Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Radiology ; 307(3): e222389, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36853176

RESUMO

Background In Crohn disease, differentiation between active intestinal inflammation and fibrosis has implications for treatment, but current imaging modalities are not reliably accurate. Purpose To evaluate the predictive value of gallium 68 (68Ga)-labeled fibroblast activation protein inhibitor (FAPI) PET/MR enterography for the assessment of bowel wall fibrosis in Crohn disease. Materials and Methods In this prospective single-center study, consecutive participants with Crohn disease and obstructive symptoms underwent preoperative 68Ga-FAPI PET/MR enterography from May 2021 to January 2022. Histopathologic analysis of resected bowel segments was performed to grade active inflammation (A0-A2) and fibrosis (F0-F2), which served as the reference standard. The fibroblast activation protein (FAP) expression in bowel wall layers was analyzed immunohistochemically for each layer. 68Ga-FAPI-derived maximum standardized uptake value (SUVmax) was compared with histopathologic results by using mixed-model analysis of variance and Bonferroni-corrected post hoc tests. Results In 14 participants (mean age, 45 years ± 9 [SD]; 10 men), fibrosis was diagnosed histopathologically in 28 of 51 bowel segments (grade F1, n = 14; grade F2, n = 14). Mean SUVmax was higher in segments with fibrosis than without (7.6 vs 2.0; P < .001). In severe fibrosis, mean SUVmax was higher than in mild to moderate fibrosis (8.9 ± 0.9 vs 6.2 ± 0.9; P = .045). Bowel segments with isolated active inflammation had lower mean 68Ga-FAPI uptake than segments with combined active inflammation and fibrosis (SUVmax, 3.2 ± 0.4 vs 8.1 ± 0.1; P = .005). With an SUVmax cutoff value of 3.5, the area under the receiver operating characteristic curve for the prediction of fibrosis was 0.94 (95% CI: 0.9, 1.0), with sensitivity of 26 of 28 segments (93%) and specificity of five of six segments (83%). 68Ga-FAPI-derived SUVmax correlated with FAP expression across all bowel layers (R2 = 0.50, P < .001). Conclusion Higher gallium 68 fibroblast activation protein inhibitor uptake at PET/MR enterography was associated with histopathologically assessed bowel wall fibrosis in participants with Crohn disease, suggesting diagnostic potential for treatment decisions. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by O'Shea in this issue.


Assuntos
Doença de Crohn , Fibrose , Fibrose/diagnóstico por imagem , Doença de Crohn/patologia , Radioisótopos de Gálio , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons , Inflamação , Obstrução Intestinal/diagnóstico por imagem , Estudos Prospectivos , Compostos Radiofarmacêuticos , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso
2.
Eur Radiol ; 31(5): 2967-2982, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33104846

RESUMO

MAIN RECOMMENDATIONS: 1. ESGE/ESGAR recommend computed tomographic colonography (CTC) as the radiological examination of choice for the diagnosis of colorectal neoplasia. Strong recommendation, high quality evidence. ESGE/ESGAR do not recommend barium enema in this setting. Strong recommendation, high quality evidence.2. ESGE/ESGAR recommend CTC, preferably the same or next day, if colonoscopy is incomplete. The timing depends on an interdisciplinary decision including endoscopic and radiological factors. Strong recommendation, low quality evidence. ESGE/ESGAR suggests that, in centers with expertise in and availability of colon capsule endoscopy (CCE), CCE preferably the same or the next day may be considered if colonoscopy is incomplete. Weak recommendation, low quality evidence.3. When colonoscopy is contraindicated or not possible, ESGE/ESGAR recommend CTC as an acceptable and equally sensitive alternative for patients with alarm symptoms. Strong recommendation, high quality evidence. Because of lack of direct evidence, ESGE/ESGAR do not recommend CCE in this situation. Very low quality evidence. ESGE/ESGAR recommend CTC as an acceptable alternative to colonoscopy for patients with non-alarm symptoms. Strong recommendation, high quality evidence. In centers with availability, ESGE/ESGAR suggests that CCE may be considered in patients with non-alarm symptoms. Weak recommendation, low quality evidence.4. Where there is no organized fecal immunochemical test (FIT)-based population colorectal screening program, ESGE/ESGAR recommend CTC as an option for colorectal cancer screening, providing the screenee is adequately informed about test characteristics, benefits, and risks, and depending on local service- and patient-related factors. Strong recommendation, high quality evidence. ESGE/ESGAR do not suggest CCE as a first-line screening test for colorectal cancer. Weak recommendation, low quality evidence.5. ESGE/ESGAR recommend CTC in the case of a positive fecal occult blood test (FOBT) or FIT with incomplete or unfeasible colonoscopy, within organized population screening programs. Strong recommendation, moderate quality evidence. ESGE/ESGAR also suggest the use of CCE in this setting based on availability. Weak recommendation, moderate quality evidence.6. ESGE/ESGAR suggest CTC with intravenous contrast medium injection for surveillance after curative-intent resection of colorectal cancer only in patients in whom colonoscopy is contraindicated or unfeasible. Weak recommendation, low quality evidence. There is insufficient evidence to recommend CCE in this setting. Very low quality evidence.7. ESGE/ESGAR suggest CTC in patients with high risk polyps undergoing surveillance after polypectomy only when colonoscopy is unfeasible. Weak recommendation, low quality evidence. There is insufficient evidence to recommend CCE in post-polypectomy surveillance. Very low quality evidence.8. ESGE/ESGAR recommend against CTC in patients with acute colonic inflammation and in those who have recently undergone colorectal surgery, pending a multidisciplinary evaluation. Strong recommendation, low quality evidence.9. ESGE/ESGAR recommend referral for endoscopic polypectomy in patients with at least one polyp ≥6 mm detected at CTC or CCE. Follow-up CTC may be clinically considered for 6-9-mm CTC-detected lesions if patients do not undergo polypectomy because of patient choice, comorbidity, and/or low risk profile for advanced neoplasia. Strong recommendation, moderate quality evidence. Source and scope This is an update of the 2014-15 Guideline of the European Society of Gastrointestinal Endoscopy (ESGE) and the European Society of Gastrointestinal and Abdominal Radiology (ESGAR). It addresses the clinical indications for the use of imaging alternatives to standard colonoscopy. A targeted literature search was performed to evaluate the evidence supporting the use of computed tomographic colonography (CTC) or colon capsule endoscopy (CCE). The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was adopted to define the strength of recommendations and the quality of evidence.


Assuntos
Colonografia Tomográfica Computadorizada , Neoplasias Colorretais , Radiologia , Colonoscopia , Neoplasias Colorretais/diagnóstico por imagem , Endoscopia Gastrointestinal , Humanos
3.
Proc Natl Acad Sci U S A ; 115(37): 9270-9275, 2018 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-30158167

RESUMO

One of the best-known general patterns in island biogeography is the species-isolation relationship (SIR), a decrease in the number of native species with increasing island isolation that is linked to lower rates of natural dispersal and colonization on remote oceanic islands. However, during recent centuries, the anthropogenic introduction of alien species has increasingly gained importance and altered the composition and richness of island species pools. We analyzed a large dataset for alien and native plants, ants, reptiles, mammals, and birds on 257 (sub) tropical islands, and showed that, except for birds, the number of naturalized alien species increases with isolation for all taxa, a pattern that is opposite to the negative SIR of native species. We argue that the reversal of the SIR for alien species is driven by an increase in island invasibility due to reduced diversity and increased ecological naiveté of native biota on the more remote islands.


Assuntos
Espécies Introduzidas , Ilhas , Modelos Biológicos , Clima Tropical
4.
Endoscopy ; 52(12): 1127-1141, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33105507

RESUMO

1: ESGE/ESGAR recommend computed tomographic colonography (CTC) as the radiological examination of choice for the diagnosis of colorectal neoplasia.Strong recommendation, high quality evidence.ESGE/ESGAR do not recommend barium enema in this setting.Strong recommendation, high quality evidence. 2: ESGE/ESGAR recommend CTC, preferably the same or next day, if colonoscopy is incomplete. The timing depends on an interdisciplinary decision including endoscopic and radiological factors.Strong recommendation, low quality evidence.ESGE/ESGAR suggests that, in centers with expertise in and availability of colon capsule endoscopy (CCE), CCE preferably the same or the next day may be considered if colonoscopy is incomplete.Weak recommendation, low quality evidence. 3: When colonoscopy is contraindicated or not possible, ESGE/ESGAR recommend CTC as an acceptable and equally sensitive alternative for patients with alarm symptoms.Strong recommendation, high quality evidence.Because of lack of direct evidence, ESGE/ESGAR do not recommend CCE in this situation.Very low quality evidence.ESGE/ESGAR recommend CTC as an acceptable alternative to colonoscopy for patients with non-alarm symptoms.Strong recommendation, high quality evidence.In centers with availability, ESGE/ESGAR suggests that CCE may be considered in patients with non-alarm symptoms.Weak recommendation, low quality evidence. 4: Where there is no organized fecal immunochemical test (FIT)-based population colorectal screening program, ESGE/ESGAR recommend CTC as an option for colorectal cancer screening, providing the screenee is adequately informed about test characteristics, benefits, and risks, and depending on local service- and patient-related factors.Strong recommendation, high quality evidence.ESGE/ESGAR do not suggest CCE as a first-line screening test for colorectal cancer.Weak recommendation, low quality evidence. 5: ESGE/ESGAR recommend CTC in the case of a positive fecal occult blood test (FOBT) or FIT with incomplete or unfeasible colonoscopy, within organized population screening programs.Strong recommendation, moderate quality evidence.ESGE/ESGAR also suggest the use of CCE in this setting based on availability.Weak recommendation, moderate quality evidence. 6: ESGE/ESGAR suggest CTC with intravenous contrast medium injection for surveillance after curative-intent resection of colorectal cancer only in patients in whom colonoscopy is contraindicated or unfeasibleWeak recommendation, low quality evidence.There is insufficient evidence to recommend CCE in this setting.Very low quality evidence. 7: ESGE/ESGAR suggest CTC in patients with high risk polyps undergoing surveillance after polypectomy only when colonoscopy is unfeasible.Weak recommendation, low quality evidence.There is insufficient evidence to recommend CCE in post-polypectomy surveillance.Very low quality evidence. 8: ESGE/ESGAR recommend against CTC in patients with acute colonic inflammation and in those who have recently undergone colorectal surgery, pending a multidisciplinary evaluation.Strong recommendation, low quality evidence. 9: ESGE/ESGAR recommend referral for endoscopic polypectomy in patients with at least one polyp ≥ 6 mm detected at CTC or CCE.Follow-up CTC may be clinically considered for 6 - 9-mm CTC-detected lesions if patients do not undergo polypectomy because of patient choice, comorbidity, and/or low risk profile for advanced neoplasia.Strong recommendation, moderate quality evidence.


Assuntos
Colonografia Tomográfica Computadorizada , Neoplasias Colorretais , Radiologia , Colonoscopia , Neoplasias Colorretais/diagnóstico por imagem , Humanos
5.
Eur Radiol ; 30(10): 5358-5366, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32458171

RESUMO

OBJECTIVES: Enteric and colonic sinus tracts are inflammatory complications that precede intestinal fistulas in patients with Crohn's disease (CD). The aim of this study was to retrospectively determine the prevalence, morphologic features, and outcome of sinus tracts using MR imaging. METHODS: A consecutive cohort of 642 patients with known CD, referred for MR enterography or MR enteroclysis (study period 01/2014-09/2019), was evaluated retrospectively for the presence of sinus tracts, their locations, presence and length of coexisting strictures, bowel wall thickness, CDMI score, upstream dilation, and bowel distension. Clinical outcome was assessed using medical records. For metric data, means and standard deviation, as well as one-way ANOVA and Pearson's correlation coefficient, were calculated. RESULTS: In 36/642 patients with CD undergoing MRE, 49 sinus tracts (forty in small intestine, nine in left-sided colon) were detected with a prevalence of 6.9% in patients with MR-visible signs of CD (n = 519, overall prevalence of 5.6%). Mean segmental bowel wall thickness was 8.9 mm, and mean CDMI score was 9.3. All sinus tracts were located within a stenotic segment, showing mesenteric orientation within the small bowel and upstream dilation in 13 patients. Of 36 patients, 19 underwent immediate surgery and seven developed clinical progression within the segment containing the sinus tract. CONCLUSIONS: Sinus tracts occur in 6.9% of patients with visible signs of CD. They are located within stenotic, severely thickened bowel segments with high MR inflammation scores. Their detection is clinically important, because they indicate a more aggressive phenotype and, if left untreated, may show severe progression. KEY POINTS: • Sinus tracts occur in 6.9% of patients with MR-visible signs of Crohn's disease. • Sinus tracts are a radiological indicator of early penetrating Crohn's disease, with a high risk of progression, and require dedicated treatment. • Sinus tracts can be recognized by characteristic findings and typically occur in stenotic, severely thickened bowel segments with high MR inflammation scores.


Assuntos
Colo/diagnóstico por imagem , Colo/patologia , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Adolescente , Adulto , Constrição Patológica/etiologia , Doença de Crohn/complicações , Dilatação Patológica/etiologia , Progressão da Doença , Feminino , Humanos , Fístula Intestinal/etiologia , Obstrução Intestinal/etiologia , Imageamento por Ressonância Magnética , Masculino , Prevalência , Estudos Retrospectivos , Adulto Jovem
6.
Biofouling ; 35(7): 742-757, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31550929

RESUMO

The self-produced extracellular polymeric matrix of biofilms renders them difficult to eliminate once they are established. This makes the inhibition of biofilm formation key to successful treatment of biofilm infection. Antimicrobial photodynamic therapy (aPDT) and antimicrobial peptides offer a new approach as antibiofilm strategies. In this study sub-lethal doses of aPDT (with chlorin-e6 (Ce6-PDT) or methylene blue (MB-PDT)) and the peptides AU (aurein 1.2 monomer) or (AU)2K (aurein 1.2 C-terminal dimer) were combined to evaluate their ability to prevent biofilm development by Enterococcus faecalis. Biofilm formation was assessed by resazurin reduction, confocal microscopy, and infrared spectroscopy. All treatments successfully prevented biofilm development. The (AU)2K dimer had a stronger effect, both alone and combined with aPDT, while the monomer AU had significant activity when combined with Ce6-PDT. Additionally, it is shown that the peptides bind to the lipoteichoic acid of the E. faecalis cell wall, pointing to a possible key mechanism of biofilm inhibition.


Assuntos
Antibacterianos/química , Biofilmes , Peptídeos/química , Fármacos Fotossensibilizantes/química , Antibacterianos/farmacologia , Biofilmes/efeitos dos fármacos , Clorofilídeos , Enterococcus faecalis/efeitos dos fármacos , Enterococcus faecalis/fisiologia , Peptídeos/farmacologia , Fotoquimioterapia , Fármacos Fotossensibilizantes/farmacologia , Porfirinas/química
7.
Knee Surg Sports Traumatol Arthrosc ; 27(5): 1552-1561, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-29881885

RESUMO

PURPOSE: To evaluate the influence of different scan parameters for single-energy CT and dual-energy CT, as well as the impact of different material used in a TKA prosthesis on image quality and the extent of metal artifacts. METHODS: Eight pairs of TKA prostheses from different vendors were examined in a phantom set-up. Each pair consisted of a conventional CoCr prosthesis and the corresponding anti-allergic prosthesis (full titanium, ceramic, or ceramic-coated) from the same vendor. Nine different (seven dual-energy CT and two single-energy CT) scan protocols with different characteristics were used to determine the most suitable CT protocol for TKA imaging. Quantitative image analysis included assessment of blooming artifacts (metal implants appear thicker on CT than they are, given as virtual growth in mm in this paper) and streak artifacts (thick dark lines around metal). Qualitative image analysis was used to investigate the bone-prosthesis interface. RESULTS: The full titanium prosthesis and full ceramic knee showed significantly fewer blooming artifacts compared to the standard CoCr prosthesis (mean virtual growth 0.6-2.2 mm compared to 2.9-4.6 mm, p < 0.001). Dual-energy CT protocols showed less blooming (range 3.3-3.8 mm) compared to single-energy protocols (4.6-5.5 mm). The full titanium and full ceramic prostheses showed significantly fewer streak artifacts (mean standard deviation 77-86 Hounsfield unit (HU)) compared to the standard CoCr prosthesis (277-334 HU, p < 0.001). All dual-energy CT protocols had fewer metal streak artifacts (215-296 HU compared to single-energy CT protocols (392-497 HU)). Full titanium and ceramic prostheses were ranked superior with regard to the image quality at the bone/prosthesis interface compared to a standard CoCr prosthesis, and all dual-energy CT protocols were ranked better than single-energy protocols. CONCLUSIONS: Dual-energy CT and ceramic or titanium prostheses reduce CT artifacts and provide superior image quality of total knee arthroplasty at the bone/prosthesis interface. These findings support the use of dual-energy CT as a solid imaging base for clinical decision-making and the use of full-titanium or ceramic prostheses to allow for better CT visualization of the bone-prosthesis interface.


Assuntos
Artroplastia do Joelho , Artefatos , Metais/química , Interpretação de Imagem Radiográfica Assistida por Computador , Titânio/química , Cerâmica/química , Ligas de Cromo/química , Materiais Revestidos Biocompatíveis/química , Simulação por Computador , Humanos , Imagens de Fantasmas , Próteses e Implantes , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
8.
Eur Radiol ; 28(11): 4766-4774, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29761359

RESUMO

OBJECTIVES: To assess whether electronic cleansing (EC) of tagged residue and different computed tomography (CT) windows influence the size of colorectal polyps in CT colonography (CTC). METHODS: A database of 894 colonoscopy-validated CTC datasets of a low-prevalence cohort was retrospectively reviewed to identify patients with polyps ≥6 mm that were entirely submerged in tagged residue. Ten radiologists independently measured the largest diameter of each polyp, two-dimensionally, before and after EC in colon, bone, and soft-tissue-windows, in randomised order. Differences in size and polyp count before and after EC were calculated for size categories ≥6 mm and ≥10 mm. Statistical testing involved 95% confidence interval, intraclass correlation and mixed-model ANOVA. RESULTS: Thirty-seven patients with 48 polyps were included. Mean polyp size before EC was 9.8 mm in colon, 9.9 mm in bone and 8.2 mm in soft-tissue windows. After EC, the mean polyp size decreased significantly to 9.4 mm in colon, 9.1 mm in bone and 7.1 mm in soft-tissue windows. Compared to unsubtracted colon windows, EC, performed in colon, bone and soft-tissue windows, led to a shift of 6 (12,5%), 10 (20.8%) and 25 (52.1%) polyps ≥6 mm into the next smaller size category, thus affecting patient risk stratification. CONCLUSIONS: EC and narrow CT windows significantly reduce the size of polyps submerged in tagged residue. Polyp measurements should be performed in unsubtracted colon windows. KEY POINTS: • EC significantly reduces the size of polyps submerged in tagged residue. • Abdominal CT-window settings significantly underestimate 2D sizes of submerged polyps. • Size reduction in EC is significantly greater in narrow than wide windows. • Underestimation of polyp size due to EC may lead to inadequate treatment. • Polyp measurements should be performed in unsubtracted images using a colon window.


Assuntos
Pólipos do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/métodos , Processamento de Imagem Assistida por Computador/métodos , Idoso , Algoritmos , Análise de Variância , Colonografia Tomográfica Computadorizada/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Padrões de Referência , Estudos Retrospectivos , Sensibilidade e Especificidade
9.
Glob Chang Biol ; 22(7): 2608-19, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27061825

RESUMO

Correlative species distribution models have long been the predominant approach to predict species' range responses to climate change. Recently, the use of dynamic models is increasingly advocated for because these models better represent the main processes involved in range shifts and also simulate transient dynamics. A well-known problem with the application of these models is the lack of data for estimating necessary parameters of demographic and dispersal processes. However, what has been hardly considered so far is the fact that simulating transient dynamics potentially implies additional uncertainty arising from our ignorance of short-term climate variability in future climatic trends. Here, we use endemic mountain plants of Austria as a case study to assess how the integration of decadal variability in future climate affects outcomes of dynamic range models as compared to projected long-term trends and uncertainty in demographic and dispersal parameters. We do so by contrasting simulations of a so-called hybrid model run under fluctuating climatic conditions with those based on a linear interpolation of climatic conditions between current values and those predicted for the end of the 21st century. We find that accounting for short-term climate variability modifies model results nearly as differences in projected long-term trends and much more than uncertainty in demographic/dispersal parameters. In particular, range loss and extinction rates are much higher when simulations are run under fluctuating conditions. These results highlight the importance of considering the appropriate temporal resolution when parameterizing and applying range-dynamic models, and hybrid models in particular. In case of our endemic mountain plants, we hypothesize that smoothed linear time series deliver more reliable results because these long-lived species are primarily responsive to long-term climate averages.


Assuntos
Mudança Climática , Ecossistema , Plantas , Áustria , Modelos Teóricos , Incerteza
10.
Lasers Surg Med ; 48(10): 995-1005, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27252025

RESUMO

BACKGROUND: Antimicrobial Photodynamic therapy (aPDT) has demonstrated efficacy in situations where conventional antibiotic therapies can be challenged such as biofilms, gram-negative bacteria, and antimicrobial resistant organisms. Surface characteristics can affect biofilm adherence and integrity and so may modify the effectiveness of aPDT. This study investigates the killing efficacy of aPDT on S. mutans biofilms grown on relevant dental substrata, examining the killing efficacy and specifically the effects of aPDT on the biofilm matrix architecture. MATERIALS AND METHODS: S. mutans (NCTC 10449) was grown in 48 hours biofilms on different substrata, specifically glass, titanium, and denture acrylic. During aPDT assays, the biofilms were treated with a purpurin based sensitizer ([25 ug/ml] in DMSO) for 30 minutes, then exposed to a 664 nm diode laser at light doses of 15, 30, and 45 J/cm2 . Colony forming unit assays were performed to determine survival following treatment. Controls for comparison in survival assays consisted of (No light/No PS; No light/PS; and No light/DMSO). MAIR-IR spectroscopy analysis was performed to investigate aPDT effects on biofilm composition before and after jet impingement. RESULTS: Survival was greatly reduced in the biofilm cultures following the aPDT assays. All light doses achieved a greater then 3-log inactivation on 48 hours biofilms grown on polished denture acrylic. The higher light doses (45 and 30 J) achieved greater than 3-log inactivation in 48 hours biofilms grown on glass. The higher light doses (30 and 45 J/cm2 ) produced a 2-log inactivation in 48 hours biofilms grown on titanium. Multiple attenuated internal reflection infrared (MAIR-IR) spectroscopy data demonstrates enhanced loss of exopolysaccharide (EPS) and Amide in the aPDT treated biofilms following jet impingement. CONCLUSION: Antimicrobial PDT experiments using a purpurin based sensitizer and laser light doses of 15, 30, and 45 J/cm2 , against S. mutans biofilm grown on different surfaces, show the effectiveness of this therapy. In CFU survival assays, a dose response to the laser is evident. While considerable disinfection was achieved on all surfaces compared to the controls, not all surfaces could be disinfected equally. MAIR-IR spectroscopy showed that aPDT groups lost more EPS and Amide versus controls, suggesting aPDT induced biofilm embrittlement, which was revealed by jet impingement. With demonstrated efficacy against various microbes and on different substrata, antimicrobial aPDT shows potential for clinical application in biofilm-mediated diseases such as peri-implantitis and periodontitis. Lasers Surg. Med. 48:995-1005, 2016. © 2016 Wiley Periodicals, Inc.


Assuntos
Antibacterianos/farmacologia , Biofilmes/efeitos dos fármacos , Materiais Dentários , Viabilidade Microbiana/efeitos dos fármacos , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/farmacologia , Streptococcus mutans/efeitos dos fármacos , Streptococcus mutans/fisiologia
12.
Eur Radiol ; 25(7): 1865-74, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25680714

RESUMO

OBJECTIVE: To assess a radiologist's detection rate of rib fractures in trauma CT when reading curved planar reformats (CPRs) of the ribs compared to reading standard MPRs. METHODS: Two hundred and twenty trauma CTs (146 males, 74 females) were retrospectively subjected to a software algorithm to generate CPRs of the ribs. Patients were split into two equal groups. Sixteen patients were excluded due to insufficient segmentation, leaving 107 patients in group A and 97 patients in group B. Two radiologists independently evaluated group A using CPRs and group B using standard MPRs. Two different radiologists reviewed both groups with the inverse methods setting. Results were compared to a standard of reference created by two senior radiologists. RESULTS: The reference standard identified 361 rib fractures in 61 patients. Reading CPRs showed a significantly higher overall sensitivity (P < 0.001) for fracture detection than reading standard MPRs, with 80.9% (584/722) and 71.5% (516/722), respectively. Mean reading time was significantly shorter for CPRs (31.3 s) compared to standard MPRs (60.7 s; P < 0.001). CONCLUSION: Using CPRs for the detection of rib fractures accelerates the reading of trauma patient chest CTs, while offering an increased overall sensitivity compared to conventional standard MPRs. KEY POINTS: • In major blunt trauma, rib fractures are diagnosed with Computed Tomography. • Image processing can unfold all ribs into a single plane. • Unfolded ribs can be read twice as fast as axial images. • Unfolding the ribs allows a more accurate diagnosis of rib fractures.


Assuntos
Fraturas das Costelas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Criança , Pré-Escolar , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Lactente , Masculino , Pessoa de Meia-Idade , Traumatismo Múltiplo/diagnóstico por imagem , Variações Dependentes do Observador , Estudos Retrospectivos , Costelas/diagnóstico por imagem , Costelas/lesões , Sensibilidade e Especificidade , Traumatismos Torácicos/diagnóstico por imagem , Ferimentos não Penetrantes/diagnóstico por imagem , Adulto Jovem
13.
Endoscopy ; 46(10): 897-915, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25268304

RESUMO

This is an official guideline of the European Society of Gastrointestinal Endoscopy (ESGE) and the European Society of Gastrointestinal and Abdominal Radiology (ESGAR). It addresses the clinical indications for the use of computed tomographic colonography (CTC). A targeted literature search was performed to evaluate the evidence supporting the use of CTC. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was adopted to define the strength of recommendations and the quality of evidence. Main recommendations 1 ESGE/ESGAR recommend computed tomographic colonography (CTC) as the radiological examination of choice for the diagnosis of colorectal neoplasia. ESGE/ESGAR do not recommend barium enema in this setting (strong recommendation, high quality evidence). 2 ESGE/ESGAR recommend CTC, preferably the same or next day, if colonoscopy is incomplete. Delay of CTC should be considered following endoscopic resection. In the case of obstructing colorectal cancer, preoperative contrast-enhanced CTC may also allow location or staging of malignant lesions (strong recommendation, moderate quality evidence). 3 When endoscopy is contraindicated or not possible, ESGE/ESGAR recommend CTC as an acceptable and equally sensitive alternative for patients with symptoms suggestive of colorectal cancer (strong recommendation, high quality evidence). 4 ESGE/ESGAR recommend referral for endoscopic polypectomy in patients with at least one polyp  ≥  6  mm in diameter detected at CTC. CTC surveillance may be clinically considered if patients do not undergo polypectomy (strong recommendation, moderate quality evidence). 5 ESGE/ESGAR do not recommend CTC as a primary test for population screening or in individuals with a positive first-degree family history of colorectal cancer (CRC). However, it may be proposed as a CRC screening test on an individual basis providing the screenee is adequately informed about test characteristics, benefits, and risks (weak recommendation, moderate quality evidence).


Assuntos
Pólipos do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Pólipos do Colo/terapia , Colonografia Tomográfica Computadorizada/efeitos adversos , Colonoscopia , Contraindicações , Meios de Contraste , Detecção Precoce de Câncer , Humanos , Estadiamento de Neoplasias , Cuidados Pré-Operatórios , Conduta Expectante
14.
Eur Radiol ; 24(7): 1466-76, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24816931

RESUMO

OBJECTIVES: To assess the effectiveness of computer-aided detection (CAD) as a second reader or concurrent reader in helping radiologists who are moderately experienced in computed tomographic colonography (CTC) to detect colorectal polyps. METHODS: Seventy CTC datasets (34 patients: 66 polyps ≥6 mm; 36 patients: no abnormalities) were retrospectively reviewed by seven radiologists with moderate CTC experience. After primary unassisted evaluation, a CAD second read and, after a time interval of ≥4 weeks, a CAD concurrent read were performed. Areas under the receiver operating characteristic (ROC) curve (AUC), along with per-segment, per-polyp and per-patient sensitivities, and also reading times, were calculated for each reader with and without CAD. RESULTS: Of seven readers, 86% and 71% achieved a higher accuracy (segment-level AUC) when using CAD as second and concurrent reader respectively. Average segment-level AUCs with second and concurrent CAD (0.853 and 0.864) were significantly greater (p < 0.0001) than average AUC in the unaided evaluation (0.781). Per-segment, per-polyp, and per-patient sensitivities for polyps ≥6 mm were significantly higher in both CAD reading paradigms compared with unaided evaluation. Second-read CAD reduced readers' average segment and patient specificity by 0.007 and 0.036 (p = 0.005 and 0.011), respectively. CONCLUSIONS: CAD significantly improves the sensitivities of radiologists moderately experienced in CTC for polyp detection, both as second reader and concurrent reader. KEY POINTS: • CAD helps radiologists with moderate CTC experience to detect polyps ≥6 mm. • Second and concurrent read CAD increase the radiologist's sensitivity for detecting polyps ≥6 mm. • Second read CAD slightly decreases specificity compared with an unassisted read. • Concurrent read CAD is significantly more time-efficient than second read CAD.


Assuntos
Competência Clínica , Pólipos do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/métodos , Diagnóstico por Computador , Radiologia , Idoso , Algoritmos , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Recursos Humanos
15.
Lasers Surg Med ; 46(9): 712-7, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25154610

RESUMO

BACKGROUND AND OBJECTIVE: Moraxella catarrhalis is a significant cause of pediatric otitis media (OM), which is the most prevalent bacterial infection in children and primary reason for antibiotic administration in this population. Moreover, biofilm formation has been implicated as a primary mechanism of chronic or recurrent OM disease. As bacterial biofilms are inherently resistant to most antibiotics and these complex structures also present a significant challenge to the immune system, there is a clear need to identify novel antimicrobial approaches to treat OM infections. In this study, we evaluated the potential efficacy of antibacterial photodynamic therapy (aPDT) with porfimer sodium (Photofrin (PF)) against planktonic as well as biofilm-associated M. catarrhalis. MATERIALS AND METHODS: The bactericidal activity of aPDT with PF was assessed against multiple recent clinical isolates of M. catarrhalis grown planktonically as well as in biofilms. The bactericidal activity of PF-aPDT was quantified by enumeration of colony forming units post-treatment. The effect of aPDT on M. catarrhalis biofilms was further investigated with scanning electron microscopy (SEM) imaging. RESULTS: aPDT with PF significantly reduced M. catarrhalis viability. Although PF-aPDT caused higher killing in planktonic grown organisms (5-6 log kill), biofilm grown bacteria also demonstrated a statistically significant reduction in viable organisms (3-4 log decrease in recoverable bacteria) following treatment as compared to saline only controls (P < 0.01). SEM studies indicated the PF-aPDT treated bacteria exhibited prominent morphological changes with visibly distorted cell membranes. CONCLUSIONS: aPDT with PF elicits significant bactericidal activity against both planktonic and biofilm-associated M. catarrhalis, suggesting this technology warrants further analysis as a potential novel antimicrobial treatment for acute or recurrent OM.


Assuntos
Biofilmes/efeitos dos fármacos , Éter de Diematoporfirina/farmacologia , Moraxella catarrhalis/efeitos dos fármacos , Moraxella catarrhalis/crescimento & desenvolvimento , Fotoquimioterapia , Fármacos Fotossensibilizantes/farmacologia , Biofilmes/crescimento & desenvolvimento , Biofilmes/efeitos da radiação , Lasers de Corante , Lasers de Estado Sólido , Viabilidade Microbiana/efeitos dos fármacos , Viabilidade Microbiana/efeitos da radiação , Moraxella catarrhalis/efeitos da radiação
16.
Eur Radiol ; 23(3): 720-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22983280

RESUMO

OBJECTIVE: To update quality standards for CT colonography based on consensus among opinion leaders within the European Society of Gastrointestinal and Abdominal Radiology (ESGAR). MATERIAL AND METHODS: A multinational European panel of nine members of the ESGAR CT colonography Working Group (representing six EU countries) used a modified Delphi process to rate their level of agreement on a variety of statements pertaining to the acquisition, interpretation and implementation of CT colonography. Four Delphi rounds were conducted, each at 2 months interval. RESULTS: The panel elaborated 86 statements. In the final round the panelists achieved complete consensus in 71 of 86 statements (82 %). Categories including the highest proportion of statements with excellent Cronbach's internal reliability were colon distension, scan parameters, use of intravenous contrast agents, general guidelines on patient preparation, role of CAD and lesion measurement. Lower internal reliability was achieved for the use of a rectal tube, spasmolytics, decubitus positioning and number of CT data acquisitions, faecal tagging, 2D vs. 3D reading, and reporting. CONCLUSION: The recommendations of the consensus should be useful for both the radiologist who is starting a CTC service and for those who have already implemented the technique but whose practice may need updating.


Assuntos
Colonografia Tomográfica Computadorizada/normas , Guias de Prática Clínica como Assunto , Radiologia/normas , Europa (Continente)
17.
Lasers Med Sci ; 28(1): 343-7, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22821150

RESUMO

The aim of this in vitro study was to evaluate the effect of laser treatment on shear bond strength of a self-adhesive flowable resin composite to human dentin. Eighty extracted sound human molar teeth were used for the study. The teeth were sectioned mesiodistally and embedded in acrylic blocks. The dentin surfaces were ground wet with 600-grit silicon carbide (SiC) paper. They were randomly divided into two preparation groups: laser (Er:YAG laser, with 12 Hz, 350 mJ energy) and control (SiC). Each group was then divided into two subgroups according to the flowable resin composite type (n = 20). A self-adhesive flowable (Vertise Flow) and a conventional flowable resin (Premise Flow) were used. Flowable resin composites were applied according to the manufacturer's recommendations using the Ultradent shear bond Teflon mold system. The bonded specimens were stored in water at 37 °C for 24 h. Shear bond strength was tested at 1 mm/min. The data were logarithmically transformed and analyzed using two-way analysis of variance and Student-Newman-Keul's test at a significance level of 0.05. The self-adhesive flowable resin showed significantly higher bond strength values to laser-prepared surfaces than to SiC-prepared surfaces (p < 0.001). The conventional flowable resin did not show such differences (p = 0.224). While there was a significant difference between the two flowable resin composites in SiC-prepared surfaces (p < 0.001), no significant difference was detected in laser-prepared surfaces (p = 0.053). The bond strength of a self-adhesive flowable resin composite differs according to the type of dentin surface preparation. Laser treatment increased the dentin bonding values of the self-adhesive flowable resin.


Assuntos
Resinas Compostas/química , Adesivos Dentinários/química , Lasers de Estado Sólido , Cimentos de Resina/química , Análise de Variância , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Dente Molar , Distribuição Aleatória , Propriedades de Superfície
18.
Radiologie (Heidelb) ; 63(6): 418-428, 2023 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-37249607

RESUMO

BACKGROUND: Dedicated radiological expertise and a high-quality examination, performed according to current technical standards and for accepted indications, are prerequisite to achieve excellent results with CT colonography (CTC). OBJECTIVES: The aim of this article is to review current standards of the examination technique as well as indications and contraindications for CTC based on recent recommendations and guidelines. MATERIALS AND METHODS: Based on extensive literature research, current knowledge about the examination technique and the indications and contraindications is summarized. RESULTS: CTC is the radiological examination of choice for the detection of colorectal neoplasia. Beside incomplete or refused colonoscopy and contraindications to colonoscopy, CTC is also a noninvasive option for opportunistic colorectal cancer screening. The examination technique is based on a CTC-specific patient preparation scheme that includes fecal tagging, colonic distension, low-dose CT scans in two patient positions and a combined 2D and 3D data evaluation. CONCLUSIONS: Performing CTC according to current technical standards is prerequisite for high-quality examinations and is, thus, also a key factor to obtain a correct diagnosis. CTC is a noninvasive examination, capable of providing clinically relevant diagnoses for a wide range of indications.


Assuntos
Colonografia Tomográfica Computadorizada , Neoplasias Colorretais , Humanos , Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/diagnóstico por imagem , Colonoscopia , Contraindicações
19.
Radiologie (Heidelb) ; 63(6): 441-450, 2023 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-37219728

RESUMO

BACKGROUND: Early diagnosis of a luminal colonic disease is of essential clinical importance to start timely optimised therapy and detect complications early. OBJECTIVES: This paper aims to provide an overview of the use of radiological methods in diagnosing neoplastic and inflammatory luminal diseases of the colon. Characteristic morphological features are discussed and compared. MATERIALS AND METHODS: Based on an extensive literature review, the current state of knowledge regarding the imaging diagnosis of luminal pathologies of the colon and their importance in patient management is presented. RESULTS: Technological advances in imaging have made the diagnosis of neoplastic and inflammatory colonic diseases using abdominal computed tomography and magnetic resonance imaging the established standard. Imaging is performed as part of the initial diagnosis in clinically symptomatic patients, to exclude complications, as a follow-up assessment under therapy and as an optional screening method in asymptomatic individuals. CONCLUSIONS: Accurate knowledge of the radiological manifestations of the numerous luminal disease patterns, the typical distribution pattern and characteristic bowel wall changes are essential to improve diagnostic decision-making.


Assuntos
Doenças do Colo , Humanos , Doenças do Colo/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Imageamento por Ressonância Magnética/métodos
20.
EClinicalMedicine ; 65: 102267, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37876998

RESUMO

Background: Ultra-low-dose CT (ULDCT) examinations of the chest at only twice the radiation dose of a chest X-ray (CXR) now offer a valuable imaging alternative to CXR. This trial prospectively compares ULDCT and CXR for the detection rate of diagnoses and their clinical relevance in a low-prevalence cohort of non-traumatic emergency department patients. Methods: In this prospective crossover cohort trial, 294 non-traumatic emergency department patients with a clinically indicated CXR were included between May 2nd and November 26th of 2019 (www.clinicaltrials.gov: NCT03922516). All participants received both CXR and ULDCT, and were randomized into two arms with inverse reporting order. The detection rate of CXR was calculated from 'arm CXR' (n = 147; CXR first), and of ULDCT from 'arm ULDCT' (n = 147; ULDCT first). Additional information reported by the second exam in each arm was documented. From all available clinical and imaging data, expert radiologists and emergency physicians built a compound reference standard, including radiologically undetectable diagnoses, and assigned each finding to one of five clinical relevance categories for the respective patient. Findings: Detection rates for main diagnoses by CXR and ULDCT (mean effective dose: 0.22 mSv) were 9.1% (CI [5.2, 15.5]; 11/121) and 20.1% (CI [14.2, 27.7]; 27/134; P = 0.016), respectively. As an additional imaging modality, ULDCT added 9.1% (CI [5.2, 15.5]; 11/121) of main diagnoses to prior CXRs, whereas CXRs did not add a single main diagnosis (0/134; P < 0.001). Notably, ULDCT also offered higher detection rates than CXR for all other clinical relevance categories, including findings clinically irrelevant for the respective emergency department visit with 78.5% (CI [74.0, 82.5]; 278/354) vs. 16.2% (CI [12.7, 20.3]; 58/359) as a primary modality and 68.2% (CI [63.3, 72.8]; 245/359) vs. 2.5% (CI [1.3, 4.7]; 9/354) as an additional imaging modality. Interpretation: In non-traumatic emergency department patients, ULDCT of the chest offered more than twice the detection rate for main diagnoses compared to CXR. Funding: The Department of Biomedical Imaging and Image-guided Therapy of Medical University of Vienna received funding from Siemens Healthineers (Erlangen, Germany) to employ two research assistants for one year.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA