Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 31(Pt 2): 385-393, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38300130

RESUMO

As a representative of the fourth-generation light sources, the High Energy Photon Source (HEPS) in Beijing, China, utilizes a multi-bend achromat lattice to obtain an approximately 100 times emittance reduction compared with third-generation light sources. New technologies bring new challenges to operate the storage ring. In order to meet the beam commissioning requirements of HEPS, a new framework for the development of high-level applications (HLAs) has been created. The key part of the new framework is a dual-layer physical module to facilitate the seamless fusion of physical simulation models with the real machine, allowing for fast switching between different simulation models to accommodate the various simulation scenarios. As a framework designed for development of physical applications, all variables are based on physical quantities. This allows physicists to analytically assess measurement parameters and optimize machine parameters in a more intuitive manner. To enhance both extensibility and adaptability, a modular design strategy is utilized, partitioning the entire framework into discrete modules in alignment with the requirements of HLA development. This strategy not only facilitates the independent development of each module but also minimizes inter-module coupling, thereby simplifying the maintenance and expansion of the entire framework. To simplify the development complexity, the design of the new framework is implemented using Python and is called Python-based Accelerator Physics Application Set (Pyapas). Taking advantage of Python's flexibility and robust library support, we are able to develop and iterate quickly, while also allowing for seamless integration with other scientific computing applications. HLAs for both the HEPS linac and booster have been successfully developed. During the beam commissioning process at the linac, Pyapas's ease of use and reliability have significantly reduced the time required for the beam commissioning operators. As a development framework for HLA designed for the new-generation light sources, Pyapas has the versatility to be employed with HEPS, as well as with other comparable light sources, due to its adaptability.

2.
Transl Stroke Res ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38558011

RESUMO

Intracerebral hemorrhage (ICH) is the most serious form of stroke and has limited available therapeutic options. As knowledge on ICH rapidly develops, cutting-edge techniques in the fields of surgical robots, regenerative medicine, and neurorehabilitation may revolutionize ICH treatment. However, these new advances still must be translated into clinical practice. In this review, we examined several emerging therapeutic strategies and their major challenges in managing ICH, with a particular focus on innovative therapies involving robot-assisted minimally invasive surgery, stem cell transplantation, in situ neuronal reprogramming, and brain-computer interfaces. Despite the limited expansion of the drug armamentarium for ICH over the past few decades, the judicious selection of more efficacious therapeutic modalities and the exploration of multimodal combination therapies represent opportunities to improve patient prognoses after ICH.

3.
Transl Stroke Res ; 2023 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-38157144

RESUMO

Intracerebral hemorrhage (ICH) is the second major stroke type, with high incidence, high disability rate, and high mortality. At present, there is no effective and reliable treatment for ICH. As a result, most patients have a poor prognosis. Minimally invasive surgery (MIS) is the fastest treatment method to remove hematoma, which is characterized by less trauma and easy operation. Some studies have confirmed the safety of MIS, but there are still no reports showing that it can significantly improve the functional outcome of ICH patients. Intracranial pressure (ICP) monitoring is considered to be an important part of successful treatment in traumatic brain diseases. By monitoring ICP in real time, keeping stable ICP could help patients with craniocerebral injury get a good prognosis. In the course of MIS treatment of ICH patients, keeping ICP stable may also promote patient recovery. In this review, we will take ICP monitoring as the starting point for an in-depth discussion.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA