RESUMO
OBJECTIVE: The purpose was to determine the growth rate of succinate dehydrogenase subunit (SDHx) gene-related paragangliomas based on computed tomography (CT) measurements. METHODS: Twenty-seven patients with SDHx mutations who underwent subsequent CT examinations were enrolled in the study. Tumors were classified as head and neck (HNP), thoracic, or abdominal/pelvic paragangliomas (PGLs). The percentage volume increase and volume doubling time were estimated. RESULTS: We analyzed 56 PGLs (21 with SDHD, 6 with SDHB mutations) in 27 patients (16 men, 11 women; mean age 37.7 years). The estimated median of the follow-up was 23 months. Twenty-two (39.3%) PGLs were located in the abdomen, 8 (14.3%) in the thorax, and 26 (46.4%) in the head and neck region. The median volume growth rate was estimated at 10.4% per year (interquartile range [IQR]: -1.3; 36.3). The volume doubling time was estimated as 7.01 (2.24;+∞) years. By tumor site, the estimated medians of the annual volume growth rates were 13.6% (IQR:0.8 -30.4) for HNP, -6.06% (IQR: -1.79;47.32) for thoracic PGLs, and 10.5% (IQR: -2.2;44.6) for abdominal PGLs. The volume doubling time was 5.44 years (2.61; 87.0) for HNP, 11.8 years (1.79;+∞) for thoracic PGLs, and 6.94 years (1,88;+∞) for abdominal PGLs. There was no significant difference in the volume growth rate according to tumor location or initial size (P>.7 and P = .07, respectively) or gene mutation type (SDHB vs. SDHD, P>.8). CONCLUSION: PGLs related to SDHx mutations are slowly growing tumors. There were no correlations between tumor location, growth rate or initial size over a 23-month follow-up period. ABBREVIATIONS: CT = computed tomography HNP = head and neck paraganglioma IQR = interquartile range PGL = paraganglioma PPGL = pheochromocytoma and paraganglioma SDH = succinate dehydrogenase.
Assuntos
Mutação em Linhagem Germinativa , Paraganglioma/genética , Paraganglioma/patologia , Succinato Desidrogenase/genética , Neoplasias das Glândulas Suprarrenais/genética , Adulto , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paraganglioma/diagnóstico por imagem , Feocromocitoma/genética , Tomografia Computadorizada por Raios X , Adulto JovemRESUMO
BACKGROUND: Measurements of plasma concentrations of free normetanephrine (NMN), metanephrine (MN) and methoxytyramine (MTY) constitute the most diagnostically accurate screening test for pheochromocytomas and paragangliomas. The aim of this article is to present the results from a validation of an analytical method utilizing high performance liquid chromatography with coulometric detection (HPLC-CD) for quantifying plasma free NMN, MN and MTY. Additionally, peak integration by height and area and the use of one calibration curve for all batches or individual calibration curve for each batch of samples was explored as to determine the optimal approach with regard to accuracy and precision. METHODS: The method was validated using charcoal stripped plasma spiked with solutions of NMN, MN, MTY and internal standard (4-hydroxy-3-methoxybenzylamine) with the exception of selectivity which was evaluated by analysis of real plasma samples. Calibration curve performance, accuracy, precision and recovery were determined following both peak-area and peak-height measurements and the obtained results were compared. The most accurate and precise method of calibration was evaluated by analyzing quality control samples at three concentration levels in 30 analytical runs. RESULTS: The detector response was linear over the entire tested concentration range from 10 to 2000pg/mL with R(2)≥0.9988. The LLOQ was 10pg/mL for each analyte of interest. To improve accuracy for measurements at low concentrations, a weighted (1/amount) linear regression model was employed, which resulted in inaccuracies of -2.48 to 9.78% and 0.22 to 7.81% following peak-area and peak-height integration, respectively. The imprecisions ranged from 1.07 to 15.45% and from 0.70 to 11.65% for peak-area and peak-height measurements, respectively. The optimal approach to calibration was the one utilizing an individual calibration curve for each batch of samples and peak-height measurements. It was characterized by inaccuracies ranging from -3.39 to +3.27% and imprecisions from 2.17 to 13.57%. CONCLUSIONS: The established HPLC-CD method enables accurate and precise measurements of plasma free NMN, MN and MTY with reasonable selectivity. Preparing calibration curve based on peak-height measurements for each batch of samples yields optimal accuracy and precision.