1.
J Appl Clin Med Phys ; 21(12): 263-271, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33270974

RESUMO

PURPOSE/OBJECTIVES: The purpose of this study is to dually evaluate the effectiveness of PlanIQ in predicting the viability and outcome of dosimetric planning in cases of complex re-irradiation as well as generating an equivalent plan through Pinnacle integration. The study also postulates that a possible strength of PlanIQ lies in mitigating pre-optimization uncertainties tied directly to dose overlap regions where re-irradiation is necessary. METHODS: A retrospective patient selection (n = 20) included a diverse range of re-irradiation cases to be planned using Pinnacle auto-planning with PlanIQ integration. A consistent planning template was developed and applied across all cases. Direct plan comparisons of manual plans against feasibility-produced plans were performed by physician(s) with dosimetry recording relevant proximal OAR and planning timeline data. RESULTS AND DISCUSSION: All re-irradiation cases were successfully predicted to be achievable per PlanIQ analyses with three cases (3/20) necessitating 95% target coverage conditions, previously exhibited in the manually planned counterparts, and determined acceptable under institutional standards. At the same time, PlanIQ consistently produced plans of equal or greater quality to the previously manually planned re-irradiation across all (20/20) trials (P = 0.05). Proximal OAR exhibited similar to slightly improved maximum point doses from feasibility-based planning with the largest advantages gained found within the subset of cranial and spine overlap cases, where improvements upward of 10.9% were observed. Mean doses to proximal tissues were found to be a statistically significant (P < 0.05) 5.0% improvement across the entire study. Documented planning times were markedly less than or equal to the time contributed to manual planning across all cases. CONCLUSION: Initial findings indicate that PlanIQ effectively provides the user clear feasibility feedback capable of facilitating decision-making on whether re-irradiation dose objectives and prescription dose coverage are possible at the onset of treatment planning thus eliminating possible trial and error associated with some manual planning. Introducing model-based prediction tools into planning of complex re-irradiation cases yielded positive outcomes on the final treatment plans.


Assuntos
Radioterapia de Intensidade Modulada , Reirradiação , Benchmarking , Estudos de Viabilidade , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
2.
Brachytherapy ; 20(2): 353-360, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33187822

RESUMO

PURPOSE: The in vivo dosimetric monitoring in HDR brachytherapy is important for improving patient safety. However, there are very limited options available for clinical application. In this study, we present a new in vivo dose measurement system with a plastic scintillating detector (PSD) for GYN HDR brachytherapy. METHODS: An FDA approved PSD system, called OARtrac (AngioDynamics, Latham, NY), was used with various applicators for in vivo dose measurements for GYN patients. An institutional workflow was established for the clinical implementation of the dosimetric system. Action levels were proposed based on the measurement and system uncertainty for measurement deviations. From October 2018 to September 2019, a total of 75 measurements (48 fractions) were acquired from 14 patients who underwent HDR brachytherapy using either a multichannel cylinder, Venezia applicator, or Syed-Neblett template. The PSDs were placed in predetermined catheters/channels. A planning CT was acquired for treatment planning in Oncentra (Elekta, Version-4.5.2) TPS. The PSDs were contoured on the CT images, and the PSD D90% values were used as the expected doses for comparison with the measured doses. RESULTS: The mean difference from patient measurements was -0.22% ± 5.98%, with 26% being the largest deviation from the expected value (Syed case). Large deviations were observed when detectors were placed in the area where dose rates were less than 1 cGy/s. CONCLUSIONS: The establishment of clinical workflow for the in vivo dosimetry for both the intracavitary and interstitial GYN HDR brachytherapy will potentially improve the safety of the patient treatment.


Assuntos
Braquiterapia , Braquiterapia/métodos , Catéteres , Estudos de Viabilidade , Humanos , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador