Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Nano Lett ; 13(1): 131-6, 2013 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-23244683

RESUMO

We report the direct measurement of the Dirac point, the Fermi level, and the work function of graphene by performing internal photoemission measurements on a graphene/SiO(2)/Si structure with a unique optical-cavity enhanced test structure. A complete electronic band alignment at the graphene/SiO(2)/Si interfaces is accurately established. The observation of enhanced photoemission from a one-atom thick graphene layer was possible by taking advantage of the constructive optical interference in the SiO(2) cavity. The photoemission yield was found to follow the well-known linear density-of-states dispersion in the vicinity of the Dirac point. At the flat band condition, the Fermi level was extracted and found to reside 3.3 eV ± 0.05 eV below the bottom of the SiO(2) conduction band. When combined with the shift of the Fermi level from the Dirac point, we are able to ascertain the position of the Dirac point at 3.6 eV ± 0.05 eV with respect to the bottom of the SiO(2) conduction band edge, yielding a work function of 4.5 eV ± 0.05 eV which is in an excellent agreement with theory. The accurate determination of the work function of graphene is of significant importance to the engineering of graphene-based devices, and the measurement technique we have advanced in this Letter will have significant impact on numerous applications for emerging graphene-like 2-dimensional material systems.

2.
Int J Tuberc Lung Dis ; 27(4): 322-328, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-37035979

RESUMO

BACKGROUND: TB control remains a serious public health problem, compounded by poor treatment adherence, which increases the likelihood of onward transmission. We evaluated the effectiveness of medication event reminder monitoring (MERM) upon treatment adherence in a high TB burden setting.METHODS: We conducted an open-label parallel group randomised controlled trial among pulmonary TB adults. Participants were provided with a MERM device to store their medications. In the intervention arm, the devices were set to provide daily medication intake reminders. Primary outcome was the proportion of patient-months in which at least 6/30 doses were missed. Secondary outcomes included 1) the proportion of patient-months in which at least 14/30 doses were missed, and 2) the proportion of doses missed.RESULTS: Of 2,142 patients screened, 798 (37.3%) met the inclusion criteria and 250 participants were enrolled. The mean ratio (MR) for poor adherence between the intervention and control groups was 0.72 (95% CI 0.55-0.86). The intervention was also associated with a reduction in the proportion of patients missing at least 14/30 doses (MR 0.61, 95% CI 0.54-0.68) and the percentage of total doses missed (MR 0.75, 95% CI 0.68-0.80).CONCLUSION: MERM is effective in improving TB treatment adherence in a resource-limited environment.


Assuntos
Adesão à Medicação , Tuberculose Pulmonar , Adulto , Humanos , Sistemas de Alerta , Tuberculose Pulmonar/tratamento farmacológico , Monitoramento de Medicamentos
3.
Int J Tuberc Lung Dis ; 24(9): 934-940, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33156761

RESUMO

OBJECTIVE: To compare two community screening tests for TB: sputum examination using Xpert® MTB/RIF and chest radiography (CXR).METHOD: Men aged ≥15 years and women aged >45 years living in 96 sub-communes in Ca Mau, Viet Nam, were invited to provide a single sputum specimen that was tested using Xpert. Participants were also invited to attend a nearby location for digital radiography. Participants whose sputum was Xpert MTB-positive or whose CXR was reported as 'consistent with TB´ were requested to provide two further sputum specimens for culture. The sensitivities of the two tests for detecting TB (defined as sputum culture-positive for Mycobacterium tuberculosis) were compared.RESULTS: There were 72 985 eligible participants, of whom 57 597 (78.9%) participated in Xpert screening, 12 752 (17.5%) had CXR and 11 235 (15.4%) had both tests. We estimated that there were 59 cases of TB, of whom 20 were Xpert MTB-positive (programmatic sensitivity 34.0%) and 47 had CXR reported as 'consistent with TB´ (sensitivity 80.0%, P < 0.0001).CONCLUSION: In community-wide screening for TB, CXR is more sensitive than a single spontaneously expectorated sputum sample tested using Xpert, but it has a substantially lower participation rate.


Assuntos
Mycobacterium tuberculosis , Tuberculose Pulmonar , Tuberculose , Adolescente , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica , Radiografia , Sensibilidade e Especificidade , Escarro , Tuberculose Pulmonar/diagnóstico por imagem , Vietnã
5.
Clin Pharmacol Ther ; 102(2): 321-331, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28124478

RESUMO

Rifapentine is a highly active antituberculosis antibiotic with treatment-shortening potential; however, exposure-response relations and the dose needed for maximal bactericidal activity have not been established. We used pharmacokinetic/pharmacodynamic data from 657 adults with pulmonary tuberculosis participating in treatment trials to compare rifapentine (n = 405) with rifampin (n = 252) as part of intensive-phase therapy. Population pharmacokinetic/pharmacodynamic analyses were performed with nonlinear mixed-effects modeling. Time to stable culture conversion of sputum to negative was determined in cultures obtained over 4 months of therapy. Rifapentine exposures were lower in participants who were coinfected with human immunodeficiency virus, black, male, or fasting when taking drug. Rifapentine exposure, large lung cavity size, and geographic region were independently associated with time to culture conversion in liquid media. Maximal treatment efficacy is likely achieved with rifapentine at 1,200 mg daily. Patients with large lung cavities appear less responsive to treatment, even at high rifapentine doses.


Assuntos
Antibióticos Antituberculose/administração & dosagem , Antibióticos Antituberculose/farmacocinética , Rifampina/análogos & derivados , Tuberculose Pulmonar/tratamento farmacológico , Tuberculose Pulmonar/metabolismo , Adulto , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Rifampina/administração & dosagem , Rifampina/farmacocinética , Tuberculose Pulmonar/epidemiologia
6.
Rev Sci Instrum ; 86(11): 113903, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26628147

RESUMO

A metrology and data analysis protocol is described for high throughput determination of thermochromic metal-insulator phase diagrams for lightly substituted VO2 thin films. The technique exploits the abrupt change in near infrared optical properties, measured in reflection, as an indicator of the temperature- or impurity-driven metal-insulator transition. Transition metal impurities were introduced in a complementary combinatorial synthesis process for producing thin film libraries with the general composition space V(1-x-y)M(x)M'(y)O2, with M and M' being transition metals and x and y varying continuously across the library. The measurement apparatus acquires reflectance spectra in the visible or near infrared at arbitrarily many library locations, each with a unique film composition, at temperatures of 1 °C-85 °C. Data collection is rapid and automated; the measurement protocol is computer controlled to automate the collection of thousands of reflectance spectra, representing hundreds of film compositions at tens of different temperatures. A straightforward analysis algorithm is implemented to extract key information from the thousands of spectra such as near infrared thermochromic transition temperatures and regions of no thermochromic transition; similarly, reflectance to the visible spectrum generates key information for materials selection of smart window materials. The thermochromic transition for 160 unique compositions on a thin film library with the general formula V(1-x-y)M(x)M'(y)O2 can be measured and described in a single 20 h experiment. The resulting impurity composition-temperature phase diagrams will contribute to the understanding of metal-insulator transitions in doped VO2 systems and to the development of thermochromic smart windows.

7.
J Pediatr Surg ; 20(6): 747-53, 1985 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-4087105

RESUMO

Successful preservation of small bowel by cryobiologic techniques would increase the feasibility of intestinal transplants. Immunosuppression by Cyclosporin A (CyA) has also increased interest in intestinal transplantation. We have investigated the effect of cryopreservation and immunosuppression in fetal rat intestinal transplantation. Segments of fetal bowel implanted isogeneically into the paravertebral gutter of young rats were found to grow in a high percentage of animals (53% to 100%). Segments frozen to -20 degrees C or -40 degrees C at two rates of cooling, grew isogeneically (50% to 89%), demonstrating the feasibility of cryopreservation. Histologic examination of this bowel showed preservation of structure. When these segments were cooled and implanted allogeneically, no immunosuppressive effect was found. Segments protected by daily CyA administration grew. No synergistic effect was seen by associating CyA and cryopreservation. These experiments suggest the possibility of creating fetal small bowel long-term banking.


Assuntos
Ciclosporinas/administração & dosagem , Feto , Intestino Delgado/transplante , Preservação de Órgãos , Animais , Feminino , Feto/cirurgia , Congelamento , Terapia de Imunossupressão , Gravidez , Ratos , Ratos Endogâmicos , Fatores de Tempo , Transplante Isogênico
8.
ACS Appl Mater Interfaces ; 6(16): 14338-44, 2014 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-25075939

RESUMO

The electronic properties of solid-solid interfaces play critical roles in a variety of technological applications. Recent advances of film epitaxy and characterization techniques have demonstrated a wealth of exotic phenomena at interfaces of oxide materials, which are critically dependent on the alignment of their energy bands across the interface. Here we report a combined photoemission and electrical investigation of the electronic structures across a prototypical spinel/perovskite heterojunction. Energy-level band alignment at an epitaxial Co3O4/SrTiO3(001) heterointerface indicates a chemically abrupt, type I heterojunction without detectable band bending at both the film and substrate. The unexpected band alignment for this typical p-type semiconductor on SrTiO3 is attributed to its intrinsic d-d interband excitation, which significantly narrows the fundamental band gap between the top of the valence band and the bottom of the conduction band. The formation of the type I heterojunction with a flat-band state results in a simultaneous confinement of both electrons and holes inside the Co3O4 layer, thus rendering the epitaxial Co3O4/SrTiO3(001) heterostructure to be a very promising material for high-efficiency luminescence and optoelectronic device applications.

9.
J Assoc Off Anal Chem ; 67(6): 1102-4, 1984.
Artigo em Inglês | MEDLINE | ID: mdl-6520082

RESUMO

A gas chromatographic (GC) method is described to determine deoxynivalenol in wheat and corn at levels as low as 20 ppb. Ground samples are extracted with water, adsorbed onto a Clin Elut column, extracted with ethyl acetate, and passed through a silica gel Sep-Pak cartridge. The final extract is then derivatized with N-heptafluorobutyrylimidazole and quantitated by GC using an electron capture detector. Recoveries are greater than 85% for spiked samples at levels of 50-1000 ppb. Results for wheat, corn, and mixed feed samples are given as well as the results of an interlaboratory study on a naturally contaminated wheat sample.


Assuntos
Ração Animal/análise , Microbiologia de Alimentos , Micotoxinas/análise , Sesquiterpenos/análise , Tricotecenos/análise , Triticum/análise , Zea mays/análise , Fenômenos Químicos , Química , Cromatografia Gasosa/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA