Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 255
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Herz ; 41(1): 10-8, 2016 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-26659846

RESUMO

Mitral valve (MV) disease is one of the most common heart valve diseases. The surgical and interventional treatment for MV disease requires a multidisciplinary approach. For primary mitral valve regurgitation (MVR) surgical MV repair is the treatment of choice, which can be performed with an excellent outcome and long-term survival in reference centers. The surgical technique used for MV repair depends on the pathological mechanism, the morphological dimensions of the MV, the operative risk and the expertise of the cardiac surgeon. The surgical and interventional treatment of secondary MVVR is the subject of on-going discussions. In patients with moderate secondary MVR undergoing coronary artery bypass grafting, concomitant MV repair should be performed. In the presence of severe secondary MR with risk factors for failure of MV repair, patients should consider having MV replacement. In the rare cases of patients presenting with mitral valve stenosis (MVS) MV repair can be considered in young patients and who are most often treated with MV replacement. The choice between biological or mechanical MV replacement depends on the pathophysiology, the comorbidities, the amount of anticoagulation necessary and the age of the patient. New percutaneous techniques for MV replacement offer new treatment options for reoperation in high-risk patients.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Terapia Combinada/métodos , Próteses Valvulares Cardíacas , Humanos , Procedimentos de Cirurgia Plástica/instrumentação
2.
Perfusion ; 30(2): 154-60, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24988948

RESUMO

OBJECTIVES: Mechanical lung assist (MLA; extracorporeal membrane oxygenation (ECMO) or extracorporeal lung assist (ECLA)) is increasingly used as a temporary bridge to lung transplantation (LTx). This study was designed to evaluate the impact of preoperative MLA on the operative outcome, including longer-term survival, in comparison to patients undergoing LTx without preoperative MLA. METHODS: A total of 143 patients underwent LTx at our institution from 2002 to 2011. Forty-three percent (n=62) of patients presented with idiopathic pulmonary fibrosis and 71% (n=102) presented with severely elevated pulmonary artery pressure. RESULTS: Thirteen patients (9.1%) required pre-LTx MLA support (age 44 ±13 years, double LTx 73.3%, female gender 53%) whereas 130 patients did not (age 52 ±11 years, double LTx 41.5%, female gender 36.9%). In one patient, MLA was successfully weaned and the patient underwent subsequent LTx. All patients in the MLA group were intraoperatively supported with continuous ECMO. One patient had to be supported with MLA after LTx for a period of 8 days. The short-term and mid-term postoperative survival of the MLA patient group was not significantly different from the non-MLA group (LogRank p=0.28). The 30-day, 90-day and 1-year survivals were 95%, 90% and 71%, respectively, in the patients without MLA compared to 85%, 77% and 68% in the MLA group. CONCLUSIONS: MLA has no impact on long-term survival rate in LTx patients, but has an influence in postoperative survival. MLA support is a valuable tool to bridge unstable patients to LTx.


Assuntos
Oxigenação por Membrana Extracorpórea , Hipertensão Pulmonar , Fibrose Pulmonar Idiopática , Transplante de Pulmão , Cuidados Pré-Operatórios , Respiração Artificial , Adulto , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Hipertensão Pulmonar/mortalidade , Hipertensão Pulmonar/cirurgia , Fibrose Pulmonar Idiopática/mortalidade , Fibrose Pulmonar Idiopática/cirurgia , Masculino , Pessoa de Meia-Idade , Taxa de Sobrevida
3.
Int J Obes (Lond) ; 38(8): 1061-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24166068

RESUMO

BACKGROUND: Bladder dysfunction has one of the highest prevalences as a comorbidity of obesity in industrialized countries. The aetiopathogenesis of obesity-associated bladder dysfunction is still obscure, but there is growing evidence that general metabolic changes in obese patients may be in part responsible. As demonstrated recently, high fat diet (HFD) significantly alters the protein expression in the urinary bladder, activates multiple signalling pathways associated with cell survival and inflammation and ultimately provokes bladder fibrosis in an obese rat model. The study aimed to elucidate the role of matrix metalloproteases (MMPs) and their specific tissue inhibitors of metalloproteases (TIMPs) in obesity-related bladder extracellular matrix (ECM) remodelling and the effect of weight loss surgery via sleeve gastrectomy (SG) on phenotype and molecular parameters. METHODS: Twenty-four male Sprague-Dawley rats were used for (i) characterization of the HFD phenotype and (ii) evaluation of alterations following SG. Metabolic status, the degree of bladder fibrosis and tissue expression and activity of MMP2, MMP9, MMP14, TIMP1 and TIMP2 were analysed by immunohistochemistry, enzyme-linked immunosorbent assay and activity assays. Statistical differences were calculated by analysis of variance or independent Student's t-test. A P-value <0.05 was considered statistically significant. RESULTS: In HFD rats, we found significant alterations in lipid metabolism, fat mass, free fatty acid profile, insulin resistance and inflammatory markers. Voided volume was significantly decreased, and bladder showed marked fibrosis. MMPs and TIMPs were differentially regulated depending on animal status (controls, chow diet, HFD, and SG- and sham-operated animals) in both urothelium and detrusor smooth muscle. Although animal weight and most metabolic parameters were positively affected by SG, bladder fibrosis persisted. The limitations of this study were 1 month follow-up and lack of direct measurement of bladder function. CONCLUSIONS: Early diagnosis of the bladder dysfunction associated with obesity is essential to allow targeted early intervention, that is, before manifestation of potentially irreversible ECM fibrotic alterations.


Assuntos
Dieta Hiperlipídica/efeitos adversos , Metaloproteinases da Matriz/metabolismo , Obesidade/metabolismo , Obesidade/cirurgia , Doenças da Bexiga Urinária/patologia , Bexiga Urinária/patologia , Redução de Peso , Animais , Cirurgia Bariátrica , Células Cultivadas , Modelos Animais de Doenças , Ensaio de Imunoadsorção Enzimática , Fibrose , Metabolismo dos Lipídeos , Masculino , Obesidade/complicações , Obesidade/enzimologia , Obesidade/patologia , Ratos , Ratos Sprague-Dawley , Doenças da Bexiga Urinária/enzimologia , Doenças da Bexiga Urinária/etiologia , Doenças da Bexiga Urinária/cirurgia
4.
Clin Exp Immunol ; 176(1): 120-8, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24329680

RESUMO

Extracorporeal photopheresis (ECP) has been used as a prophylactic and therapeutic option to avoid and treat rejection after heart transplantation (HTx). Tolerance-inducing effects of ECP such as up-regulation of regulatory T cells (T(regs)) are known, but specific effects of ECP on regulatory T cell (T(reg)) subsets and dendritic cells (DCs) are lacking. We analysed different subsets of T(regs) and DCs as well as the immune balance status during ECP treatment after HTx. Blood samples were collected from HTx patients treated with ECP for prophylaxis (n = 9) or from patients with histologically proven acute cellular rejection (ACR) of grade ≥ 1B (n = 9), as well as from control HTx patients without ECP (HTxC; n = 7). Subsets of T(regs) and DCs as well as different cytokine levels were analysed. Almost 80% of the HTx patients showed an effect to ECP treatment with an increase of T(regs) and plasmacytoid DCs (pDCs). The percentage of pDCs before ECP treatment was significantly higher in patients with no ECP effect (26·3% ± 5·6%) compared to patients who showed an effect to ECP (9·8% ± 10·2%; P = 0·011). Analysis of functional subsets of CD4⁺CD25(high)CD127(low) T(regs) showed that CD62L-, CD120b- and CD147-positive T(regs) did not differ between the groups. CD39-positive T(regs) increased during ECP treatment compared to HTxC. ECP-treated patients showed higher levels for T helper type 1 (Th1), Th2 and Th17 cytokines. Cytokine levels were higher in HTx patients with rejection before ECP treatment compared to patients with prophylactic ECP treatment. We recommend a monitoring strategy that includes the quantification and analysis of T(regs), pDCs and the immune balance status before and up to 12 months after starting ECP.


Assuntos
Rejeição de Enxerto/imunologia , Transplante de Coração/métodos , Monitorização Imunológica/métodos , Fotoferese/métodos , Doença Aguda , Adulto , Idoso , Basigina/imunologia , Basigina/metabolismo , Complexo CD3/imunologia , Complexo CD3/metabolismo , Citocinas/imunologia , Citocinas/metabolismo , Células Dendríticas/imunologia , Feminino , Rejeição de Enxerto/sangue , Humanos , Integrina beta1/imunologia , Integrina beta1/metabolismo , Subunidade alfa de Receptor de Interleucina-2/imunologia , Subunidade alfa de Receptor de Interleucina-2/metabolismo , Subunidade alfa de Receptor de Interleucina-7/imunologia , Subunidade alfa de Receptor de Interleucina-7/metabolismo , Masculino , Pessoa de Meia-Idade , Linfócitos T Reguladores/imunologia , Linfócitos T Reguladores/metabolismo , Células Th1/imunologia , Células Th1/metabolismo , Células Th17/imunologia , Células Th17/metabolismo , Células Th2/imunologia , Células Th2/metabolismo , Fatores de Tempo
5.
Z Gastroenterol ; 52(8): 813-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25111721

RESUMO

Invasive aspergillus infection occurs in 5 - 42 % of liver-transplanted recipients and is a dangerous complication, associated with high mortality if untreated. However, the early diagnosis of invasive aspergillosis can be elusive, as clinical signs are unspecific and the pathogenic agent is difficult to demonstrate. We here report about a 58-year-old man with acute liver failure caused by newly diagnosed chronic hepatitis B infection who underwent liver transplantation. The postoperative course was uneventful, and the patient was discharged after 30 days. After 105 days the patient was readmitted because of fever, recurrent chest and abdominal pain. Computed tomography revealed a cardiac lesion; other diagnostic steps including bone-marrow and endomycordial biopsy, virological and microbiological investigations gave no clear findings. To exclude a malignant process, thoracotomy with mass and simultaneous lower left lobe resection were performed. Histopathological findings revealed an invasive perimyocardial aspergillosis. Immediate intravenous therapy with voriconazole and caspofungin was initiated and monitoring of the mass was performed with transesophageal echocardiography and Cardio-MRI. Due to slightly increase of the lesion, medication was switched to posaconazole and caspofungin. Under this dual fungal treatment the lesion regressed and the patient could be discharged after two months in good clinical condition. Frequent Cardio-MRI scan after discharge showed further mass-regression. Therefore antifungal treatment was switched to oral posaconazole mono-therapy. After one year, complete reduction of the mass was achieved and antifungal therapy was discontinued. Recent diagnostic imaging follow-up showed no pathological finding.


Assuntos
Hepatite B/cirurgia , Falência Hepática/cirurgia , Transplante de Fígado , Miocardite/diagnóstico , Infecções Oportunistas/diagnóstico , Complicações Pós-Operatórias/diagnóstico , Aspergilose Pulmonar/diagnóstico , Doença Aguda , Caspofungina , Quimioterapia Combinada , Equinocandinas/uso terapêutico , Ecocardiografia Transesofagiana , Humanos , Lipopeptídeos , Pulmão/patologia , Pulmão/cirurgia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Miocardite/tratamento farmacológico , Miocardite/patologia , Miocárdio/patologia , Infecções Oportunistas/tratamento farmacológico , Infecções Oportunistas/patologia , Complicações Pós-Operatórias/patologia , Aspergilose Pulmonar/tratamento farmacológico , Aspergilose Pulmonar/patologia , Triazóis/uso terapêutico
6.
Eur J Vasc Endovasc Surg ; 46(6): 651-6, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24099957

RESUMO

OBJECTIVE: The aim of this study was to evaluate the feasibility of non-invasive monitoring of the paraspinous collateral network (CN) oxygenation prior to, during, and after thoracoabdominal aortic repair in a clinical series. METHODS: Near-infrared spectroscopy optodes were positioned bilaterally-over the thoracic and lumbar paraspinous vasculature-to transcutaneously monitor muscle oxygenation of the CN in 20 patients (age: 66 ± 10 years; men = 11) between September 2010 and April 2012; 15 had open thoracoabdominal aortic repair (Crawford II and III), three had thoracic endovascular aortic repair (TEVAR; Crawford I), and two had a hybrid repair (Crawford II). CN oxygenation was continuously recorded until 48 hours postoperatively. RESULTS: Hospital mortality was 5% (n = 1), 15% suffered ischemic spinal cord injury (SCI). Mean thoracic CN oxygenation saturation was 75.5 ± 8% prior to anesthesia (=baseline) without significant variations throughout the procedure (during non-pulsatile cooling on cardiopulmonary bypass and with aortic cross-clamping; range = 70.6-79.5%). Lumbar CN oxygenation (LbS) dropped significantly after proximal aortic cross-clamping to a minimum after 11.7 ± 4 minutes (74 ± 13% of baseline), but fully recovered after restoration of pulsatile flow to 98.5% of baseline. During TEVAR, stent-graft deployment did not significantly affect LbS. Three patients developed relevant SCI (paraplegia n = 1/paraparesis n = 2). In these patients LbS reduction after aortic cross-clamping was significantly lower compared with patients who did not experience SCI (p = .041). CONCLUSIONS: Non-invasive monitoring of CN oxygenation prior to, during, and after thoracoabdominal aortic repair is feasible. Lumbar CN oxygenation levels directly respond to compromise of aortic blood circulation.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Circulação Colateral , Isquemia/prevenção & controle , Monitorização Intraoperatória/métodos , Espectroscopia de Luz Próxima ao Infravermelho , Medula Espinal/irrigação sanguínea , Idoso , Aorta Abdominal/cirurgia , Aorta Torácica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Estudos de Viabilidade , Feminino , Mortalidade Hospitalar , Humanos , Isquemia/etiologia , Masculino , Músculo Esquelético/irrigação sanguínea , Paraplegia/etiologia , Paraplegia/prevenção & controle , Paresia/etiologia , Paresia/prevenção & controle , Projetos Piloto , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Stents
7.
Thorac Cardiovasc Surg ; 61(8): 651-5, 2013 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-24072516

RESUMO

Current evolutions and substantial amendments of the German health care system in combination with distinguished progress in cardiac surgery over the past years require both a reflection of principles in patient-centered care and an update of basic standard requirements for a department of cardiac surgery in Germany. In due consideration of the data from the voluntary registry of the German Society for Thoracic and Cardiovascular Surgery, this article accurately defines core requirements for a cardiac surgical department (cardiac surgery on-site), subdivided into facilities, staff and processes. If based on these standards, one may anticipate that cardiac surgical care is performed under appropriate conditions leading to an intrinsic benefit for patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos/normas , Serviço Hospitalar de Cardiologia/normas , Atenção à Saúde/normas , Avaliação de Processos e Resultados em Cuidados de Saúde/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Serviço Hospitalar de Cardiologia/organização & administração , Atenção à Saúde/organização & administração , Alemanha , Fidelidade a Diretrizes/normas , Pessoal de Saúde/normas , Humanos , Avaliação de Processos e Resultados em Cuidados de Saúde/organização & administração , Segurança do Paciente/normas , Guias de Prática Clínica como Assunto/normas , Garantia da Qualidade dos Cuidados de Saúde/organização & administração , Resultado do Tratamento
8.
Herz ; 38(1): 48-56, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22407425

RESUMO

OBJECTIVE: We performed a meta-analysis of randomized controlled trials to compare coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI) for the treatment of de novo unprotected left main disease. BACKGROUND: Although CABG is accepted to be standard of care for revascularization of unprotected left main stenosis, PCI is increasingly being used as an alternative primary approach. METHODS: We searched for randomized, controlled trials comparing CABG and PCI for the treatment of unprotected left main disease. Major adverse cardiac and cerebrovascular events (all-cause death, myocardial infarction, stroke, and repeat revascularization) were analyzed. RESULTS: The search strategy identified 4 randomized controlled trials enrolling a total of 1,611 patients. Follow-up ranged between 1 and 2 years. There were no significant differences in the risk of death or myocardial infarction between the two treatment modalities. While the risk of stroke was significantly lower in patients undergoing PCI (risk ratio (RR) 0.26, 95% confidence interval (CI) 0.10-0.69, p = 0.007), the risk of repeat revascularization was higher among patients undergoing PCI (RR 1.94, 95% CI 1.43-2.61, p < 0.001). No relevant statistical heterogeneity across studies could be found. CONCLUSION: In this largest series of randomized patients with unprotected left main stenosis to date, the risk of death and myocardial infarction was comparable between CABG and PCI. However, patients undergoing CABG had a higher risk of stroke, whereas patients undergoing PCI were at a higher risk for repeat revascularization.


Assuntos
Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/mortalidade , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Humanos , Prevalência , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento
9.
Radiologe ; 53(10): 886-95, 2013 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-24129987

RESUMO

Percutaneous transcatheter aortic valve implantation (TAVI) is an established alternative to open heart surgery in patients with severe aortic stenosis (AS) unsuitable for conventional aortic valve replacement due to comorbidities with a high perioperative risk or contraindications. Preprocedural imaging plays a major role for adequate determination of indications and prosthesis selection, prosthesis sizing and therefore for a reduction of periprocedural complications. Besides Doppler echocardiography which is mainly used for grading of the severity of aortic valve stenosis and peri-interventional imaging, cardiac computed tomography (CCT) is the imaging modality of choice. The CCT procedure not only allows for reliably assessment and measuring of the complex 3-dimensional geometry of the aortic root but also for the aorta and the peripheral vessels used as potential access paths.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Radiografia Intervencionista/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Cuidados Pré-Operatórios/métodos , Prognóstico
10.
Minerva Cardioangiol ; 61(1): 33-43, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23381378

RESUMO

Transcatheter aortic valve implantation (TAVI) is a new technology, which is rapidly growing to a routine procedure amenable for patients with symptomatic aortic valve stenosis and higher than average risk for conventional aortic valve surgery. The crucial disadvantage of TAVI remains the not well foreseeable risk of more than trivial degree of paravalvular leakage and a high rate of atrioventricular block and consecutive pacemaker implantation. In addition, current implantation techniques do not allow controlling the rotation of first-generation devices that might be beneficial regarding optimal physiological valve performance, optimal coronary flow and avoidance of placement of covered commissures in front of the coronary ostia. These shortcomings had pushed the development of second-generation self-expandable nitinol-based devices for subcoronary implantation that aim a reduction of paravalvular leak and AV-block by anatomical orientated positioning into the aortic root. This review focuses on the description of three different TAVI concepts, which are presently under early clinical evaluation, or have recently received commercial approval, using the transapical approach.


Assuntos
Valva Aórtica/cirurgia , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Valva Aórtica/anatomia & histologia , Desenho de Equipamento , Humanos
11.
Internist (Berl) ; 54(1): 18, 20-7, 2013 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-23318541

RESUMO

Unlike a few decades ago, today most patients with congenital heart disease reach adulthood after intervention or reparative surgery. As complete correction is generally not possible, a patient population with great complexity and a particular challenge to medical management is rising and a regular follow-up is mandatory. The aim of care is the timely recognition of residual or associated problems. Frequency and intensity of follow-up examinations depend on type and complexity of the lesion. The standard repertoire at follow-up consists of a specific history, clinical examination, ECG, Holter-monitoring, exercise tests, and echocardiography. Depending on the indication, cardio-MRI, CT scan, and sophisticated cardiac catheterization may become necessary. Long-term complications like rhythm disturbances, pulmonary hypertension, or heart failure are frequent, despite optimal care. Acute complications like arrhythmias, infective endocarditis, cerebral events, cerebral abscesses, aortic dissection, pulmonary embolism, and bleeding have to be recognized early and treated appropriately. Additional focus has to be placed on counseling and management of noncardiac disease and surgery, pregnancy and delivery, exercise at work and in private life, driving, and insurance issues. Training and certification of physicians as well as the establishment of specialized centers will help to ensure high quality health care for the affected patient population.


Assuntos
Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/reabilitação , Adulto , Cardiopatias Congênitas/terapia , Humanos , Medição de Risco
12.
Br J Surg ; 99(10): 1331-44, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22961510

RESUMO

BACKGROUND: Acute aortic dissection type A (AADA) is a life-threatening vascular emergency. Clinical presentation ranges from pain related to the acute event, collapse due to aortic rupture or pericardial tamponade, or manifestations of organ or limb ischaemia. The purpose of this review was to clarify important clinical issues of AADA management, with a focus on diagnostic and therapeutic challenges. METHODS: Based on a MEDLINE search the latest literature on this topic was reviewed. Results from the German Registry for Acute Aortic Dissection Type A (GERAADA) are also described. RESULTS: Currently, the perioperative mortality rate of AADA is below 20 per cent, the rate of definitive postoperative neurological impairment approaches 12 per cent and the long-term prognosis after surviving the acute phase of the disease is good. Many pathology- and therapy-associated factors influence the outcome of AADA, including prompt diagnosis with computed tomography and better cerebral protection strategies during aortic arch reconstruction. Endovascular technologies are emerging that may lead to less invasive treatment options. CONCLUSION: AADA is an emergency that can present with a wide variety of clinical scenarios. Advances in the surgical management of this complex disease are improving outcomes.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Doença Aguda , Dissecção Aórtica/diagnóstico , Aneurisma Aórtico/diagnóstico , Ruptura Aórtica/prevenção & controle , Isquemia Encefálica/prevenção & controle , Circulação Extracorpórea/métodos , Humanos , Hipotermia Induzida/métodos , Assistência Perioperatória/métodos , Prognóstico
13.
Thorac Cardiovasc Surg ; 60(5): 319-25, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22859310

RESUMO

Background The increasing prevalence of severe aortic valve defects correlates with the increase of life expectancy. For decades, surgical aortic valve replacement (AVR), under the use of extracorporeal circulation, has been the gold standard for treatment of severe aortic valve diseases. In Germany ~12,000 patients receive isolated aortic valve surgery per year. For some time, percutaneous balloon valvuloplasty has been used as a palliative therapeutic option for very few patients. Currently, alternatives for the established surgical procedures such as transcatheter aortic valve implantation (TAVI) have become available, but there are only limited data from randomized studies or low-volume registries concerning long-time outcome. In Germany, the implementation of this new technology into hospital care increased rapidly in the past few years. Therefore, the German Aortic Valve Registry (GARY) was founded in July 2010 including all available therapeutic options and providing data from a large quantity of patients.Methods The GARY is assembled as a complete survey for all invasive therapies in patients with relevant aortic valve diseases. It evaluates the new therapeutic options and compares them to surgical AVR. The model for data acquisition is based on three data sources: source I, the mandatory German database for external performance measurement; source II, a specific registry dataset; and source III, a follow-up data sheet (generated by phone interview). Various procedures will be compared concerning observed complications, mortality, and quality of life up to 5 years after the initial procedure. Furthermore, the registry will enable a compilation of evidence-based indication criteria and, in addition, also a comparison of all approved operative procedures, such as Ross or David procedures, and the use of different mechanical or biological aortic valve prostheses.Results Since the launch of data acquisition in July 2010, almost all institutions performing aortic valve procedures in Germany joined the registry. By now, 91 sites which perform TAVI in Germany participate and more than 15,000 datasets are already in the registry.Conclusion The implementation of new or innovative medical therapies needs supervision under the conditions of a well-structured scientific project. Up to now relevant data for implementation of TAVI and long-term results are missing. In contrast to randomized controlled trials, GARY is a prospective, controlled, 5-year observational multicenter registry, and a real world investigation with only one exclusion criterion, the absence of patients' written consent.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Sistema de Registros , Idoso , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/psicologia , Seguimentos , Alemanha/epidemiologia , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Fatores de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Resultado do Tratamento , Adulto Jovem
14.
Eur J Echocardiogr ; 12(6): 445-53, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21546375

RESUMO

AIMS: We sought to investigate the additional value of real-time three-dimensional transoesophageal echocardiography (RT 3D TOE)-guided sizing for predicting annuloplasty ring size during mitral valve repair. METHODS AND RESULTS: In 53 patients undergoing elective mitral valve repair, an RT 3D TOE was performed pre- and post-operatively. The digitally stored loops were imported into a software for mitral valve assessment. The annuloplasty ring size was predicted by superimposing computer-aided design (CAD) models of annuloplasty rings onto Live 3D zoom loops, measurement of the intercommissural distance, or the height of the anterior mitral leaflet. The surgeon implanted the annuloplasty ring according to the usual surgical technique and was blinded to the echocardiographic measurement results. Pre-operative correlation between the selected ring size with mitral valve assessment and the actual implanted annuloplasty ring size was 0.91. The correlation for measurement of the intercommissural distance was 0.55 and for measurement of the height of the anterior mitral leaflet 0.75. The post-operative correlation with the actual implanted ring size was 0.96 for mitral valve assessment, 0.92 for intercommissural distance, and 0.79 for the anterior mitral leaflet height. CONCLUSION: Superimposition of annuloplasty ring CAD models on the Live 3D zoom loops of the mitral valve using mitral valve assessment is superior to two-dimensional measurements of the intercommissural distance or the height of the anterior mitral leaflet in predicting correct annuloplasty ring size.


Assuntos
Ecocardiografia Transesofagiana/instrumentação , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Simulação por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/instrumentação , Insuficiência da Valva Mitral/patologia , Insuficiência da Valva Mitral/cirurgia , Modelos Teóricos , Estatística como Assunto
15.
Thorac Cardiovasc Surg ; 59(4): 250-2, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21409751

RESUMO

UNLABELLED: We report a case in which implantation of a rigid tricuspid annuloplasty ring resulted in an aorto-atrial fistula. In addition the patient had a series of complications which had occurred in the perioperative management of the initial operation, characterized by reoperation for mitral and tricuspidal ring dehiscence, and two reopenings for bleeding as well as postoperative sepsis. The attempt to close the fistula on the arrested heart failed. On presentation to our hospital the patient was in decompensated heart failure (NYHA class IV, ascites and pulmonary edema). Our surgical approach (fifth resternotomy) consisted of mitral valve replacement under cardioplegic arrest and re-tricuspid valve repair and closure of the AV fistula on the beating heart. Postoperatively, the patient was extubated on postoperative day one and discharged on postoperative day 41 in NYHA class II. CONCLUSION: Performing a right heart procedure on the beating heart allowed proper identification of the fistula and easy closure.


Assuntos
Doenças da Aorta/cirurgia , Anuloplastia da Valva Cardíaca/efeitos adversos , Cardiopatias/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Tricúspide/cirurgia , Fístula Vascular/cirurgia , Idoso , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/etiologia , Anuloplastia da Valva Cardíaca/instrumentação , Ponte Cardiopulmonar , Remoção de Dispositivo , Ecocardiografia Transesofagiana , Feminino , Parada Cardíaca Induzida , Átrios do Coração/cirurgia , Cardiopatias/diagnóstico por imagem , Cardiopatias/etiologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Doença Iatrogênica , Valva Mitral/cirurgia , Desenho de Prótese , Reoperação , Esternotomia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Fístula Vascular/diagnóstico por imagem , Fístula Vascular/etiologia
16.
Thorac Cardiovasc Surg ; 59(8): 500-3, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21442586

RESUMO

We report a case of delayed onset Takotsubo cardiomyopathy (TC) in a 69-year-old woman, associated with minor stressors, two weeks after mitral valve replacement. After suffering several minor complications she had fully recovered and her discharge was planned. On the 14th postoperative day she had to be resuscitated due to cardiogenic shock. TC was diagnosed based on reduced ventricular function with apical ballooning and normal coronaries. Treatment with catecholamines and intra-aortic balloon pump led to full recovery. She continues to do well two years after surgery. TC should be considered as a potential cause of delayed ventricular dysfunction in postcardiac surgery patients.


Assuntos
Catecolaminas/uso terapêutico , Implante de Prótese de Valva Cardíaca/efeitos adversos , Balão Intra-Aórtico , Insuficiência da Valva Mitral/cirurgia , Cardiomiopatia de Takotsubo/etiologia , Cardiomiopatia de Takotsubo/terapia , Idoso , Feminino , Humanos , Balão Intra-Aórtico/métodos , Cardiomiopatia de Takotsubo/tratamento farmacológico , Cardiomiopatia de Takotsubo/cirurgia , Resultado do Tratamento
17.
Thorac Cardiovasc Surg ; 59(8): 503-6, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21509721

RESUMO

In recent years, catheter-based aortic valve interventions have become established procedures for the treatment of high-risk and advanced age patients with aortic valve pathologies. One of the limitations of the widespread applicability of this procedure is the annulus size. Until recently, no prosthesis was available to treat patients with a large annulus. We report on a patient with high-grade aortic stenosis (AS) and a 27-mm annulus, who underwent transapical implantation (TAP) of an Edwards SAPIEN® 29-mm prosthesis (Edwards LifeScience, Irvine, CA, USA). Due to insufficient dilation of his heavily calcified, functionally bicuspid aortic valve leaflets during balloon aortic valvuloplasty (BAV), the TAP prosthesis did not anchor adequately. This was determined during follow-up as he developed progressive aortic insufficiency and orthopnea, and an echocardiography revealed that the valve had been displaced into the LVOT. A conventional aortic valve replacement and ascending aorta replacement were performed, at which time the TAP prosthesis was removed. The patient recovered uneventfully, and was discharged with a well-functioning aortic bioprosthetic valve and in good general condition.


Assuntos
Aorta/cirurgia , Aneurisma Aórtico/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/etiologia , Dispneia/etiologia , Seguimentos , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Reoperação , Resultado do Tratamento
18.
Thorac Cardiovasc Surg ; 59(2): 78-84, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21384303

RESUMO

Our study aimed to elucidate whether bone marrow stem cell (BMC) treatment might result in a cellular response in cardiomyocytes IN VITRO. Subconfluent neonatal rat cardiomyocyte cultures were cocultured for three days with Vybrant CM-DiI labeled BMC from human sternal bone marrow and underwent immunohistological staining for the proto-oncogene c-Myc and the cell cycle proteins CDK2, CDK4 and ATF-3. ß-adrenoceptor density was analyzed using [125I]-iodocyanopindolol (ICYP) histoautoradiography. Quantitative analysis of immunohistochemical images revealed significantly increased expression and upregulation of c-Myc, and its downstream targets ATF-3, CDK2 and CDK4 in neighboring cardiomyocytes to BMC, depending on their distance to the BMC compared to cardiomyocytes far from the BMC. Histoautoradiography revealed a significantly higher ß-adrenoceptor density in cardiomyocytes in the immediate vicinity to the BMC. With increasing distance to the BMC, ß-adrenoceptor density in cardiomyocytes declined. Thus, a small number of BMC can affect a larger number of cardiomyocytes by activating an intracellular signaling cascade and enhancing ß-adrenoceptor density.


Assuntos
Células da Medula Óssea/metabolismo , Comunicação Celular , Miócitos Cardíacos/metabolismo , Células-Tronco/metabolismo , Fator 3 Ativador da Transcrição/metabolismo , Adulto , Idoso , Animais , Animais Recém-Nascidos , Autorradiografia , Células Cultivadas , Técnicas de Cocultura , Quinase 2 Dependente de Ciclina/metabolismo , Quinase 4 Dependente de Ciclina/metabolismo , Feminino , Humanos , Imuno-Histoquímica , Masculino , Microscopia de Fluorescência , Pessoa de Meia-Idade , Proto-Oncogene Mas , Proteínas Proto-Oncogênicas c-myc/metabolismo , Ratos , Ratos Sprague-Dawley , Receptores Adrenérgicos beta/metabolismo , Transdução de Sinais , Regulação para Cima
19.
Pharmacology ; 88(3-4): 167-73, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21952163

RESUMO

BACKGROUND/AIMS: Mitochondrial permeability transition pore (MPTP) opening appears to play a key role in myocardial cell survival after ischemia-reperfusion injury and can be inhibited by cyclosporin A (CsA). We investigated whether low-dose CsA added to histidine-tryptophan-ketoglutarate (HTK) cardioplegia solution could improve myocardial protection during longer periods of global myocardial ischemia as encountered during cardiac surgery. METHODS: Rabbit hearts perfused on a Langendorff apparatus were arrested with cold HTK solution containing 1 µmol/l CsA. After 90 min of ischemia, the hearts were reperfused and pmax, max dp/dt, min dp/dt, myocardial stiffness, pO(2), coronary flow and heart rate recorded. Tissue ATP and malondialdehyde (MDA) were measured to assess cell energy content and oxidative stress, respectively. RESULTS: CsA-treated hearts recovered pmax (p = 0.026), max dp/dt (p = 0.028) and min dp/dt (p = 0.025) more quickly and to a greater extent than non-treated hearts. They required markedly less oxygen (p = 0.041) in the first 10 min of reperfusion. Hearts treated with CsA produced 44% less MDA (1.09 vs. 1.93, p = 0.008), while ATP levels were unchanged. CONCLUSIONS: HTK cardioplegia solution containing CsA at a dose well below that expected to cause systemic immunosuppressive effects leads to a significant and timelier recovery of myocardial contractility, while consuming less oxygen.


Assuntos
Soluções Cardioplégicas/farmacologia , Cardiotônicos/farmacologia , Ciclosporina/farmacologia , Imunossupressores/farmacologia , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Trifosfato de Adenosina/metabolismo , Animais , Glucose/farmacologia , Coração/efeitos dos fármacos , Coração/fisiopatologia , Masculino , Malondialdeído/metabolismo , Manitol/farmacologia , Oxigênio/metabolismo , Cloreto de Potássio/farmacologia , Procaína/farmacologia , Coelhos , Pressão Ventricular/efeitos dos fármacos
20.
Thorac Cardiovasc Surg ; 58(7): 431-3, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20922629

RESUMO

Pacemaker implantation using endocardial leads can give rise to thrombotic venous occlusion. We report the case of a 23-year-old male with transposition of the great arteries, who had previously undergone a Senning repair at the age of one year. A sick sinus syndrome required pacemaker implantation with subsequent multiple lead revisions. Following the implantation of the last lead, the patient developed complete occlusion of the inferior vena cava (IVC) with stenosis of the superior vena cava (SVC) with pacemaker leads in both lesions. Liver failure, ascites and esophageal varices developed. Thrombolytic treatment was ineffective; finally the patient was listed for liver transplantation. We explanted the lead embedding the thrombosis, together with some lead remnants. The stenosis of the SVC and the occlusion of the IVC were dilatated and stabilized with four stents. Over a follow-up period of 4 months, NYHA class improved from NYHA III to NYHA I-II, the hepatic function showed complete remission, and a liver transplantation was not necessary.


Assuntos
Falência Hepática/etiologia , Marca-Passo Artificial/efeitos adversos , Síndrome do Nó Sinusal/terapia , Síndrome da Veia Cava Superior/etiologia , Veia Cava Inferior , Trombose Venosa/etiologia , Cateterismo , Constrição Patológica , Remoção de Dispositivo , Desenho de Equipamento , Humanos , Falência Hepática/diagnóstico por imagem , Falência Hepática/terapia , Masculino , Flebografia , Stents , Síndrome da Veia Cava Superior/diagnóstico por imagem , Síndrome da Veia Cava Superior/terapia , Resultado do Tratamento , Veia Cava Inferior/diagnóstico por imagem , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/terapia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA