Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 93(4): 2097-2105, 2021 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-33464825

RESUMO

In many countries targeting malaria elimination, persistent malaria infections can have parasite loads significantly below the lower limit of detection (LLOD) of standard diagnostic techniques, making them difficult to identify and treat. The most sensitive diagnostic methods involve amplification and detection of Plasmodium DNA by polymerase chain reaction (PCR), which requires expensive thermal cycling equipment and is difficult to deploy in resource-limited settings. Isothermal DNA amplification assays have been developed, but they require complex primer design, resulting in high nonspecific amplification, and show a decrease in sensitivity than PCR methods. Here, we have used a computational approach to design a novel isothermal amplification assay with a simple primer design to amplify P. falciparum DNA with analytical sensitivity comparable to PCR. We have identified short DNA sequences repeated throughout the parasite genome to be used as primers for DNA amplification and demonstrated that these primers can be used, without modification, to isothermally amplify P. falciparum parasite DNA via strand displacement amplification. Our novel assay shows a LLOD of ∼1 parasite/µL within a 30 min amplification time. The assay was demonstrated with clinical samples using patient blood and saliva. We further characterized the assay using direct amplicon next-generation sequencing and modified the assay to work with a visual readout. The technique developed here achieves similar analytical sensitivity to current gold standard PCR assays requiring a fraction of time and resources for PCR. This highly sensitive isothermal assay can be more easily adapted to field settings, making it a potentially useful tool for malaria elimination.


Assuntos
DNA de Protozoário/genética , Malária Falciparum/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , Plasmodium falciparum/genética , Sequências Repetitivas de Ácido Nucleico/genética , DNA de Protozoário/isolamento & purificação , Humanos , Limite de Detecção , Plasmodium falciparum/isolamento & purificação , Reprodutibilidade dos Testes
2.
Heliyon ; 10(6): e27344, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38533083

RESUMO

Background: Curable sexually transmitted infections (STIs), such as Neisseria gonorrhoeae (N. gonorrhoeae), are a major cause of poor pregnancy outcomes. The infection is often asymptomatic in pregnant women, and a syndrome-based approach of testing leads to a missed diagnosis. Culture followed by microscopy is inadequate and time-consuming. The gold standard nucleic acid amplification tests require advanced infrastructure settings, whereas point-of-care tests are limited to immunoassays with sensitivities and specificities insufficient to accurately diagnose asymptomatic cases. This necessitates the development and validation of assays that are fit for purpose. Methods: We identified new diagnostic target biomarker regions for N. gonorrhoeae using an algorithm for genome mining of identical multi-repeat sequences (IMRS). These were then developed as DNA amplification primers to design better diagnostic assays. To test the primer pair, genomic DNA was 10-fold serially diluted (100 pg/µL to 1 × 10-3 pg/µL) and used as DNA template for PCR reactions. The gold standard PCR using 16S rRNA primers was also run as a comparative test, and both assay products were resolved on 1% agarose gel. Results: Our newly developed N. gonorrhoeae IMRS-PCR assay had an analytical sensitivity of 6 fg/µL representing better sensitivity than the 16S rRNA PCR assay with an analytical sensitivity of 4.3096 pg/µL. The assay was also successfully validated using clinical urethral swab samples. We further advanced this technique by developing an isothermal IMRS, which was both reliable and sensitive for detecting cultured N. gonorrhoeae isolates at a concentration of 38 ng/µL. Combining isothermal IMRS with a low-cost lateral flow assay, we were able to detect N. gonorrhoeae amplicons at a starting concentration of 100 pg/µL. Conclusion: Therefore, there is a potential to implement this concept within miniaturized, isothermal, microfluidic platforms, and laboratory-on-a-chip diagnostic devices for highly reliable point-of-care testing.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA