RESUMO
OBJECTIVES: The aim of this systematic review was to comprehensively explore the current trends and therapeutic approaches in which an operating microscope (OM) is used in periodontics and dental implant surgeries. MATERIALS AND METHODS: A systematic search strategy was built to detect studies including various surgical techniques performed under an OM. PubMed, EMBASE, and SCOPUS databases were searched. No limitations in terms of time and language were applied. The data regarding the study design, type of procedure, treatment groups, and surgical outcomes were collected and analyzed descriptively. In addition, a bibliometric analysis was performed concerning the co-authorship and keyword co-occurrence network. RESULTS: Out of 1985 articles, finally, 55 met the inclusion criteria. Current periodontal and implant microsurgery trends consist of: periodontal therapy, dental implant microsurgery, soft tissue grafting and periodontal plastic surgery, bone augmentation, ridge preservation, and ortho-perio microsurgery. The bibliometric analysis revealed "guided tissue regeneration", "periodontal regeneration" and "root coverage" being the most repeated keywords (landmark nodes). 132 authors within 29 clusters were identified, publishing within the frameworks of "periodontal and implant microsurgery". CONCLUSION: Within its limitations, this systematic review provides an overview of the latest trends in periodontal and implant microsurgery when considering the use of an OM as the magnification tool. Also, it discusses the reported success and outcomes of the mentioned procedures.
RESUMO
This prospective, preliminary controlled clinical trial investigates the comparative effectiveness of platform-switching (PS) versus traditional butt-joint or platform-matching (PM) implant-abutment connections on peri-implant crestal bone stability. Utilizing a split mouth design, 10 systemically healthy patients (n= 20 implants) had adjacent non-restorable maxillary anterior teeth replaced with two different implants (butt-joint connections and platform-switching interfaces). Patients underwent alveolar ridge preservation, followed by implant placement: platform-matching implants were inserted at crestal bone level, and platform-switching implants were placed 1mm subcrestally. Customized Zirconia crowns were then fabricated for both systems. Outcome measures included bleeding on probing (BOP), probing pocket depth (PPD), and marginal bone loss (MBL), which were evaluated through standardized periapical radiographs over 3-year timeframe. Results showed significantly higher initial MBL in the PM group (0.86 ± 0.13 mm) compared to the PS group (0.34±0.29 mm) [p value: p<0.01]. Moreover, at the three-year follow-up, the crestal bone levels remained above the implant shoulder until the third year of the study for the PS subcrestal group (PS: -0.15±0.39 mm) and slightly below the implant platform in the PM crestal group (PM: 0.55±0.19). After 3 years, the PS group also exhibited lower mean BOP percentages (12%) than the butt-joint group (17%). This study suggests that subcrestal placement with PS and internal connections can provide better long-term peri- implant bone preservation, thereby potentially improving implant success and aesthetic outcomes in the anterior maxillary region.
RESUMO
OBJECTIVE: To evaluate the feasibility of ultrasound-image-based computer-assisted implant planning and placement. MATERIALS AND METHODS: Intraoral scans, cone-beam computerized tomography (CBCT), and ultrasound (US) scans with a custom positioning device were acquired in nine patients. Prosthetic-driven surgical guides were planned and fabricated based on ultrasound images and intraoral scans. Implants were then placed. Postoperative implant position was obtained intra-surgically by intraoral scan. Aside from the ultrasound-based plan, conventional implant planning was performed by the same operator on a pre-surgical CBCT for comparison. Linear deviations between ultrasound and CBCT-planned implant positions were measured and compared with the intra-surgical implant position, and the position deviations between two consecutive plannings were performed on the same CBCT by the same operator. The linear deviation between the 3D scan surface of the edentulous region and the ultrasonographic soft tissue profile segmentation was also assessed with reverse-engineering software. Means, standard deviations, and root mean square differences (RMSD) were calculated for every variable. RESULTS: All the ultrasound-planned implants were successfully placed, and no complications were recorded. The mean deviations in angles, shoulders, and apexes were 5.27 ± 1.75° (RMSD: 5.53°), 0.92 ± 0.26 mm (RMSD: 0.95 mm), and 1.41 ± 0.61 mm (RMSD: 1.53 mm), respectively, between the US and CBCT-planned implants; 2.63 ± 0.43° (RMSD: 2.66°), 1.16 ± 0.30 mm (RMSD: 1.19 mm), and 1.26 ± 0.27 mm (RMSD: 1.28 mm) between the planned implant and intra-surgically recorded positions; and 2.90 ± 1.36° (RMSD: 3.18°), 0.65 ± 0.27 mm (RMSD: 0.70 mm), and 0.99 ± 0.37 mm (RMSD: 1.05 mm) between two consecutive CBCTs planning performed by the same operator. The mean deviation between the 3D surfaces of model scans and ultrasound-derived soft tissue profile in the edentulous area was 0.19 ± 0.08 mm. CONCLUSIONS: Ultrasound-guided implant surgery represents a feasible non-ionizing alternative to conventional static guided implant surgical protocols for implant placement in sites with favorable characteristics.
RESUMO
OBJECTIVE: To assess a newly developed intraoral scan protocol in enhancing the accuracy of complete-arch implant impressions. MATERIALS AND METHODS: Four impression approaches were applied to the same maxillary edentulous model with 6 implants: (1) intraoral scan (IOS), (2) intraoral scan with scan aid (IOS-SA), (3) calibrated intraoral scan protocol (CISP), and (4) conventional splinted open-tray impression (CONV). Each approach was repeated 10 times, and a direct scan of the model with a desktop scanner was used as a reference model. The alignment of scans and the reference model was conducted by two methods: (a) aligning all scan bodies to evaluate the overall fit, and (b) aligning the first and second scan bodies to simulate the Sheffield fit test for passive fitting of multiple implant-supported prostheses. Linear deviations from the reference model (trueness) and within each group (precision) were analyzed using Python scripts. RESULTS: When aligned by all scan bodies, the CISP group exhibited comparable mean trueness (38.33 µm) and precision (45.97 µm) to the CONV group (44.30 and 47.92 µm respectively), both of which significantly outperformed the IOS group (86.82 and 83.17 µm, respectively). Furthermore, in the virtual Sheffield fit test, the CISP group achieved the highest levels of mean trueness at the end span (121.7 µm), making a linear deviation reduction of 36.7%, 60%, and 41.4% when compared to the CONV, the IOS, and the IOS-SA groups, respectively. Moreover, the CISP group (104.3 µm) displayed a remarkable 65, 182, and 86 µm advantage in precision over the CONV, IOS, and IOS-SA groups, respectively. CONCLUSION: CISP demonstrated comparable accuracy to the gold standard, the conventional splinted open-tray impression. Furthermore, it excelled in the virtual passive fitting test.
Assuntos
Técnica de Moldagem Odontológica , Humanos , Modelos Dentários , Implantes Dentários , Calibragem , Prótese Dentária Fixada por Implante , Técnicas In Vitro , Maxila/diagnóstico por imagem , Arcada Edêntula/diagnóstico por imagemRESUMO
INTRODUCTION: Since its establishment in 1999, the journal of Clinical Implant Dentistry and Related Research (CIDRR) has consistently disseminated notable clinical and translational research within the domain of oral implantology. As the journal approaches its milestone 25th anniversary, this study endeavors to systematically delineate the publication trends, level of evidence, and bibliometric indices characterizing the initial quarter-century of CIDRR's scholarly activity. Notably, the investigation adopts a contemporary methodology by incorporating Altmetric analysis, thereby enriching the evaluation with an assessment of the broader societal and online impact of the published research. METHODS: A comprehensive search was performed in SCOPUS and PubMed to access the bibliographic data of all articles published in the journal from 1999 to 2024. Additionally, Altmetric database was used to obtain social media attention scores (AAS). Journal's overall performance via impact factor and quartile range was assessed. Most cited papers were identified and the most prolific authors, institutions and countries and the collaboration networks among those were assessed. The level of evidence of all articles was determined based on Oxford level of evidence scale. All articles were categorized based on their major topic in the field of implant dentistry. RESULTS: Throughout its first 25 years of activity, CIDRR published 1912 articles with an annual growth rate of 2.67% and consistently being ranked at Q1 quartile in "Dentistry (miscellaneous)" and "Oral Surgery" journal categories. When clinical studies are considered, level I and II evidence constituted 22.82% and 11.82% of all articles, respectively. Sweden, the USA, and Italy as well as Göteborgs Universitet, Sahlgrenska Akademin. and Malmö Högskola were the most prolific countries and institutions respectively. "Implant system/design/characteristics," "Bone Augmentation," and "Implant Prosthesis" were the top most investigated topics. CONCLUSIONS: The examination of the journal's initial 25 years highlighted that CIDRR has surpassed similar dental research journals in publishing a greater number of high-level evidence articles. It also showcased diverse country- and author-collaboration networks. However, the journal's social media presence is still evolving. This article, presenting a comprehensive overview of the journal's scientometric and bibliographic activities, serves as a valuable reference for researchers, clinicians, and stakeholders, offering insights into both traditional and contemporary perspectives.