1.
Rep Pract Oncol Radiother ; 28(5): 671-680, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38179286

RESUMO

Background: The quality of treatment planning for stage III non-small cell lung cancer varies within and between facilities due to the different professions involved in planning. Dose estimation parameters were calculated using a feasibility dose-volume histogram (FDVH) implemented in the treatment planning quality assurance software PlanIQ. This study aimed to evaluate differences in treatment planning between occupations using manual FDVH-referenced treatment planning to identify their characteristics. Materials and methods: The study included ten patients with stage III non-small cell lung cancer, and volumetric-modulated arc therapy was used as the treatment planning technique. Fifteen planners, comprising five radiation oncologists, five medical physicists, and five radiological technologists, developed treatment strategies after referring to the FDVH. Results: Medical physicists had a higher mean dose at D98% of the planning target volume (PTV) and a lower mean dose at D2% of the PTV than those in other occupations. Medical physicists had the lowest irradiation lung volumes (V5 Gy and V13 Gy) compared to other professions, and radiation oncologists had the lowest V20 Gy and mean lung dose. Radiological technologists had the highest irradiation volumes for dose constraints at all indexes on the normal lung volume. Conclusions: The quality of the treatment plans developed in this study differed between occupations due to their background expertise, even when an FDVH was used as a reference. Therefore, discussing and sharing knowledge and treatment planning techniques among professionals is essential to determine the optimal treatment plan for each facility and patient.

2.
Rep Pract Oncol Radiother ; 27(6): 963-972, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36632304

RESUMO

Background/Aim: The more complex the treatment plan, the higher the possibility of errors in dose verification. Recently, a treatment planning quality assurance (QA) software (PlanIQ) with a function to objectively evaluate the quality of volumetric-modulated arc therapy (VMAT) treatment plans by scoring and calculating the ideal dose-volume histogram has been marketed. This study aimed to assess the association between the scores of ideal treatment plans identified using PlanIQ and the results of dose verification and to investigate whether the results of dose verification can be predicted based on the complexity of treatment plans. Materials and methods: Dose verification was performed using an ionization chamber dosimeter, a radiochromic film, and a three-dimensional dose verification system, Delta4 PT. Correlations between the ideal treatment plan scores obtained by PlanIQ and the results of the absolute dose verification and dose distribution verification were obtained, and it was examined whether dose verifications could be predicted from the complexity of the treatment plans. Results: Even when the score from the ideal treatment plan was high, the results of absolute dose verification and dose distribution verification were sometimes poor. However, even when the score from the ideal treatment plan was low, the absolute volume verification and dose distribution verification sometimes yielded good results. Conclusions: Treatment plan complexity can be determined in advance from the ideal treatment plan score calculated by PlanIQ. However, it is difficult to predict the results of dose verification using an ideal treatment plan.

3.
J Appl Clin Med Phys ; 18(4): 69-75, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28574221

RESUMO

Stereotactic body radiation therapy (SBRT) involves the delivery of substantially larger doses over fewer fractions than conventional therapy. Therefore, SBRT treatments will strongly benefit patients using vivo patient dose verification, because the impact of the fraction is large. For in vivo measurements, a commercially available quality assurance (QA) system is the COMPASS system (IBA Dosimetry, Germany). For measurements, the system uses a new transmission detector (Dolphin, IBA Dosimetry). In this study, we evaluated the method for in vivo 3D dose reconstruction for SBRT using this new transmission detector. We confirmed the accuracy of COMPASS with Dolphin for SBRT using multi leaf collimator (MLC) test patterns and clinical SBRT cases. We compared the results between the COMPASS, the treatment planning system, the Kodak EDR2 film, and the Monte Carlo (MC) calculations. MLC test patterns were set up to investigate various aspects of dose reconstruction for SBRT: (a) simple open fields (2 × 2-10 × 10 cm2 ), (b) a square wave chart pattern, and (c) the MLC position detectability test in which the MLCs were changed slightly. In clinical cases, we carried out 6 and 8 static IMRT beams for SBRT in the lung and liver. For MLC test patterns, the differences between COMPASS and MC were around 3%. The COMPASS with the dolphin system showed sufficient resolution in SBRT. For clinical cases, COMPASS can detect small changes for the dose profile and dose-volume histogram. COMPASS also showed good agreement with MC. We can confirm the feasibility of SBRT QA using the COMPASS system with Dolphin. This method was successfully operated using the new transmission detector and verified by measurements and MC.


Assuntos
Processamento de Imagem Assistida por Computador/instrumentação , Radiocirurgia/instrumentação , Dosagem Radioterapêutica , Humanos , Processamento de Imagem Assistida por Computador/métodos , Método de Monte Carlo , Radiometria/instrumentação , Radiocirurgia/métodos , Radiocirurgia/normas , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada
4.
Artigo em Japonês | MEDLINE | ID: mdl-28428474

RESUMO

Recently, intensity-modulated radiation therapy (IMRT) is used worldwide, highly accurate verification of the location using image-guided radiation therapy (IGRT) has become critical. However, the use of cone-beam computed tomography (CBCT) to ascertain the location each time raises concerns about its influence on radiotherapy dosage and increased radiation exposure. The purpose of this study was to measure the absorbed dose using nine kilovoltage (kV) devices and two megavoltage (MV) devices (total 11 devices) at eight facilities, compare the absorbed dose among the devices, and assess the characteristics of the respective devices to ensure optimal clinical operation. For the measurement of the absorbed dose, a farmer-type ionization chamber dosimeter, calibrated using a 60Co and an IMRT dose verification phantom manufactured from water-equivalent material RW3, was used to measure the absorbed dose at nine points in the phantom for two regions, the pelvic and cephalic region. The average absorbed dose of the pelvic region was 3.09±0.21 cGy in kV-CBCT (OBI), 1.16±0.16 cGy in kV-CBCT (XVI), 5.64±1.48 cGy in MV-CBCT (4 MV), and 6.33±1.54 cGy in MV-CBCT (6 MV). The average absorbed dose of the cephalic region was 0.38±0.03 cGy in kV-CBCT (OBI), 0.23±0.06 cGy in kV-CBCT (XVI), 4.02±0.72 cGy in MV-CBCT (4 MV), and 4.46±0.77 cGy in MV-CBCT (6 MV). There was a difference in the absorbed dose at the measured points as well as in the dose distribution in the phantom cross section. No major difference was observed in the absorbed dose among identical devices, but a difference was identified among the devices installed at multiple facilities. Therefore, the angle of rotation should be paid attention to when CBCT is taken, and the image-taking conditions should be determined. In addition, it is important to handle the devices only after ascertaining the absorbed dose of each device.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Radioterapia Guiada por Imagem/métodos , Calibragem , Tomografia Computadorizada de Feixe Cônico/instrumentação , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
5.
J Appl Clin Med Phys ; 16(1): 5199, 2015 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-25679177

RESUMO

In this study, we evaluated the performance of a three-dimensional (3D) dose verification system, COMPASS version 3, which has a dedicated beam models and dose calculation engine. It was possible to reconstruct the 3D dose distributions in patient anatomy based on the measured fluence using the MatriXX 2D array. The COMPASS system was compared with Monte Carlo simulation (MC), glass rod dosimeter (GRD), and 3DVH, using an anthropomorphic phantom for intensity-modulated radiation therapy (IMRT) dose verification in clinical neck cases. The GRD measurements agreed with the MC within 5% at most measurement points. In addition, most points for COMPASS and 3DVH also agreed with the MC within 5%. The COMPASS system showed better results than 3DVH for dose profiles due to individual adjustments, such as beam modeling for each linac. Regarding the dose-volume histograms, there were no large differences between MC, analytical anisotropic algorithm (AAA) in Eclipse treatment planning system (TPS), 3DVH, and the COMPASS system. However, AAA underestimated the dose to the clinical target volume and Rt-Parotid slightly. This is because AAA has some problems with dose calculation accuracy. Our results indicated that the COMPASS system offers highly accurate 3D dose calculation for clinical IMRT quality assurance. Also, the COMPASS system will be useful as a commissioning tool in routine clinical practice for TPS.


Assuntos
Imageamento Tridimensional/métodos , Neoplasias/radioterapia , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Software , Humanos , Processamento de Imagem Assistida por Computador/métodos , Método de Monte Carlo , Aceleradores de Partículas , Radiometria/métodos , Dosagem Radioterapêutica
6.
J Appl Clin Med Phys ; 16(2): 5226, 2015 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-26103194

RESUMO

The purpose of this study was to evaluate a single-scan protocol using Gafchromic EBT3 film (EBT3) by comparing it with the commonly used 24-hr measurement protocol for radiochromic film dosimetry. Radiochromic film is generally scanned 24 hr after film exposure (24-hr protocol). The single-scan protocol enables measurement results within a short time using only the verification film, one calibration film, and unirradiated film. The single-scan protocol was scanned 30 min after film irradiation. The EBT3 calibration curves were obtained with the multichannel film dosimetry method. The dose verifications for each protocol were performed with the step pattern, pyramid pattern, and clinical treatment plans for intensity-modulated radiation therapy (IMRT). The absolute dose distributions for each protocol were compared with those calculated by the treatment planning system (TPS) using gamma evaluation at 3% and 3 mm. The dose distribution for the single-scan protocol was within 2% of the 24-hr protocol dose distribution. For the step pattern, the absolute dose discrepancies between the TPS for the single-scan and 24-hr protocols were 2.0 ± 1.8 cGy and 1.4 ± 1.2 cGy at the dose plateau, respectively. The pass rates were 96.0% for the single-scan protocol and 95.9% for the 24-hr protocol. Similarly, the dose discrepancies for the pyramid pattern were 3.6 ± 3.5cGy and 2.9 ± 3.3 cGy, respectively, while the pass rates for the pyramid pattern were 95.3% and 96.4%, respectively. The average pass rates for the four IMRT plans were 96.7% ± 1.8% for the single-scan protocol and 97.3% ± 1.4% for the 24-hr protocol. Thus, the single-scan protocol measurement is useful for dose verification of IMRT, based on its accuracy and efficiency.


Assuntos
Dosimetria Fotográfica/métodos , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Calibragem , Protocolos Clínicos , Dosimetria Fotográfica/instrumentação , Humanos , Masculino , Dosagem Radioterapêutica
9.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 70(11): 1311-7, 2014 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-25410339

RESUMO

PURPOSE: Although image-guided radiotherapy (IGRT) is widely used to determine and correct daily setup errors, the additional interpretation for image registration would provide another error. We evaluated the uncertainty in image registration in IGRT. METHOD: The subjects consisted of 12 consecutive patients treated with IGRT for thoracic esophageal cancer. Two radiation therapists had consensually achieved daily 3D registration between planning computed tomography (CT) and cone beam CT (CBCT). The original data sets of image registration in all fractions except for boost irradiations with a change in the isocenter positions were selected for evaluation. There were 20 to 32 data sets for each patient: a total of 318 data sets. To evaluate daily setup errors, the mean 3D displacement vector was calculated for each patient. To assess the reproducibility of image registration, two other radiation therapists reviewed the data sets and recorded geometric differences as uncertainty in the image registration. RESULTS: The mean 3D displacement vector for each patient ranged from 4.9 to 15.5 mm for setup errors and 0.7 to 2.2 mm for uncertainty in image registration. There was a positive correlation between the 3D vectors for setup error and uncertainty in image registration (r = 0.487, p = 0.016). CONCLUSION: Although IGRT can correct the setup errors, potential uncertainty exists in image registration. The setup error would disturb the image registration in IGRT.


Assuntos
Neoplasias Esofágicas/diagnóstico por imagem , Radiografia Torácica/métodos , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Incerteza
10.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 70(1): 34-40, 2014 Jan.
Artigo em Japonês | MEDLINE | ID: mdl-24464062

RESUMO

PURPOSE: We developed a quality assurance (QA) phantom to enable easy confirmation of radiation source output measurements of a high dose rate (192)Ir intracavitary brachytherapy unit in gynecology. The purpose of this study was to evaluate the feasibility of daily checks using the QA phantom. METHODS AND MATERIALS: The QA phantom was designed with tough water phantoms to hold a Farmer-type ionization chamber, with semiconductor detectors used as in vivo dosimeters to measure rectal dose, and three transfer tubes for gynecology. To test the reliability of our QA phantom for the detection of abnormalities in source output or semiconductor detectors, we applied different doses. RESULTS: Variations due to different settings of the QA phantom were within 2%. The temporal variations were less than 2% and 5% in the Farmer-type ionization chamber and semiconductor detectors, respectively. Interobserver variations were below 3%. CONCLUSIONS: With tolerance levels of 2% and 5% for a Farmer-type ionization chamber and semiconductor detectors, respectively, a QA phantom is potentially useful for easily detecting abnormalities by applying daily checks of the brachytherapy unit.


Assuntos
Braquiterapia/normas , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Doses de Radiação , Radiometria/métodos , Feminino , Doenças dos Genitais Femininos/radioterapia , Humanos , Radiometria/instrumentação
11.
Radiol Phys Technol ; 17(1): 337-345, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37938420

RESUMO

This study devised a method to efficiently launch the RapidPlan model for volumetric-modulated arc therapy for prostate cancer in small- and medium-sized facilities using high-quality treatment plans with the PlanIQ software as a reference. Treatment plans were generated for 30 patients with prostate cancer to construct the RapidPlan model using PlanIQ as a reference. In the context of PlanIQ-referenced treatment planning, treatment plans were developed, such that the feasibility dose-volume histogram of each organ-at-risk fell within F ≤ 0.1. For validation of the RapidPlan model, treatment plans were formulated for 20 patients using both RapidPlan and PlanIQ, and the differences were evaluated. The results of RapidPlan model validity assessment revealed that the RapidPlan-produced treatment plans exhibited higher quality in 11 of 20 patients. No significant differences were found between the treatment plans. In conclusion, high-quality treatment plans formulated using PlanIQ as reference facilitated efficient implementation of RapidPlan modeling.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Masculino , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Software , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Órgãos em Risco
12.
Med Dosim ; 49(3): 271-275, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38556402

RESUMO

The increase in high-precision radiation therapy, particularly volumetric-modulated arc therapy (VMAT), has increased patient numbers and expanded treatment sites. However, a significant challenge in VMAT treatment planning is the inconsistent plan quality among different planners and facilities. This study explored the use of dose-volume histogram (DVH) prediction tools to address these disparities, specifically focusing on RapidPlan (Varian Medical Systems) and PlanIQ (Sun Nuclear). RapidPlan predicts achievable DVHs and automatically generates optimization objectives. While it has demonstrated organ-at-risk (OAR) dose reduction benefits, the quality of the plan used to build its model significantly affects its predictions. On the other hand, PlanIQ offers ease of use and does not require prior model-building. Five planners participated in this study, each creating two treatment plans: one referencing RapidPlan and the other using PlanIQ. The planners had the freedom to adjust parameters while referencing the DVH predictions. The plans were evaluated using "Plan Quality Metric" (PQM) scores to assess the planning target volume excluding the rectum and OARs. The results revealed that RapidPlan-referenced plans often outperformed PlanIQ-based plans, with less interplanner variability. PlanIQ played a pivotal role in the construction of the RapidPlan model. This study is the first to compare plans generated by multiple planners using both tools. This study provides insights into optimizing treatment planning by considering the characteristics of both RapidPlan and PlanIQ.


Assuntos
Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Órgãos em Risco
13.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 69(7): 753-60, 2013 Jul.
Artigo em Japonês | MEDLINE | ID: mdl-23877153

RESUMO

Image-guided radiotherapy (IGRT) is an increasingly commonly adopted technique. As a result, however, total patient dose is increasing rapidly, especially when kV-cone beam computed tomography (CBCT) is applied. This study investigated the dosimetry of kV-CBCT using a Farmer ionization chamber with a (60)Co absorbed-dose calibration factor. The absorbed-dose measurements were performed using an I'mRT phantom (RW3, IBA) which is employed for dose verification of intensity-modulated radiotherapy (IMRT). The I'mRT phantom was used as a substitute for head and pelvis phantoms. The kV-CBCT absorbed dose was evaluated from a beam quality conversion factor of kV to (60)Co and the ionization ratio of the I'mRT phantom and water, calculated using the Monte Carlo method. The dose distribution in the I'mRT phantom was also measured using a radiophotoluminescent glass dosimeter (RGD). The absorbed doses for the pelvis phantom (full scan) ranged from 2.5-4 cGy for kV-CBCT and 4-8 cGy for MV-CBCT. TomoTherapy resulted in a lower dose of approximately 1.3 cGy due to fan-beam. For the head phantom (half scan), the doses ranged from 0.1-0.7 cGy for kV-CBCT and 3-5 cGy for MVCBCT. The results for RGD were similar to ion chamber measurements. It is necessary to decrease the absorbed dose of the organs at risk every time IGRT is applied.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Radiometria/métodos , Radioterapia Guiada por Imagem/métodos , Cabeça , Humanos , Método de Monte Carlo , Pelve , Imagens de Fantasmas
14.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 69(7): 778-83, 2013 Jul.
Artigo em Japonês | MEDLINE | ID: mdl-23877156

RESUMO

In this article, we present a physical characterization of the agility(™) (Elekta). agility(™) is composed of 160 interdigitating multileaf collimators (MLCs) with a width of 5 mm at the isocenter. The physical characterizations that include leaf position accuracy, leakage, field penumbra and the tongue-and-groove (T&G) effect were evaluated using well-commissioned 4, 6 and 10-MV photon beams. The leaf position accuracy was within 0.5 mm for all gantry angles and each MLC. The leakage was 0.44% on average and reached 0.47% at 10 MV: remarkably low due to a new design with tilted leaves. However, the T&G effect occurred due to tilt. It was approximately 20.8% on average and reached 22.3% at 6 MV. The penumbra width increased up to 8.5 mm at a field size of 20×20 cm at 4 MV. High position designed MLCs create a wider penumbra but show lower leakage and large head clearance. Head clearance is an important factor in stereotactic radiotherapy with multiple non-coplanar beams.


Assuntos
Radioterapia Conformacional/instrumentação , Desenho de Equipamento , Planejamento da Radioterapia Assistida por Computador
15.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 69(7): 761-72, 2013 Jul.
Artigo em Japonês | MEDLINE | ID: mdl-23877154

RESUMO

At present, every manufacturer of intensity modulated radiation therapy (IMRT) equipment uses multi-leaf collimators (MLCs); however, each company's intensity modulation methods and dose calculation algorithms differ. This study used four typical radiation treatment planning systems (RTPSs) employed domestically for prostate IMRT plans to carry out 15 case studies by one planner based on the dose limits at this clinic. The results were used to compare the differences, if any, in RTPS treatment plans. With prostate IMRT plans, an overlap area exists between the PTV and the rectum. For this reason, while observing dose limits of 60-75 Gy (within the dose tolerated by the rectum), securing uniformity and concentration of dose is essential to create the most appropriate treatment plan for the PTV and other targets. Although each RTPS uses different planning methods, it was generally possible to observe this clinic's dose limits by adjusting the parameter values. When identical beam data is used, it is possible to create similar treatment plans.


Assuntos
Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada , Algoritmos , Humanos , Masculino
17.
Artigo em Japonês | MEDLINE | ID: mdl-23089834

RESUMO

In this study, we evaluated various image guided radiation therapy (IGRT) systems regarding accuracy and patient throughput for conventional radiation therapy. We compared between 2D-2D match (the collation by 2 X-rays directions), cone beam computed tomography (CBCT), and ExacTrac X-Ray system using phantom for CLINAC iX and Synergy. All systems were able to correct within almost 1 mm. ExacTrac X-Ray system showed in particular a high accuracy. As for patient throughput, ExacTrac X-Ray system was the fastest system and 2D-2D match for Synergy was the slowest. All systems have enough ability with regard to accuracy and patient throughput on clinical use. ExacTrac X-Ray system showed superiority with accuracy and throughput, but it is important to note that we have to choose the IGRT technique depending on the treatment site, the purpose, and the patient's state.


Assuntos
Radioterapia Guiada por Imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Imagens de Fantasmas , Radioterapia Guiada por Imagem/normas
18.
Jpn J Clin Oncol ; 41(4): 503-7, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21233103

RESUMO

OBJECTIVE: To evaluate longitudinal changes in parotid volumes and saliva production over 2 years after 30 Gy irradiation. METHODS: We retrospectively evaluated 15 assessable patients treated for advanced oral cancer. Eligibility criteria were a pathologic diagnosis of squamous cell carcinoma, preoperative radiation therapy with a total dose of 30 Gy delivered in 15 fractions, and the availability of longitudinal data of morphological assessments by computed tomography and functional assessments with the Saxon test spanning 2 years after radiation therapy. In the Saxon test, saliva production was measured by weighing a folded sterile gauze pad before and after chewing; the low-normal value is 2 g/2 min. Repeated-measures analysis of variance with Bonferroni adjustment for multiple comparisons was used to determine the longitudinal changes. RESULTS: The normalized ipsilateral parotid volumes 2 weeks and 6-, 12- and 24 months after radiation therapy were found to be 72.5, 63.7, 66.9 and 78.1%, respectively; the normalized contralateral volumes were 69.8, 64.6, 72.2 and 82.0%, respectively. The bilateral parotid volumes were significantly decreased after radiation therapy (P < 0.01). The nadir appeared at 6 months post-radiation therapy and the volumes substantially recuperated 24 months after radiation therapy (P < 0.01). Mean saliva production before radiation therapy was 3.7 g; the longitudinal changes after radiation therapy were 31.3, 38.0, 43.3 and 69.6%, respectively. Substantial recuperation of saliva production was observed 24 months after radiation therapy (P = 0.01). CONCLUSIONS: Although parotid volumes and saliva production were decreased after 30 Gy irradiation, we observed the recuperation of morphological and functional changes in the parotid glands 2 years after radiation therapy.


Assuntos
Carcinoma de Células Escamosas/radioterapia , Neoplasias Bucais/radioterapia , Terapia Neoadjuvante/métodos , Glândula Parótida/efeitos da radiação , Saliva/metabolismo , Saliva/efeitos da radiação , Xerostomia/etiologia , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/fisiopatologia , Carcinoma de Células Escamosas/cirurgia , Quimioterapia Adjuvante , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Bucais/diagnóstico por imagem , Neoplasias Bucais/patologia , Neoplasias Bucais/fisiopatologia , Neoplasias Bucais/cirurgia , Tamanho do Órgão/efeitos da radiação , Glândula Parótida/metabolismo , Glândula Parótida/patologia , Planejamento da Radioterapia Assistida por Computador , Radioterapia Adjuvante/efeitos adversos , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Xerostomia/patologia , Xerostomia/fisiopatologia
19.
Med Dosim ; 46(4): e1-e6, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33972163

RESUMO

INTRODUCTION: Software that evaluates the quality of treatment plans (PlanIQTM) has become commercially available in recent years. It includes a feasibility assessment tool that provides the ideal dose volume histogram (DVH) for each organ at risk, based on the ideal dose falloff from the prescribed dose at the target boundary. It is important to investigate whether the PlanIQTM assessment tool (Feasibility DVHTM) can assist treatment planners who have limited to no experience in treatment planning. Therefore, the present study aimed to evaluate this tool's usefulness for improving the quality of treatment plans. MATERIALS & METHODS: This study included 5 patients with prostate cancer. The treatment planners were 2 graduate students, 2 undergraduate students, and one clinical planner. All students were radiological technology and medical physics students with no clinical experience. Two different volumetric-modulated arc therapy (VMAT) plans were developed before and after Feasibility DVHTM. The quality of each treatment plan was evaluated based on a scoring system implemented in PlanIQTM. RESULTS: Of 5 patients included, 4 received improved treatment plans when Feasibility DVHTM was used. Moreover, 4 of 5 treatment planners showed improvement in treatment planning using Feasibility DVHTM. CONCLUSIONS: The findings suggest that using the Feasibility DVHTM tool may improve treatment plans for different planners and patients. However, planners at any level of experience should be trained to check the dose distribution in addition to checking the DVH, which depends on the adequacy of the contours.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Humanos , Masculino , Órgãos em Risco , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Software
20.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 66(4): 322-33, 2010 04 20.
Artigo em Japonês | MEDLINE | ID: mdl-20625219

RESUMO

The purpose of this study was to compare dose distributions from three different RTPS with those from Monte Carlo (MC) calculations and measurements, in heterogeneous phantoms for photon beams. This study used four algorithms for RTPS: AAA (analytical anisotropic algorithm) implemented in the Eclipse (Varian Medical Systems) treatment planning system, CC (collapsed cone) superposition from the Pinnacle (Philips), and MGS (multigrid superposition) and FFT (fast Fourier transform) convolution from XiO (CMS). The dose distributions from these algorithms were compared with those from MC and measurements in a set of heterogeneous phantoms. Eclipse/AAA underestimated the dose inside the lung region for low energies of 4 and 6 MV. This is because Eclipse/AAA do not adequately account for a scaling of the spread of the pencil (lateral electron transport) based on changes in the electron density at low photon energies. The dose distributions from Pinnacle/CC and XiO/MGS almost agree with those of MC and measurements at low photon energies, but increase errors at high energy of 15 MV, especially for a small field of 3x3 cm(2). The FFT convolution extremely overestimated the dose inside the lung slab compared to MC. The dose distributions from the superposition algorithms almost agree with those from MC as well as measured values at 4 and 6 MV. The dose errors for Eclipse/AAA are lager in lung model phantoms for 4 and 6 MV. It is necessary to use the algorithms comparable to superposition for accuracy of dose calculations in heterogeneous regions.