Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Surg Endosc ; 38(5): 2734-2745, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38561583

RESUMO

BACKGROUND: Intraoperative cholangiography (IOC) is a contrast-enhanced X-ray acquired during laparoscopic cholecystectomy. IOC images the biliary tree whereby filling defects, anatomical anomalies and duct injuries can be identified. In Australia, IOC are performed in over 81% of cholecystectomies compared with 20 to 30% internationally (Welfare AIoHa in Australian Atlas of Healthcare Variation, 2017). In this study, we aim to train artificial intelligence (AI) algorithms to interpret anatomy and recognise abnormalities in IOC images. This has potential utility in (a) intraoperative safety mechanisms to limit the risk of missed ductal injury or stone, (b) surgical training and coaching, and (c) auditing of cholangiogram quality. METHODOLOGY: Semantic segmentation masks were applied to a dataset of 1000 cholangiograms with 10 classes. Classes corresponded to anatomy, filling defects and the cholangiogram catheter instrument. Segmentation masks were applied by a surgical trainee and reviewed by a radiologist. Two convolutional neural networks (CNNs), DeeplabV3+ and U-Net, were trained and validated using 900 (90%) labelled frames. Testing was conducted on 100 (10%) hold-out frames. CNN generated segmentation class masks were compared with ground truth segmentation masks to evaluate performance according to a pixel-wise comparison. RESULTS: The trained CNNs recognised all classes.. U-Net and DeeplabV3+ achieved a mean F1 of 0.64 and 0.70 respectively in class segmentation, excluding the background class. The presence of individual classes was correctly recognised in over 80% of cases. Given the limited local dataset, these results provide proof of concept in the development of an accurate and clinically useful tool to aid in the interpretation and quality control of intraoperative cholangiograms. CONCLUSION: Our results demonstrate that a CNN can be trained to identify anatomical structures in IOC images. Future performance can be improved with the use of larger, more diverse training datasets. Implementation of this technology may provide cholangiogram quality control and improve intraoperative detection of ductal injuries or ductal injuries.


Assuntos
Colangiografia , Colecistectomia Laparoscópica , Redes Neurais de Computação , Humanos , Colangiografia/métodos , Cuidados Intraoperatórios/métodos , Ductos Biliares/diagnóstico por imagem , Ductos Biliares/lesões , Algoritmos
2.
J Virol ; 93(21)2019 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-31413132

RESUMO

Vaccines aimed at inducing T cell responses to protect against human immunodeficiency virus (HIV) infection have been under development for more than 15 years. Replication-defective adenovirus (rAd) vaccine vectors are at the forefront of this work and have been tested extensively in the simian immunodeficiency virus (SIV) challenge macaque model. Vaccination with rAd vectors coding for SIV Gag or other nonenvelope proteins induces T cell responses that control virus load but disappointingly is unsuccessful so far in preventing infection, and attention has turned to inducing antibodies to the envelope. However, here we report that Mauritian cynomolgus macaques (MCM), Macaca fascicularis, vaccinated with unmodified SIV gag alone in a DNA prime followed by an rAd boost exhibit increased protection from infection by repeated intrarectal challenge with low-dose SIVmac251. There was no evidence of infection followed by eradication. A significant correlation was observed between cytokine expression by CD4 T cells and delayed infection. Vaccination with gag fused to the ubiquitin gene or fragmented, designed to increase CD8 magnitude and breadth, did not confer resistance to challenge or enhance immunity. On infection, a significant reduction in peak virus load was observed in all vaccinated animals, including those vaccinated with modified gag These findings suggest that a nonpersistent viral vector vaccine coding for internal virus proteins may be able to protect against HIV type 1 (HIV-1) infection. The mechanisms are probably distinct from those of antibody-mediated virus neutralization or cytotoxic CD8 cell killing of virus-infected cells and may be mediated in part by CD4 T cells.IMPORTANCE The simian immunodeficiency virus (SIV) macaque model represents the best animal model for testing new human immunodeficiency virus type 1 (HIV-1) vaccines. Previous studies employing replication-defective adenovirus (rAd) vectors that transiently express SIV internal proteins induced T cell responses that controlled virus load but did not protect against virus challenge. However, we show for the first time that SIV gag delivered in a DNA prime followed by a boost with an rAd vector confers resistance to SIV intrarectal challenge. Other partially successful SIV/HIV-1 protective vaccines induce antibody to the envelope and neutralize the virus or mediate antibody-dependent cytotoxicity. Induction of CD8 T cells which do not prevent initial infection but eradicate infected cells before infection becomes established has also shown some success. In contrast, the vaccine described here mediates resistance by a different mechanism from that described above, which may reflect CD4 T cell activity. This could indicate an alternative approach for HIV-1 vaccine development.


Assuntos
Produtos do Gene gag/imunologia , Vacinas contra a SAIDS/imunologia , Síndrome de Imunodeficiência Adquirida dos Símios/prevenção & controle , Vírus da Imunodeficiência Símia/imunologia , Adenoviridae/genética , Adenoviridae/imunologia , Animais , Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD8-Positivos/imunologia , Vírus Defeituosos/genética , Vírus Defeituosos/imunologia , Produtos do Gene gag/genética , Vetores Genéticos/genética , Vetores Genéticos/imunologia , Macaca fascicularis , Masculino , Vacinas contra a SAIDS/administração & dosagem , Vacinas contra a SAIDS/genética , Síndrome de Imunodeficiência Adquirida dos Símios/imunologia , Síndrome de Imunodeficiência Adquirida dos Símios/virologia , Vírus da Imunodeficiência Símia/genética , Vacinação , Vacinas de DNA/administração & dosagem , Vacinas de DNA/genética , Vacinas de DNA/imunologia , Carga Viral
3.
Nonlinear Dynamics Psychol Life Sci ; 24(1): 127-141, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31855554

RESUMO

This year's cover artists are members of a newly formed team of designers and scientists known as the Science and Design Laboratory, along with flooring manufacturing experts from the Mohawk Group. This unique collab-oration creates patterns for installation on the floors of versatile commercial, public and private spaces including airports, hospitals, offices and homes. Their goal is to create human-centered designs based on psychology experiments that investigate the positive impacts of viewing fractal patterns. These include reduced physiological stress levels, enhanced cognitive skills, and heightened concentration. Here, the fractal construction process and the resulting fractal characteristics of these designs are explained.

4.
Emerg Infect Dis ; 25(2): 205-211, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30666925

RESUMO

Recent years have seen unprecedented investment in research and development for countermeasures for high-threat pathogens, including specific and ambitious objectives for development of diagnostics, therapeutics, and vaccines. The inadequate availability of biological reference materials for these pathogens poses a genuine obstacle in pursuit of these objectives, and the lack of a comprehensive and equitable framework for developing reference materials is a weakness. We outline the need for internationally standardized biological materials for high-threat pathogens as a core element of global health security. We also outline the key components of a framework for addressing this deficiency.


Assuntos
Bancos de Espécimes Biológicos/normas , Doenças Transmissíveis/epidemiologia , Animais , Controle de Doenças Transmissíveis , Doenças Transmissíveis/diagnóstico , Doenças Transmissíveis/etiologia , Doenças Transmissíveis/terapia , Epidemias , Saúde Global , Humanos , Consentimento Livre e Esclarecido , Pesquisa , Vacinas , Organização Mundial da Saúde
6.
PLoS Pathog ; 12(12): e1006083, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28002473

RESUMO

In order to evaluate the role of persisting virus replication during occult phase immunisation in the live attenuated SIV vaccine model, a novel SIVmac239Δnef variant (SIVrtTA) genetically engineered to replicate in the presence of doxycycline was evaluated for its ability to protect against wild-type SIVmac239. Indian rhesus macaques were vaccinated either with SIVrtTA or with SIVmac239Δnef. Doxycycline was withdrawn from 4 of 8 SIVrtTA vaccinates before challenge with wild-type virus. Unvaccinated challenge controls exhibited ~107 peak plasma viral RNA copies/ml persisting beyond the acute phase. Six vaccinates, four SIVmac239Δnef and two SIVrtTA vaccinates exhibited complete protection, defined by lack of wild-type viraemia post-challenge and virus-specific PCR analysis of tissues recovered post-mortem, whereas six SIVrtTA vaccinates were protected from high levels of viraemia. Critically, the complete protection in two SIVrtTA vaccinates was associated with enhanced SIVrtTA replication in the immediate post-acute vaccination period but was independent of doxycycline status at the time of challenge. Mutations were identified in the LTR promoter region and rtTA gene that do not affect doxycycline-control but were associated with enhanced post-acute phase replication in protected vaccinates. High frequencies of total circulating CD8+T effector memory cells and a higher total frequency of SIV-specific CD8+ mono and polyfunctional T cells on the day of wild-type challenge were associated with complete protection but these parameters were not predictive of outcome when assessed 130 days after challenge. Moreover, challenge virus-specific Nef CD8+ polyfunctional T cell responses and antigen were detected in tissues post mortem in completely-protected macaques indicating post-challenge control of infection. Within the parameters of the study design, on-going occult-phase replication may not be absolutely required for protective immunity.


Assuntos
Vacinas contra a SAIDS/imunologia , Síndrome de Imunodeficiência Adquirida dos Símios/imunologia , Vírus da Imunodeficiência Símia/imunologia , Replicação Viral/imunologia , Animais , Imuno-Histoquímica , Imunofenotipagem , Macaca mulatta , Reação em Cadeia da Polimerase , Vacinas Atenuadas
7.
Proc Natl Acad Sci U S A ; 112(48): 14978-83, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26627249

RESUMO

Photosynthetic microorganisms typically have multiple isoforms of the electron transfer protein ferredoxin, although we know little about their exact functions. Surprisingly, a Chlamydomonas reinhardtii mutant null for the ferredoxin-5 gene (FDX5) completely ceased growth in the dark, with both photosynthetic and respiratory functions severely compromised; growth in the light was unaffected. Thylakoid membranes in dark-maintained fdx5 mutant cells became severely disorganized concomitant with a marked decrease in the ratio of monogalactosyldiacylglycerol to digalactosyldiacylglycerol, major lipids in photosynthetic membranes, and the accumulation of triacylglycerol. Furthermore, FDX5 was shown to physically interact with the fatty acid desaturases CrΔ4FAD and CrFAD6, likely donating electrons for the desaturation of fatty acids that stabilize monogalactosyldiacylglycerol. Our results suggest that in photosynthetic organisms, specific redox reactions sustain dark metabolism, with little impact on daytime growth, likely reflecting the tailoring of electron carriers to unique intracellular metabolic circuits under these two very distinct redox conditions.


Assuntos
Chlamydomonas reinhardtii/enzimologia , Ácidos Graxos Dessaturases/metabolismo , Ferredoxinas/metabolismo , Galactolipídeos/metabolismo , Proteínas de Plantas/metabolismo , Tilacoides/metabolismo , Chlamydomonas reinhardtii/genética , Ácidos Graxos Dessaturases/genética , Ferredoxinas/genética , Galactolipídeos/genética , Oxirredução , Proteínas de Plantas/genética , Tilacoides/genética
8.
Sci Justice ; 58(3): 185-190, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29685300

RESUMO

As part of a series of studies aimed at validating techniques in forensic odontology, this study aimed to validate the accuracy of ante-mortem (AM)/postmortem (PM) radiographic matching by dentists and forensic odontologists. This study used a web-based interface with 50 pairs of AM and PM radiographs from real casework, at varying degrees of difficulty. Participants were shown both radiographs as a pair and initially asked to decide if they represented the same individual using a yes/no binary choice forced-decision. Participants were asked to assess their level of confidence in their decision, and to make a conclusion using one of the ABFO (American Board of Forensic Odontology), INTERPOL (International Criminal Police Organisation) and DVISys™ (DVI System International, Plass Data Software) identification scale degrees. The mean false-positive rate using the binary choice scale was 12%. Overall accuracy was 89% using this model, however, 13% of participants scored below 80%. Only 25% of participants accurately answered yes or no >90% of the time, with no individual making the correct yes/no decision for all 50 pairs of radiographs. Non-odontologists (lay participants) scored poorly, with a mean accuracy of only 60%. Use of the graded ABFO, DVISYS and INTERPOL scales resulted in general improvements in performance, with the false-positive and false-negative rates falling to approximately 2% overall. Inter-examiner agreement in assigning scale degrees was good (ICC=0.64), however there was little correlation between confidence and both accuracy or agreement among practitioners. These results suggest that use of a non-binary scale is supported over a match/non-match call as it reduces the frequency of false positives and negatives. The use of the terms "possible" and "insufficient information" in the same scale appears to create confusion, reducing inter-examiner agreement. The lack of agreement between higher-performing and lower-performing groups suggests that there is an inconsistency in the cognitive processes used to determine similarity between radiographs.


Assuntos
Odontologia Legal , Variações Dependentes do Observador , Radiografia Dentária , Estudos de Casos e Controles , Humanos , Inquéritos e Questionários
13.
Lancet Microbe ; 5(3): e301-e305, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38224703

RESUMO

The COVID-19 pandemic led to the rapid development of tests to diagnose SARS-CoV-2 infection and ascertain the prevalence of infection, along with the formulation of various treatments and vaccines. Globally, over 220 anti-SARS-CoV-2 serological assays have been developed for laboratory use, and many of these assays are currently used to assess immune responses against SARS-CoV-2. However, because these assays were independently developed by different manufacturers with different target antigens, immunoglobulin detection, technologies, and data reporting approaches, the results are not directly comparable, making it challenging to draw conclusions regarding immune responses at the population level. With deficiencies in assay validation, standardisation, and harmonisation, the inability to use and compare large datasets is becoming a major issue as serological data continue to increase. To help in addressing this issue, WHO established the first International Standard for the anti-SARS-CoV-2 immunoglobulin in late 2020. In this Personal View, we define the WHO International Standard for the anti-SARS-CoV-2 immunoglobulin, summarise the uses of primary versus secondary serology standards, recommend the use of such standards for data harmonisation, and list guidance and resources for using serology standards to improve data comparability.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Teste para COVID-19 , Pandemias , Técnicas de Laboratório Clínico/métodos , Testes Sorológicos/métodos , Anticorpos Antivirais , Sensibilidade e Especificidade , Organização Mundial da Saúde
14.
Lancet Microbe ; 5(3): e216-e225, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38278167

RESUMO

BACKGROUND: Accurate quantitation of immune markers is crucial for ensuring reliable assessment of vaccine efficacy against infectious diseases. This study was designed to confirm standardised performance of SARS-CoV-2 assays used to evaluate COVID-19 vaccine candidates at the initial seven laboratories (in North America, Europe, and Asia) of the Coalition for Epidemic Preparedness Innovations (CEPI) Centralized Laboratory Network (CLN). METHODS: Three ELISAs (pre-spike protein, receptor binding domain, and nucleocapsid), a microneutralisation assay (MNA), a pseudotyped virus-based neutralisation assay (PNA), and an IFN-γ T-cell ELISpot assay were developed, validated or qualified, and transferred to participating laboratories. Immune responses were measured in ELISA laboratory units (ELU) for ELISA, 50% neuralisation dilution (ND50) for MNA, 50% neutralisation titre (NT50) for PNA, and spot-forming units for the ELISpot assay. Replicate assay results of well characterised panels and controls of blood samples from individuals with or without SARS-CoV-2 infection were evaluated by geometric mean ratios, standard deviation, linear regression, and Spearman correlation analysis for consistency, accuracy, and linearity of quantitative measurements across all laboratories. FINDINGS: High reproducibility of results across all laboratories was demonstrated, with interlaboratory precision of 4·1-7·7% coefficient of variation for all three ELISAs, 3·8-19·5% for PNA, and 17·1-24·1% for MNA, over a linear range of 11-30 760 ELU per mL for the three ELISAs, 14-7876 NT50 per mL for PNA, and 21-25 587 ND50 per mL for MNA. The MNA was also adapted for detection of neutralising antibodies against the major SARS-CoV-2 variants of concern. The results of PNA and MNA (r=0·864) and of ELISA and PNA (r=0·928) were highly correlated. The IFN-γ ELISpot interlaboratory variability was 15·9-49·9% coefficient of variation. Sensitivity and specificity were close to 100% for all assays. INTERPRETATION: The CEPI CLN provides accurate quantitation of anti-SARS-CoV-2 immune response across laboratories to allow direct comparisons of different vaccine formulations in different geographical areas. Lessons learned from this programme will serve as a model for faster responses to future pandemic threats and roll-out of effective vaccines. FUNDING: CEPI.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Laboratórios , Reprodutibilidade dos Testes , Anticorpos Antivirais , Imunidade
15.
J Biol Chem ; 287(19): 15811-25, 2012 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-22403401

RESUMO

Algae have recently gained attention as a potential source for biodiesel; however, much is still unknown about the biological triggers that cause the production of triacylglycerols. We used RNA-Seq as a tool for discovering genes responsible for triacylglycerol (TAG) production in Chlamydomonas and for the regulatory components that activate the pathway. Three genes encoding acyltransferases, DGAT1, DGTT1, and PDAT1, are induced by nitrogen starvation and are likely to have a role in TAG accumulation based on their patterns of expression. DGAT1 and DGTT1 also show increased mRNA abundance in other TAG-accumulating conditions (minus sulfur, minus phosphorus, minus zinc, and minus iron). Insertional mutants, pdat1-1 and pdat1-2, accumulate 25% less TAG compared with the parent strain, CC-4425, which demonstrates the relevance of the trans-acylation pathway in Chlamydomonas. The biochemical functions of DGTT1 and PDAT1 were validated by rescue of oleic acid sensitivity and restoration of TAG accumulation in a yeast strain lacking all acyltransferase activity. Time course analyses suggest than a SQUAMOSA promoter-binding protein domain transcription factor, whose mRNA increases precede that of lipid biosynthesis genes like DGAT1, is a candidate regulator of the nitrogen deficiency responses. An insertional mutant, nrr1-1, accumulates only 50% of the TAG compared with the parental strain in nitrogen-starvation conditions and is unaffected by other nutrient stresses, suggesting the specificity of this regulator for nitrogen-deprivation conditions.


Assuntos
Aciltransferases/genética , Chlamydomonas reinhardtii/genética , Nitrogênio/metabolismo , Proteínas de Plantas/genética , Triglicerídeos/metabolismo , Aciltransferases/metabolismo , Chlamydomonas reinhardtii/enzimologia , Chlamydomonas reinhardtii/metabolismo , Perfilação da Expressão Gênica , Regulação Enzimológica da Expressão Gênica , Teste de Complementação Genética , Isoenzimas/genética , Isoenzimas/metabolismo , Dados de Sequência Molecular , Mutação , Proteínas de Plantas/metabolismo , Reprodutibilidade dos Testes , Genética Reversa/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Saccharomyces cerevisiae/enzimologia , Saccharomyces cerevisiae/genética , Saccharomyces cerevisiae/metabolismo , Análise de Sequência de DNA , Fatores de Tempo
16.
Retrovirology ; 10: 59, 2013 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-23738926

RESUMO

BACKGROUND: Live attenuated SIV induces potent protection against superinfection with virulent virus; however the mechanism of this vaccine effect is poorly understood. Such knowledge is important for the development of clinically acceptable vaccine modalities against HIV. RESULTS: Using a novel, doxycycline dependent, replication-competent live-attenuated SIVmac239Δnef (SIV-rtTAΔnef), we show that under replication-permissive conditions SIV-rtTAΔnef is fully viable. Twelve rhesus macaques were infected with a peak plasma vRNA on average two log10 lower than in 6 macaques infected with unconditionally replication-competent SIVΔnef. Consistent with the attenuated phenotype of the viruses the majority of animals displayed low or undetectable levels of viraemia by 42-84 days after infection. Next, comparison of circulating T cells before and after chronic infection with parental SIVΔnef revealed a profound global polarisation toward CD28-CCR7- T-effector memory 2 (TEM2) cells within CD95+CD4+ and CD95+CD8+ populations. Critically, a similar effect was seen in the CD95+ CD4+ population and to somewhat lesser extent in the CD95+ CD8+ population of SIV-rtTAΔnef chronically infected macaques that were maintained on doxycycline, but was not seen in animals from which doxycycline had been withdrawn. The proportions of gut-homing T-central memory (TCM) and TEM defined by the expression of α4ß7 and CD95 and differential expression of CD28 were increased in CD4 and CD8 cells under replication competent conditions and gut-homing CD4 TCM were also significantly increased under non-permissive conditions. TEM2 polarisation was seen in the small intestines of animals under replication permissive conditions but the effect was less pronounced than in the circulation. Intracellular cytokine staining of circulating SIV-specific T cells for IL-2, IFN-γ, TNF-α and IL-17 showed that the extent of polyfunctionality in CD4 and CD8 T cells was associated with replication permissivity; however, signature patterns of cytokine combinations were not distinguishable between groups of macaques. CONCLUSION: Taken together our results show that the global T memory cell compartment is profoundly skewed towards a mature effector phenotype by attenuated SIV. Results with the replication-conditional mutant suggest that maintenance of this effect, that may be important in vaccine design, might require persistence of replicating virus.


Assuntos
Anticorpos Antivirais/imunologia , Vacinas contra a SAIDS/imunologia , Síndrome de Imunodeficiência Adquirida dos Símios/imunologia , Vírus da Imunodeficiência Símia/imunologia , Linfócitos T/imunologia , Animais , Anti-Infecciosos/farmacologia , Doxiciclina/farmacologia , Memória Imunológica/fisiologia , Intestino Delgado/virologia , Macaca mulatta , Fenótipo , RNA Viral/genética , Síndrome de Imunodeficiência Adquirida dos Símios/prevenção & controle , Síndrome de Imunodeficiência Adquirida dos Símios/virologia , Vírus da Imunodeficiência Símia/efeitos dos fármacos , Vírus da Imunodeficiência Símia/fisiologia , Superinfecção/prevenção & controle , Regulação para Cima , Vacinas Atenuadas/imunologia , Viremia , Replicação Viral
17.
Pediatr Radiol ; 43(7): 846-50, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23381302

RESUMO

BACKGROUND: Urological investigation in children frequently involves high radiation doses; however, the issue of radiation for these investigations receives little attention compared with CT. OBJECTIVE: To compare the radiation dose from paediatric urological investigations with CT, which is commonly regarded as the more major source of radiation exposure. MATERIALS AND METHODS: We conducted a retrospective audit in a tertiary paediatric centre of the number and radiation dose of CT scans, micturating cystourethrography exams and urological nuclear medicine scans from 2006 to 2011. This was compared with radiation doses in the literature and an audit of the frequency of these studies in Australia. RESULTS: The tertiary centre audit demonstrated that the ratio of the frequency of urological to CT examinations was 0.8:1 in children younger than 17 years. The ratio of the radiation dose of urological to CT examinations was 0.7:1. The ratio in children younger than 5 years was 1.9:1. In Australia the frequency of urological procedures compared with CT was 0.4:1 in children younger than 17 years and 3.1:1 in those younger than 5 years. The ratio of radiation-related publications was 1:9 favouring CT. CONCLUSION: The incidence and radiation dose of paediatric urological studies is comparable to those of CT. Nevertheless the radiation dose of urological procedures receives considerably less attention in the literature.


Assuntos
Doses de Radiação , Radiometria/estatística & dados numéricos , Tomografia Computadorizada de Emissão/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Urografia/estatística & dados numéricos , Doenças Urológicas/diagnóstico por imagem , Doenças Urológicas/epidemiologia , Adolescente , Austrália/epidemiologia , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Auditoria Médica , Prevalência , Fatores de Risco
18.
Eur Urol Open Sci ; 50: 91-105, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37101769

RESUMO

Context: Prostate cancer (PCa) remains one of the leading causes of cancer-related deaths in men worldwide. Men at risk are typically offered multiparametric magnetic resonance imaging and, if suspicious, a targeted biopsy. However, false-negative rates of magnetic resonance imaging are consistently 18%; therefore, there is growing interest in improving the diagnostic performance of imaging through novel technologies. Prostate-specific membrane antigen (PSMA) positron emission tomography (PET) is being utilised for PCa staging and, more recently, for intraprostatic tumour localisation. However, significant variability has been observed in how PSMA PET is performed and reported. Objective: In this review, we aim to evaluate how pervasive this variability is in trials investigating the performance of PSMA PET in primary PCa workup. Evidence acquisition: Following the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines, we performed an optimal search in five different databases. After removing duplicates, 65 studies were included in our review. Evidence synthesis: Studies dated back as early as 2016, with numerous different source countries. There was variation in the reference standard for PSMA PET, with some using biopsy specimens or surgical specimens, and in some cases, a combination of the two. Similar inconsistencies were noted when studies selected histological definitions of clinically significant PCa, while some omitted their definition altogether. The most significant variations in performing PSMA PET were the radiotracer type, dose, acquisition time after injection, and the PET camera being utilised. Substantial variation in the reporting of PSMA PET was noted, with no consistency in defining what constitutes a positive intraprostatic lesion. Across 65 studies, four different definitions were used. Conclusions: This systematic review has highlighted considerable variation in obtaining and performing a PSMA PET study in the context of primary PCa diagnosis. Given the discrepancy in how PSMA PET was performed and reported, it questions the homogony of studies from centre to centre. Standardisation of PSMA PET is required for this to become a consistently useful and reproducible modality in the diagnosis of PCa. Patient summary: Prostate-specific membrane antigen (PSMA) positron emission tomography (PET) is being utilised for staging and localisation of prostate cancer (PCa); however, there is significant variability in performing and reporting PSMA PET. Standardisation of PSMA PET is required for results to be consistently useful and reproducible for the diagnosis of PCa.

19.
NPJ Vaccines ; 8(1): 95, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37391580

RESUMO

Reference materials are critical in assay development for calibrating and assessing their suitability. The devasting nature of the COVID-19 pandemic and subsequent proliferation of vaccine platforms and technologies has meant that there is even a greater need for standards for immunoassay development, which are critical to assess and compare vaccines' responses. Equally important are the standards needed to control the vaccine manufacturing processes. Standardized vaccine characterization assays throughout process development are essential for a successful Chemistry, Manufacturing and Controls (CMC) strategy. In this perspective paper, we advocate for reference material incorporation into assays and their calibration to International Standards from preclinical vaccine development through control testing and provide insight into why this is necessary. We also provide information on the availability of WHO international antibody standards for CEPI-priority pathogens.

20.
mSphere ; 8(1): e0056822, 2023 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-36719225

RESUMO

Having varied approaches to the design and manufacture of vaccines is critical in being able to respond to worldwide needs and newly emerging pathogens. Virus-like particles (VLPs) form the basis of two of the most successful licensed vaccines (against hepatitis B virus [HBV] and human papillomavirus). They are produced by recombinant expression of viral structural proteins, which assemble into immunogenic nanoparticles. VLPs can be modified to present unrelated antigens, and here we describe a universal "bolt-on" platform (termed VelcroVax) where the capturing VLP and the target antigen are produced separately. We utilize a modified HBV core (HBcAg) VLP with surface expression of a high-affinity binding sequence (Affimer) directed against a SUMO tag and use this to capture SUMO-tagged gp1 glycoprotein from the arenavirus Junín virus (JUNV). Using this model system, we have solved the first high-resolution structures of VelcroVax VLPs and shown that the VelcroVax-JUNV gp1 complex induces superior humoral immune responses compared to the noncomplexed viral protein. We propose that this system could be modified to present a range of antigens and therefore form the foundation of future rapid-response vaccination strategies. IMPORTANCE The hepatitis B core protein (HBc) forms noninfectious virus-like particles, which can be modified to present a capturing molecule, allowing suitably tagged antigens to be bound on their surface. This system can be adapted and provides the foundation for a universal "bolt-on" vaccine platform (termed VelcroVax) that can be easily and rapidly modified to generate nanoparticle vaccine candidates.


Assuntos
Vacinas , Humanos , Antígenos do Núcleo do Vírus da Hepatite B/genética , Vírus da Hepatite B , Glicoproteínas , Vacinação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA