Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 97(3): 516-526, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32865860

RESUMO

OBJECTIVE: To evaluate the incidence, predictors and outcomes of female patients with patient-prosthesis mismatch (PPM) following transcatheter aortic valve intervention (TAVI) for severe aortic stenosis (AS). BACKGROUND: Female AS TAVI recipients have a significantly lower mortality than surgical aortic valve replacement (SAVR) recipients, which could be attributed to the potentially lower PPM rates. TAVI has been associated with lower rates of PPM compared to SAVR. PPM in females post TAVI has not been investigated to date. METHODS: The WIN-TAVI (Women's INternational Transcatheter Aortic Valve Implantation) registry is a multicenter registry of women undergoing TAVR for severe symptomatic AS. Two hundred and fifty patients with detailed periprocedural and follow-up echocardiographic investigations were included in the WIN-TAVI echocardiographic sub-study. PPM was defined as per European guidelines stratified by the presence of obesity. RESULTS: The incidence of PPM in our population was 32.8%. Patients with PPM had significantly higher BMI (27.4 ± 6.1 vs. 25.2 ± 5.0, p = .002), smaller sized valves implanted (percentage of TAVI ≤23 mm 61% vs. 29.2%, PPM vs. no PPM, p < .001) and were more often treated with balloon expandable valves (48.3 vs. 32.5%, p < .001) rather than self expanding ones (26.3 vs. 52.8%, <.001). BMI (OR = 1.08; 95%CI 1.02-1.14, p = .011) and valve size ≤23 mm (OR = 3.00 95%CI 1.14-7.94, p = .027) were the only independent predictors of PPM. There was no significant interaction between valve size and valve type (p = .203). No significant differences were observed in 1-year mortality or major adverse cardiovascular events. CONCLUSIONS: PPM in females undergoing TAVI occurs in one third of patients. BMI and valve size ≤23 mm are independent predictors. Larger registries are required to determine the impact of PPM on future clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Complicações Pós-Operatórias , Prevalência , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Lancet ; 392(10153): 1117-1126, 2018 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-30190206

RESUMO

BACKGROUND: The FIREHAWK is a drug-eluting stent with a fully biodegradable sirolimus-containing polymer coating localised to recessed abluminal grooves on the stent surface. We investigated clinical outcomes with this targeted, low-dose, biodegradable polymer, sirolimus-eluting stent compared with XIENCE durable polymer, everolimus-eluting stents in an all-comers population. METHODS: The TARGET All Comers study was a prospective, multicentre, open-label randomised non-inferiority trial done at 21 centres in ten European countries. Patients with symptomatic or asymptomatic coronary artery disease and objective evidence of myocardial ischaemia who qualified for percutaneous coronary intervention were randomised 1:1 to undergo implantation of a FIREHAWK or XIENCE. Randomisation was web-based, with random block allocation and stratification by centre and ST elevation myocardial infarction. Outcome assessors were masked to treatment allocation, but treating physicians and patients were not. The primary endpoint was target lesion failure at 12 months, a composite of cardiac death, target vessel myocardial infarction, or ischaemia-driven target lesion revascularisation. The control event rate for XIENCE was assumed to be 7%, the non-inferiority margin was 3.5%, and the primary analysis was in the intention-to-treat population, censoring patients who did not have either an event before 365 days or contact beyond 365 days. Late lumen loss was the primary endpoint of an angiographic substudy designed to investigate the non-inferiority of the FIREHAWK compared with the XIENCE stent. This trial is registered with ClinicalTrials.gov, number NCT02520180. FINDINGS: From Dec 17, 2015, to Oct 14, 2016, 1653 patients were randomly assigned to implantation of the FIREHAWK (n=823) or XIENCE (n=830). 65 patients in the FIREHAWK group and 66 in the XIENCE group had insufficient follow-up data and were excluded from the analyses. At 12 months, target lesion failure occurred in 46 (6·1%) of 758 patients in the FIREHAWK group and in 45 (5·9%) of 764 patients in the XIENCE group (difference 0·2%, 90% CI -1·9 to 2·2, pnon-inferiority=0·004, 95% CI -2·2 to 2·6, psuperiority=0·88). There were no differences in ischaemia-driven revascularisation or stent thrombosis rates at 12 months. 176 patients were included in the angiographic substudy, in which in-stent late lumen loss was 0·17 mm (SD 0·48) in the FIREHAWK group and 0·11 mm (0·52) in the XIENCE group (p=0·48), with an absolute difference of 0·05 mm (95% CI -0·09 to 0·18, pnon-inferiority=0·024). INTERPRETATION: In a broad all-comers population of patients requiring stent implantation for myocardial ischaemia, the FIREHAWK was non-inferior to the XIENCE as assessed with the primary endpoint of target lesion failure at 12 months and in-stent late lumen loss at 13 months. The FIREHAWK is a safe and effective alternative stent to treat patients with ischaemic coronary artery disease in clinical practice. FUNDING: Shanghai Microport Medical.


Assuntos
Implantes Absorvíveis , Stents Farmacológicos , Imunossupressores/administração & dosagem , Isquemia Miocárdica/cirurgia , Sirolimo/administração & dosagem , Idoso , Estudos de Equivalência como Asunto , Everolimo/administração & dosagem , Feminino , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
3.
Pacing Clin Electrophysiol ; 42(10): 1331-1339, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31424091

RESUMO

BACKGROUND: Enterococcal cardiovascular implantable electronic device (CIED) infections are not well characterized. METHODS: Data from the Multicenter Electrophysiologic Device Infection Cohort, a prospective study of CIED infections, were used for descriptive analysis of adults with enterococcal CIED infections. RESULTS: Of 433 patients, 21 (4.8%) had enterococcal CIED infection. Median age was 71 years. Twelve patients (57%) had permanent pacemakers, five (24%) implantable cardioverter defibrillators, and four (19%) biventricular devices. Median time from last procedure to infection was 570 days. CIED-related bloodstream infections occurred in three patients (14%) and 18 (86%) had infective endocarditis (IE), 14 (78%) of which were definite by the modified Duke criteria. IE cases were classified as follows: valvular IE, four; lead IE, eight; both valve and lead IE, six. Vegetations were demonstrated by transesophageal echocardiography in 17 patients (81%). Blood cultures were positive in 19/19 patients with confirmed results. The most common antimicrobial regimen was penicillin plus an aminoglycoside (33%). Antibiotics were given for a median of 43 days. Only 14 patients (67%) underwent device removal. There was one death during the index hospitalization with four additional deaths within 6 months (overall mortality 24%). There were no relapses. CONCLUSIONS: Enterococci caused 4.8% of CIED infections in our cohort. Based on the late onset after device placement or manipulation, most infections were likely hematogenous in origin. IE was the most common infection syndrome. Only 67% of patients underwent device removal. At 6 months follow-up, no CIED infection relapses had occurred, but overall mortality was 24%.


Assuntos
Desfibriladores Implantáveis/microbiologia , Endocardite Bacteriana/microbiologia , Enterococcus/isolamento & purificação , Infecções por Bactérias Gram-Positivas/microbiologia , Marca-Passo Artificial/microbiologia , Complicações Pós-Operatórias/microbiologia , Infecções Relacionadas à Prótese/microbiologia , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Ecocardiografia Transesofagiana , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/tratamento farmacológico , Feminino , Infecções por Bactérias Gram-Positivas/diagnóstico por imagem , Infecções por Bactérias Gram-Positivas/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/tratamento farmacológico
4.
N Engl J Med ; 372(15): 1389-98, 2015 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-25853743

RESUMO

BACKGROUND: During primary percutaneous coronary intervention (PCI), manual thrombectomy may reduce distal embolization and thus improve microvascular perfusion. Small trials have suggested that thrombectomy improves surrogate and clinical outcomes, but a larger trial has reported conflicting results. METHODS: We randomly assigned 10,732 patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary PCI to a strategy of routine upfront manual thrombectomy versus PCI alone. The primary outcome was a composite of death from cardiovascular causes, recurrent myocardial infarction, cardiogenic shock, or New York Heart Association (NYHA) class IV heart failure within 180 days. The key safety outcome was stroke within 30 days. RESULTS: The primary outcome occurred in 347 of 5033 patients (6.9%) in the thrombectomy group versus 351 of 5030 patients (7.0%) in the PCI-alone group (hazard ratio in the thrombectomy group, 0.99; 95% confidence interval [CI], 0.85 to 1.15; P=0.86). The rates of cardiovascular death (3.1% with thrombectomy vs. 3.5% with PCI alone; hazard ratio, 0.90; 95% CI, 0.73 to 1.12; P=0.34) and the primary outcome plus stent thrombosis or target-vessel revascularization (9.9% vs. 9.8%; hazard ratio, 1.00; 95% CI, 0.89 to 1.14; P=0.95) were also similar. Stroke within 30 days occurred in 33 patients (0.7%) in the thrombectomy group versus 16 patients (0.3%) in the PCI-alone group (hazard ratio, 2.06; 95% CI, 1.13 to 3.75; P=0.02). CONCLUSIONS: In patients with STEMI who were undergoing primary PCI, routine manual thrombectomy, as compared with PCI alone, did not reduce the risk of cardiovascular death, recurrent myocardial infarction, cardiogenic shock, or NYHA class IV heart failure within 180 days but was associated with an increased rate of stroke within 30 days. (Funded by Medtronic and the Canadian Institutes of Health Research; TOTAL ClinicalTrials.gov number, NCT01149044.).


Assuntos
Trombose Coronária/terapia , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea , Trombectomia , Idoso , Doenças Cardiovasculares/mortalidade , Doenças Cardiovasculares/prevenção & controle , Terapia Combinada/efeitos adversos , Trombose Coronária/complicações , Eletrocardiografia , Feminino , Insuficiência Cardíaca/etiologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Microvasos , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Intervenção Coronária Percutânea/efeitos adversos , Acidente Vascular Cerebral/etiologia , Trombectomia/efeitos adversos
5.
Pacing Clin Electrophysiol ; 41(5): 524-531, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29518265

RESUMO

BACKGROUND: Published guidelines mandate complete device removal in cases of cardiovascular implantable electronic device (CIED) infection. Clinical predictors of successful salvage of infected CIEDs have not been defined. METHODS: Data from the Multicenter Electrophysiologic Device Infection Collaboration, a prospective, observational, multinational cohort study of CIED infection, were used to investigate whether clinical predictors of successful salvage of infected devices could be identified. RESULTS: Of 433 adult patients with CIED infections, 306 (71%) underwent immediate device explantation. Medical management with device retention and antimicrobial therapy was initially attempted in 127 patients (29%). "Early failure" of attempted salvage occurred in 74 patients (58%) who subsequently underwent device explantation during the index hospitalization. The remaining 53 patients (42%) in the attempted salvage group retained their CIED. Twenty-six (49%) had resolution of CIED infection (successful salvage group) whereas 27 patients (51%) experienced "late" salvage failure. Upon comparing the salvage failure group, early and late (N = 101), to the group experiencing successful salvage of an infected CIED (N = 26), no clinical or laboratory predictors of successful salvage were identified. However, by univariate analysis, coagulase-negative staphylococci as infecting pathogens (P = 0.0439) and the presence of a lead vegetation (P = 0.024) were associated with overall failed salvage. CONCLUSIONS: In patients with definite CIED infections, clinical and laboratory variables cannot predict successful device salvage. Until new data are forthcoming, device explantation should remain a mandatory and early management intervention in patients with CIED infection in keeping with existing expert guidelines unless medical contraindications exist or patients refuse device removal.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Infecções Relacionadas à Prótese/terapia , Terapia de Salvação , Idoso , Remoção de Dispositivo , Feminino , Humanos , Masculino , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Falha de Tratamento
6.
Eur Heart J ; 38(13): 961-969, 2017 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-27190095

RESUMO

Aims: Although a true clinical challenge, high bleeding risk patients with an acute coronary syndrome (ACS) undergoing percutaneous coronary intervention (PCI) have never been specifically studied. Leaders Free ACS, a pre-specified Leaders Free sub-study, determined efficacy, and safety of a combination of 1-month dual anti-platelet therapy (DAPT) with implantation of either a polymer-free Biolimus-A9-coated stent (BA9-DCS) or a bare-metal stent (BMS) in these patients. Methods and results: Leaders Free included 2466 patients undergoing PCI who had at least 1 of 13 pre-defined factors for an increased bleeding risk. Of these, 659 ACS patients were included in this analysis (BA9-DCS 330, BMS 329). At 12-month follow-up, treatment with the BA9-DCS was more effective (clinically driven target-lesion revascularization 3.9 vs. 9.0%, P = 0.009) and safer (cumulative incidence of cardiac death, myocardial infarction, or definite or probable stent thrombosis 9.3 vs. 18.5%, P = 0.001), driven by significantly lower rates of cardiac mortality (3.4 vs. 6.9%, P = 0.049) and myocardial infarction (6.9 vs. 13.8%, P = 0.005). Conclusion: We believe that the results of this sub-analysis from the Leaders Free trial are likely to significantly impact clinical practice for high bleeding risk patients presenting with an ACS: the use of a BMS can, in our view, no longer be recommended, and, given the paucity of available data for second-generation DES with shortened DAPT in these patients, the BA9-DCS should currently be considered as the device with the strongest evidence to support its use for this indication.


Assuntos
Stents Farmacológicos , Hemorragia/etiologia , Imunossupressores/administração & dosagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/cirurgia , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Sirolimo/análogos & derivados , Síndrome Coronariana Aguda/cirurgia , Idoso , Método Duplo-Cego , Quimioterapia Combinada , Feminino , Oclusão de Enxerto Vascular/etiologia , Humanos , Masculino , Infarto do Miocárdio sem Supradesnível do Segmento ST/tratamento farmacológico , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/administração & dosagem , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/tratamento farmacológico , Sirolimo/administração & dosagem , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 85(7): 1217-25, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25581785

RESUMO

AIMS: To compare 30-day performance of three different type of transcatheter aortic valve implantation (TAVI) prosthesis: Direct Flow Medical (DFM), Medtronic Corevalve (MCV), and Edwards Sapien XT (ES). METHODS AND RESULTS: Forty consecutive patients treated with DFM for severe aortic stenosis were matched to an equal sample of patients undergoing TAVI with MCV and ES (1:1:1 propensity score-matching). Primary end-point was 30-day safety, defined according to the valve academic research consortium (VARC-2) criteria. Secondary end-points were: (i) immediate post-TAVI transaortic gradient reduction, (ii) device success, and (iii) 30-day mortality. Patients treated with DFM had higher 30-day safety rate compared to MCV and ES (respectively: 95.0% vs. 67.5% vs. 82.5%; P=0.006). Immediate post-TAVI, transaortic gradient reduction was similar for DFM, MCV, and ES subgroups (respectively: 8.3 ± 5.2 mm Hg vs. 5.3 ± 3.7 mm Hg vs. 5.6 ± 5.1 mm Hg; P=0.15); likewise, device success did not differ significantly (respectively: 100% vs. 92.5% vs. 92.5%; P=0.19). Mortality rates were also similar (respectively: 0% vs. 7.5% vs. 7.5%; P=0.190). In the pooled binary logistic regression analysis, blood transfusion was associated to 30-day safety (HR 0.156, 95% CI 0.049-0.500, P=0.002), while a significant trend was observed for the vascular closure device type (favoring Proglide vs. Prostar: HR 0.239, 95% CI 0.049-1.160, P=0.076). CONCLUSIONS: In high-risk patients with aortic stenosis undergoing TAVI, device success and short-term mortality were comparable between DFM, MCV, and ES. In contrast, the 30-day VARC-defined safety primary end-point was met significantly more frequently in patients treated with DFM. This result was mainly driven by differences in major vascular complications, associated to differences in vascular closure devices between the different valve subgroups.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Angiografia Coronária , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Pontuação de Propensão , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
9.
Int J Med Sci ; 12(5): 378-86, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26005372

RESUMO

BACKGROUND/OBJECTIVES: Non-ST segment elevation myocardial infarction (MI) poses similar detrimental long-term prognosis as ST-segment elevation MI. No marker on ECG is established to predict successful reperfusion in NSTEMI. QT dispersion is increased by myocardial ischemia and reduced by successful restoration of epicardial blood flow by PCI. Whether QT dispersion reduction translates to smaller infarcts and thus indicates successful reperfusion is unknown. We hypothesized that the relative reduction of QT dispersion (QTD-Rrel ) on a standard ECG in acutely reperfused NSTEMI is related to infarct size and infarct transmurality as assessed by delayed enhancement CMR (DE-CMR). METHODS AND RESULTS: 69 patients with a first acute NSTEMI were included. QTD-Rrel was stratified according to LV function and volumes, infarct transmurality and size as assessed by DE-CMR. Extensive myocardial infarction was defined as above median infarct size. LV function and end-systolic volume were only mildly related to QTD-Rrel . QTD-Rrel was inversely related to infarct size (r=-0.506,p=0.001) and infarct transmurality (r=-0.415, p=0.001). QTD-Rrel was associated with extensive myocardial infarction in univariate analysis (odds ratio (OR) 0.958, CI 0.935-0.982; p=0.001). Compared to clinical and angiographic data QTD-Rrel remained the only independent predictor of non-transmural infarcts (OR 1.110, CI 1.055-1.167; p=0.049). CONCLUSION: In patients with acute Non-ST-Segment Myocardial infarction QTd-Rrel calculated on a surface ECG prior and post PCI for restoration of epicardial blood flow detects small, non-transmural infarcts as assessed by delayed enhancement CMR. Thus, QTd-Rrel can indicate successful reperfusion therapy.


Assuntos
Eletrocardiografia , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/fisiopatologia , Idoso , Angiografia Coronária , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Reperfusão Miocárdica , Função Ventricular Esquerda
11.
Eur Heart J Qual Care Clin Outcomes ; 10(1): 25-35, 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-37286294

RESUMO

AIMS: As a consequence of untimely or missed revascularization of ST-elevation myocardial infarction (STEMI) patients during the COVID-19 pandemic, many patients died at home or survived with serious sequelae, resulting in potential long-term worse prognosis and related health-economic implications.This analysis sought to predict long-term health outcomes [survival and quality-adjusted life-years (QALYs)] and cost of reduced treatment of STEMIs occurring during the first COVID-19 lockdown. METHODS AND RESULTS: Using a Markov decision-analytic model, we incorporated probability of hospitalization, timeliness of PCI, and projected long-term survival and cost (including societal costs) of mortality and morbidity, for STEMI occurring during the first UK and Spanish lockdowns, comparing them with expected pre-lockdown outcomes for an equivalent patient group.STEMI patients during the first UK lockdown were predicted to lose an average of 1.55 life-years and 1.17 QALYs compared with patients presenting with a STEMI pre-pandemic. Based on an annual STEMI incidence of 49 332 cases, the total additional lifetime costs calculated at the population level were £36.6 million (€41.3 million), mainly driven by costs of work absenteeism. Similarly in Spain, STEMI patients during the lockdown were expected to survive 2.03 years less than pre-pandemic patients, with a corresponding reduction in projected QALYs (-1.63). At the population level, reduced PCI access would lead to additional costs of €88.6 million. CONCLUSION: The effect of a 1-month lockdown on STEMI treatment led to a reduction in survival and QALYs compared to the pre-pandemic era. Moreover, in working-age patients, untimely revascularization led to adverse prognosis, affecting societal productivity and therefore considerably increasing societal costs.


Assuntos
COVID-19 , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , COVID-19/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Pandemias , Estresse Financeiro , Controle de Doenças Transmissíveis
12.
Eur Heart J ; 33(7): 822-8, 828a, 828b, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21406443

RESUMO

AIMS: Risk scores provide an important contribution to clinical decision-making, but their validity has been questioned in patients with valvular heart disease (VHD), since current scores have been mainly derived and validated in adults undergoing coronary bypass surgery. The Working Group on Valvular Heart Disease of the European Society of Cardiology reviewed the performance of currently available scores when applied to VHD, in order to guide clinical practice and future development of new scores. METHODS AND RESULTS: The most widely used risk scores (EuroSCORE, STS, and Ambler score) were reviewed, analysing variables included and their predictive ability when applied to patients with VHD. These scores provide relatively good discrimination, i.e. a gross estimation of risk category, but cannot be used to estimate the exact operative mortality in an individual patient because of unsatisfactory calibration. CONCLUSION: Current risk scores do not provide a reliable estimate of exact operative mortality in an individual patient with VHD. They should therefore be interpreted with caution and only used as part of an integrated approach, which incorporates other patient characteristics, the clinical context, and local outcome data. Future risk scores should include additional variables, such as cognitive and functional capacity and be prospectively validated in high-risk patients. Specific risk models should also be developed for newer interventions, such as transcatheter aortic valve implantation.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Medição de Risco/métodos , Calibragem , Tomada de Decisões , Doenças das Valvas Cardíacas/mortalidade , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Assistência Perioperatória/mortalidade , Medição de Risco/normas , Sensibilidade e Especificidade , Resultado do Tratamento
13.
EuroIntervention ; 19(10): e844-e855, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-37860860

RESUMO

BACKGROUND: In the prospective, multicentre, randomised TARGET All Comers study, percutaneous coronary intervention (PCI) with the FIREHAWK biodegradable-polymer sirolimus-eluting stent (BP-SES) was non-inferior to the durable-polymer everolimus-eluting stent (DP-EES) for the primary endpoint of target lesion failure (TLF) at 12 months. AIMS: We aimed to report the final study outcomes at 5 years. METHODS: Patients referred for PCI were randomised to receive either a BP-SES or DP-EES in a 1:1 ratio in 10 European countries. Randomisation was stratified by centre and ST-elevation myocardial infarction (STEMI) presentation, and clinical follow-up extended to 5 years. The primary endpoint was TLF (composite of cardiac death, target vessel myocardial infarction [MI], or ischaemia-driven target lesion revascularisation). Secondary endpoints included patient-oriented composite events (POCE; composite of all-cause death, all MI, or any revascularisation and its components). RESULTS: From December 2015 to October 2016, 1,653 patients were randomly assigned to the BP-SES or DP-EES groups, of which 93.8% completed 5-year clinical follow-up or were deceased. At 5 years, TLF occurred in 17.1% of the BP-SES group and in 16.3% of the DP-EES group (p=0.68). POCE occurred in 34.0% of the BP-SES group and 32.7% of the DP-EES group (p=0.58). Revascularisation was the most common POCE, occurring in 19.3% of patients receiving BP-SES and 19.2% receiving DP-EES, of which less than one-third was ischaemia-driven target lesion-related. In the landmark analysis, there were no differences in the rates of TLF and POCE between groups from 1 to 5 years, and these results were consistent across all subgroups. CONCLUSIONS: In an all-comers population requiring stent implantation for myocardial ischaemia, the BP-SES was non-inferior to the DP-EES for the primary endpoint of TLF at 12 months, and results were sustained at 5 years, confirming the long-term safety and efficacy of the FIREHAWK BP-SES.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Sirolimo , Stents Farmacológicos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Implantes Absorvíveis , Everolimo , Infarto do Miocárdio/etiologia , Polímeros
14.
JACC Cardiovasc Interv ; 16(16): 2004-2017, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37480891

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Incidência , Bloqueio de Ramo , Prognóstico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
15.
Circ Cardiovasc Interv ; 16(1): e012538, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36649387

RESUMO

BACKGROUND: In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves. METHODS: This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated. RESULTS: In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1-4, 4.1% [2.8-6.3%], 3.7% [2.6-5.3%], 3.3% [2.4-4.9%], 2.9% [2.2-4.3%]; P<0.001) and more moderate or heavy valve calcification (Q1-4, 80%, 80%, 82%, 88%; P=0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1-4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P=0.023) and early safety (Q1-4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P<0.001), with fewer permanent pacemaker implantations (Q1-4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P=0.023) and residual mild or greater paravalvular leaks (Q1-4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P<0.001). CONCLUSIONS: TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Tempo , Resultado do Tratamento , Sistema de Registros , Desenho de Prótese , Fatores de Risco
16.
Chemotherapy ; 57(5): 402-16, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22024700

RESUMO

BACKGROUND: Our objectives were to assess the pharmacokinetic interaction and body fluid penetration of ciprofloxacin and levofloxacin. METHODS: This study was a single-dose open randomized three-way crossover in 15 healthy volunteers receiving 500 mg oral levofloxacin, 500 mg oral ciprofloxacin, or 250 mg levofloxacin and 250 mg ciprofloxacin co-administered. Serum, urine, and body fluid concentrations were determined by high-performance liquid chromatography and analyzed via population pharmacokinetic modeling. RESULTS: Modeling indicated that ciprofloxacin inhibited the renal reabsorption of levofloxacin. Ciprofloxacin increased the net renal clearance of levofloxacin by 13%, as its estimated affinity for a putative tubular reabsorption transporter was 12-fold higher (Km: 568 µM) compared to levofloxacin (Km: 6,830 µM). Levofloxacin increased the bioavailability of ciprofloxacin by 12% and achieved significantly (p < 0.05) higher concentrations at 3 h in ejaculate, prostatic, seminal, and vaginal fluid compared to ciprofloxacin. CONCLUSION: Modeling suggested that ciprofloxacin inhibited the tubular reabsorption of levofloxacin due to a 12-fold higher affinity for a putative tubular reabsorption transporter compared to levofloxacin. This pharmacokinetic interaction was not clinically relevant.


Assuntos
Líquidos Corporais/metabolismo , Ciprofloxacina/farmacocinética , Levofloxacino , Ofloxacino/farmacocinética , Próstata/metabolismo , Glândulas Seminais/metabolismo , Vagina/metabolismo , Adolescente , Adulto , Líquidos Corporais/efeitos dos fármacos , Ciprofloxacina/administração & dosagem , Estudos Cross-Over , Combinação de Medicamentos , Interações Medicamentosas , Feminino , Humanos , Masculino , Ofloxacino/administração & dosagem , Próstata/efeitos dos fármacos , Sêmen/efeitos dos fármacos , Sêmen/metabolismo , Glândulas Seminais/efeitos dos fármacos , Distribuição Tecidual/efeitos dos fármacos , Distribuição Tecidual/fisiologia , Vagina/efeitos dos fármacos , Adulto Jovem
17.
Eur Radiol ; 20(1): 73-80, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19633859

RESUMO

We compared four-dimensional guide-point modelling left ventricular function analysis (4DVF) results of cine images in four short-axis and two long-axis slices acquired in a single breath-hold, obtained with the temporal parallel acquisition technique (TPAT), with standard left ventricular function (LVF) analysis results determined by the summation of discs method, in patients who had recently suffered myocardial infarction. Despite wall motion abnormalities, 4DVF yields results for left ventricular ejection fractions and end-diastolic and end-systolic volumes that are in excellent agreement with standard LVF analysis results in these patients. A shortened cardiac magnetic resonance (CMR) protocol using single breath-hold cine image acquisition could facilitate the assessment of left ventricular function soon after myocardial infarction in critically ill patients who are unable to comply with the multiple breath-holds required for standard LVF analysis.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Disfunção Ventricular Esquerda/diagnóstico , Artefatos , Simulação por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Infarto do Miocárdio/complicações , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Volume Sistólico , Disfunção Ventricular Esquerda/etiologia
18.
Eur Heart J Acute Cardiovasc Care ; 9(8): 902-910, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31557050

RESUMO

AIMS: The Stent for Life initiative aims at the reduction of mortality in patients with ST-elevation myocardial infarction by enhancing timely access to primary percutaneous coronary intervention. To assess the associated health and socioeconomic impact, the Stent for Life economic project was launched and applied to four model regions: Romania, Portugal, the Basque Country in Spain, and the Kemerovo region in the Russian Federation. METHODS AND RESULTS: The Stent for Life economic model is based on a decision tree that incorporates primary percutaneous coronary intervention rates and mortality. Healthcare costs and indirect costs caused by loss of productivity were estimated. A baseline scenario simulating the status quo was compared to the Stent for Life scenario which integrated changes initiated by the Stent for Life programme. In the four model regions, primary percutaneous coronary intervention numbers rose substantially between 29-303%, while ST-elevation myocardial infarction mortality was reduced between 3-10%. Healthcare costs increased by 8% to 70%. Indirect cost savings ranged from 2-7%. Net societal costs were reduced in all model regions by 2-4%. CONCLUSION: The joint effort of the Stent for Life initiative and their local partners successfully saves lives. Moreover, the increase in healthcare costs was outweighed by indirect cost savings, leading to a net cost reduction in all four model regions. These findings demonstrate that systematic investments to improve the access of ST-elevation myocardial infarction patients to guideline-coherent therapy is beneficial, not only for the individual, but also for the society at large.


Assuntos
Modelos Econômicos , Cooperação do Paciente , Intervenção Coronária Percutânea/economia , Sistema de Registros , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Stents , Redução de Custos , Humanos , Intervenção Coronária Percutânea/métodos , Portugal/epidemiologia , Fatores de Risco , Romênia/epidemiologia , Federação Russa/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/economia , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Espanha/epidemiologia , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
19.
J Am Coll Cardiol ; 75(21): 2664-2678, 2020 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-32466881

RESUMO

BACKGROUND: In patients with coronary in-stent restenosis (ISR) requiring reintervention, it is unclear if the choice of treatment should depend on whether the restenotic stent was a bare-metal stent (BMS) or a drug-eluting stent (DES). OBJECTIVES: This study aimed to assess the comparative efficacy and safety of the 2 most frequently used treatments - angioplasty with drug-coated balloon (DCB) and repeat stenting DES - in patients with BMS-and DES-ISR. METHODS: The DAEDALUS (Difference in Antirestenotic Effectiveness of Drug-Eluting Stent and Drug-Coated Balloon Angioplasty for the Occurrence of Coronary In-Stent Restenosis) study was a pooled analysis of individual patient data from all 10 existing randomized clinical trials comparing DCB angioplasty with repeat DES implantation for the treatment of coronary ISR. In this pre-specified analysis, patients were stratified according to BMS- versus DES-ISR and treatment assigned. The primary efficacy endpoint was target lesion revascularization (TLR) at 3 years. The primary safety endpoint was a composite of all-cause death, myocardial infarction, or target lesion thrombosis at 3 years. Primary analysis was performed by mixed-effects Cox models accounting for the trial of origin. Secondary analyses included nonparsimonious multivariable adjustment accounting also for multiple lesions per patient and 2-stage analyses. RESULTS: A total of 710 patients with BMS-ISR (722 lesions) and 1,248 with DES-ISR (1,377 lesions) were included. In patients with BMS-ISR, no significant difference between treatments was observed in terms of primary efficacy (9.2% vs. 10.2%; hazard ratio [HR]: 0.83; 95% confidence interval [CI]: 0.51 to 1.37) and safety endpoints (8.7% vs. 7.5%; HR: 1.13; 95% CI: 0.65 to 1.96); results of secondary analyses were consistent. In patients with DES-ISR, the risk of the primary efficacy endpoint was higher with DCB angioplasty than with repeat DES implantation (20.3% vs. 13.4%; HR: 1.58; 95% CI: 1.16 to 2.13), whereas the risk of the primary safety endpoint was numerically lower (9.5% vs. 13.3%; HR: 0.69; 95% CI: 0.47 to 1.00); results of secondary analyses were consistent. Regardless of the treatment used, the risk of TLR was lower in BMS- versus DES-ISR (9.7% vs. 17.0%; HR: 0.56; 95% CI: 0.42 to 0.74), whereas safety was not significantly different between ISR types. CONCLUSIONS: At 3-year follow-up, DCB angioplasty and repeat stenting with DES are similarly effective and safe in the treatment of BMS-ISR, whereas DCB angioplasty is significantly less effective than repeat DES implantation in the treatment DES-ISR, and associated with a nonsignificant reduction in the primary composite safety endpoint. Overall, DES-ISR is associated with higher rates of treatment failure and similar safety compared with BMS-ISR.


Assuntos
Angioplastia Coronária com Balão/mortalidade , Reestenose Coronária/terapia , Stents Farmacológicos , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto
20.
Am J Cardiol ; 125(9): 1369-1377, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32098656

RESUMO

Safety and feasibility of transfemoral Acurate neo implantation without systematic predilatation are not fully investigated. Our aim was to evaluate the use and impact of pre-implantation balloon aortic valvuloplasty (pre-BAV) before transcatheter aortic valve implantation (TAVI) with Acurate neo. The NEOPRO Registry retrospectively included 1,263 patients who underwent transfemoral TAVI with Acurate neo at 18 centers between January 2012 and March 2018. Information on pre-BAV was available for 1,262 patients (99.9%). Primary end points were pre-discharge moderate-to-severe paravalvular aortic regurgitation (PAR II+), 30-day new permanent pacemaker implantation, and 30-day all-cause mortality or stroke. A total of 1,262 patients who underwent TAVI with (n = 1,051) or without predilatation (n = 211) were included. A reduction in the pre-BAV rate was observed during the study period (from 95.7% in the first date quintile to 78.4% in the last date quintile). Patients who underwent pre-BAV had higher degrees of aortic valve (AV) and left ventricular outflow tract (LVOT) calcification. Primary endpoints were similar between pre-BAV and no pre-BAV groups (PAR II+ 5.5% vs 3.4%, p = 0.214; 30-day permanent pacemaker implantation 9.0% vs 8.0%, p = 0.660; 30-day death or stroke 4.9% vs 4.4%, p = 0.743). The need for postdilatation and other procedural outcomes were comparable between groups. Predilatation did not have a significant impact on primary endpoints across AV and LVOT calcification subgroups (subgroup analyses) and was not independently associated with primary endpoints (multivariate analyses). In conclusion, transfemoral Acurate neo implantation without predilatation appears to be feasible and safe, especially in patients with milder degrees of AV and LVOT calcification.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/instrumentação , Dilatação/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Masculino , Período Pré-Operatório , Sistema de Registros , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA