RESUMO
Microplastics (MPs) have been reported in the outdoor/indoor air of urban centres, raising health concerns due to the potential for human exposure. Since aerosols are considered one of the routes of Coronavirus disease 2019 (COVID-19) transmission and may bind to the surface of airborne MPs, we hypothesize that severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) could be associated with the levels of MPs in the air. Our goal was to quantify the SARS-CoV-2 RNA and MPs present in the total suspended particles (TSP) collected in the area surrounding the largest medical centre in Latin America and to elucidate a possible association among weather variables, MPs, and SARS-CoV-2 in the air. TSP were sampled from three outdoor locations in the areas surrounding a medical centre. MPs were quantified and measured under a fluorescence microscope, and their polymeric composition was characterized by Fourier transform infrared (FT-IR) microspectroscopy coupled with attenuated total reflectance (ATR). The viral load of SARS-CoV-2 was quantified by an in-house real-time PCR assay. A generalized linear model (GzLM) was employed to evaluate the effect of the SARS-CoV-2 quantification on MPs and weather variables. TSP samples tested positive for SARS-CoV-2 in 22 out of 38 samples at the three sites. Polyester was the most frequent polymer (80%) found in the samples. The total amount of MPs was positively associated with the quantification of SARS-CoV-2 envelope genes and negatively associated with weather variables (temperature and relative humidity). Our findings show that SARS-CoV-2 aerosols may bind to TSP, such as MPs, and facilitate virus entry into the human body.
Assuntos
COVID-19 , SARS-CoV-2 , Aerossóis , Humanos , América Latina , Microplásticos , Plásticos , RNA Viral , Espectroscopia de Infravermelho com Transformada de FourierRESUMO
We quantified the presence of SARS-CoV-2 RNA in the air of different hospital settings and the autopsy room of the largest medical centre in Sao Paulo, Brazil. Real-time reverse-transcription PCR was used to determine the presence of the envelope protein of SARS-CoV-2 and the nucleocapsid protein genes. The E-gene was detected in 5 out of 6 samples at the ICU-COVID-19 ward and in 5 out of 7 samples at the ward-COVID-19. Similarly, in the non-dedicated facilities, the E-gene was detected in 5 out of 6 samples collected in the ICU and 4 out of 7 samples in the ward. In the necropsy room, 6 out of 7 samples were positive for the E-gene. When both wards were compared, the non-COVID ward presented a significantly higher concentration of the E-gene than in the COVID-19 ward (p = 0.003). There was no significant difference in E-gene concentration between the ICU-COVID-19 and the ICU (p = 0.548). Likewise, there was no significant difference among E-gene concentrations found in the autopsy room versus the ICUs and wards (dedicated or not) (p = 0.245). Our results show the widespread presence of aerosol contamination in different hospital units.