Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Respir J ; 53(5)2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30846467

RESUMO

Adherence to inhaled maintenance therapy in severe asthma is rarely adequately assessed, and its influence on trial outcomes is unknown. We systematically determined how adherence to maintenance therapy is assessed in clinical trials of "add-on" therapy for severe asthma. We model the improvement in trial power that could be achieved by accurately assessing adherence.A systematic search of six major databases identified randomised trials of add-on therapy for severe asthma. The relationship between measuring adherence and study outcomes was assessed. An estimate of potential improvements in statistical power and sample size was derived using digitally recorded adherence trial data.87 randomised controlled trials enrolling 22 173 participants were included. Adherence assessment was not reported in 67 trials (n=13 931, 63%). Studies that reported adherence used a range of self-report and subjective methods. None of the studies employed an objective assessment of adherence. Studies that reported adherence had a significantly reduced pooled variance in forced expiratory volume in 1 s (FEV1) compared to those that did not assess adherence: s2=0.144 L2 versus s2=0.168 L2, p<0.0001. Power to detect clinically relevant changes in FEV1 was significantly higher in trials that reported adherence assessment (mean power achieved 59% versus 49%). Modelling suggests that up to 50% of variance in FEV1 outcomes is attributable to undetected variations in adherence. Controlling for such variations could potentially halve the required sample size.Few trials of add-on therapy monitor adherence to maintenance inhaled therapy, resulting in a greater variance in trial outcomes and inadequate power for determining efficacy.


Assuntos
Antiasmáticos/administração & dosagem , Asma/tratamento farmacológico , Adesão à Medicação , Administração por Inalação , Corticosteroides/administração & dosagem , Asma/economia , Progressão da Doença , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Testes de Função Respiratória
2.
Eur Respir J ; 51(1)2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29301919

RESUMO

In severe asthma, poor control could reflect issues of medication adherence or inhaler technique, or that the condition is refractory. This study aimed to determine if an intervention with (bio)feedback on the features of inhaler use would identify refractory asthma and enhance inhaler technique and adherence.Patients with severe uncontrolled asthma were subjected to a stratified-by-site random block design. The intensive education group received repeated training in inhaler use, adherence and disease management. The intervention group received the same intervention, enhanced by (bio)feedback-guided training. The primary outcome was rate of actual inhaler adherence. Secondary outcomes included a pre-defined assessment of clinical outcome. Outcome assessors were blinded to group allocation. Data were analysed on an intention-to-treat and per-protocol basis.The mean rate of adherence during the third month in the (bio)feedback group (n=111) was higher than that in the enhanced education group (intention-to-treat, n=107; 73% versus 63%; 95% CI 2.8%-17.6%; p=0.02). By the end of the study, asthma was either stable or improved in 54 patients (38%); uncontrolled, but poorly adherent in 52 (35%); and uncontrolled, but adherent in 40 (27%).Repeated feedback significantly improved inhaler adherence. After a programme of adherence and inhaler technique assessment, only 40 patients (27%) were refractory and adherent, and might therefore need add-on therapy.


Assuntos
Asma/tratamento farmacológico , Asma/terapia , Biorretroalimentação Psicológica , Adesão à Medicação , Nebulizadores e Vaporizadores , Administração por Inalação , Adulto , Idoso , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pico do Fluxo Expiratório , Estudos Prospectivos
3.
Am J Respir Crit Care Med ; 195(10): 1333-1343, 2017 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-27409253

RESUMO

RATIONALE: Objective adherence to inhaled therapy by patients with chronic obstructive pulmonary disease (COPD) has not been reported. OBJECTIVES: To objectively quantify adherence to preventer Diskus inhaler therapy by patients with COPD with an electronic audio recording device (INCA). METHODS: This was a prospective observational study. On discharge from hospital patients were given a salmeterol/fluticasone inhaler with an INCA device attached. Analysis of this audio quantified the frequency and proficiency of inhaler use. MEASUREMENTS AND MAIN RESULTS: Patients with COPD (n = 244) were recruited. The mean age was 71 years, mean FEV1 was 1.3 L, and 59% had evidence of mild/moderate cognitive impairment. By combining time of use, interval between doses, and critical technique errors, thus incorporating both intentional and unintentional nonadherence, a measure "actual adherence" was calculated. Mean actual adherence was 22.6% of that expected if the doses were taken correctly and on time. Six percent had an actual adherence greater than 80%. Hierarchical clustering found three equally sized well-separated clusters corresponding to distinct patterns. Cluster 1 (34%) had low inhaler use and high error rates. Cluster 2 (25%) had high inhaler use and high error rates. Cluster 3 (36%) had overall good adherence. Poor lung function and comorbidities were predictive of poor technique, whereas age and cognition with poor lung function distinguished those with poor adherence and frequent errors in technique. CONCLUSIONS: These data may inform clinicians in understanding why a prescribed inhaler is not effective and to devise strategies to promote adherence in COPD.


Assuntos
Broncodilatadores/administração & dosagem , Nebulizadores e Vaporizadores , Cooperação do Paciente/estatística & dados numéricos , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Administração por Inalação , Idoso , Broncodilatadores/uso terapêutico , Combinação de Medicamentos , Feminino , Fluticasona/administração & dosagem , Humanos , Masculino , Estudos Prospectivos , Xinafoato de Salmeterol/administração & dosagem , Xinafoato de Salmeterol/uso terapêutico
4.
Respirology ; 20(5): 749-57, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25872951

RESUMO

BACKGROUND AND OBJECTIVE: Hiatal hernias (HH) are associated with gastro-oesophageal reflux and may contribute to lung disease severity. We aimed to evaluate the prevalence of HH among stable non-cystic fibrosis bronchiectasis (NCFB) patients and determine associations with disease severity. METHODS: A retrospective cross-sectional cohort study of 100 consecutive NCFB patients in our institution was performed. Data were collected on baseline variables, microbiology, lung function and radiology, according to the modified Bhalla score. Disease severity was assessed using the Bronchiectasis Severity Index (BSI) and FACED severity scores. RESULTS: Following expert radiological review, 81 patients were deemed suitable for study inclusion (mean age (SD) 62.6 (12.4), females 55 (67.9%), body mass index (BMI) 26.9 (5.7)); 29 (35.8%) were HH positive (HH+). HH+ patients had a trend towards higher BMI (P = 0.07), and a significantly higher proportion had reflux symptoms (HH+ 62.1% vs HH- 28.8%, P < 0.01). The presence of HH+ was associated with cystic bronchiectasis (HH+ 30.1%, HH- 11.5%; P = 0.03), increased number of lobes involved (HH+ 2.62 (1.54), HH- 2.17 (1.42); P = 0.03), increased extent of bronchiectasis, (HH+ 6.2 (4.7), HH- 4.5 (3.1); P = 0.04), decreased parenchymal attenuation (HH+ 1.0 (1.8), HH- 0.2 (0.5); P = 0.03) and reduced per cent predicted forced expiratory volume in 1 s (HH+ 75.4% (24.5), HH- 90.4% (25.5); P = 0.02). There was no lobar predilection. HH+ was associated with increased disease severity scores: BSI (HH+ 4.93 (1.65), HH- 3.25 (2.13); P < 0.001) and FACED (HH+ 2.21 (1.52), HH- 1.35 (1.43); P < 0.01). CONCLUSIONS: HH+ was associated with worse disease severity in NCFB patients, characterized by decreased lung function, increased extent and severity of radiological disease, and increased composite disease severity scores.


Assuntos
Bronquiectasia , Hérnia Hiatal , Idoso , Índice de Massa Corporal , Bronquiectasia/diagnóstico , Bronquiectasia/epidemiologia , Bronquiectasia/fisiopatologia , Estudos de Coortes , Comorbidade , Estudos Transversais , Feminino , Refluxo Gastroesofágico/diagnóstico , Refluxo Gastroesofágico/fisiopatologia , Hérnia Hiatal/diagnóstico , Hérnia Hiatal/epidemiologia , Hérnia Hiatal/fisiopatologia , Humanos , Irlanda/epidemiologia , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Prevalência , Radiografia , Testes de Função Respiratória/métodos , Estudos Retrospectivos , Índice de Gravidade de Doença
6.
Lancet Respir Med ; 11(7): 591-601, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36963417

RESUMO

BACKGROUND: The clinical value of using digital tools to assess adherence and lung function in uncontrolled asthma is not known. We aimed to compare treatment decisions guided by digitally acquired data on adherence, inhaler technique, and peak flow with existing methods. METHODS: A 32-week prospective, multicentre, single-blinded, parallel, randomly controlled trial was done in ten severe asthma clinics across Ireland, Northern Ireland, and England. Participants were 18 years or older, had uncontrolled asthma, asthma control test (ACT) score of 19 or less, despite treatment with high-dose inhaled corticosteroids, and had at least one severe exacerbation in the past year despite high-dose inhaled corticosteroids. Patients were randomly assigned in a 1:1 ratio to the active group or the control group, by means of a computer-generated randomisation sequence of permuted blocks of varying sizes (2, 4, and 6) stratified by fractional exhaled nitric oxide (FeNO) concentration and recruitment site. In the control group, participants were masked to their adherence and errors in inhaler technique data. A statistician masked to study allocation did the statistical analysis. After a 1-week run-in period, both groups attended three nurse-led education visits over 8 weeks (day 7, week 4, and week 8) and three physician-led treatment adjustment visits at weeks 8, 20, and 32. In the active group, treatment adjustments during the physician visits were informed by digital data on inhaler adherence, twice daily digital peak expiratory flow (ePEF), patient-reported asthma control, and exacerbation history. Treatment was adjusted in the control group on the basis of pharmacy refill rates (a measure of adherence), asthma control by ACT questionnaire, and history of exacerbations and visual management of inhaler technique. Both groups used a digitally enabled Inhaler Compliance Assessment (INCA) and PEF. The primary outcomes were asthma medication burden measured as proportion of patients who required a net increase in treatment at the end of 32 weeks and adherence rate measured in the last 12 weeks by area under the curve in the intention-to-treat population. The safety analyses included all patients who consented for the trial. The trial is registered with ClinicalTrials.gov, NCT02307669 and is complete. FINDINGS: Between Oct 25, 2015, and Jan 26, 2020, of 425 patients assessed for eligibility, 220 consented to participate in the study, 213 were randomly assigned (n=108 in the active group; n=105 in the control group) and 200 completed the study (n=102 in the active group; n=98 in the control group). In the intention-to-treat analysis at week 32, 14 (14%) active and 31 (32%) control patients had a net increase in treatment compared with baseline (odds ratio [OR] 0·31 [95% CI 0·15-0·64], p=0·0015) and 11 (11%) active and 21 (21%) controls required add-on biological therapy (0·42 [0·19-0·95], p=0·038) adjusted for study site, age, sex, and baseline FeNO. Three (16%) of 19 active and 11 (44%) of 25 control patients increased their medication from fluticasone propionate 500 µg daily to 1000 µg daily (500 µg twice a day; adjusted OR 0·23 [0·06-0·87], p=0·026). 26 (31%) of 83 active and 13 (18%) of 73 controls reduced their medication from fluticasone propionate 1000 µg once daily to 500 µg once daily (adjusted OR 2·43 [1·13-5·20], p=0·022. Week 20-32 actual mean adherence was 64·9% (SD 23·5) in the active group and 55·5% (26·8) in the control group (between-group difference 11·1% [95% CI 4·4-17·9], p=0·0012). A total of 29 serious adverse events were recorded (16 [55%] in the active group, and 13 [45%] in the control group), 11 of which were confirmed as respiratory. None of the adverse events reported were causally linked to the study intervention, to the use of salmeterol-fluticasone inhalers, or the use of the digital PEF or INCA. INTERPRETATION: Evidence-based care informed by digital data led to a modest improvement in medication adherence and a significantly lower treatment burden. FUNDING: Health Research Board of Ireland, Medical Research Council, INTEREG Europe, and an investigator-initiated project grant from GlaxoSmithKline.


Assuntos
Antiasmáticos , Asma , Humanos , Broncodilatadores/uso terapêutico , Estudos Prospectivos , Resultado do Tratamento , Método Duplo-Cego , Asma/tratamento farmacológico , Fluticasona/uso terapêutico , Nebulizadores e Vaporizadores , Corticosteroides/uso terapêutico , Adesão à Medicação , Pulmão , Antiasmáticos/uso terapêutico
7.
J Allergy Clin Immunol Pract ; 9(7): 2732-2741.e1, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33577946

RESUMO

BACKGROUND: Goal-orientated health care accounts for patient preferences and values, not just physician treatment aims. The Global Initiative for Asthma (GINA) management strategy states that clinicians should elicit patients' own treatment goals as a central part of care. Despite this recommendation, data on patients' treatment goals are sparse among patients with severe asthma. OBJECTIVE: The objective of this study is to investigate the relationship between rates of treatment adherence and goal achievement, and patient-selected goals. METHODS: Thematic analysis was used to characterize patient-selected goals. Previously undescribed goal categories in asthma were identified, quantified, and related to clinical characteristics. Goal achievement was aligned with objectively measured treatment adherence. RESULTS: Three categories of patients-selected goals were identified from 2 randomized control trials: disease-specific (n = 98 [51%] and n = 92 [54%], respectively), function-related (n = 90 [48%] and n = 61 [36%]), and knowledge (n = 1 [1%] and n = 17 [10%]). Only 53% of goals aligned with clinician treatment goals. Patients who chose disease-specific goals were more likely to achieve both control and their specified goal (n = 98 [45%], odds ratio: 1.789, confidence interval: 1.066-3.001). Male participants are more likely to focus on disease-specific goals. Patients who achieved their goals were more likely to be T2-high, have an elevated fractional exhaled nitric oxide (FeNO) at their first visit, and have a lower FeNO value at their final visit. Interestingly, adherence rates decline significantly for those who achieve their goals. CONCLUSION: Almost half of patient-selected goals do not align with GINA clinical asthma management goals. Participants who chose goals that do align with clinicians were more likely to achieve them.


Assuntos
Asma , Objetivos , Asma/tratamento farmacológico , Testes Respiratórios , Expiração , Humanos , Masculino , Óxido Nítrico
8.
J Allergy Clin Immunol Pract ; 8(2): 635-644, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31568927

RESUMO

BACKGROUND: Guidelines recommend that patients treated with inhalers receive adherence counseling and device training. Digital technologies that assess both inhaler adherence and technique have been developed. Using these technologies community pharmacists, who have regular contact with patients, are well placed to deliver personalized inhaler education. OBJECTIVE: To determine the impact of a pharmacist intervention, informed by digital technology, on inhaler technique and adherence of patients with asthma in the community. METHODS: A cluster randomized, parallel-group, multisite pharmacy study was conducted over 6 months. All study groups had an electronic device (inhaler compliance assessment device) attached to their maintenance inhaler. A biofeedback group received personalized inhaler training informed by data recorded by the device. The demonstration group received inhaler training, by physical demonstration with a placebo inhaler. The control group received usual care. The primary outcome was inhaler adherence, which was classified as "actual adherence" and expressed as the proportion of expected drug accumulation if adherence and technique had been perfect. Secondary outcomes were quality-of-life scores as measured by the St George's Respiratory Questionnaire, symptoms, and exacerbations. RESULTS: A total of 152 participants (n = 74 biofeedback, n = 56 demonstration, and n = 22 control) were recruited. Asthma was the predominant condition among participants (n = 83), with chronic obstructive pulmonary disease (n = 55) and asthma/chronic obstructive pulmonary disease overlap also reported (n = 8). In intention-to-treat analysis, adherence in the biofeedback group during month 2 was 62%, 18% higher (95% CI, 6 to 30) than that in the demonstration group (P = .004) and 24% higher (95% CI, 9 to 40) than that in the control group (P = .003). During month 6, adherence was 14% higher (95% CI, -1 to 30; P = .07) in the biofeedback group than in the demonstration group and 31% higher (95% CI, 13 to 48; P = .001) than in the control group. At the end of the study, the biofeedback group had a sustained fall in St George's Respiratory Questionnaire from baseline, -6.1 (95% CI, -9 to -0.4; P = .04) and had significantly improved daily respiratory symptoms. CONCLUSIONS: Community pharmacist-delivered inhaler training informed by a digital technology improved adherence and health status.


Assuntos
Farmacêuticos , Doença Pulmonar Obstrutiva Crônica , Administração por Inalação , Biorretroalimentação Psicológica , Humanos , Adesão à Medicação , Nebulizadores e Vaporizadores , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Qualidade de Vida
9.
NPJ Prim Care Respir Med ; 28(1): 24, 2018 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-29950601

RESUMO

Four inhaler adherence clusters have been identified using the INCA audio device in COPD patients: (1) regular use/good technique, (2) regular use/frequent technique errors, (3) irregular use/good technique, and (4) irregular use/frequent technique errors. Their relationship with healthcare utilization and mortality was established, but the cost-effectiveness of adherence-enhancing interventions is unknown. In this exploratory study, we aimed to estimate the potential cost-effectiveness of reaching optimal adherence in the three suboptimal adherence clusters, i.e., a theoretical shift of clusters 2, 3, and 4 to cluster 1. Cost-effectiveness was estimated over a 5-year time horizon using the Irish healthcare payer perspective. We used a previously developed COPD health-economic model that was updated with INCA trial data and Irish national economic and epidemiological data. For each cluster, interventions would result in additional quality-adjusted life years gained at reasonable investment. Cost-effectiveness was most favorable in cluster 3, with possible cost savings of €845/annum/person.


Assuntos
Análise Custo-Benefício , Adesão à Medicação/estatística & dados numéricos , Nebulizadores e Vaporizadores/economia , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Doença Pulmonar Obstrutiva Crônica/economia , Seguimentos , Humanos
10.
J Aerosol Med Pulm Drug Deliv ; 30(4): 247-255, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28277810

RESUMO

BACKGROUND: Researchers, using checklists, have identified that 30%-90% of patients make errors in inhaler use. It is not certain whether these errors affect the delivery of medication. We have developed an electronic monitor (INCA™) that records audio each time an inhaler is used, providing objective information on inhaler technique. The aim of this study was to assess the effect that correctly identified inhaler errors, with the INCA device, have on drug delivery. METHODS: This was a prospective study of healthy volunteers using a salbutamol Diskus™. The inclusion criteria allowed for the recruitment of healthy participants who were nonfrequent users of Salbutamol. Each participant was assigned to one control "phase" first and two/three subsequent error "phases." Each phase consisted of six doses of the drug taken 6 hours apart, and the participants' blood was drawn before and 25 minutes after doses one and six. This allowed us to sample their trough and peak serum salbutamol levels. RESULTS: Fourteen healthy volunteers were studied. The inhaler technique errors simulated in this study included exhaling into the device after drug priming but before inhalation, low inspiratory flow, multiple inhalations, low breath hold, missed doses, and wrong inhaler position. Only the exhalation error, low inspiratory flow, and missed doses led to a significant reduction in serum salbutamol levels. After six doses of the exhalation error, there was a 62% reduction in peak salbutamol levels. Low inspiratory flow led to a 52% reduction in peak salbutamol levels and a 78% reduction in trough levels. Missed doses led to a 37% reduction in trough salbutamol levels. CONCLUSIONS: These findings confirm that technique errors affect drug delivery. Furthermore, we were able to identify that the most critical technique errors with the Diskus inhaler are exhalation into the device before inhalation, poor inspiratory flow, and missing doses.


Assuntos
Albuterol/administração & dosagem , Sistemas de Liberação de Medicamentos , Inaladores de Pó Seco , Autoadministração/normas , Administração por Inalação , Adulto , Albuterol/farmacocinética , Broncodilatadores/administração & dosagem , Broncodilatadores/farmacocinética , Desenho de Equipamento , Expiração , Feminino , Humanos , Masculino , Estudos Prospectivos , Adulto Jovem
11.
BMJ Open ; 7(6): e015367, 2017 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-28619778

RESUMO

INTRODUCTION: Many patients with asthma remain poorly controlled despite the use of inhaled corticosteroids and long-acting beta agonists. Poor control may arise from inadequate adherence, incorrect inhaler technique or because the condition is refractory. Without having an objective assessment of adherence, clinicians may inadvertently add extra medication instead of addressing adherence. This study aims to assess if incorporating objectively recorded adherence from the Inhaler Compliance Assessment (INCA) device and lung function into clinical decision making provides more cost-effective prescribing and improves outcomes. METHODS AND ANALYSIS: This prospective, randomised, multicentre study will compare the impact of using information on adherence to influence asthma treatment. Patients with severe uncontrolled asthma will be included. Data on adherence, inhaler technique and electronically recorded peak expiratory flow rate will be used to promote adherence and guide a clinical decision protocol to guide management in the active group. The control group will receive standard inhaler and adherence education. Medications will be adjusted using a protocol based on Global Initiativefor Asthma (GINA) recommendations. The primary outcome is the between-group difference in the proportion of patients who have refractory disease and are prescribed appropriate medications at the end of 32 weeks. A co-primary outcome is the difference between groups in the rate of adherence to salmeterol/fluticasone inhaler over the last 12 weeks. Secondary outcomes include changes in symptoms, lung function, type-2 cytokine biomarkers and clinical outcomes between both groups. Cost-effectiveness and cost-utility analyses of the INCA device intervention will be performed. The economic impact of a national implementation of the INCA-SUN programme will be evaluated. ETHICS AND DISSEMINATION: The results of the study will be published as a manuscript in peer-reviewed journals. The study has been approved by the ethics committees in the five participating hospitals. TRIAL REGISTRATION: NCT02307669; Pre-results.


Assuntos
Corticosteroides/uso terapêutico , Asma/tratamento farmacológico , Broncodilatadores/uso terapêutico , Tomada de Decisão Clínica , Monitoramento de Medicamentos , Adesão à Medicação/estatística & dados numéricos , Nebulizadores e Vaporizadores , Administração por Inalação , Adulto , Asma/epidemiologia , Asma/fisiopatologia , Progressão da Doença , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Irlanda/epidemiologia , Masculino , Adesão à Medicação/psicologia , Educação de Pacientes como Assunto , Pico do Fluxo Expiratório/efeitos dos fármacos , Pico do Fluxo Expiratório/fisiologia , Estudos Prospectivos , Resultado do Tratamento
12.
Ann Am Thorac Soc ; 13(11): 1894-1903, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27467125

RESUMO

RATIONALE: Currently, studies on adherence to inhaled medications report average adherence over time. This measure does not account for variations in the interval between doses, nor for errors in inhaler use. OBJECTIVES: To investigate whether adherence calculated as a single area under the (concentration-time) curve (AUC) measure, incorporating the interval between doses and inhaler technique, was more reflective of patient outcomes than were current methods of assessing adherence. METHODS: We attached a digital audio device (INhaler Compliance Assessment) to a dry powder inhaler. This recorded when the inhaler was used, and analysis of the audio data indicated if the inhaler had been used correctly. These aspects of inhaler use were combined to calculate adherence over time, as an AUC measure. Over a 3-month period, a cohort of patients with asthma was studied. Adherence to a twice-daily inhaler preventer therapy using this device and clinical measures were assessed. MEASUREMENTS AND MAIN RESULTS: Recordings from 239 patients with severe asthma were analyzed. Average adherence that was based on the dose counter was 84.4%, whereas the ratio of expected to observed accumulated AUC, actual adherence, was 61.8% (P < 0.01). Of all the adherence measures, only adherence calculated as AUC reflected changes in asthma quality of life, ß-agonist reliever use, and peak expiratory flow over the 3 months (P < 0.05 compared with other measures of adherence). CONCLUSIONS: Adherence that incorporates the interval between doses and inhaler technique, and calculated as AUC, is more reflective of changes in quality of life and lung function than are the currently used measures of adherence. Clinical trial registered with www.clinicaltrials.gov (NCT 01529697).


Assuntos
Asma/tratamento farmacológico , Broncodilatadores/uso terapêutico , Adesão à Medicação/estatística & dados numéricos , Administração por Inalação , Adulto , Idoso , Área Sob a Curva , Feminino , Humanos , Irlanda , Masculino , Pessoa de Meia-Idade , Nebulizadores e Vaporizadores/estatística & dados numéricos , Estudos Prospectivos , Qualidade de Vida , Método Simples-Cego , Resultado do Tratamento
13.
BMJ Case Rep ; 20132013 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-24072840

RESUMO

Upper airway obstruction can present with stridor or expiratory or inspiratory wheeze and is commonly misdiagnosed as asthma. As asthma is common, such cases can remain hidden among patients with lower airway obstruction who attend primary care or respiratory clinics. We describe four causes of upper airway obstruction (paradoxical vocal cord movement, subglottic stenosis, retrosternal goitre and double aortic arch) which were misdiagnosed as 'poorly controlled asthma'.


Assuntos
Asma/diagnóstico , Erros de Diagnóstico , Sons Respiratórios/diagnóstico , Adolescente , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA