Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ann Biol Clin (Paris) ; 70(2): 141-54, 2012.
Artigo em Francês | MEDLINE | ID: mdl-22484525

RESUMO

Using hematology analysers, white blood cell (WBC) counts and differentials (either three or five parameters) may be ascertained after Red Blood Cell (RBC) lysis and analysis using either impedance and/or optical (laser) technology. Cells or particles not destroyed by lytic agents are enumerated as WBC: abnormal particles may be observed on WBC differential scattergrams, if performed, appearing as a variable number of dots, which location may help to ascertain the nature of the abnormality. Spuriously low WBC counts are rare, mainly related to agglutination in the presence of ethylenediamine tetra-acetic acid. Cryoglobulins, lipids, insufficiently lysed RBC, erythroblasts and platelet aggregates are common situations increasing WBC counts. So far, many current high performance analysers clearly identify and enumerate erythroblasts now. In normal patients and in reactive disorders automated differential provides true and accurate results. However, failure to enumerate accurately basophilic granulocytes and monocytes is not uncommon. Using myeloperoxidase cytochemistry to ascertain differential may lead to slide review if the enzyme expression is low or absent. Low number of abnormal cells (blasts, lymphoma cells, dysplastic granulocytes) may be missed, more frequently if leukopenia is present. In many but not all instances flagging and/or an abnormal WBC differential scattergram will alert the operator. Although these flags are sensitive enough to allow the identification of several spurious counts, only the most sophisticated analysers have optimal flagging, whereas more simple ones, especially those without a WBC differential scattergram, do not demonstrate the same sensitivity for the detection of abnormal results.


Assuntos
Automação Laboratorial/instrumentação , Erros de Diagnóstico/estatística & dados numéricos , Doenças Hematológicas/diagnóstico , Hematologia/instrumentação , Hematologia/normas , Automação Laboratorial/normas , Contagem de Eritrócitos/instrumentação , Contagem de Eritrócitos/normas , Contagem de Eritrócitos/estatística & dados numéricos , Reações Falso-Negativas , Reações Falso-Positivas , Doenças Hematológicas/sangue , Hematologia/métodos , Humanos , Contagem de Leucócitos/estatística & dados numéricos , Projetos de Pesquisa
2.
Ann Biol Clin (Paris) ; 70(2): 155-68, 2012.
Artigo em Francês | MEDLINE | ID: mdl-22484526

RESUMO

Several situations lead to abnormal haemoglobin measurement or to abnormal red blood cells (RBC) counts, including hyperlipemias, agglutinins and cryoglobulins, haemolysis, or elevated white blood cells (WBC) counts. Mean (red) cell volume may be also subject to spurious determination, because of agglutinins (mainly cold), high blood glucose level, natremia, anticoagulants in excess and at times technological considerations. Abnormality related to one measured parameter eventually leads to abnormal calculated RBC indices: mean cell haemoglobin content is certainly the most important RBC parameter to consider, maybe as important as flags generated by the haematology analysers (HA) themselves. In many circumstances, several of the measured parameters from cell blood counts (CBC) may be altered, and the discovery of a spurious change on one parameter frequently means that the validity of other parameters should be considered. Sensitive flags allow now the identification of several spurious counts, but only the most sophisticated HA have optimal flagging, and simpler ones, especially those without any WBC differential scattergram, do not share the same capacity to detect abnormal results. Reticulocytes are integrated into the CBC in many HA, and several situations may lead to abnormal counts, including abnormal gating, interference with intraerythrocytic particles, erythroblastosis or high WBC counts.


Assuntos
Automação Laboratorial/instrumentação , Índices de Eritrócitos , Eritrócitos/citologia , Doenças Hematológicas/diagnóstico , Hematologia/instrumentação , Hemoglobinas/análise , Automação Laboratorial/normas , Erros de Diagnóstico , Contagem de Eritrócitos/instrumentação , Contagem de Eritrócitos/métodos , Contagem de Eritrócitos/normas , Índices de Eritrócitos/fisiologia , Doenças Hematológicas/sangue , Hematologia/métodos , Hematologia/normas , Humanos , Reprodutibilidade dos Testes , Projetos de Pesquisa , Contagem de Reticulócitos/instrumentação , Contagem de Reticulócitos/métodos , Contagem de Reticulócitos/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA