1.
PLoS One ; 17(3): e0265711, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35320307

RESUMO

PURPOSE: We describe the temporal concordance of 3 hemodynamic monitors. MATERIALS AND METHODS: Healthy volunteers performed preload changes while simultaneously wearing a non-invasive, pulse-contour stroke volume (SV) monitor, a bioreactance SV monitor and a wireless, wearable Doppler ultrasound patch over the common carotid artery. The sensitivity and specificity for detecting preload change over 3 temporal windows (early, middle and late) was assessed. RESULTS: 40 preload changes were recorded in total (20 increase, 20 decrease). Immediately, the wearable Doppler had high sensitivity (100%) and specificity (100%) for detecting preload change with an area under the receiver operator curve (AUROC) of 0.98 for both velocity time integral (VTI, 10.5% threshold) and corrected flow time (FTc, 2.5% threshold). The sensitivity, specificity and AUROC for non-invasive pulse contour were equally good (9% SV threshold). For bioreactance, a 13% SV threshold immediately detected preload change with a sensitivity, specificity and AUROC of 60%, 95% and 0.75, respectively. After two SV outputs following preload change, the sensitivity, specificity and AUROC of bioreactance improved to 70%, 90% and 0.85, respectively. CONCLUSIONS: Carotid Doppler ultrasound and non-invasive pulse contour detected rapid hemodynamic change with equal accuracy; bioreactance improved over time. Algorithm-lag should be considered when interpreting clinical studies.


Assuntos
Monitorização Hemodinâmica , Hemodinâmica , Humanos , Monitorização Fisiológica , Volume Sistólico , Ultrassonografia Doppler
2.
Mil Med ; 186(Suppl 1): 751-756, 2021 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-33499507

RESUMO

INTRODUCTION: Early hemorrhage is often missed by traditional vital signs because of physiological reserve, especially in the young and healthy. We have developed a novel, wearable, wireless Doppler ultrasound patch that tracks real-time blood velocity in the common carotid artery. MATERIALS AND METHODS: We studied eight healthy volunteers who decreased their cardiac output using a standardized Valsalva maneuver. In all eight, we simultaneously monitored the velocity time integral (VTI) of the common carotid artery (using the ultrasound patch) as well as the descending aorta (using a traditional pulsed wave duplex imaging system); the descending aortic VTI was used as a surrogate for left ventricular stroke volume (SV). Additionally, in a subset of four, we simultaneously measured SV using a noninvasive pulse contour analysis device. RESULTS: From baseline to peak effect of Valsalva, there was a statistically significant fall in descending aortic and common carotid VTI of 37% (P = 0.0005) and 23% (P < 0.0001), respectively. Both values returned to baseline on recovery. Additionally, a novel index from the carotid ultrasound patch (i.e., the heart rate divided by the carotid artery VTI) detected a 10% fall in aortic VTI with high sensitivity and specificity (100% and 100%, respectively); this novel index also accurately detected a 10% decrease in SV as measured by the noninvasive SV monitor. The mean arterial pressure, measured by the noninvasive pulse contour device, did not correctly detect the fall in SV. CONCLUSION: In summary, a novel index from a wireless Doppler ultrasound patch may be more sensitive and specific for detecting decreased cardiac output than standard vital signs in healthy volunteers.


Assuntos
Ultrassonografia Doppler , Adulto , Velocidade do Fluxo Sanguíneo , Débito Cardíaco , Estudos de Viabilidade , Voluntários Saudáveis , Humanos , Volume Sistólico
3.
Sci Rep ; 11(1): 7780, 2021 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-33833288

RESUMO

Quantitative Doppler ultrasound of the carotid artery has been proposed as an instantaneous surrogate for monitoring rapid changes in left ventricular output. Tracking immediate changes in the arterial Doppler spectrogram has value in acute care settings such as the emergency department, operating room and critical care units. We report a novel, hands-free, continuous-wave Doppler ultrasound patch that adheres to the neck and tracks Doppler blood flow metrics in the common carotid artery using an automated algorithm. String and blood-mimicking test objects demonstrated that changes in velocity were accurately measured using both manually and automatically traced Doppler velocity waveforms. In a small usability study with 22 volunteer users (17 clinical, 5 lay), all users were able to locate the carotid Doppler signal on a volunteer subject, and, in a subsequent survey, agreed that the device was easy to use. To illustrate potential clinical applications of the device, the Doppler ultrasound patch was used on a healthy volunteer undergoing a passive leg raise (PLR) as well as on a congestive heart failure patient at resting baseline. The wearable carotid Doppler patch holds promise because of its ease-of-use, velocity measurement accuracy, and ability to continuously record Doppler spectrograms over many cardiac and respiratory cycles.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Unidades de Terapia Intensiva , Testes Imediatos , Ultrassonografia Doppler/instrumentação , Adulto , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudo de Prova de Conceito
4.
Health Sci Rep ; 3(4): e190, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33033751

RESUMO

BACKGROUND AND AIMS: To test the feasibility of a novel, wearable carotid Doppler ultrasound to track changes in cardiac output induced by end-inspiratory and end-expiratory occlusion tests. METHODS: We observed the pattern of Doppler change of the common carotid artery during a simulated end-inspiratory and expiratory occlusion test (sEIOT/sEEOT) in 10, nonventilated, healthy subjects. Simultaneously, we measured the Doppler signal of the descending aorta using duplex ultrasound (Xario, Toshiba Medical Systems) and stroke volume (SV) using noninvasive pulse contour analysis (Clearsight, Edwards Lifesciences, Irvine, California). RESULTS: During sEIOT, SV, maximum velocity time integral (VTI) of the descending aorta, and common carotid fell by 25.7% (P = .0131), 26.1% (P < .0001), and 18.5% (P < .0001), respectively. During sEEOT, SV, maximum VTI of the descending aorta, and common carotid rose by: 41.3% (P = .0051), 28.3% (P < .0001), and 41.6% (P < .0001), respectively. There was good correlation between change in aortic VTI and carotid VTI (r 2 = 0.79); SV and aortic VTI (r 2 = 0.82), and SV and carotid VTI (r 2 = 0.95).The coefficient of variation of the VTI measured by the Doppler patch was roughly 60% less than that of the duplex system. CONCLUSIONS: The pattern of SV change induced by a sEIOT/sEEOT in nonmechanically ventilated volunteers is reflected in the common carotid artery and descending aorta. The VTI variability of the Doppler patch was less than that of the traditional, duplex Doppler.

5.
Intensive Care Med Exp ; 8(1): 54, 2020 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-32940808

RESUMO

BACKGROUND: Change of the corrected flow time (Ftc) is a surrogate for tracking stroke volume (SV) in the intensive care unit. Multiple Ftc equations have been proposed; many have not had their diagnostic characteristics for detecting SV change reported. Further, little is known about the inherent Ftc variability induced by the respiratory cycle. MATERIALS AND METHODS: Using a wearable Doppler ultrasound patch, we studied the clinical performance of 11 Ftc equations to detect a 10% change in SV measured by non-invasive pulse contour analysis; 26 healthy volunteers performed a standardized cardiac preload modifying maneuver. RESULTS: One hundred changes in cardiac preload and 3890 carotid beats were analyzed. Most of the 11 Ftc equations studied had similar diagnostic attributes. Wodeys' and Chambers' formulae had identical results; a 2% change in Ftc detected a 10% change in SV with a sensitivity and specificity of 96% and 93%, respectively. Similarly, a 3% change in Ftc calculated by Bazett's formula displayed a sensitivity and specificity of 91% and 93%. FtcWodey had 100% concordance and an R2 of 0.75 with change in SV; these values were 99%, 0.76 and 98%, 0.71 for FtcChambers and FtcBazetts, respectively. As an exploratory analysis, we studied 3335 carotid beats for the dispersion of Ftc during quiet breathing using the equations of Wodey and Bazett. The coefficient of variation of Ftc during quiet breathing for these formulae were 0.06 and 0.07, respectively. CONCLUSIONS: Most of the 11 different equations used to calculate carotid artery Ftc from a wearable Doppler ultrasound patch had similar thresholds and abilities to detect SV change in healthy volunteers. Variation in Ftc induced by the respiratory cycle is important; measuring a clinically significant change in Ftc with statistical confidence requires a large sample of beats.

6.
Crit Care Explor ; 2(1): e0072, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32166292

RESUMO

OBJECTIVES: Detecting instantaneous stroke volume change in response to altered cardiac preload is the physiologic foundation for determining preload responsiveness. DESIGN: Proof-of-concept physiology study. SETTING: Research simulation laboratory. SUBJECTS: Twelve healthy volunteers. INTERVENTIONS: A wireless continuous wave Doppler ultrasound patch was used to measure carotid velocity time integral and carotid corrected flow time during a squat maneuver. The Doppler patch measurements were compared with simultaneous stroke volume measurements obtained from a noninvasive cardiac output monitor. MEASUREMENTS AND MAIN RESULTS: From stand to squat, stroke volume increased by 24% while carotid velocity time integral and carotid corrected flow time increased by 32% and 9%, respectively. From squat to stand, stroke volume decreased by 13%, while carotid velocity time integral and carotid corrected flow time decreased by 24% and 10%, respectively. Both changes in carotid velocity time integral and corrected flow time were closely correlated with changes in stroke volume (r 2 = 0.81 and 0.62, respectively). The four-quadrant plot found a 100% concordance rate between changes in stroke volume and both changes in carotid velocity time integral and changes in corrected flow time. A change in carotid velocity time integral greater than 15% predicted a change in stroke volume greater than 10% with a sensitivity of 95% and a specificity of 92%. A change in carotid corrected flow time greater than 4% predicted a change in stroke volume greater than 10% with a sensitivity of 90% and a specificity of 92%. CONCLUSIONS: In healthy volunteers, both carotid velocity time integral and carotid corrected flow time measured by a wireless Doppler patch were useful to track changes in stroke volume induced by a preload-modifying maneuver with high sensitivity and specificity.