Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Blood Purif ; 47 Suppl 2: 74-80, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30943473

RESUMO

Background/ Aims: Owing to practical and technical developments, continuous renal replacement therapy (CRRT) has been administered even in critically ill neonates. In this study, the complications in CRRT for neonates were examined to establish a safe CRRT. METHODS: This retrospective study reviewed the clinical records of neonates who underwent CRRT at our neonatal intensive care unit between 2009 and 2017. RESULTS: Eight neonates with a body weight of 1,462-3,288 g were treated by 70 CRRT sessions with blood priming. Intradialytic hypotension (IDH) was observed in 39 sessions (55.7%), most of which occurred soon after the start of the CRRT. Body temperature decreased in 48 sessions (70.5%), and thrombocytopenia during CRRT occurred 30 times (42.9%). CONCLUSION: Complications during CRRT in neonates comprised IDH at the start of the CRRT, body temperature decline, and thrombocytopenia. These complications need to be analyzed for a safe neonatal CRRT.


Assuntos
Hipotensão/etiologia , Hipotermia/etiologia , Terapia de Substituição Renal/efeitos adversos , Trombocitopenia/etiologia , Estado Terminal , Feminino , Humanos , Recém-Nascido , Unidades de Terapia Intensiva , Masculino , Terapia de Substituição Renal/métodos , Estudos Retrospectivos
2.
Pediatr Int ; 61(7): 706-711, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30779413

RESUMO

BACKGROUND: Overnight catheter drainage (OCD) is introduced to avoid overdistention of the bladder at night-time when clean intermittent catheterization proves ineffective for daytime management of neurogenic bladder. We adopted OCD using disposable silicone no-balloon (DSnB) catheters, with the distal end outside the body opening into diapers. OCD using DSnB catheter, however, had risks of retrograde bacterial contamination. Therefore, in this study, the validity of equipping DSnB catheters with check valves to prevent retrograde bacterial contamination was examined. METHODS: For the in vitro study, excised saline-filled swine bladders were drained using DSnB catheters with or without check valves, and the time required for intravesical pressure to reach 5 cmH2 O was measured. For the in vivo study, in cross-over experiments comparing DSnB catheters with and without check valves, OCD using DSnB catheters for 10 h was performed in rabbits under analgesia. Bacterial growth from urine samples before and after OCD and residual urine volume were examined. RESULTS: For the in vitro experiment, the median drainage time was 368.2 s (range, 88-1,085 s) and 344.7 s (range, 28-840 s) with and without check valves, respectively (n = 6), which was not significantly different. For the in vivo experiment, in cross-over experiments (n = 8) new bacterial growth rates after OCD did not differ, and median residual urine volume was 17.1 mL (range, 0-75 mL) and 1.2 mL (range, 0-5 mL) with and without check valves, respectively (P = 0.055). CONCLUSIONS: Installing a check valve in the DSnB catheter did not decrease new bacterial growth, while tending to increase residual urine volume. DSnB catheters without check valves appear to be better for continuous drainage of urine from bladder.


Assuntos
Equipamentos Descartáveis , Drenagem/instrumentação , Bexiga Urinaria Neurogênica/terapia , Cateterismo Urinário/instrumentação , Cateteres Urinários , Animais , Estudos Cross-Over , Equipamentos Descartáveis/microbiologia , Drenagem/efeitos adversos , Drenagem/métodos , Técnicas In Vitro , Masculino , Coelhos , Distribuição Aleatória , Suínos , Cateterismo Urinário/efeitos adversos , Cateterismo Urinário/métodos , Cateteres Urinários/efeitos adversos , Cateteres Urinários/microbiologia , Infecções Urinárias/etiologia , Infecções Urinárias/prevenção & controle
3.
Pediatr Nephrol ; 31(3): 493-500, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26493070

RESUMO

BACKGROUND: We automated our manual, syringe-driven extracorporeal renal replacement therapy (eRRT) system with an ultra-small volume circuit (3.2 ml) that is suitable for neonates without blood priming. Our objective was to determine the solute clearance and water balance of the automated and manual systems in vitro. METHODS: Stored whole blood samples containing exogenous urea, creatinine (Cr), potassium (K), and ammonia (NH3) to imitate acute kidney injury (AKI) and hyperammonemia were dialyzed for 3 h (blood flow, 4.0 ml/min; dialysate flow, 600 ml/h) with a continuous infusion of heparin. Solute clearance and sample weight were then compared with values before dialysis. RESULTS: The median clearance of blood urea nitrogen, Cr, K, and NH3 ranged from 1.7 to 2.3 and from 2.4 to 2.6 ml/min, and the median weight of the samples was decreased by 3.8 g and increased by 8.3 g after 3 h of dialysis using the manual and automated systems, respectively. CONCLUSIONS: The automated system effectively cleared solutes, but safety concerns were associated with platelet consumption and fluid balance. Additional studies are needed to establish the safety and accuracy of this novel system for clinical use in neonates and preterm infants.


Assuntos
Injúria Renal Aguda/terapia , Soluções para Diálise/administração & dosagem , Circulação Extracorpórea/instrumentação , Hiperamonemia/terapia , Diálise Renal/instrumentação , Injúria Renal Aguda/sangue , Amônia/sangue , Automação , Biomarcadores/sangue , Nitrogênio da Ureia Sanguínea , Creatinina/sangue , Soluções para Diálise/efeitos adversos , Desenho de Equipamento , Circulação Extracorpórea/efeitos adversos , Circulação Extracorpórea/métodos , Humanos , Hiperamonemia/sangue , Recém-Nascido , Recém-Nascido Prematuro , Miniaturização , Potássio/sangue , Diálise Renal/efeitos adversos , Diálise Renal/métodos , Fatores de Risco , Fatores de Tempo , Equilíbrio Hidroeletrolítico
4.
CEN Case Rep ; 2024 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-39367958

RESUMO

Chronic kidney disease associated with low birth weight and/or premature birth (L/P-CKD) in infants may result from a decreased number of nephrons at birth. These infants may develop acute kidney injury due to exposure to nephrotoxic substances or other events during nephrogenesis in early infancy. Nonetheless, L/P-CKD progression remains unclear. We present three cases of L/P-CKD diagnosed after neonatal intensive care unit (NICU) discharge. Three patients were born extremely prematurely (gestational age, 24-26 weeks) with extremely low birth weight (606-906 g). They were admitted to the NICU (117-311 days) anad received several nephrotoxic medications during the early postnatal period. They showed elevated serum creatinine levels at 4 weeks after birth, which decreased to normal levels at NICU discharge. Proteinuria was first detected during adolescence (10-15 years) on annual school urine screening, with a remarkable increase in their height (18 - 50.8 cm), without known episodes of urinary tract infection, dehydration, lifestyle-related issues, such as excessive salt/protein intake, and extreme lack of exercise that might have caused kidney damage. Their kidneys were smaller than normal on renal ultrasonography. Open renal biopsy findings indicated glomerulomegaly and perihilar glomerulosclerosis in two of the three patients, suggesting glomerular hypertension. The remarkable differences between the body height before CKD and the timing of diagnosis of CKD could contribute to the progress of CKD. Long-term follow-up of low birth weight and extremely premature infants, from NICU discharge until adulthood, should be established.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA