RESUMO
Idiopathic scoliosis (IS) is a three-dimensional rotation of the spine >10 degrees with an unknown etiology. Our laboratory established a late-onset IS model in zebrafish (Danio rerio) containing a deletion in kif7. A total of 25% of kif7co63/co63 zebrafish develop spinal curvatures and are otherwise developmentally normal, although the molecular mechanisms underlying the scoliosis are unknown. To define transcripts associated with scoliosis in this model, we performed bulk mRNA sequencing on 6 weeks past fertilization (wpf) kif7co63/co63 zebrafish with and without scoliosis. Additionally, we sequenced kif7co63/co63, kif7co63/+, and AB zebrafish (n = 3 per genotype). Sequencing reads were aligned to the GRCz11 genome and FPKM values were calculated. Differences between groups were calculated for each transcript by the t-test. Principal component analysis showed that transcriptomes clustered by sample age and genotype. kif7 mRNA was mildly reduced in both homozygous and heterozygous zebrafish compared to AB. Sonic hedgehog target genes were upregulated in kif7co63/co63 zebrafish over AB, but no difference was detected between scoliotic and non-scoliotic mutants. The top upregulated genes in scoliotic zebrafish were cytoskeletal keratins. Pankeratin staining of 6 wpf scoliotic and non-scoliotic kif7co63/co63 zebrafish showed increased keratin levels within the zebrafish musculature and intervertebral disc (IVD). Keratins are major components of the embryonic notochord, and aberrant keratin expression has been associated with intervertebral disc degeneration (IVDD) in both zebrafish and humans. The role of increased keratin accumulation as a molecular mechanism associated with the onset of scoliosis warrants further study.
Assuntos
Disco Intervertebral , Escoliose , Animais , Humanos , Escoliose/genética , Peixe-Zebra/genética , Peixe-Zebra/metabolismo , Queratinas , Proteínas Hedgehog , Cinesinas/genética , Cinesinas/metabolismoRESUMO
CASE: This report details the cases of 2 older male patients with ankylosing spondylitis (AS) who presented with lumbar spinal stenosis at a single residual mobile segment and were treated with decompression without fusion. Both patients presented with severe symptoms in their lower limbs and opted to proceed with surgery. CONCLUSION: With autofusion above and below their single, stable mobile segment, decompression without fusion was a safe and effective procedure. A Coflex device was implanted in 1 patient. After successful surgery, both patients experienced significantly decreased symptoms.
Assuntos
Fusão Vertebral , Estenose Espinal , Espondilite Anquilosante , Adulto , Descompressão Cirúrgica/métodos , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Masculino , Fusão Vertebral/métodos , Estenose Espinal/cirurgia , Espondilite Anquilosante/complicações , Espondilite Anquilosante/cirurgiaRESUMO
BACKGROUND: Current evidence suggests placement of the Superion interspinous spacer (SISS) device compared with laminectomy or laminotomy surgery offers an effective, less invasive treatment option for patients with symptomatic lumbar spinal stenosis. Both SISS placement and laminectomy or laminotomy have risks of complications and a direct comparison of complications between the 2 procedures has not been previously studied. The purpose of this study is to compare the short-term complications of the SISS with laminectomy or laminotomy and highlight device-specific long-term outcomes with SISS. METHODS: Via retrospective review, 189 patients who received lumbar level SISSs were compared with 378 matched controls who underwent primary lumbar spine laminectomy or laminotomy; data were collected from the American College of Surgeons National Surgical Quality Improvement Program database. Complications analyzed included rates of wound infection, pulmonary embolism, deep venous thrombosis, urinary tract infection, sepsis, septic shock, cardiac arrest, death, and reoperation within 30 days of index surgery. Differences between groups were analyzed using the χ2test. Device-specific complication (DSC) rates included device malfunction or misplacement (DM), device explantation (DE), spinous process fracture (SPF), and subsequent spinal surgery (SSS). RESULTS: No differences in demographics or comorbidities existed between groups. There was no significant difference in rates of complications between groups. A total of 44.4% of patients in the SISS group experienced DSCs with 11.1% of patients experiencing DM, 21.1% experiencing an SPF, 20.1% requiring DE, and 24.3% requiring SSS. Having at least 1 DSC significantly increased odds of SSS, odds ratio >120, P < .0001. CONCLUSION: Rates of 30-day complications in the SISS group were not significantly different from patients undergoing laminectomy or laminotomy. Rates of 2-year DSC within SISS and cumulative risk associated with these complications should be considered further as they likely represent need for additional procedures for patients and substantial cost to the healthcare system. LEVEL OF EVIDENCE: 4. CLINICAL RELEVANCE: Having no differences in adverse events between laminectomies or laminotomies and SISS plus evidence of substantial device-specific long-term adverse outcomes and reoperation should be given consideration when deciding on surgical intervention of 1-2 level lumbar spinal stenosis.
RESUMO
BACKGROUND: Recent studies support the need for sagittal alignment restoration when performing lumbar degenerative spinal fusions. The development of patient-specific spine rods (PSSRs) may help maintain or improve sagittal alignment in these surgeries. METHODS: A retrospective review was conducted for patients who underwent posterior spinal surgeries involving 4 or less levels. The preplanned PSSR radii of curvature (ROC) was compared with standard prebent rods with a ROC of 125 mm. All surgeries were performed at a single institution by 3 surgeons from September 2016 through October 2018. Data were then compared using a 2-tailed paired t test. PSSR had either 1 or 2 definitive ROCs. RESULTS: For rods with 2 ROCs, the "cranial" curve was measured between the upper instrumented level and L4 or L5. The "caudal" curve was measured between L4 or L5 and the lower instrumented level. The PSSR with 1 ROC and the caudal portion of the rods with 2 ROCs were significantly smaller than the industry standard ROC. CONCLUSIONS: PSSR demonstrate more acute ROC than industry standard rods. In PSRs, the most lordosis occurs between L4-S1 and flattens out at the thoracolumbar junction, mimicking the normal distribution of lumbar lordosis. PSSRs could help achieve or maintain sagittal alignment and prevent the sequela of flat back syndrome.
RESUMO
The number of cannabis users increased up to 188 million users worldwide in 2017. Smoking and vaping are the most common consumption routes with formation of side-stream smoke/vapor and secondhand exposure to cannabinoids has been described in the literature. External contamination of hair by cannabis smoke has been studied but there are no studies on third-hand cannabis exposure due to deposition of smoke or vapor on surfaces. We tested whether cannabinoids could be detected on surfaces and objects in a room where cannabis is vaporized. Surface samples were collected using isopropanol imbued non-woven wipes from hard surfaces and objects. Each surface was swabbed three times with standardized swabbing protocol including three different patterns. Samples were analyzed using LC-ESI-MS/MS in combination with online extraction. THC was detected on 6 samples out of the 15 collected in the study room at quantifiable levels ranging 348-4882 ng/m2. Negative control samples collected from areas outside the study room were all negative. We demonstrated that surfaces exposed to side-stream cannabis vapor are positive for THC at quantifiable levels. This study represents a first step in understanding how side-stream cannabis vapor deposits in the environment and potentially results in a tertiary exposure for users and non-users.