal device determined by in vitro model testing was compared with the actual device used. Associations of model-match and model-mismatch device sizing with outcomes were analyzed. In another 32 patients, device selection was prospectively guided by 3D models in adjunct to imaging (prospective cohort). The impact of model-based sizing on outcomes was assessed by comparing the two cohorts. RESULTS: Patients in the retrospective cohort with model-mismatch sizing had longer procedure times, more implantation failures, more devices used per procedure, more procedural complications, more peridevice leak, more device thrombus, and higher cumulative incidence rates of ischemic stroke and cardiovascular or unexplained death (P < .05 for all) over 3.0 ± 2.3 years after LAA occlusion. Compared with the retrospective imaging-guided cohort, the prospective model-guided patients achieved higher implantation success and shorter procedural times (P < .05) without complications. Clinical device compression (r = 0.92) and protrusion (r = 0.95) agreed highly with model testing (P < .0001). Predictors for sizing mismatch were nonwindsock morphology (odds ratio, 4.7) and prominent LAA trabeculations (odds ratio, 7.1). CONCLUSIONS: In patients undergoing LAA occlusion, device size selection in agreement with 3D-printed model-based sizing is associated with improved safety and efficacy. Preprocedural device sizing with 3D models in adjunct to imaging guidance may lead to superior outcomes.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Impressão Tridimensional , Acidente Vascular Cerebral/prevenção & controle , Cirurgia Assistida por Computador , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Procedimentos Cirúrgicos Cardíacos/métodos , Estudos de Coortes , Bases de Dados Factuais , Ecocardiografia Transesofagiana/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Modelos Cardiovasculares , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Resultado do Tratamento
2.
World Neurosurg ; 116: 77-87, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29730102

RESUMO

The development of stereotaxy can be dated back 100 years. However, most stereotactic neurosurgery still relies on the workflow established about half a century ago. With the arrival of computer-assisted navigation, numerous studies to improve the neurosurgical technique have been reported, leading to frameless and magnetic resonance imaging (MRI)-guided/verified techniques. Frameless stereotaxy has been proved to be comparable to frame-based stereotaxy in accuracy, diagnostic yield, morbidity, and mortality. The incorporation of intraoperative MRI guidance in frameless techniques is considered an appealing method that could simplify workflow by reducing coregistration errors in different imaging modalities, conducting general anesthesia, and monitoring the surgical progress. In light of this situation, manually operated platforms have emerged for MRI-guided frameless procedures. However, these procedures could still be complicated and time-consuming because of the intensive manual operation required. To further simplify the procedure and enhance accuracy, robotics was introduced. Robots have superior capabilities over humans in certain tasks, especially those that are limited by space, accuracy demanding, intensive, and tedious. Clinical benefits have been shown in the recent surge of robot-assisted surgical interventions. We review the state-of-the-art intraoperative MRI-guided robotic platforms for stereotactic neurosurgery. To improve the surgical workflow and achieve greater clinical penetration, 3 key enabling techniques are proposed with emphasis on their current status, limitations, and future trends.


Assuntos
Cuidados Intraoperatórios/tendências , Imageamento por Ressonância Magnética/tendências , Procedimentos Neurocirúrgicos/tendências , Procedimentos Cirúrgicos Robóticos/tendências , Técnicas Estereotáxicas/tendências , Animais , Humanos , Cuidados Intraoperatórios/instrumentação , Cuidados Intraoperatórios/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Procedimentos Neurocirúrgicos/instrumentação , Procedimentos Neurocirúrgicos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Técnicas Estereotáxicas/instrumentação , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/tendências