Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Exp Physiol ; 108(12): 1560-1568, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37824038

RESUMO

Compression sonography has been proposed as a method for non-invasive measurement of venous pressures during spaceflight, but initial reports of venous pressure measured by compression ultrasound conflict with prior reports of invasively measured central venous pressure (CVP). The aim of this study is to determine the agreement of compression sonography of the internal jugular vein (IJVP) with invasive measures of CVP over a range of pressures relevant to microgravity exposure. Ten healthy volunteers (18-55 years, five female) completed two 3-day sessions of supine bed rest to simulate microgravity. IJVP and CVP were measured in the seated position, and in the supine position throughout 3 days of bed rest. The range of CVP recorded was in line with previous reports of CVP during changes in posture on Earth and in microgravity. The correlation between IJVP and CVP was poor when measured during spontaneous breathing (r = 0.29; R2  = 0.09; P = 0.0002; standard error of the estimate (SEE) = 3.0 mmHg) or end-expiration CVP (CVPEE ; r = 0.19; R2  = 0.04; P = 0.121; SEE = 3.0 mmHg). There was a modest correlation between the change in CVP and the change in IJVP for both spontaneous ΔCVP (r = 0.49; R2  = 0.24; P < 0.0001) and ΔCVPEE (r = 0.58; R2  = 0.34; P < 0.0001). Bland-Altman analysis of IJVP revealed a large positive bias compared to spontaneous breathing CVP (3.6 mmHg; SD = 4.0; CV = 85%; P < 0.0001) and CVPEE (3.6 mmHg; SD = 4.2; CV = 84%; P < 0.0001). Assessment of absolute IJVP via compression sonography correlated poorly with direct measurements of CVP by invasive catheterization over a range of venous pressures that are physiologically relevant to spaceflight. However, compression sonography showed modest utility for tracking changes in venous pressure over time. NEW FINDINGS: What is the central question of this study? Compression sonography has been proposed as a novel method for non-invasive measurement of venous pressures during spaceflight. However, the accuracy has not yet been confirmed in the range of CVP experienced by astronauts during spaceflight. What is the main finding and its importance? Our data show that compression sonography of the internal jugular vein correlates poorly with direct measurement of central venous pressures in a range that is physiologically relevant to spaceflight. However, compression sonography showed modest utility for tracking changes in venous pressure over time.


Assuntos
Repouso em Cama , Veias Jugulares , Humanos , Feminino , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/fisiologia , Pressão Venosa , Pressão Venosa Central/fisiologia , Ultrassonografia
2.
JAMA Ophthalmol ; 140(1): 59-65, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34882176

RESUMO

IMPORTANCE: Astronauts returning from long-duration spaceflight experience ocular remodeling related to cephalad fluid shifts induced by microgravity. It is hypothesized that the absence of diurnal reductions in intracranial pressure in microgravity creates a low but persistent pressure gradient at the posterior aspect of the eye, which results in ocular remodeling and space-associated neuro-ocular syndrome (SANS) over many months. OBJECTIVE: To determine whether partial reintroduction of footward fluid shifts during simulated microgravity via lower body negative pressure (LBNP) during sleep attenuates choroid engorgement, an early marker of ocular remodeling related to SANS. DESIGN, SETTING, AND PARTICIPANTS: Between May 2019 and February 2020, participants with no major cardiovascular, kidney, or ophthalmic disease completed 3 days of supine (0°) bed rest with and 3 days without 8 hours of nightly LBNP in a randomized, crossover design. This single-center investigation took place at the UT Southwestern Medical Center. All analyses were conducted blinded to condition and time point. INTERVENTIONS: Eight hours of nightly LBNP (-20 mm Hg) vs no LBNP. MAIN OUTCOMES AND MEASURES: The primary outcome was the change in choroid area and volume after 3 days of bed rest measured by optical coherence tomography. RESULTS: Of 10 participants, 5 were female, the mean (SD) age was 29 (9) years, and the age range was 18 to 55 years. Central venous pressure increased from the seated to supine position (mean [SD], seated: -2.3 [2.0] vs supine: 6.9 [2.0] mm Hg; P < .001), leading to choroid engorgement over 3 days of bed rest (Δ area: +0.09 mm2 [95% CI, 0.04-0.13]; P = .001; Δ volume: +0.37 mm3 [95% CI, 0.19-0.55]; P = .001). Nightly LBNP caused a sustained reduction in supine central venous pressure (mean [SD], 5.7 [2.2] mm Hg to 1.2 [1.4 mm Hg]; P < .001) and attenuated the increase in choroid area (74%) (Δ: 0.02 mm2 [95% -0.02 to 0.06]; P = .01) and volume (53%) (Δ: 0.17 mm3 [95% CI, 0.01-0.34]; P = .05) compared with control. CONCLUSIONS AND RELEVANCE: Nightly LBNP reinstated a footward fluid shift and mitigated the increase in choroid area and volume. LBNP during sleep may be an effective countermeasure for ocular remodeling and SANS during long-duration space missions.


Assuntos
Hiperemia , Voo Espacial , Ausência de Peso , Adolescente , Adulto , Astronautas , Corioide , Estudos Cross-Over , Feminino , Humanos , Pressão Negativa da Região Corporal Inferior , Masculino , Pessoa de Meia-Idade , Síndrome , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA