Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Clin Oral Implants Res ; 28(2): 171-176, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26864453

RESUMO

OBJECTIVES: The objective of this study was to examine peri-implant mucosal thickness at different sites of peri-implant crevice around 70 implants placed in 35 patients. MATERIAL AND METHODS: The peri-implant mucosal thickness was defined as distance of the peri-implant mucosal margin and the coronal edge of bone/implant contact and measured using the cast models and dental radiography. RESULTS: The overall mean peri-implant mucosal thickness was 3.6 ± 1.4 mm, wherein maxillary anterior implants, maxillary posterior implants and mandibular posterior implants had significantly different dimensions of median thickness of 4.25, 3.75 and 3.0 mm, respectively. Furthermore, the mesial and distal sites of those positioned implants measured unevenness in the thickness especially in the maxillary posterior region with statistical significance. CONCLUSION: The proposed methodology to evaluate peri-implant mucosal thickness measured with a big variation from overall 3.6 mm with a big variation from 1.6 to 7.0 mm in healthy volunteers. And significant difference was found in the depth among the three regions and, statistically, dispersion of individual peri-implant mucosal thickness resulted in lack of consistency. Although dental implants have been well developed, predictable and prevailing prosthetics, onset of peri-implantitis might be inevitable in some cases. Therefore, establishment of a standardized dimensional diagnosis of peri-implant tissues followed by pathologic ascertainment could be taken into account for the prevention or curing of peri-implantitis.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Mucosa Bucal/patologia , Peri-Implantite/patologia , Humanos , Estudos Retrospectivos
2.
Implant Dent ; 26(2): 275-283, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28301385

RESUMO

INTRODUCTION: We have recently used highly pure ß-TCP (beta-tricalcium phosphate) as the bone grafting material to avoid highly invasive autogenous bone grafting. We evaluated the osseoconduction potential of highly pure ß-TCP in sinus augmentation surgery treatment. MATERIALS AND METHODS: The study group comprised 13 patients who underwent maxillary sinus floor augmentation with ß-TCP alone. Seven patients underwent sinus augmentation and implant placement simultaneously. Six patients were treated with a staged approach. Six months after surgery, specimens were obtained from 7 patients (for lateral biopsy) and 6 patients (for vertical biopsy). RESULTS: Histological and histomorphometrical analysis showed a mean bone proportion of 30.8% (vertical) and 12.0% (lateral) for new bone formation and good integration of the ß-TCP. New bone formation was lower in the lateral biopsy specimens than in the vertical. CONCLUSION: Highly pure ß-TCP is a safe bone-grafting material with superior osteoconductive properties. Histologic and radiographic examinations indicate that ß-TCP is slowly resorbed, which results in unresorbed graft material remaining even 6 months after the procedure, and that new bone replacement occurs slowly for approximately 1 year.


Assuntos
Processo Alveolar/patologia , Substitutos Ósseos/uso terapêutico , Fosfatos de Cálcio/uso terapêutico , Levantamento do Assoalho do Seio Maxilar/métodos , Idoso , Processo Alveolar/diagnóstico por imagem , Processo Alveolar/efeitos dos fármacos , Regeneração Óssea/efeitos dos fármacos , Substitutos Ósseos/metabolismo , Fosfatos de Cálcio/metabolismo , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
3.
J Prosthodont ; 25(4): 341-8, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26221747

RESUMO

A 47-year-old man underwent surgical resection and reconstruction with a fibula osteocutaneous flap. After the surgery, a surgical obturator was placed and adjusted. After flap healing, a conventional obturator was fabricated with polymethyl methacrylate resin and retained by the anatomical undercuts around the reconstructed fibula bone flap and the posterior part of the defect. As the defect shape changed with time, a second conventional obturator was fabricated and fitted. No further recurrence of myoepithelioma was observed for 2 years, and the patient was satisfied with the obturator during mastication and speech; however, despite having no major complaints, the patient found it difficult to chew on the right side, and the obturator was displaced slightly downward when the mouth was opened wide and shifted when chewing hard and sticky food. Thus, an implant-retained obturator was suggested to provide better retention and stability. Four dental implants were therefore placed into the fibula bone, although one did not osseointegrate because either primary stability was insufficient or overload was affected in the nonloaded implant environment and was replaced. After fitting custom abutments with a magnet, an implant-retained obturator was placed, and the patient was satisfied with the outcome. During 3 years of follow-up, no issues were noted with the implant bodies, abutments, obturator, or reconstructed site. The conventional obturator was displaced slightly downward when the patient opened his mouth wide, and it shifted when chewing hard and sticky food because there was limited fibula bone at the reconstruction site and more available posteriorly. For better retention and stability, the implant-retained obturator was fabricated with a custom abutment and magnetic retention. The patient was satisfied with the results, as improved implant retention increased the stability of the prosthesis. This clinical report describes the rehabilitation of a bilateral maxillectomy patient with a free fibula osteocutaneous flap and an implant-retained obturator. The patient's oral functions were improved when the prosthesis was stabilized by means of dental implants and custom abutments.


Assuntos
Implantação Dentária Endóssea , Retalhos de Tecido Biológico , Procedimentos de Cirurgia Plástica , Implantes Dentários , Prótese Dentária Fixada por Implante , Fíbula , Humanos , Masculino , Pessoa de Meia-Idade
4.
Kokubyo Gakkai Zasshi ; 83(1): 7-12, 2016 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-27443068

RESUMO

Occlusal dysesthesia has been defined as persistent uncomfortable feelings of intercuspal position continuing for more than 6 months without evidence of physical occlusal discrepancy. The problem often occurs after occlusal intervention by dental care. Although various dental treatments (e. g. occlusal adjustment, orthodontic treatment and prosthetic reconstruction) are attempted to solve occlusal dysesthesia, they rarely reach a satisfactory result, neither for patients nor dentists. In Japan, these symptoms are defined by the term "Occlusal discomfort syndrome" (ODS). The aim of this study was to investigate the characteristics of ODS with the simple occlusal sensory perceptive and discriminative test. Twenty-one female dental patients with ODS (mean age 55.8 ± 19.2 years) and 21 age- and gender-matched dental patients without ODS (mean age 53.1 ± 16.8 years) participated in the study. Upon grinding occlusal registration foils that were stacked to different thicknesses, participants reported the thicknesses at which they recognized the foils (recognition threshold) and felt discomfort (discomfort threshold). Although there was no significant difference in occlusal recognition thresholds between the two patient groups, the discomfort threshold was significantly smaller in the patients with ODS than in those without ODS. Moreover, the recognition threshold showed an age-dependent increase in patients without ODS, whereas it remained comparable between the younger (< 60 years old) and elderly (60 years old or more) patient subgroups with ODS. These results suggest that occlusal discomfort threshold rather than recognition threshold is an issue in ODS. The foil grinding procedure is a simple and useful method to evaluate occlusal perceptive and discriminative abilities in patients with ODS.


Assuntos
Oclusão Dentária , Má Oclusão/fisiopatologia , Parestesia/fisiopatologia , Limiar Sensorial/fisiologia , Adulto , Idoso , Envelhecimento/fisiologia , Diagnóstico Bucal/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Percepção/fisiologia , Síndrome
5.
Kokubyo Gakkai Zasshi ; 81(1): 1-8, 2014 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-24812762

RESUMO

The purpose of this study was to investigate new patients who had already received treatment with dental implants. The subjects were patients who visited the clinic for oral implants at Tokyo Medical and Dental University Hospital from April 1995 to March 2012. The results were as follows: 1) Of the total number of patients, there were 2,419 patients (14.0%) with dental implants. 2) Of the 2,419 patients, 252 patients (10.4%) had been referred from operating doctors or operating clinics. 3) There were 1,516 (62.7%) patients with complaints related to the implant therapy. 4) There were 1,367 (56.5%) patients who had ill feelings toward their attending doctors. 5) There were 1,112 (46.0%) patients with biological complications. 6) Regarding patients with or without a referral from the doctor who had performed their dental implant, those patients who had been referred showed significantly higher occurrence of loss of implants, neurological symptoms, doctor's recommendation, prosthetic problems, and surgical problems. Almost implant therapies were treated with other treatments for natural teeth, including surgical treatment, prosthetic treatment, periodontal treatment and maintenance. These were too complex to enable the results to be forecast before treatment, therefore unpredictable symptoms often occur in patients with implant therapy. Informed consent including patient education is important, but the results of this study suggest that it is insufficient at present.


Assuntos
Implantes Dentários , Implantes Dentários/efeitos adversos , Relações Dentista-Paciente , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Encaminhamento e Consulta
6.
J Clin Med ; 13(2)2024 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-38256466

RESUMO

Well-defined, faintly radiopaque lesions are occasionally observed in the antrum of the maxillary sinus in asymptomatic patients during maxillary sinus floor elevation. These lesions are treated as antral pseudocysts (AP) based on the clinical diagnosis in some cases, and maxillary sinus floor elevation is performed without enucleating these lesions. However, further surgery is required after implant placement if the lesion is a mucocele, odontogenic cyst, or tumour. This comprehensive clinical review aimed to identify an appropriate approach for maxillary sinus floor elevation in patients with well-defined, faintly radiopaque lesions in the antrum based on our clinical experience.

7.
Bioengineering (Basel) ; 11(2)2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38391678

RESUMO

Implant therapy is now an established treatment with high long-term success and survival rates. However, early implant failure, which occurs within one year of superstructure placement, occurs at a higher rate than late failure, which is represented by peri-implantitis caused by bacterial infection. Furthermore, various risk factors for early failure have been reported, including patient-related factors, such as systemic diseases, smoking, and bone quality and quantity, as well as surgery-related factors, such as surgeons' skill, osteogenesis technique, and selection of graft material, and implant-related factors, such as initial implant fixation and implant length diameter. Due to the wide variety of relevant factors reported, it is difficult to identify the cause of the problem. The purpose of this review is to discuss the risk factors associated with various types of bone augmentation which have a close causal relationship with early implant failure, and to determine the optimal bone grafting material for bone augmentation procedures to avoid early implant failure.

8.
Bioengineering (Basel) ; 11(2)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38391681

RESUMO

A screw-fixed superstructure is predominantly selected for implant prostheses because of the concern regarding developing peri-implantitis, although its infection route remains unclear. Focusing on microleakage from access holes, the present study clinically investigated the bacterial flora in access holes with different sealing materials. We examined 38 sites in 19 patients with two adjacent screw-fixed superstructures. Composite resin was used in the control group, and zinc-containing glass ionomer cement was used in the test group. Bacteria were collected from the access holes 28 days after superstructure placement and were subjected to DNA hybridization analysis. The same patient comparisons of the bacterial counts showed a significant decrease in 14 bacterial species for the red, yellow, and purple complexes in the test group (p < 0.05). In addition, the same patient comparisons of the bacterial ratios showed a significant decrease in six bacterial species for the orange, green, yellow, and purple complexes in the test group (p < 0.05). Furthermore, the same patient comparisons of the implant positivity rates showed a significant decrease in the six bacterial species for the orange, yellow, and purple complexes in the test group. The results of this study indicate that zinc-containing glass ionomer cement is effective as a sealing material for access holes.

9.
Bioengineering (Basel) ; 11(6)2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38927818

RESUMO

While technological advances have made implants a good treatment option with a good long-term prognosis, peri-implantitis, which results in alveolar bone resorption around implants, has been observed in some cases. Micromotion at the implant abutment connection can cause peri-implantitis. However, the temporal progression of micromotion upon loading remains unclear. Therefore, we aimed to longitudinally measure micromotion upon loading application on an implant. Implants with Morse-tapered connections were prepared. Custom titanium abutments were fabricated and tightened onto implant bodies at 35 N. A 100 N vertical load was applied for 200,000 cycles. Micromotion was measured when the load was applied, as was the total implant length and removal torque before and after loading. The micromotion was measured from the position data of the jig of the testing machine during loading. The average removal torque was 30.67 N after 10 min of tightening and 27.95 N after loading, indicating a decrease due to loading. The implant length reduced by 3.6 µm under the load. The average micromotion was 0.018 mm at 2 cycles, 0.016 mm at 100,000 cycles, and 0.0157 mm at 200,000 cycles, indicating implant length reduction under the load but not reaching 0. The micromotion between the implant and abutment under a cyclic load decreased over time but did not completely cease. These results highlight the relationship between micromotion and loading, underscoring the importance of careful monitoring and management to mitigate potential complications, such as peri-implantitis, and ensure optimal performance and durability of the implant.

10.
Bioengineering (Basel) ; 11(3)2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38534497

RESUMO

Early implant failure occurring within 1 year after implantation has been attributed to various factors. Particularly, early failure can lead to challenges in maintaining a full-arch prosthetic device, necessitating prompt intervention, including reoperation. This study aimed to retrospectively examine implant- and patient-related factors and the effects of photofunctionalisation associated with early failure in patients who underwent treatment using the all-on-four concept in both the maxilla and mandible. We conducted this retrospective study comprising 561 patients with 2364 implants who underwent implant-supported immediate loading with fixed full-arch rehabilitation using the all-on-four concept. We aimed to assess the survival rate within 1 year after implantation and determine the risk factors influencing early failure. The 1-year survival rates after implantation were 97.1% (patient level) and 98.9% (implant level) for the maxilla and 98.5% (patient level) and 99.6% (implant level) for the mandible. There was a significant difference in the implant-level survival rates between the maxilla and mandible, with a lower rate in the maxilla (p = 0.043). The risk factors associated with early implant failure according to the all-on-four concept included the maxilla (implant level) and smoking (patient level). We could not find a significant effect of photofunctionalisation on early failure (p = 0.25) following this treatment protocol.

11.
Bioengineering (Basel) ; 10(10)2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37892840

RESUMO

Maxillary sinus augmentation with a lateral approach (MSA) is a well-established treatment. In this prospective study, we evaluated risk factors for postoperative bone graft displacement and reported the clinical application of long-term resorbable L-lactic acid/-caprolactone (PLA/PCL) as a barrier membrane to cover the open window in the lateral wall in MSA. Twenty-four patients underwent MSA according to the relevant criteria; CT data obtained before and 1 week (1 w) and 5-6 months (5 m) post-MSA, bone height changes, bone height reduction rates at 1 w and 5 m post-MSA, bone graft displacement measurements, and risk factors were examined. All patients showed bone height increments (p < 0.005). However, no difference was observed between 1 w and 5 m post-MSA. Bone graft displacement was observed in eight patients; the reduction rate from 1 w to 5 m post-MSA was 8.38% ± 4.88%. Sex, septa, maxillary sinus floor-palatal bone distance, and maxillary sinus floor-maxillary ostium distance were associated with bone graft displacement (p < 0.05). The height from the maxillary sinus floor to the palatal bone and the sinus angle influenced the augmentation degree (p < 0.05). The PLA/PCL membrane is compared favorably with other membranes and may be useful as a barrier membrane for the MSA open window.

12.
Int J Implant Dent ; 9(1): 43, 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37938479

RESUMO

PURPOSE: Implant-supported immediately loaded fixed full-arch rehabilitation via All-on-four treatment yields good long-term results for both the maxilla and the mandible. However, the risk factors affecting long-term implant survival are unknown, and the long-term prognosis of All-on-four concept procedures in Japanese individuals has not been elucidated. We aimed to determine the cumulative implant survival rate after 3-17-year follow-up and identify the associated risk factors. METHODS: We analysed 561 cases (307 maxillae, 254 mandibles) with 2364 implants (1324 maxillae, 1040 mandibles) that received All-on-four treatment. We investigated the cumulative implant- and patient-level survival rates and various risk factors for implant failure. Statistical analysis was performed using the log-rank test for differences in Kaplan-Meier curves, univariate analysis using the Chi-square test, and multivariate analysis for risk factors affecting the survival rate. RESULTS: The cumulative survival rate was 94.4% by patient level and 97.4% by implant level for the maxilla, and 96.7% by patient level and 98.9% by implant for the mandible, with up to 17 years of follow-up. The maxillary survival rate at the implant level was significantly lower (p < 0.05). Furthermore, the maxillary survival rate within 24 months was significantly lower at the implant level (p < 0.01). Multivariate analysis revealed that the maxilla was the most significant risk factor (p < 0.01). CONCLUSIONS: All-on-four treatment yielded high long-term survival rates in Japanese patients. However, the maxilla showed a significantly lower cumulative survival rate than the mandible, while early failure was significantly higher. Furthermore, the maxilla was a significant risk factor influencing the survival rate.


Assuntos
Maxila , Boca Edêntula , Humanos , Maxila/cirurgia , Taxa de Sobrevida , Estudos Longitudinais , População do Leste Asiático , Seguimentos , Mandíbula/cirurgia , Fatores de Risco
13.
Implant Dent ; 21(6): 496-501, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23080557

RESUMO

PURPOSE: To evaluate whether the measurement accuracy of dental CT images is affected by the mandibular positioning and the pitch factor at CT scanning. MATERIALS AND METHODS: Three dry mandibles were scanned by 64-slice multidetector row CT (MDCT) and micro-CT. For MDCT scanning, 7 different mandibular positioning and 3 different pitch factors were applied. After reformatting dental CT images, the bone height was measured on these images. It was also measured on the corresponding micro-CT image, which was defined as the actual value. The difference of the measurement values between these 2 was defined as the measurement error. RESULTS: There was no significant difference in the measurement errors due to either the mandibular positioning or the pitch factor. CONCLUSION: The measurement accuracy of dental CT images obtained was not affected by either mandibular positioning or pitch factor at CT scanning.


Assuntos
Cefalometria/estatística & dados numéricos , Mandíbula/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/estatística & dados numéricos , Processo Alveolar/diagnóstico por imagem , Anatomia Transversal/estatística & dados numéricos , Meios de Contraste , Arco Dental/diagnóstico por imagem , Marcadores Fiduciais , Guta-Percha , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Mandíbula/anatomia & histologia , Tomografia Computadorizada Multidetectores/métodos , Variações Dependentes do Observador , Coroa do Dente/diagnóstico por imagem , Microtomografia por Raio-X/estatística & dados numéricos
14.
Int J Implant Dent ; 8(1): 19, 2022 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-35428947

RESUMO

PURPOSE: Tooth extraction and the projection of the tooth roots into the maxillary sinus are reported to greatly reduce the bone height from the alveolar ridge to the maxillary sinus floor, while missing teeth are reported to lead to the expansion of the maxillary sinus, all of which are important considerations during dental implant treatment for the maxillary molar region. Therefore, assessing the anatomical characteristics of the maxillary sinus acting as complicating factors is crucial before sinus augmentation. We conducted a three-dimensional examination of the effects of missing teeth and nasal septal deviation (NSD) on maxillary sinus volume (MSV). METHODS: We selected participants with two or more missing teeth from patients who underwent maxillary sinus augmentation for a unilateral free-end saddle between April 2019 and December 2020. We calculated the MSV and NSD using cone-beam computed tomography (CBCT). We compared the relationships of the presence/absence of teeth and NSD with MSV bilaterally in each patient using the Wilcoxon t-test. p-values < 0.05 denoted statistical significance. RESULTS: This study included 30 patients (30 sinuses; 12 men, 18 women). The average patient age was 58.2 ± 10.2 years (men, 60.4 ± 3.7 years; women, 59.2 ± 4.5 years; range, 40-77 years). The mean number of missing teeth was 2.98 ± 1.01: 13 patients had two missing teeth and 17 had three or more missing teeth. Nine patients (30%) had NSD. The mean MSV on the ipsilateral and contralateral sides of the NSD was 21.50 ± 3.84 cm3 and 22.10 ± 3.56 cm3, respectively; thus, NSD did not affect MSV (p = 0.150). The mean MSV on the edentulous and non-edentulous sides was 21.58 ± 3.89 cm3 and 21.77 ± 4.30 cm3, respectively; thus, the MSV was significantly smaller on the edentulous side (p = 0.00036). CONCLUSION: Although this study was a limited preoperative study, three-dimensional measurement of the maxillary sinus with CBCT in partially edentulous patients revealed that missing teeth lead to substantial reductions in MSV, while NSD was not associated with MSV.


Assuntos
Anodontia , Boca Edêntula , Levantamento do Assoalho do Seio Maxilar , Perda de Dente , Adulto , Idoso , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Humanos , Masculino , Seio Maxilar/diagnóstico por imagem , Pessoa de Meia-Idade , Projetos Piloto
15.
J Dent Sci ; 17(2): 891-896, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35756780

RESUMO

Background/purpose: Although several mechanical and chemical debridement techniques have been reported for the management of peri-implantitis, there is no consensus on the most effective method at present. This in vitro study aimed to examine the effects of different mechanical instrumentation techniques on the debridement of hard calcified materials, which are present on the implant surface, as well as the effect of the defect morphology. Materials and methods: From a total of 15 implants, five each were assigned to one of three decontamination groups (Rotary titanium brush [Ti], tricalcium phosphate air powder abrasive treatment [Air], and titanium ultrasonic scaler [US] groups); the exposed hydroxyapatite (HA)-coated portion was divided into three 1-mm sections (coronal, middle, and apical). The residual-HA of each portion was measured using a digital microscope. Results: The overall percentage of residual HA coating was significantly lower in the US group than in the Ti or Air groups (p < 0.01). The percentage of residual HA in the coronal portion was significantly lower in the Ti and US groups than in the Air group (p < 0.05 and p < 0.01, respectively). The percentage of residual HA in the middle portion was significantly lower in the US group than in the Air group (p < 0.01). The percentage of residual HA in the apical portion was significantly lower in the Ti group than in the Air or US groups (p < 0.01). Conclusion: Ti and US were more effective for shallow defects, whereas US was more effective for deeper defects.

16.
Int J Implant Dent ; 7(1): 16, 2021 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-33649993

RESUMO

BACKGROUND: During implant treatment in the maxillary molar area, maxillary sinus floor augmentation is often performed to ameliorate the reduced alveolar bone height attributable to bone remodeling and pneumatization-induced expansion of the maxillary sinus. However, this augmentation may cause complications such as misplaced implants, artery damage, and maxillary sinus mucosal perforation; infections like maxillary sinusitis; and postsurgical complications such as bone graft leakage and postoperative nasal hemorrhaging. To reduce the complications during maxillary sinus floor augmentation and postoperative infections, we performed retrospective investigations of various systemic and local factors that influence pre-operative sinus mucosal thickness (SMT) by using cone-beam computed tomography (CBCT). Subjects included patients who underwent maxillary sinus floor augmentation in an edentulous maxillary molar area with a lateral approach. Pre-operative SMT, existing bone mass, and nasal septum deviation were measured using CBCT images. Relationships between SMT and the following influencing factors were investigated: (1) age, (2) sex, (3) systemic disease, (4) smoking, (5) period after tooth extraction, (6) reason for tooth extraction, (7) residual alveolar bone height (RBH), (8) sinus septa, and (9) nasal septum deviation. Correlations were also investigated for age and RBH (p < 0.05). RESULTS: We assessed 35 patients (40 sinuses; 11 male, 24 female). The average patient age was 58.90 ± 9.0 years (males, 57.9 ± 7.7 years; females, 59.9 ± 9.4 years; age range, 41-79 years). The average SMT was 1.09 ± 1.30 mm, incidence of SMT > 2 mm was 25.0%, incidence of SMT < 0.8 mm was 50.0%, and the average RBH was 2.14 ± 1.02 mm. The factors that influenced SMT included sex (p = 0.0078), period after tooth extraction (p = 0.0075), reason for tooth extraction (p = 0.020), sinus septa (p = 0.0076), and nasal septum deviation (p = 0.038). CONCLUSIONS: Factors associated with higher SMT included male sex, interval following tooth extraction < 6 months, periapical lesions, sinus septa, and nasal septum deviation. Factors associated with SMT > 2 mm were sex and reason for tooth extraction, while factors associated with SMT < 0.8 mm were time following tooth extraction and nasal septum deviation. Despite the limitations of this study, these preoperative evaluations may be of utmost importance for safely conducting maxillary sinus floor augmentation.


Assuntos
Boca Edêntula , Levantamento do Assoalho do Seio Maxilar , Adulto , Idoso , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Masculino , Seio Maxilar/diagnóstico por imagem , Pessoa de Meia-Idade , Estudos Retrospectivos , Levantamento do Assoalho do Seio Maxilar/efeitos adversos
17.
Int J Implant Dent ; 7(1): 34, 2021 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-33977359

RESUMO

BACKGROUND: The vertical thickness of the peri-implant mucosa is associated with the amount of post treatment marginal bone loss. However, the variations in mucosal thickness at the different edentulous sites have been sparsely documented. The purpose of the study was to conduct a survey of the frequency distribution of variations in mucosal thickness at the different sites of the edentulous alveolar ridge and to compare them according to gender. Our study included 125 partially edentulous patients having a total of 296 implant sites. Cone-beam computed tomography (CBCT) scans were obtained by placing a diagnostic template with a radiopaque crown indicator on the ridge to determine the mucosal thickness at the crest of the alveolar ridge. RESULTS: The mucosal thickness was 3.0±1.3 mm in the maxilla, which was significantly greater than the mucosal thickness of 2.0±1.0 mm in the mandible (p<0.001). In both the maxilla and the mandible, the mucosa was the thickest in the anterior region, followed by the premolar and molar regions. Sites were further classified into two groups based on whether the mucosal thickness was greater than 2 mm. In the mandible, more than half of the sites showed a mucosal thickness of 2 mm or less. CONCLUSIONS: Although this study was a limited preoperative study, the vertical mucosal thickness at the edentulous ridge differed between the maxillary and mandibular regions. The majority of sites in the mandibular molar region had a mucosal thickness of less than 2 mm. Practitioners might be able to develop an optimal dental implant treatment plan for long-term biologic and esthetic stability by considering these factors.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Mandíbula , Processo Alveolar/diagnóstico por imagem , Humanos , Mandíbula/diagnóstico por imagem , Maxila/diagnóstico por imagem , Mucosa
18.
Int J Implant Dent ; 6(1): 42, 2020 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-32815046

RESUMO

BACKGROUND: Primary implant stability is essential for osseointegration. To increase stability without changing the implant size, the thread length must be extended by reducing pitch, using a double-threaded implant, or reducing pitch/lead and lead angle to half that of a single-threaded implant. MATERIALS AND METHODS: We tested the stabilities of these configurations using artificial bone. A 1.2-mm pitch, single-threaded implant (12S) was the control. We tested a 0.6-mm pitch/1.2-mm-lead double-threaded implant (06D) and a 0.6-mm pitch/lead single-threaded implant (06S). We compared stabilities by measuring insertion torque, removal torque, and the implant stability quotient (ISQ). Damage to bone tissue caused by the implants was evaluated using microscopy and morphometric analysis. RESULTS: We show that 06D and 06S significantly improved stability compared with the 12S reference. The stability of 06S was significantly greater compared with that of 06D, except for ISQ. The three implants were associated with bone tissue damage characterized by debris and voids surrounding the implant/bone interface. The 06D caused the most tissue damage, followed by 06S and then 12S. CONCLUSION: These findings indicate that primary stability was significantly improved by changing the implant size, extending the thread length with reduced pitch/lead, and reducing the lead angle to half that of a single-threaded implant compared with a double-threaded implant.

19.
Int J Implant Dent ; 6(1): 27, 2020 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-32648123

RESUMO

BACKGROUND: We performed maxillary sinus floor augmentation using the crestal approach and beta-tricalcium phosphate (ß-TCP) and a long-term evaluation using cone-beam computed tomography (CBCT). METHODS: Twenty-three patients (30 implants) underwent sinus floor augmentation using the osteotome technique. Subjects underwent CBCT imaging before surgery, immediately after surgery, and at follow-up (≥ 3 years after surgery). We measured the changes in height of the augmented sinus floor (SL), the augmented bone above apex of the implant (BH), and the implant length that projected into the sinus (IL). RESULTS: The mean SL decreased from 6.54 ± 1.51 (immediately after surgery) to 3.11 ± 1.35 mm (follow-up). The mean BH decreased from 3.17 ± 0.97 to - 0.25 ± 1.19 mm; the maxillary sinus floor in many implants was near the apex at follow-up. The SL at follow-up showed a strong correlation with the IL (p = 0.0057). CONCLUSIONS: Osteotome sinus floor elevation with beta-tricalcium phosphate was clinically effective. Cone-beam computed tomography analysis revealed that ≥ 3 years after surgery, the maxillary sinus floor was near the apex of the implant.

20.
J Oral Biosci ; 62(2): 131-138, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32289529

RESUMO

OBJECTIVES: To gain insight into the role of the N-methyl-d-aspartate (NMDA) receptor in bone metabolism by examining the effects of its noncompetitive antagonist, MK-801 (dizocilpine), on bone homeostasis and bone healing in mice. METHODS: MK-801 (2.5 mg/kg) or saline (in control groups) was intravenously administered to healthy mice and mice with bone-defects daily for seven to 14 days. Bone defects were artificially created in femurs using a drill and reamer. Following euthanasia, bones were extracted and processed for microcomputed tomography (µCT) and histological analyses. The effects of MK-801 on osteoclast differentiation by bone marrow macrophages (BMMs) were examined in vitro. mRNA expressionlevels of Grin3b levels were also examined using reverse-transcription polymerase chain reaction (RT-PCR). RESULTS: Bone volume was significantly decreased in mice administered MK-801 for 14 days. Additionally, the number of osteoclasts was reduced, while number of osteoblasts and rate of bone formation were increased in these mice. MK-801 inhibited osteoclast differentiation dose-dependently in vitro. RT-PCR findings suggested expression of Grin3b, a subunit of the NMDA receptor, in BMMs. During the healing process of artificially created defects in femurs, no significant differences were found between the control and MK-801-treated groups, indicating no stimulatory or inhibitory effects by MK-801 administration. CONCLUSIONS: These results indicate that blockade of the NMDA receptor by MK-801 administration affects bone metabolism but not the healing process of artificial bone defects.


Assuntos
Maleato de Dizocilpina , Receptores de N-Metil-D-Aspartato , Animais , Homeostase , Camundongos , N-Metilaspartato , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA