Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Med ; 80(1): 239-247, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29194732

RESUMO

PURPOSE: A prerequisite for cardiac MR (CMR) imaging is adequate synchronization of image acquisition with the cardiac cycle. Electrocardiogram triggering may be hampered by electromagnetic interferences at high field strength. The purpose of this work is to evaluate the feasibility of Doppler ultrasound triggering for CMR image synchronization at 7T ultra-high-field MRI. METHODS: A custom-built Doppler ultrasound (DUS) trigger device was developed. Magnetic resonance compatibility was evaluated using E- and H-field probes and flip angle maps prior to the study. Cardiac MR was performed at 7T in 13 healthy subjects using DUS and pulse oximetry for triggering. For validation of the trigger signal, the electrocardiogram, pulse, and DUS signals were compared outside of the MR room. Breath-hold cine fast low-angle-shot sequences were acquired in short-axis and four-chamber view. Image quality was assessed by two senior radiologists and by measurement of endocardial blurring. RESULTS: The maximal change in E- and H-field distributions with and without transducer was 5%. No interferences were observed between DUS and MRI in the B1 maps and during CMR imaging. Validation of the DUS trigger signal resulted in a high correlation to the electrocardiographic signal of r = 0.99. Analysis of image and trigger quality revealed no significant differences. CONCLUSION: Doppler ultrasound was applied as a new trigger method in CMR at 7T. The transmission line and transducer were locally approved as 7T MR conditional, and were successfully tested for image synchronization at 7T. In the future, this method needs to be evaluated in a larger patient population. Magn Reson Med 80:239-247, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ultrassonografia Doppler , Adulto , Artefatos , Eletrocardiografia , Radiação Eletromagnética , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Testes de Função Cardíaca , Humanos , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Masculino , Imagem Multimodal/métodos , Reprodutibilidade dos Testes , Adulto Jovem
2.
Cerebellum ; 15(3): 322-35, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26202670

RESUMO

The aim of the present study was to explore cerebellar contributions to the central executive in n-back working memory tasks using 7-T functional magnetic imaging (fMRI). We hypothesized that cerebellar activation increased with increasing working memory demands. Activations of the cerebellar cortex and dentate nuclei were compared between 0-back (serving as a motor control task), 1-back, and 2-back working memory tasks for both verbal and abstract modalities. A block design was used. Data of 27 participants (mean age 26.6 ± 3.8 years, female/male 12:15) were included in group statistical analysis. We observed that cerebellar cortical activations increased with higher central executive demands in n-back tasks independent of task modality. As confirmed by subtraction analyses, additional bilateral activations following higher executive demands were found primarily in four distinct cerebellar areas: (i) the border region of lobule VI and crus I, (ii) inferior parts of the lateral cerebellum (lobules crus II, VIIb, VIII, IX), (iii) posterior parts of the paravermal cerebellar cortex (lobules VI, crus I, crus II), and (iv) the inferior vermis (lobules VI, VIIb, VIII, IX). Dentate activations were observed for both verbal and abstract modalities. Task-related increases were less robust and detected for the verbal n-back tasks only. These results provide further evidence that the cerebellum participates in an amodal bilateral neuronal network representing the central executive during working memory n-back tasks.


Assuntos
Cerebelo/fisiologia , Memória de Curto Prazo/fisiologia , Adulto , Mapeamento Encefálico , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Testes Neuropsicológicos , Tempo de Reação , Percepção Visual/fisiologia
3.
Clin Radiol ; 69(4): 372-7, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24360512

RESUMO

AIM: To evaluate whether the addition of diffusion-weighted imaging (DWI) in bowel abdominal magnetic resonance imaging (MRI) can improve diagnostic confidence. MATERIALS AND METHODS: One hundred and eleven consecutive patients with suspected or known inflammatory bowel disease (n = 59), tumour disease (n = 31), unspecific abdominal pain (n = 16), and suspected graft-versus-host disease (n = 5) underwent bowel MRI using a 1.5 T MRI machine. In addition to T2-weighted (T2W) and contrast-enhanced T1-weighted (CE-T1W) data, axial and coronal DWI sequences were collected (b = 50, 500, 1000). Diagnostic confidence for lesion detection with and without DWI was evaluated using a four-point Likert scale [1 = certainly no lesion(s), 2 = probably no lesion(s), 3 = probably lesion(s), 4 = certainly lesion(s)]. RESULTS: In 11 of 111 patients (10%), the diagnostic confidence was improved by DWI. In seven patients, readers changed their diagnosis from "probable" to "certain presence of lesions". In another four patients, lesions were diagnosed based on DWI, which were not delineated on CE-T1W and T2W imaging. CONCLUSION: DWI of the bowel can provide additional information to the reader and, therefore, improve diagnostic confidence. Hence, additional DWI should be integrated into a standard bowel MRI protocol.


Assuntos
Dor Abdominal/patologia , Imagem de Difusão por Ressonância Magnética , Doença Enxerto-Hospedeiro/diagnóstico , Doenças Inflamatórias Intestinais/diagnóstico , Neoplasias Gástricas/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Meios de Contraste , Diagnóstico Diferencial , Feminino , Alemanha/epidemiologia , Doença Enxerto-Hospedeiro/epidemiologia , Doença Enxerto-Hospedeiro/patologia , Humanos , Doenças Inflamatórias Intestinais/epidemiologia , Doenças Inflamatórias Intestinais/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Neoplasias Gástricas/epidemiologia , Neoplasias Gástricas/patologia , Fatores de Tempo
4.
Mult Scler ; 19(1): 120-2, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22641302

RESUMO

Baló's concentric sclerosis (BCS) is an inflammatory demyelinating disease related to multiple sclerosis; its underlying pathology remains unclear. At 7 T MRI in a 19-year-old female BCS patient, microhaemorrhages and ectatic veins were found in T2 hyperintense regions, features which have not been previously reported in conjunction with BCS, and these findings may support the view that vascular pathology plays a role in BCS. MRS data suggest that neuron loss and lipid turnover still took place months after a remission. Plasma exchange was effective in treating a relapse with severe motor deficits, and the off-label use of natalizumab was successful in maintaining remission in this patient.


Assuntos
Esclerose Cerebral Difusa de Schilder/patologia , Imageamento por Ressonância Magnética/métodos , Anticorpos Monoclonais Humanizados/uso terapêutico , Encéfalo/patologia , Feminino , Humanos , Fatores Imunológicos/uso terapêutico , Natalizumab , Adulto Jovem
5.
Eur Radiol ; 23(4): 1059-66, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23064714

RESUMO

OBJECTIVE: The aim of this study was to assess the feasibility of first-pass contrast-enhanced renal MR angiography (MRA) at 7 T. METHODS: In vivo first-pass contrast-enhanced high-field examinations were obtained in eight healthy subjects on a 7-T whole-body MRI. A custom-built body transmit/receive radiofrequency (RF) coil and RF system suitable for RF shimming were used for image acquisition. For dynamic imaging, gadobutrol was injected intravenously and coronal unenhanced, arterial and venous data sets using a T1-weighted spoiled gradient-echo sequence were obtained. Qualitative image analysis and assessment of artefact impairment were performed by two senior radiologists using a five-point scale (5 = excellent, 1 = non-diagnostic). SNR and CNR of the perirenal abdominal aorta and both main renal arteries were assessed. RESULTS: Qualitative image evaluation revealed overall high-quality delineation of all assessed segments of the unenhanced arterial vasculature (meanunenhanced 4.13). Nevertheless, the application of contrast agent revealed an improvement in vessel delineation of all the vessel segments assessed, confirmed by qualitative (meanunenhanced 4.13 to meancontrast-enhanced 4.85) and quantitative analysis (SNR meanunenhanced 64.3 to meancontrast-enhanced 98.4). CONCLUSION: This study demonstrates the feasibility and current constraints of ultra-high-field contrast-enhanced renal MRA relative to unenhanced MRA.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Compostos Organometálicos , Artéria Renal/anatomia & histologia , Adulto , Meios de Contraste , Feminino , Humanos , Masculino , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Exp Brain Res ; 228(2): 243-54, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23732948

RESUMO

We investigated whether higher activation of the cerebellar cortex in unpredictable compared to predictable sequential finger movements reflects higher demands in motor response selection or also increases in demands on motor sequencing. Furthermore, we asked the question whether the cerebellar nuclei show a similar or reversed response profile as the cerebellar cortex. Ultra-high-field 7T functional magnetic resonance imaging was performed in nineteen right-handed, healthy young participants. Tasks involved finger tapping of a constant sequence, a random sequence, and with one finger at a time (no sequence). Conditions involved the same number of movements of fingers II-V. The three tasks were accompanied by the activation of the known hand areas within the cerebellar cortex and dentate nuclei. Activation of the cerebellar cortex and the dorsorostral dentate was significantly increased in the random-sequence condition compared to both the constant-sequence and the no-sequence conditions, with no significant difference between the constant-sequence and the no-sequence conditions. Error rate and movement frequency was not significantly different between conditions. Thus, differences between conditions cannot be explained by differences in motor execution. Because no difference was observed between the no-sequence and the constant-sequence conditions, increased cerebellar activation in the random-sequence condition likely reflects increased demands in motor response selection. Co-activation of cerebellar cortex and nuclei may be a consequence of excitatory afferent collaterals to the nuclei, "rebound-firing" of dentate neurons, and/or inhibitory synaptic input from Purkinje cells.


Assuntos
Córtex Cerebelar/fisiologia , Núcleos Cerebelares/fisiologia , Dedos/fisiologia , Imageamento por Ressonância Magnética , Movimento/fisiologia , Desempenho Psicomotor/fisiologia , Adulto , Mapeamento Encefálico/métodos , Cerebelo/fisiologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Estimulação Luminosa/métodos , Adulto Jovem
7.
Skeletal Radiol ; 42(2): 261-7, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22688975

RESUMO

OBJECTIVE: To present imaging characteristics of the ankle at 7.0 T and to investigate the appearance and image quality of presumed pathologies of ankles without physical strain as well as of ankles after a marathon run in comparison to 1.5 T. MATERIALS AND METHODS: Appearance of presumed pathologic findings and image quality of TSE (PD, T2, and STIR) and GRE sequences (MEDIC, DESS, and/or CISS) at 7.0 T and 1.5 T MRI were compared by two senior radiologists in consensus in two healthy controls without strain and in six marathon runners after a full-length marathon (eight males, mean age 49.1 years). RESULTS: Overall, 7.0 T MRI allowed for higher resolution images for most of the sequences while requiring comparable acquisition times and achieving high contrast images mainly in gradient echo sequences. Bursal or presumed peritendineal fluid and/or edematous tissue, which were found in seven of eight subjects, could be best appreciated with 7.0 T MEDIC. Other findings with sharper delineation at 7.0 T included cartilage defects (best: CISS), osseous avulsions, and osteophytes (best: DESS). Nevertheless, 1.5 T STIR imaging enabled assessment of a tibiotalar bone edema-like lesion in two runners, which was barely visible at 7.0 T using STIR, but not with any other sequence at 7.0 T including MEDIC (with frequency selective fat suppression). 7.0 T showed larger image quality variations with challenges especially in the TSE sequences. CONCLUSION: Our initial results of ultra-high-field ankle joint imaging demonstrate the improved depiction of ankle anatomy, fluid depositions, and cartilage defects. However imaging of edema-like bone lesions remains challenging at ultra-high magnetic field strength, and TSE coverage in particular is limited by the specific absorption rate.


Assuntos
Traumatismos do Tornozelo/patologia , Articulação do Tornozelo/patologia , Transtornos Traumáticos Cumulativos/patologia , Imageamento por Ressonância Magnética/métodos , Corrida/lesões , Adulto , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Neuroimage ; 62(3): 1537-50, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22634219

RESUMO

The first aim of the present study was to extend previous findings of similar cerebellar cortical areas being involved in verbal and spatial n-back working memory to the level of the cerebellar nuclei. The second aim was to investigate whether different areas of the cerebellar cortex and nuclei contribute to different working memory tasks (n-back vs. Sternberg tasks). Young and healthy subjects participated in two functional magnetic resonance imaging (fMRI) studies using a 7 T MR scanner with its increased signal-to-noise ratio. One group of subjects (n=21) performed an abstract and a verbal version of an n-back task contrasting a 2-back and 0-back condition. Another group of subjects (n=23) performed an abstract and a verbal version of a Sternberg task contrasting a high load and a low load condition. A block design was used. For image processing of the dentate nuclei, a recently developed region of interest (ROI) driven normalization method of the dentate nuclei was applied (Diedrichsen et al., 2011). Whereas activated areas of the cerebellar cortex and dentate nuclei were not significantly different comparing the abstract and verbal versions of the n-back task, activation in the abstract and verbal Sternberg tasks was significantly different. In both n-back tasks activation was most prominent at the border of lobules VI and Crus I, within lobule VII, and within the more caudal parts of the dentate nucleus bilaterally. In Sternberg tasks the most prominent activations were found in lobule VI extending into Crus I on the right. In the verbal Sternberg task activation was significantly larger within right lobule VI compared to the abstract Sternberg task and compared to the verbal n-back task. Activations of rostral parts of the dentate were most prominent in the verbal Sternberg task, whereas activation of caudal parts predominated in the abstract Sternberg task. On the one hand, the lack of difference between abstract and verbal n-back tasks and the lack of significant lateralization suggest a more general contribution of the cerebellum to working memory regardless of the modality. On the other hand, the focus of activation in right lobule VI in the verbal Sternberg task suggests specific cerebellar contributions to verbal working memory. The verbal Sternberg task emphasizes maintenance of stimuli via phonological rehearsal, whereas central executive demands prevail in n-back tasks. Based on the model of working memory by Baddeley and Hitch (1974), the present results show that different regions of the cerebellum support functions of the central executive system and one of the subsidiary systems, the phonological loop.


Assuntos
Mapeamento Encefálico/métodos , Córtex Cerebelar/fisiologia , Núcleos Cerebelares/fisiologia , Memória de Curto Prazo/fisiologia , Adulto , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa , Adulto Jovem
9.
Neuroimage ; 63(3): 1421-31, 2012 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-22892334

RESUMO

As yet, human cerebellar lesion studies have not taken advantage of direct magnetic resonance imaging (MRI) of the cerebellar nuclei in individual patients. In the present study, susceptibility weighted imaging (SWI) was used to visualize lesions of the dentate nuclei in patients with chronic focal lesions. Fifteen patients with cerebellar lesions either due to stroke or tumor surgery underwent SWI imaging using a 1.5T MRI scanner. Dentate nuclei were seen as hypointensities in all patients. Three of the patients underwent additional SWI imaging at 3T and 7T. Compared to 1.5T, corrugation of the dentate wall was seen with greater precision and the dorsal, iron-poorer part was seen more fully. Lesion-symptom mapping was performed based on the 1.5T MR images. Patients were divided into two groups with and without upper limb ataxia. A region-of-interest-(ROI)-driven normalization technique was used which had initially been developed by Diedrichsen et al. (2011) for functional MRI (fMRI) of the dentate nuclei. Compared to conventional normalization of the cerebellum, overlap of dentate lesions improved and lead to increased sensitivity of lesion-symptom maps. Subtraction analysis revealed that the more dorsal and rostral parts of the dentate nuclei were related to upper limb ataxia. Findings were in good accordance with the dentate hand area shown in recent fMRI studies. These data provide evidence that direct identification of dentate lesions together with the ROI-driven normalization technique allows for improved lesion-symptom mapping at the level of the cerebellar nuclei already at conventional 1.5T MRI field strength.


Assuntos
Lesões Encefálicas/patologia , Núcleos Cerebelares/patologia , Imageamento por Ressonância Magnética/métodos , Acidente Vascular Cerebral/patologia , Adolescente , Adulto , Idoso , Núcleos Cerebelares/lesões , Cerebelo/lesões , Cerebelo/patologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Adulto Jovem
10.
Magn Reson Med ; 67(4): 1033-41, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21858867

RESUMO

As the magnetic field strength and therefore the operational frequency in MRI are increased, the radiofrequency wavelength approaches the size of the human head/body, resulting in wave effects which cause signal decreases and dropouts. Especially, whole-body imaging at 7 T and higher is therefore challenging. Recently, an acquisition scheme called time-interleaved acquisition of modes has been proposed to tackle the inhomogeneity problems in high-field MRI. The basic premise is to excite two (or more) different B 1+ modes using static radiofrequency shimming in an interleaved acquisition, where the complementary radiofrequency patterns of the two modes can be exploited to improve overall signal homogeneity. In this work, the impact of time-interleaved acquisition of mode on image contrast as well as on time-averaged specific absorption rate is addressed in detail. Time-interleaved acquisition of mode is superior in B 1+ homogeneity compared with conventional radiofrequency shimming while being highly specific absorption rate efficient. Time-interleaved acquisition of modes can enable almost homogeneous high-field imaging throughout the entire field of view in PD, T(2) , and T(2) *-weighted imaging and, if a specified homogeneity criterion is met, in T(1) -weighted imaging as well.


Assuntos
Imageamento por Ressonância Magnética/métodos , Algoritmos , Artefatos , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Análise dos Mínimos Quadrados , Masculino , Modelos Anatômicos , Imagens de Fantasmas , Ondas de Rádio , Sensibilidade e Especificidade , Fatores de Tempo
11.
J Magn Reson Imaging ; 36(3): 714-21, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22649028

RESUMO

PURPOSE: To investigate the feasibility of 7 Tesla (T) nonenhanced high field MR imaging of the renal vasculature and to evaluate the diagnostic potential of various nonenhanced T1-weighted (T1w) sequences. MATERIALS AND METHODS: Twelve healthy volunteers were examined on a 7T whole-body MR system (Magnetom 7T, Siemens Healthcare Sector) using a custom-built eight-channel radiofrequency (RF) transmit/receive body coil. Subsequent to RF shimming, the following sequences were acquired (i) fat-saturated two-dimensional (2D) FLASH, (ii) fat-saturated 3D FLASH, and a (iii) fat-saturated 2D time-of-flight MR angiography (TOF MRA). SNR and CNR were measured in the aorta and both renal arteries. Qualitative analysis was performed with regard to vessel delineation (5-point scale: 5 = excellent to 1 = nondiagnostic) and presence of artifacts (5-point scale: 5 = no artifact present to 1 = strong impairment). RESULTS: The inherently high signal intensity of the renal arterial vasculature in T1w imaging enabled moderate to excellent vessel delineation in all sequences. Qualitative (mean, 4.7) and quantitative analysis (SNR(mean) : 53.9; CNR(mean) : 28.0) demonstrated the superiority of TOF MRA, whereas 2D FLASH imaging provided poorest vessel delineation and was most strongly impaired by artifacts (overall impairment 3.7). The 3D FLASH MRI demonstrated its potential for fast high quality imaging of the nonenhanced arterial vasculature, providing homogeneous hyperintense vessel signal. CONCLUSION: Nonenhanced T1w imaging in general and, TOF MRA in particular, appear to be promising techniques for good quality nonenhanced renal artery assessment at 7 Tesla.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Artéria Renal/anatomia & histologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Neuroimage ; 54(3): 1786-94, 2011 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-20965257

RESUMO

The deep cerebellar nuclei (DCN) are a key element of the cortico-cerebellar loop. Because of their small size and functional diversity, it is difficult to study them using magnetic resonance imaging (MRI). To overcome these difficulties, we present here three related methodological advances. First, we used susceptibility-weighted imaging (SWI) at a high-field strength (7T) to identify the dentate, globose, emboliform and fastigial nucleus in 23 human participants. Due to their high iron content, the DCN are visible as hypo-intensities. Secondly, we generated probabilistic maps of the deep cerebellar nuclei in MNI space using a number of common normalization techniques. These maps can serve as a guide to the average location of the DCN, and are integrated into an existing probabilistic atlas of the human cerebellum (Diedrichsen et al., 2009). The maps also quantify the variability of the anatomical location of the deep cerebellar nuclei after normalization. Our results indicate that existing normalization techniques do not provide satisfactory overlap to analyze the functional specialization within the DCN. We therefore thirdly propose a ROI-driven normalization technique that utilizes both information from a T1-weighted image and the hypo-intensity from a T2*-weighted or SWI image to ensure overlap of the nuclei. These techniques will promote the study of the functional specialization of subregions of the DCN using MRI.


Assuntos
Núcleos Cerebelares/anatomia & histologia , Adulto , Envelhecimento/fisiologia , Algoritmos , Artefatos , Atlas como Assunto , Mapeamento Encefálico/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Individualidade , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Modelos Neurológicos , Modelos Estatísticos , Variações Dependentes do Observador , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
13.
Neuroimage ; 57(3): 1184-91, 2011 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-21640191

RESUMO

There is increasing evidence of a topographic organization within the human cerebellar cortex for motor and non-motor functions. Likewise, a subdivision of the dentate nucleus in a more dorsal and rostral motor domain and a more ventral and caudal non-motor domain has been proposed by Dum and Strick (2003) based on anatomical studies in monkey. In humans, however, very little is known about topographic organization within the dentate nucleus. Activation of the dentate nucleus in a verb generation task was examined in young and healthy subjects using ultra-highfield 7T functional magnetic resonance imaging (fMRI) with its increase in signal-to-noise ratio. Data of 17 subjects were included in statistical analysis. Subjects were asked to (i) read words (nouns) aloud presented on a screen, (ii) silently read the same nouns, (iii) silently generate the appropriate verbs to the same nouns and (iv) to silently repeat the names of the months. A block design was used. For image processing, a recently developed region of interest (ROI) driven normalization method of the dentate nuclei was applied. Activation related to motor speech (contrast aloud reading minus silent reading) was strongest in the rostral parts of the dentate nucleus. Dorsorostral activations were present bilaterally. Activation related to verb generation (contrast verb generation minus silent reading) was found in the ventrocaudal parts of the dentate nucleus on the right. The present findings are in good accordance with the anatomical data in monkeys and suggest that the human dentate nucleus can be subdivided into a rostral and more dorsal motor domain and a ventrocaudal non-motor domain.


Assuntos
Mapeamento Encefálico , Encéfalo/fisiologia , Núcleos Cerebelares/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Fala/fisiologia , Adulto , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Adulto Jovem
14.
Neuroimage ; 54(4): 2612-22, 2011 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-21081171

RESUMO

Dum and Strick (J. Neurophysiol. 2003; 89, 634-639) proposed a division of the cerebellar dentate nucleus into a "motor" and "non-motor" area based on anatomical data in the monkey. We asked the question whether motor and non-motor domains of the dentate can be found in humans using functional magnetic resonance imaging (fMRI). Therefore dentate activation was compared in motor and cognitive tasks. Young, healthy participants were tested in a 1.5 T MRI scanner. Data from 13 participants were included in the final analysis. A block design was used for the experimental conditions. Finger tapping of different complexities served as motor tasks, while cognitive testing included a verbal working memory and a visuospatial task. To further confirm motor-related dentate activation, a simple finger movement task was tested in a supplementary experiment using ultra-highfield (7 T) fMRI in 23 participants. For image processing, a recently developed region of interest (ROI) driven normalization method of the deep cerebellar nuclei was used. Dorso-rostral dentate nucleus activation was associated with motor function, whereas cognitive tasks led to prominent activation of the caudal nucleus. The visuospatial task evoked activity bilaterally in the caudal dentate nucleus, whereas verbal working memory led to activation predominantly in the right caudal dentate. These findings are consistent with Dum and Strick's anatomical findings in the monkey.


Assuntos
Mapeamento Encefálico , Núcleos Cerebelares/anatomia & histologia , Núcleos Cerebelares/fisiologia , Cognição/fisiologia , Movimento/fisiologia , Adulto , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino
15.
Hippocampus ; 19(1): 1-7, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18727048

RESUMO

The human hippocampus plays a central role in various neuropsychiatric disorders, such as temporal lobe epilepsy (TLE), Alzheimer's dementia, mild cognitive impairment, and schizophrenia. Its volume, morphology, inner structure, and function are of scientific and clinical interest. Magnetic resonance (MR) imaging is a widely employed tool in neuroradiological workup regarding changes in brain anatomy, (sub-) volumes, and cerebral function including the hippocampus. Gain in intrinsic MR signal provided by higher field strength scanners and concomitant improvements in spatial resolution seem highly valuable. An examination protocol permitting complete, high-resolution imaging of the human hippocampus at 7 T was implemented. Coronal proton density, T2, T2*, and fluid-attenuated inversion recovery contrasts were acquired as well as an isotropic 3D magnetization-prepared rapid acquisition gradient-echo (500 microm isotropic voxel dimension, noninterpolated). Observance of energy deposition restrictions within acceptable scan times remained challenging in the acquisition of thin, spin-echo-based sections. At the higher resolution enabled by 7 T, demarcation of the hippocampus and some internal features including gray/white matter differentiation and depiction of the hippocampal mantle becomes much more viable when compared with 1.5 T; thus, in the future, this imaging technology might help in the diagnosis of subtle hippocampal changes.


Assuntos
Hipocampo/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Doença de Alzheimer/patologia , Doença de Alzheimer/fisiopatologia , Atrofia/patologia , Atrofia/fisiopatologia , Demência/patologia , Demência/fisiopatologia , Epilepsia do Lobo Temporal/patologia , Epilepsia do Lobo Temporal/fisiopatologia , Hipocampo/fisiologia , Humanos , Fibras Nervosas Mielinizadas/fisiologia , Fibras Nervosas Mielinizadas/ultraestrutura , Valor Preditivo dos Testes
16.
AJNR Am J Neuroradiol ; 40(7): 1106-1111, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31147351

RESUMO

BACKGROUND AND PURPOSE: The pathophysiology of wall contrast enhancement in thrombosed intracranial aneurysms is incompletely understood. This in vivo study aimed to investigate wall microstructures with gadolinium-enhanced 7T MR imaging. MATERIALS AND METHODS: Thirteen patients with 14 thrombosed intracranial aneurysms were evaluated using a 7T whole-body MR imaging system with nonenhanced and gadolinium-enhanced high-resolution MPRAGE. Tissue samples were available in 5 cases, and histopathologic findings were correlated with 7T MR imaging to identify the gadolinium-enhancing microstructures. RESULTS: Partial or complete inner wall enhancement correlated with neovascularization of the inner wall layer and the adjacent thrombus. Additional partial or complete outer wall enhancement can be explained by formation of vasa vasorum in the outer aneurysm wall layer. The double-rim enhancement correlated with perifocal edema and wall histologic findings suggestive of instability. CONCLUSIONS: Two distinct aneurysm wall microstructures responsible for gadolinium enhancement not depictable at lower spatial resolutions can be visualized in vivo using high-resolution gadolinium-enhanced 7T MR imaging.


Assuntos
Aneurisma Intracraniano/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Trombose/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Gadolínio , Humanos , Interpretação de Imagem Assistida por Computador , Aneurisma Intracraniano/patologia , Masculino , Pessoa de Meia-Idade , Trombose/patologia
17.
Eur J Radiol ; 66(2): 300-8, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-17658235

RESUMO

PURPOSE: 2- and 3-dimensional evaluation of quantitative pharmacokinetic parameters derived from the Tofts model modeling dynamic contrast enhancement of lesions in MR mammography. MATERIALS AND METHODS: In 95 patients, MR mammography revealed 127 suspicious lesions. The initial rate of enhancement was coded by color intensity, the post-initial enhancement change is coded by color hue. 2D and 3D analysis of distribution of color hue and intensity, vascular permeability and extracellular volume were performed. RESULTS: In 2D, malignant lesions showed significant higher number of bright red, medium red, dark red, bright green, medium green, dark green and bright blue pixels than benign lesions. In 3D, statistical significant differences between malignant and benign lesions was found for all this parameters. Vascular permeability was significant higher in malignant lesions than in benign lesions. Regression model using the 3D data found that the best discriminator between malignant and benign lesions was combined number of voxels and medium green pixels, with a sensitivity of 79.4% and a specificity of 83.1%. CONCLUSIONS: Quantitative analysis of pharmacokinetic variables of contrast kinetics showed significant differences between malignant and benign lesions. 3D analysis showed superior diagnostic differentiation between malignant and benign lesions than 2D analysis. The parametric analysis using a pharmacokinetic model allows objective analysis of contrast enhancement in breast lesions.


Assuntos
Doenças Mamárias/diagnóstico , Meios de Contraste/farmacocinética , Gadolínio DTPA/farmacocinética , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Distribuição de Qui-Quadrado , Diagnóstico Diferencial , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Modelos Logísticos , Pessoa de Meia-Idade , Curva ROC , Análise de Regressão
18.
Nuklearmedizin ; 47(2): 73-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18392316

RESUMO

UNLABELLED: We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. PATIENTS, METHODS: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution FDG-PET images was graded for confidence: 1: none, 2: suggestive, 3: clear. Mean tumour activity was calculated for summed image frames that resulted in confidence grades 2 and 3. Whole-body FDG-PET/CT images were reviewed for lesions. PET-MRI and PET/CT-MRI images of the head were co-registered for potentially improved lesion delineation. RESULTS: Whole-body FDG-PET/CT images of 3/3 patients were positive for uveal melanomas and negative for disseminated disease. HR FDG-PET was positive already in the early time frames. One patient exhibited rising tumour activity with increasing uptake time on FDG-PET. MRI images of the eye were co-registered successfully to FDG-PET/CT using a manual alignment approach. CONCLUSIONS: Small-size uveal melanomas can be detected with whole-body FDG-PET/CT. This feasibility study suggests the exploration of HR FDG-PET in order to provide additional diagnostic information on patients with uveal melanomas. First results support extended uptake times and high-sensitivity PET for improved tumour visibility. MRI/PET co-registration is feasible and provides correlated functional and anatomical information that may support alternative therapy regimens.


Assuntos
Neoplasias Uveais/diagnóstico por imagem , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética/métodos , Melanoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Radiografia , Radioisótopos , Sensibilidade e Especificidade , Neoplasias Uveais/diagnóstico , Irradiação Corporal Total
19.
Rofo ; 179(12): 1231-5, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18004692

RESUMO

PURPOSE: Measurement protocols which have been optimized for MRI at field strengths of 1.5 T or 3 T cannot be directly transferred to 7 T. Specific absorption rate limitations, different tissue relaxation times, as well as new image artifacts require adjustments of the sequence parameters. The goal of our study was to investigate and optimize various sequences for 7 T imaging of the knee. MATERIALS AND METHODS: Starting with sequences used on a standard 1.5 T scanner, the parameters were modified to obtain optimal image contrast, maximum coverage, and the highest spatial resolution within a reasonable acquisition time. All sequences were optimized in two healthy volunteers and then tested in 10 patients with various pathologies. High-resolution 7 T images with several SE and GRE sequences were acquired and compared to 1.5 T images. RESULTS: A comparison of 1.5 T and 7 T images clearly shows the advantage of MRI at higher field strengths, especially the higher SNR which could be translated into higher spatial resolution. The MEDIC sequence appears to be very well suited for the assessment of cartilage pathologies at 7 T. Using the DESS sequence, full coverage of the knee can be obtained with a very high resolution of 0.4 x 0.4 x 1.0 mm(3) within 7 minutes. Despite optimization of the STIR sequence parameters, bone marrow edema is better visualized at 1.5 T compared to 7 T. The PD TSE renders excellent image quality at 7 T. The total acquisition time of the 7 T protocol is approximately 40 minutes. CONCLUSION: Gradient echo sequences provide excellent image contrast at very high spatial resolution in a reasonable scan time. However, not all sequences used at 1.5 T are currently well suited for high-field imaging, in particular SAR-intensive sequences. Imaging of meniscal tears and lesions of the cruciate ligaments may benefit from the higher spatial resolution. The most favorable clinical indication for knee examinations at 7 T currently appears to be cartilage imaging.


Assuntos
Doenças das Cartilagens/diagnóstico , Cartilagem Articular/patologia , Traumatismos do Joelho/diagnóstico , Articulação do Joelho/anatomia & histologia , Articulação do Joelho/patologia , Ligamentos Articulares/patologia , Imageamento por Ressonância Magnética/métodos , Meniscos Tibiais/patologia , Adulto , Osso e Ossos/lesões , Feminino , Humanos , Consentimento Livre e Esclarecido , Ligamentos Articulares/lesões , Masculino , Lesões do Menisco Tibial , Fatores de Tempo
20.
Rofo ; 176(2): 163-9, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14872368

RESUMO

PURPOSE: To combine whole-body multi-station three-dimensional contrast enhanced magnetic resonance angiography (3D CE MRA) using a self-developed rolling table platform with parallel imaging strategies (PAT) in order to increase the spatial resolution of the 3D MRA data sets. MATERIALS AND METHODS: Whole-body multi-station MRA was performed with a rolling table platform (AngioSURF) on 5 volunteers in two imaging series: 1) standard imaging protocol, 2) modified high-resolution protocol employing PAT using the generalized autocalibrating partially parallel acquisitions (GRAPPA) algorithm with an acceleration factor of 3. For an intra-individual comparison of the two MR examinations, the arterial vasculature was divided into 30 segments. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated for all 30 arterial segments of each subject. Vessel segment depiction was qualitatively assessed applying a 5-point scale to each of the segments. Image reconstruction times were recorded for the standard as well as the PAT protocol. RESULTS: Compared to the standard protocol, PAT allowed for increased spatial resolution through a 3-fold reduction in mean voxel size for each of the 5 stations. Mean SNR and CNR values over all specified vessel segments decreased by a factor of 1.58 and 1.56, respectively. Despite the reduced SNR and CNR, the depiction of all specified vessel segments increased in PAT images, reflecting the increased spatial resolution. Qualitative comparison of standard and PAT images showed an increase in vessel segment conspicuity with more detailed depiction of intramuscular arterial branches in all volunteers. The time for image data reconstruction of all 5 stations was significantly increased from about 10 minutes to 40 minutes when using the PAT acquisition. CONCLUSION: The implementation of PAT into the concept of whole-body MRA enabled to increase the spatial resolution in all examined territories, which resulted in more detailed MR angiograms.


Assuntos
Vasos Sanguíneos/anatomia & histologia , Angiografia por Ressonância Magnética/métodos , Adulto , Algoritmos , Meios de Contraste , Interpretação Estatística de Dados , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Angiografia por Ressonância Magnética/instrumentação , Masculino , Músculos/irrigação sanguínea , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA