Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 34(2): 389-399, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36335623

RESUMO

INTRODUCTION: Scar-related ventricular tachycardia (VT) usually results from an underlying reentrant circuit facilitated by anatomical and functional barriers. The later are sensitive to the direction of ventricular activation wavefronts. We aim to evaluate the impact of different ventricular activation wavefronts on the functional electrophysiological properties of myocardial tissue. METHODS: Patients with ischemic heart disease referred for VT ablation underwent high-density mapping using Carto®3 (Biosense Webster). Maps were generated during sinus rhythm, right and left ventricular pacing, and analyzed using a new late potential map software, which allows to assess local conduction velocities and facilitates the delineation of intra-scar conduction corridors (ISCC); and for all stable VTs. RESULTS: In 16 patients, 31 high-resolution substrate maps from different ventricular activation wavefronts and 7 VT activation maps were obtained. Local abnormal ventricular activities (LAVAs) were found in VT isthmus, but also in noncritical areas. The VT isthmus was localized in areas of LAVAs overlapping surface between the different activation wavefronts. The deceleration zone location differed depending on activation wavefronts. Sixty-six percent of ISCCs were similarly identified in all activating wavefronts, but the one acting as VT isthmus was simultaneously identified in all activation wavefronts in all cases. CONCLUSION: Functional based substrate mapping may improve the specificity to localize the most arrhythmogenic regions within the scar, making the use of different activation wavefronts unnecessary in most cases.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Cicatriz/diagnóstico , Cicatriz/etiologia , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
2.
J Cardiovasc Electrophysiol ; 33(6): 1211-1222, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35338745

RESUMO

BACKGROUND: Automated systems for substrate mapping in the context of ventricular tachycardia (VT) ablation may annotate far-field rather than near-field signals, rendering the resulting maps hard to interpret. Additionally, quantitative assessment of local conduction velocity (LCV) remains an unmet need in clinical practice. We evaluate whether a new late potential map (LPM) algorithm can provide an automatic and reliable annotation and localized bipolar voltage measurement of ventricular electrograms (EGMs) and if LCV analysis allows recognizing intrascar conduction corridors acting as VT isthmuses. METHODS: In 16 patients referred for scar-related VT ablation, 8 VT activation maps and 29 high-resolution substrate maps from different activation wavefronts were obtained. In offline analysis, the LPM algorithm was compared to manually annotated substrate maps. Locations of the VT isthmuses were compared with the corresponding substrate maps in regard to LCV. RESULTS: The LPM algorithm had an overall/local abnormal ventricular activity (LAVA) annotation accuracy of 94.5%/81.1%, which compares to 83.7%/23.9% for the previous wavefront algorithm. The resultant maps presented a spatial concordance of 88.1% in delineating regions displaying LAVA. LAVA median localized bipolar voltage was 0.22 mV, but voltage amplitude assessment had modest accuracy in distinguishing LAVA from other abnormal EGMs (area under the curve: 0.676; p < .001). LCV analysis in high-density substrate maps identified a median of two intrascar conduction corridors per patient (interquartile range: 2-3), including the one acting as VT isthmus in all cases. CONCLUSION: The new LPM algorithm and LCV analysis may enhance substrate characterization in scar-related VT.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Algoritmos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cicatriz/diagnóstico , Cicatriz/etiologia , Frequência Cardíaca , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
3.
Pacing Clin Electrophysiol ; 44(10): 1701-1710, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34409630

RESUMO

BACKGROUND: Cavotricuspid isthmus (CTI) ablation in typical atrial flutter (AFL) restores sinus rhythm in 95% of patients, which may lead to the discontinuation of oral anticoagulation during follow-up. Therefore, we aimed to systematically review the clinical impact of oral anticoagulation in the incidence of thromboembolic events (TE) after typical AFL ablation. METHODS: We searched for controlled studies evaluating the impact of anticoagulation in the incidence of TE in patients submitted to AFL ablation in MEDLINE, CENTRAL, PsycINFO database (June/2021). The primary outcome was TE events (ischemic stroke or systemic embolism). A meta-analysis was performed deriving risk ratios (RR) and 95% confidence intervals (CI). Statistical heterogeneity was measured through I2 metric. The confidence in the evidence was appraised with Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework. RESULTS: Eight observational studies with 4870 patients were included. TE events were not significantly reduced (RR 1.18, 95% CI 0.59-2.36; n = 4870; GRADE very low). A meta-regression showed that for each 10% increase in the prevalence of previous AF in the studied population, anticoagulation reduced TE risk in 32%. There were no significant differences regarding bleeding events (RR 2.16, 95% CI 0.43-10.97, I2  = 0%; GRADE low), but there was a lower all-cause mortality (RR 0.24, 95% CI 0.17-0.32, GRADE low). CONCLUSION: The best available evidence lacks robustness and the data did not definitely associate anticoagulation after typical AFL ablation with reduced TE.


Assuntos
Anticoagulantes/administração & dosagem , Flutter Atrial/cirurgia , Ablação por Cateter , Complicações Pós-Operatórias/prevenção & controle , Tromboembolia/prevenção & controle , Administração Oral , Humanos
4.
J Cardiovasc Electrophysiol ; 31(11): 2954-2963, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32945049

RESUMO

BACKGROUND: Left ventricular (LV) lead placement is the most challenging aspect of cardiac resynchronization therapy (CRT) device implantation, with a failure rate of up to 10% due to complex coronary anatomies. We describe a modified snare technique for LV lead placement and evaluate its safety and efficacy in cases when standard methods fail. METHODS AND RESULTS: A prospective study was conducted of patients indicated for a CRT implant. When LV lead delivery to the target vessel failed using standard techniques, a modified snare technique was employed. Patients were evaluated every 6 months. From 2015 to 2019, 566 CRTs were implanted (26.1% female, 72 ± 10.2 years old, follow-up duration 18.9 ± 15.8 months). The standard LV implant technique failed in 94 cases (16.6%), of which the modified snare technique was successful in 92 (97.9%). There were no differences between the modified snare and standard techniques in the rates of 30-day postimplant CRT all-cause mortality (3.2% vs. 1.7%, p = .33), 4-year all-cause mortality (15.9% vs. 15.5%, p = .49), or major acute complications (7.4% vs. 3.8%, p = .12). However, the 4-year procedural reintervention rate was lower with the modified snare technique (3.2% vs. 10.2%, p < .05), specifically LV implant failure or dislodgement rates (0% vs. 5.3%, p < .05), improving the response rate (71.8% vs. 55.1%, p < .05). CONCLUSIONS: For challenging coronary sinus anatomies that preclude LV lead placement by standard methods, this modified snare alternative was safe and effective, with comparable mortality and complications, but significantly lower procedural reintervention and higher response rates.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/efeitos adversos , Dispositivos de Terapia de Ressincronização Cardíaca , Criança , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
5.
Europace ; 20(6): 986-992, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-28430960

RESUMO

Aims: Cardiac Resynchronization Therapy (CRT) is associated with a particularly high non-response rate in patients with atrial fibrillation (AF). We aimed to assess the effectiveness of triple-site (Tri-V) pacing CRT in this population. Methods and results: Prospective observational study of patients with permanent AF who underwent CRT implantation with an additional right ventricle lead in the outflow tract septal wall. After implantation, programming mode (Tri-V or biventricular pacing) was selected based on cardiac output determination. Patients were classified as responders if NYHA class was reduced by at least one level and echocardiographic ejection fraction (EF) increased ≥ 10%, and as super-responders if in NYHA class I and EF ≥ 50%. Forty patients (93% male, mean age 72 ± 10 years) were included. Thirty-three were programmed in Tri-V. The following results pertain to this subgroup. At baseline, 58% were in NYHA class III and 36% NYHA class II. At 1 year follow-up, Minnesota QoL score was reduced (36 ± 23 vs. 8 ± 6; P = 0.001) and the 6MWT distance improved (384 ± 120 m to 462 ± 87 m, P = 0.003). Mean EF increased (26% ± 8 vs. 39 ± 10; P < 0.001 at 6 months and 41 ± 10; P < 0.001 at 12 months). Responder rate was 59% at 6 months and 79% at 12 months. Super-responder rate was 9% at 6 months and 16% at 12 months. One year survival free from heart failure hospitalization was 87.9%. Conclusion: Tri-V CRT yielded higher response and super-response rates than usually reported for CRT in patients with permanent AF using clinical and remodeling criteria.


Assuntos
Fibrilação Atrial , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Ecocardiografia/métodos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Portugal , Ajuste de Prótese/métodos , Risco Ajustado/métodos , Fatores de Risco , Volume Sistólico , Resultado do Tratamento
7.
Rev Port Cardiol ; 42(4): 385-389, 2023 04.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36893834

RESUMO

Ablation of atypical left atrial flutters (LAF) is very challenging due to the complexity of the underlying atrial substrate and diverse arrhythmia mechanisms. The interpretation of the arrhythmia mechanism is usually difficult, even using advanced three-dimensional (3D) mapping systems. SparkleMap is a novel mapping algorithm that displays each electrogram as a green dot that lights up at the point corresponding to the local activation time, superimposed either on the substrate or the local activation time 3D-maps. It is not affected by the setting of the "window of interest" and there is no need for user post-processing. We present the case of patient with a persistent atypical LAF in whom we tested the concept of complex arrhythmia interpretation exclusively based on the analysis of the substrate and evaluation of SparkleMap-derived wavefront propagation. We describe the workflow for map collection and the systematic approach for arrhythmia interpretation that resulted in the identification of a dual loop perimitral mechanism with a common slow conducting isthmus inside a scar at the septum/anterior atrial wall. This new method of analysis enabled the use of a specifically targeted and precise approach for ablation, with restoration of sinus rhythm within five seconds of radiofrequency application. After 18 months of follow-up, the patient remains free from recurrences, without anti-arrhythmic medication. This case report exemplifies how helpful new mapping algorithms can be in the interpretation of the arrhythmia mechanism in patients with complex LAF. It also suggests an innovative workflow to integrate the SparkleMap into the mapping approach.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Humanos , Flutter Atrial/cirurgia , Flutter Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração , Apêndice Atrial/cirurgia , Resultado do Tratamento
8.
Rev Port Cardiol ; 41(4): 325-335, 2022 Apr.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36062666

RESUMO

INTRODUCTION AND OBJECTIVE: Radiofrequency catheter ablation (RCA) for ventricular tachycardia (VT) in patients with ischemic heart disease (IHD) is associated with a reduced risk of VT storm and implantable cardioverter defibrillator (ICD) shocks. We aim to report the outcome after a single RCA procedure for VT in patients with IHD using a high-density substrate-based approach. METHODS: We conducted a prospective, observational, single-center and single-arm study involving patients with IHD, referred for RCA procedure for VT using high-density mapping catheters. Substrate mapping was performed in all patients. Procedural endpoints were VT non-inducibility and local abnormal ventricular activities (LAVAs) elimination. The primary end point was survival free from appropriate ICD shocks and secondary end points included VT storm and all-cause mortality. RESULTS: Sixty-four consecutive patients were included (68±9 years, 95% male, mean ejection fraction 33±11%, 39% VT storms, and 69% appropriate ICD shocks). LAVAs were identified in all patients and VT inducibility was found in 83%. LAVA elimination and non-inducibility were achieved in 93.8% and 60%, respectively. After a mean follow-up of 25±18 months, 90% and 85% of patients are free from appropriate ICD shocks at one and two years, respectively. The proportion of patients experiencing VT storm decreased from 39% to 1.6%. Overall survival was 89% and 84% at one and two years, respectively. CONCLUSIONS: RCA of VT in IHD using a high-density mapping substrate-based approach resulted in a steady freedom of ICD shocks and VT storm.

9.
Vascul Pharmacol ; 142: 106929, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34757209

RESUMO

BACKGROUND: Post-operative atrial fibrillation (POAF) is a relevant complication after surgery. Several studies have shown that POAF has important consequences for long-term morbidity and mortality, by increasing the risk of thromboembolic events. However, the use of oral anticoagulation (OAC) is not well established in this context. METHODS: We searched MEDLINE, CENTRAL, PsycInfo and Web of Science for clinical trials and observational studies evaluating anticoagulation vs. no anticoagulation in patients with POAF (after cardiac or non-cardiac surgery). Data were screened and extracted by two independent reviewers. We performed a random- effects model to estimate the pooled odds ratio (OR) with 95% Confidence Intervals (CI), and heterogeneity was evaluated by I2 statistics. The outcomes of interest were all-cause mortality, thromboembolic events, and bleeding events. RESULTS: Overall, 10 observational retrospective studies were included: 5 studies with 203,946 cardiac surgery POAF patients, and 5 studies with 29,566 patients with POAF after non-cardiac surgery. In cardiac surgery POAF, the OAC use was associated with lower risk of thromboembolic events (OR 0.68; 95%CI 0.47-0.96, I2 = 31%; 4 studies) and the bleeding risk was significantly increased (OR 4.30; 95%CI 3.69 to 5.02, 1 study). In non-cardiac surgery POAF, OAC did not significantly reduce the risk of thromboembolic events (OR 0.71, 95%CI 0.33-1.15; I2 = 79%; 5 studies) but was associated with increased risk of bleeding (OR 1.20, 95%CI 1.10-1.32, I2 = 0%; 3 studies). Mortality was not significantly reduced in both cardiac and non-cardiac surgery POAF. CONCLUSION: Oral anticoagulation was associated with a lower risk of thromboembolic events in patients with POAF following cardiac surgery but not in non-cardiac surgery. Bleeding risk was increased in both settings. The confidence on pooled results is at most low, and further data, namely randomized controlled trials are necessary to derive robust conclusions.


Assuntos
Fibrilação Atrial , Tromboembolia , Anticoagulantes/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/etiologia , Humanos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos , Fatores de Risco , Tromboembolia/etiologia , Tromboembolia/prevenção & controle
11.
J Interv Card Electrophysiol ; 59(3): 603-616, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32948937

RESUMO

PURPOSE: Ventricular tachycardia (VT) is a frequent cause of mortality and morbidity in patients with ischemic heart disease (IHD). We aim to perform a systematic review and meta-analysis of randomized controlled trials (RCT) of radiofrequency catheter ablation (RCA) of VT in patients with IHD and to discuss its appropriate timing and limitations. METHODS: Literature searches of MEDLINE, CENTRAL, the Cochrane Database of Systematic Reviews, Health Technology Assessment, and PsycINFO were performed in February 2020. RCTs comparing RCA vs conventional management for VT in patients with IHD and previous or planned implantable cardioverter defibrillator (ICD) were identified. Clinical outcomes included all-cause mortality, cardiovascular mortality, cardiovascular hospitalization, VT storm, recurrent VT/ventricular fibrillation (VF), appropriate ICD therapies, and appropriate ICD shocks. Using a random-effects model, relative risk (RR) and 95% confidence intervals (CI) were calculated for each outcome. RESULTS: A total of 6 RCTs (N = 791) met inclusion criteria. RCA was associated with significantly lower VT storm (RR 0.70; CI95% 0.51 to 0.94, p = 0.02) and appropriate ICD therapies (RR 0.69; CI95% 0.54 to 0.88, p = 0.003), including appropriate ICD shocks (RR 0.66; CI95% 0.47 to 0.92, p = 0.02). There was no significant difference in all-cause or cardiovascular mortality, cardiovascular hospitalization, and recurrent VT/VF. CONCLUSIONS: Radiofrequency catheter ablation for VT in patients with IHD was associated with a reduced risk of VT storm, ICD therapies, and ICD shocks. There is a need for future carefully designed RCTs that incorporate improved RCA procedural aspects.


Assuntos
Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Desfibriladores Implantáveis , Humanos , Isquemia Miocárdica/complicações , Isquemia Miocárdica/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
12.
Amyloid ; 27(3): 174-183, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32482106

RESUMO

Background: There is a growing need for a non-invasive test to detect cardiac involvement in patients with transthyretin-related hereditary amyloidosis (ATTR) caused by V30M mutation. 99mTc-3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) scintigraphy is a promising method, but its accuracy in this particular mutation remains unknown.Methods: A cohort of 179 patients: 92 with early-onset disease (EoD, symptoms <50-years-old), 33 with late-onset disease (LoD) and 54 asymptomatic carriers were prospectively evaluated and underwent DPD scintigraphy, which was compared with the results of echocardiogram, ambulatory blood pressure monitoring, 24 h-Holter, myocardial 123I-metaiodobenzylguanidine imaging and NT-proBNP.Results: Amyloid cardiomyopathy, defined as septal thickness ≥13 mm, was present in 32 patients (17.9%) and was more frequent in those with LoD (OR: 3.68, p = .003). Cardiac DPD uptake was present in 22 individuals (12.3%) and correlated with parameters indicative of cardiac amyloidosis. DPD imaging was strongly influenced by the age of disease onset: among patients with myocardial thickening, cardiac DPD retention was present in 11/15 (73.3%) with LoD, in contrast to only 4/17 (26.7%) with EoD (p = .005). Two patients with myocardial thickening and normal DPD scintigraphy underwent endomyocardial biopsy that confirmed ATTR amyloidosis.Conclusion: DPD scintigraphy presents suboptimal sensitivity to detect cardiac involvement in ATTRV30M, particularly in symptomatic patients with EoD.


Assuntos
Neuropatias Amiloides Familiares/diagnóstico , Miocárdio/metabolismo , Pré-Albumina/genética , Cintilografia , Adamantano/administração & dosagem , Adamantano/análogos & derivados , Adulto , Neuropatias Amiloides Familiares/genética , Neuropatias Amiloides Familiares/patologia , Monitorização Ambulatorial da Pressão Arterial , Feminino , Variação Genética/genética , Coração/efeitos dos fármacos , Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Mutação/genética , Miocárdio/patologia , Pré-Albumina/isolamento & purificação
13.
Rev Port Cardiol (Engl Ed) ; 38(5): 385.e1-385.e4, 2019 May.
Artigo em Inglês, Português | MEDLINE | ID: mdl-31256796

RESUMO

Ripple mapping is a novel, three-dimensional, electroanatomic mapping tool that displays each electrogram at its corresponding 3-dimensional coordinate as a dynamic moving bar, which changes in length according to the electrogram voltage-time relationship. We present the case of a 43-year-old male patient with surgically repaired Ebstein's anomaly who previously underwent two unsuccessful ablation procedures for right atrial flutter (cavotricuspid isthmus and intercaval lines). Ripple mapping was decisive, enabling the arrhythmia mechanism to be appropriately recognized, and a distinction to be made between critical areas of the circuit and delayed activated bystander regions.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Anomalia de Ebstein/complicações , Imageamento Tridimensional , Taquicardia por Reentrada no Nó Sinoatrial/diagnóstico , Adulto , Ablação por Cateter/métodos , Anomalia de Ebstein/diagnóstico , Anomalia de Ebstein/cirurgia , Humanos , Masculino , Taquicardia por Reentrada no Nó Sinoatrial/etiologia , Taquicardia por Reentrada no Nó Sinoatrial/cirurgia
14.
Rev Port Cardiol (Engl Ed) ; 37(2): 201.e1-201.e3, 2018 Feb.
Artigo em Inglês, Português | MEDLINE | ID: mdl-29398393

RESUMO

Persistence of the left superior vena cava occurs in about 0.3-0.7% of the general population. It is of particular importance in patients who need cardiac resynchronisation therapy. We present a unique case in which a snare system and tunnelling tool were used to place the left ventricular lead in a patient with persistence of the left superior vena cava.


Assuntos
Desfibriladores Implantáveis , Veia Cava Superior/anormalidades , Idoso , Humanos , Masculino , Implantação de Prótese/métodos
15.
Rev Port Cardiol (Engl Ed) ; 37(3): 265.e1-265.e5, 2018 Mar.
Artigo em Inglês, Português | MEDLINE | ID: mdl-29622376

RESUMO

We present the case of a previously healthy 42-year-old man who attended the emergency department due to a sudden onset of rapid and regular palpitations. The ECG showed 190 bpm, wide QRS with left bundle branch block tachycardia. He was started on amiodarone with progression to 230 bpm, wide QRS tachycardia with multiple morphologies, followed by spontaneous conversion to sinus rhythm, normal PR interval and rS pattern in LIII. The echocardiogram was negative for structural heart disease. The electrophysiological study demonstrated the presence of an accessory pathway with anterograde decremental conduction and no retrograde conduction. Both episodes of clinical tachycardia were induced. A diagnosis of Mahaim fiber-mediated antidromic atrioventricular reentrant tachycardia and pre-excited atrial fibrillation was made. Mapping was performed with detection of an M potential (His-like) at the lateral region of the tricuspid ring followed by radiofrequency ablation with immediate success criteria. Post-ablation there was a change to a qR pattern in LIII. At 12-months follow-up there was no recurrence of the tachycardia.


Assuntos
Feixe Acessório Atrioventricular , Taquicardia/etiologia , Adulto , Eletrocardiografia , Humanos , Masculino , Taquicardia/fisiopatologia
16.
Rev Port Cardiol ; 36(5): 333-340, 2017 May.
Artigo em Inglês, Português | MEDLINE | ID: mdl-28479268

RESUMO

INTRODUCTION: Familial amyloid polyneuropathy (FAP) is a rare disease caused by systemic deposition of amyloidogenic variants of the transthyretin (TTR) protein. The TTR-V30M mutation is caused by the substitution of valine by methionine at position 30 and mainly affects the peripheral and autonomic nervous systems. Cardiovascular manifestations are common and are due to autonomic denervation and to amyloid deposition in the heart. Cardiac sympathetic denervation detected by iodine-123 labeled metaiodobenzylguanidine (MIBG) is an important prognostic marker in TTR-V30M FAP. Liver transplantation, widely used to halt neurological involvement, appears to have a varying effect on the progression of amyloid cardiomyopathy. Its effect on the progression of cardiac denervation remains unknown. METHODS: In this observational study, patients with the TTR-V30M mutation underwent annual cardiac assessment and serial MIBG imaging with quantification of the late heart-to-mediastinum (H/M) ratio. RESULTS: We studied 232 patients (median age 40 years, 54.7% female, 37.9% asymptomatic at the time of inclusion) who were followed for a median of 4.5 years and underwent a total of 558 MIBG scans. During follow-up, 47 patients (20.3%) died. MIBG scintigraphy at inclusion was a strong predictor of prognosis, with the risk of death increasing by 27.8% for each one-tenth reduction in the late H/M ratio. The late H/M ratio decreased with age (0.082/year, p<0.001), but progression of cardiac denervation was so slow that annual repetition of MIBG imaging did not increase its prognostic accuracy. During follow-up, 70 symptomatic patients underwent liver transplantation. The late H/M ratio decreased by 0.19/year until transplantation but no statistically significant differences were detected after the procedure. CONCLUSIONS: Cardiac denervation is common during the progression of TTR-V30M FAP and quantification of the late H/M ratio on MIBG scintigraphy is valuable for prognostic stratification of these patients. Liver transplantation stabilizes cardiac denervation, without recovery or further deterioration in cardiac MIBG uptake after the procedure.


Assuntos
3-Iodobenzilguanidina , Neuropatias Amiloides Familiares/complicações , Doenças do Sistema Nervoso Autônomo/diagnóstico por imagem , Doenças do Sistema Nervoso Autônomo/prevenção & controle , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/prevenção & controle , Transplante de Fígado , Compostos Radiofarmacêuticos , Adulto , Doenças do Sistema Nervoso Autônomo/etiologia , Cardiomiopatias/etiologia , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia
17.
Rev Port Cardiol ; 35(6): 331-8, 2016 Jun.
Artigo em Inglês, Português | MEDLINE | ID: mdl-27255170

RESUMO

INTRODUCTION AND AIM: Multi-site pacing is emerging as a new method for improving response to cardiac resynchronization therapy (CRT), but has been little studied, especially in patients with atrial fibrillation. We aimed to assess the effects of triple-site (Tri-V) vs. biventricular (Bi-V) pacing on hemodynamics and QRS duration. METHODS: This was a prospective observational study of patients with permanent atrial fibrillation and ejection fraction <40% undergoing CRT implantation (n=40). One right ventricular (RV) lead was implanted in the apex and another in the right ventricular outflow tract (RVOT) septal wall. A left ventricular (LV) lead was implanted in a conventional venous epicardial position. Cardiac output (using the FloTrac™ Vigileo™ system), mean QRS and ejection fraction were calculated. RESULTS: Mean cardiac output was 4.81±0.97 l/min with Tri-V, 4.68±0.94 l/min with RVOT septal and LV pacing, and 4.68±0.94 l/min with RV apical and LV pacing (p<0.001 for Tri-V vs. both BiV). Mean pre-implantation QRS was 170±25 ms, 123±18 ms with Tri-V, 141±25 ms with RVOT septal pacing and LV pacing and 145±19 with RV apical and LV pacing (p<0.001 for Tri-V vs. both BiV and pre-implantation). Mean ejection fraction was significantly higher with Tri-V (30±11%) vs. Bi-V pacing (28±12% with RVOT septal and LV pacing and 28±11 with RV apical and LV pacing) and pre-implantation (25±8%). CONCLUSION: Tri-V pacing produced higher cardiac output and shorter QRS duration than Bi-V pacing. This may have a significant impact on the future of CRT.


Assuntos
Fibrilação Atrial/terapia , Terapia de Ressincronização Cardíaca , Estimulação Cardíaca Artificial , Eletrocardiografia , Insuficiência Cardíaca , Humanos , Estudos Prospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA