Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 120(2): e2211416120, 2023 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-36595665

RESUMO

Soft systems that respond to external stimuli, such as heat, magnetic field, and light, find applications in a range of fields including soft robotics, energy harvesting, and biomedicine. However, most of the existing systems exhibit nondirectional, nastic movement as they can neither grow nor sense the direction of stimuli. In this regard, artificial systems are outperformed by organisms capable of directional growth in response to the sense of stimuli or tropic growth. Inspired by tropic growth schemes of plant cells and fungal hyphae, here we report an artificial multistimuli-responsive tropic tip-growing system based on nonsolvent-induced phase separation of polymer solution, where polymer precipitates as its solvent dissolves into surrounding nonsolvent. We provide a theoretical framework to predict the size and velocity of growing precipitates and demonstrate its capability of sensing the directions of gravity, mechanical contact, and light and adjusting its growing direction in response. Exploiting the embedded physical intelligence of sensing and responding to external stimuli, our soft material system achieves multiple tasks including printing 3D structures in a confined space, bypassing mechanical obstacles, and shielded transport of liquids within water.


Assuntos
Células Vegetais , Polímeros , Gravitação
2.
Biol Reprod ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38738783

RESUMO

Cryptorchidism, the failure of one or both testes to descend into the scrotum, and testicular cancer show a strong correlation in both dogs and humans. Yet, long-standing medical debates persist about whether the location of undescended testes directly causes testicular cancer in humans or if both conditions stem from a common origin. Although testicular cancer is a prevalent disease in dogs, even less is known about its cause and correlation with testicular descent in this species. This review investigates the relation between these two disorders in dogs, drawing insights from human studies, and examines key biomarkers identified thus far. In addition, it explores potential causal links, including the impact of temperature on maturing testicular cells and a potential shared genetic origin. Notably, this literature review reveals significant differences between men and dogs in reproductive development, histological and molecular features of testicular tumors, and the prevalence of specific tumor types, such as Sertoli cell tumors (SCTs) in cryptorchid dogs and germ cell tumors (GCTs) in humans. These disparities caution against using dogs as models for human testicular cancer research and underscore the limitations when drawing comparisons between species. The paper concludes by suggesting specific research initiatives to enhance our understanding of the complex interplay between cryptorchidism and testicular cancer in dogs.

3.
J Esthet Restor Dent ; 36(3): 445-452, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37671774

RESUMO

OBJECTIVE: This in vitro study aimed to evaluate the flexural strength (FS) and translucency parameter (TP) of resin nanoceramics (RNCs) with barium silicate for additive manufacturing. MATERIALS AND METHODS: An RNC slurry was prepared by mixing a barium silicate filler and resin monomer. For the FS tests, specimens with three filler contents (0, 50, and 63 wt%) were designed according to ISO6872 for dental ceramics and ISO10477 for dental polymers. These specimens were then formed into discs with thicknesses of 1 and 2 mm for TP measurement. RESULTS: In the specimens prepared according to ISO6872, the FS increased significantly depending on the filler content. However, in the case of ISO10477, there was no significant difference between the FSs of the specimens with 0 and 50 wt% filler contents. The increase in thickness affected translucency, and the lowest translucency was obtained at a filler content of 63 wt%. The filler distribution was dense in the specimen with 63 wt% filler and uniform but relatively sparse in the specimen with 50 wt% filler. More voids were observed in the specimen with 63 wt% filler. The thickness and filler content of the specimen affected its TP. The TP of the specimen with 63 wt% filler was similar to that of human enamel. CONCLUSION: The FS was significantly higher at a filler content of 63 wt%. The lowest translucency was obtained at a filler content of 63 wt% for all tested thicknesses. CLINICAL SIGNIFICANCE: Increasing the filler content was advantageous for the mechanical properties of the RNCs. A high filler content led to low translucency in the RNCs. Therefore, the esthetics of human teeth can be reproduced if layering according to the filler content is performed in areas where esthetic characteristics are required.


Assuntos
Porcelana Dentária , Resistência à Flexão , Humanos , Bário , Teste de Materiais , Silicatos , Propriedades de Superfície , Cerâmica
4.
J Prosthet Dent ; 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38443239

RESUMO

Mandibular condyle fracture malunion and tooth loss can cause functional and esthetic problems. A patient with restricted mouth opening associated with muscle atrophy required prosthetic rehabilitation. Since the remaining teeth had a poor prognosis and the patient had difficulty adapting to the interim denture, complete mouth rehabilitation with implants was chosen. The implants were placed by using nerve lateralization and an autogenous bone graft. Prosthetic rehabilitation combines digital diagnosis and conventional prosthetic restorations. The definitive prosthesis was fabricated to ensure adequate oral hygiene and functional adaptation of the orofacial structures. Treatment resulted in stable masticatory function, occlusion, and esthetics and restored the function of the atrophied lips and restricted mouth opening.

5.
J Prosthodont ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38822528

RESUMO

PURPOSE: Bilayered restorations have both the strength of the substructure material and the esthetics of the veneer material; however, they should have appropriate bonding between the two materials. This study aimed to evaluate the shear bond strength (SBS) according to the substructure material and veneering technique used in bilayered restorations. MATERIALS AND METHODS: The experimental group was divided into four groups (n = 15 per group) based on the substructure materials (cobalt-chromium [Co-Cr] alloy and 3 mol% yttrium-stabilized tetragonal zirconia polycrystal [3Y-TZP]) and veneering techniques (pressing and layering). Veneering was performed with disk shape (diameter: 5 mm, height: 2 mm) on a substructure using each veneering technique. Shear stress was applied to the interface of the substructure and the veneering ceramic using a universal testing machine. The shear bond strength, according to the substructure and veneering technique, was analyzed using a two-way analysis of variance with a post-hoc Tukey's honestly significant difference test. The failure mode was observed, and the surface was analyzed using a scanning electron microscope and energy-dispersive spectroscopy. RESULTS: The shSBS of the Co-Cr alloy and 3Y-TZP substructure was not different (p > 0.05); however, the pressing technique showed a higher SBS than the layering technique (p < 0.05). The SBS did not differ depending on the veneering technique in the Co-Cr alloys (p > 0.05), whereas the SBS in the pressing technique was higher than that in the layering technique for 3Y-TZP (p < 0.05). In the layering technique, the Co-Cr alloy showed a higher SBS than 3Y-TZP (p < 0.05). In the failure mode, mixed failure occurred most frequently in all groups. Extensive elemental interdiffusion was observed through the opaque layer in the Co-Cr alloy, regardless of the veneering technique. In 3Y-TZP, a wider range of elemental interdiffusion was observed in the pressing technique than in the layering technique. CONCLUSIONS: In bilayered restorations with a 3Y-TZP substructure, the pressing technique yielded higher bonding strength than layering. Using the layering technique, 3Y-TZP showed a lower SBS than the Co-Cr alloy. In bilayered restorations using 3Y-TZP as a substructure, the veneering technique and thermal compatibility of the materials must be considered.

6.
J Environ Manage ; 345: 118833, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37639910

RESUMO

In the present study, through the laboratory-to-field scale experiments and trials, we report the development and evaluation of an integrated oil-spill response system capable of oil collection, recovery (separation), and storage, for a timely and effective response to the initial stage of oil-spill accidents. With the laboratory-scale experiments, first, we evaluate that the water-surface waves tend to abate the oil recovery rate below 80% (it is above 95% for the optimized configuration without the waves), which is overcome by installing the hydrophilic (and oleophobic) porous structures at the inlet and/or near the water outlet of the separator. In the follow-up meso-scale towing tank tests with a scaled-up prototype, (i) we optimize the maneuverability of the assembled system depending on the speed and existence of waves, and (ii) evaluate the oil recovery performance (more than 80% recovery for the olive oil and Bunker A fuel oil). Although more thorough investigations and improvements are needed, a recovery rate of over 50% can be achieved for the newly enforced marine fuel oil (low sulfur fuel oil, LSFO) that was not targeted at the time of development. Finally, we perform a series of field tests with a full-scale system, to evaluate the rapid deployment and operational stability in the real marine environment. The overall floating balance and coordination of each functional part are sustained to be stable during the straight and rotary maneuvers up to the speed of 5 knots. Also, the collection of the floating debris (mimicking the spilled oil) is demonstrated in the field test. The present system is now being tested by the Korea Coast Guard and we believe that it will be very powerful to prevent the environmental damage due to the oil spills.


Assuntos
Óleos Combustíveis , Poluição por Petróleo , Baías , Laboratórios , Água
7.
J Prosthet Dent ; 130(4): 620-628, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34980473

RESUMO

STATEMENT OF PROBLEM: Lithium disilicate and 5 mol% yttria partially stabilized zirconia (5Y-PSZ) are commonly used for anterior restorations. However, studies comparing the durability of 5Y-PSZ and lithium disilicates are sparse. PURPOSE: The purpose of this in vitro study was to investigate the fracture load of anterior monolithic crowns made of 2 lithium disilicates and a 5Y-PSZ under dynamic loading. MATERIAL AND METHODS: Titanium abutments of the maxillary incisors were prepared (N=48, 8 for each group). Monolithic anterior crowns were made from the lithium disilicates (e.max CAD, Rosetta SM) and 5Y-PSZ (Katana UTML). After cementation, the specimens were stored in water for 24 hours and then thermocycled 10 000 times. Dynamic loading (70 N, 200 000 cycles, 1 Hz) was applied to half the specimens. The fracture load was measured by using a universal testing machine. The fracture patterns were analyzed and fractography applied. Two-way ANOVA and the Fisher exact test were used for statistical analysis (α=.05). RESULTS: The material and dynamic loading affected the fracture load of the anterior monolithic crowns (P<.05). However, there was no interaction between the material and the dynamic loading (P=.079). Both lithium disilicates had higher fracture loads than 5Y-PSZ (P<.05). The fracture load of each specimen was reduced after dynamic loading (P<.05). Lithium disilicate showed marginal and bulk fractures, and 5Y-PSZ presented catastrophic fractures (P<.001). CONCLUSIONS: 5Y-PSZ materials with large grains and low flexural strength may be less resistant to fractures under dynamic loading than lithium disilicates.

8.
J Prosthodont ; 32(9): 829-837, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36575827

RESUMO

PURPOSE: The mechanical and physical properties of implant screw access opening deteriorate if composite resin is not polymerized properly. Therefore, this study aimed to analyze the effect of using composite resin in implant access opening on the degree of conversion (DC). MATERIALS AND METHODS: Two prosthetic materials (Co-Cr and zirconia), two types of composite resin (low and high viscosity), two light-cured resin depths (2 and 3 mm), and two polymerization methods (max-mode 10 s and mid-mode 20 s: 16 and 22 J/cm2 , respectively) were considered (n = 192). The DC of the polymerized composite resin was measured through Fourier-transform infrared spectroscopy. The top and bottom surfaces of the polymerized composite resin body were observed through scanning electron microscopy. Multiple linear regression analysis and analysis of variance were used to identify significant differences in DC (α = 0.05). RESULTS: The DC was lower when the low-viscosity composite resin (ß = -0.431), light-polymerized resin depth of 2 mm (ß = -0.430), zirconia prosthesis (ß = -0.191), and mid-mode polymerization method (ß = -0.164) were used. The resin type, depth of resin to be light-cured, prosthesis material, and polymerization method had an effect on the DC. CONCLUSIONS: Low-viscosity composite resin should be polymerized at a low irradiance and long polymerization time (such that the light-cured resin depth does not exceed 2 mm) to ensure proper composite resin polymerization in implant screw access opening.


Assuntos
Resinas Compostas , Implantes Dentários , Resinas Compostas/química , Polimerização , Teste de Materiais , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície
9.
J Prosthodont ; 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38115183

RESUMO

PURPOSE: The purpose of this in vitro study was to compare the tensile bond strength (TBS) of resin nanoceramics (RNC), zirconia, and lithium disilicate (LS2) restorations cemented to titanium abutments before and after thermomechanical aging. MATERIALS AND METHODS: Twelve specimens per group were fabricated to determine the TBS between a titanium abutment and four types of crown materials (2 RNCs, LS2, and translucent zirconia crowns for the maxillary molar). After milling, the abutments and crowns were cemented with resin cement after air-particle abrasion. In addition, thermomechanical aging (200,000 cycles, 50 N, 2 Hz) was applied to half of the specimens by using a mastication simulator. TBS was measured by using a universal testing machine. The interface between the crown and the cement was observed by using scanning electron microscopy (SEM). Two-way ANOVA was performed to analyze the effects of crown materials and thermomechanical aging. Failure-mode and interface analyses were also conducted. RESULTS: After thermomechanical aging, the TBS decreased in the LS2 specimens and increased in RNCs (p < 0.001). The ratio of mixed failure and debonding with the hole-sealing resin increased in the RNC group. SEM images showed the reduced gap between the crown and the resin cement after thermomechanical aging in the RNC group. CONCLUSIONS: Differences in TBS were affected by the crown materials after thermomechanical aging. After thermomechanical aging, the RNC crowns showed increased TBS, whereas LS2 and zirconia crowns exhibited decreased or similar TBS.

10.
Reproduction ; 163(4): R71-R80, 2022 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-35167488

RESUMO

Ovulation is the fundamental biological process during which an oocyte is expelled from the ovary, and it is an essential step toward establishing a pregnancy. Understanding regulatory mechanisms governing the ovulation process is essential for diagnosing and treating causes of infertility, identifying contraceptive targets, and developing novel contraception methods. Endothelin-2 (EDN2) is a 21 amino acid-long peptide that is transiently synthesized by granulosa cells of the ovulatory follicle prior to ovulation and plays an essential role in ovulation via promoting contraction in the myofibroblast cells of the theca layer of the follicle. This review describes the organization of the endothelin system, summarizes recent findings on the expression and synthesis of the endothelin system in the ovary, illustrates the roles that EDN2 plays in regulating ovulation, and discusses EDN2 as a potential target of contraception.


Assuntos
Endotelina-2 , Ovulação , Endotelina-2/genética , Endotelina-2/metabolismo , Feminino , Fertilidade , Células da Granulosa/metabolismo , Humanos , Folículo Ovariano/metabolismo , Gravidez
11.
J Oral Rehabil ; 49(5): 522-528, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34888906

RESUMO

BACKGROUND: This study aimed to determine the correlation between occlusal contact area and masticatory performance using BiteEye® , a photo occlusal analysis device and the multiple sieve method. OBJECTIVES: To calculate the occlusal contact area at various levels of interocclusal thicknesses and to measure masticatory performance with peanuts as the test material. METHODS: Fifty-two adults (30 men and 22 women) were enrolled according to specific exclusion/inclusion criteria. The occlusal contact area was measured by obtaining the interocclusal record of the maximum intercuspal position (MIP) using silicone impression material. Occlusal contact area measurements were performed in the ranges of 0-149, 0-89, 0-59, 0-29 and 0-9 µm. Masticatory performance was measured by obtaining the median particle size (X 50 ) after converting the weight of comminuted peanuts into size using the multiple sieve method. Statistical analysis was performed at 95% significance level. RESULTS: Interocclusal thickness comparison revealed the highest correlation with X 50 in the 0-149 µm range. Stronger correlations between the occlusal contact area and X 50 were observed in cases of 20 strokes of mastication (r = -.451) than in cases of 10 strokes (r = -.383), in the posterior occlusal contact area (r = -.456) than in the full arch occlusal contact area (r = -.451) and the molar area (r = -.478) than in the premolar area (r = -.296). CONCLUSIONS: The larger the occlusal contact area, the higher the masticatory performance; this correlation was statistically significant. Regarding interocclusal thickness, the highest correlation between the occlusal contact area and masticatory performance was observed in the 0-149 µm range. CLINICAL TRIAL REGISTRATION NUMBER: GWNUDH IRB 2020-A001.


Assuntos
Força de Mordida , Acidente Vascular Cerebral , Adulto , Feminino , Humanos , Masculino , Mastigação
12.
J Prosthet Dent ; 127(3): 462-469, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33309295

RESUMO

STATEMENT OF PROBLEM: How axial displacement may be affected by the mechanical properties and internal discrepancy of a cement-retained implant-supported prosthesis is unclear. PURPOSE: The purpose of this in vitro study was to assess the difference in internal discrepancy and axial displacement according to the prosthesis material in cement-retained prostheses splinting nonparallel implants. MATERIAL AND METHODS: Computer-aided design and computer-aided manufacture (CAD-CAM) titanium abutments were fabricated for a vertically placed implant and a 15-degree tilted implant. Three types of prostheses, in zirconia, cobalt-chromium (Co-Cr) alloy, and polymethylmethacrylate resin (PMMA), were fabricated (n=10). The internal discrepancy between the CAD-CAM titanium abutment and the prosthesis was measured by using the replica technique. After luting with an interim cement, they were mounted in Type IV gypsum. The specimens were cyclic loaded, and axial displacement of the prosthesis was measured after 3, 10, 100, and 106 cycles. The internal discrepancy and cumulative axial displacement were assessed by using a 3-way analysis of variance and repeated measures analysis of variance (α=.05). RESULTS: The internal discrepancy of the prosthesis did not differ based on the prosthesis material (P=.869); however, it was significantly different based on the measurement location, with the occlusal discrepancy (224 ±29 µm) being greater than the axial discrepancy (21 ±10 µm) (P<.05). Implants with an angled placement exhibited less axial displacement than implants with vertical placement (P<.05). The PMMA prosthesis demonstrated significantly greater axial displacement than the zirconia or Co-Cr prostheses (P<.05), which were similar (P=.623). CONCLUSIONS: Prostheses made with high-elastic moduli materials exhibited less axial displacement than PMMA prostheses, even though the internal discrepancy was not different. Moreover, vertically placed implants presented a greater axial displacement of the prosthesis than implants with angled placement.


Assuntos
Implantes Dentários , Ligas de Cromo , Desenho Assistido por Computador , Dente Suporte , Cimentos Dentários/uso terapêutico , Materiais Dentários , Planejamento de Prótese Dentária/métodos , Prótese Dentária Fixada por Implante , Zircônio
13.
J Prosthet Dent ; 127(5): 785-792, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-33390272

RESUMO

STATEMENT OF PROBLEM: Materials have been developed to reduce the chipping of ceramic veneer and improve the esthetics of anterior ceramic veneered restorations. However, studies of the effects of material and substructure design on fracture resistance are sparse. PURPOSE: The purpose of this in vitro study was to investigate the fracture resistance of metal-ceramic (MC), zirconia-feldspathic porcelain (ZC), and zirconia-lithium disilicate (ZL) anterior restorations and evaluate the effect of material and substructure design. MATERIAL AND METHODS: After preparing and scanning artificial maxillary central incisor teeth, titanium abutments and restoration specimens (n=90) were fabricated. MC, ZC, and ZL materials were prepared with substructure designs A (two-third coverage of the palatal surface) and B (one-third coverage of the palatal surface). After cementation, the specimens were thermocycled (10 000 cycles, 5 and 55 °C). Fracture load measurements, failure mode analysis, energy dispersive X-ray spectroscopy (EDS), line scan analysis, fractography, finite element analysis (FEA), and Weibull analysis were performed. Two-way ANOVA was used to identify the effects of material and substructure design on fracture load. One-way ANOVA was used to identify significant differences of fracture load (α=.05). RESULTS: MC and ZL showed significantly higher fracture load than ZC (P<.05). MC_A showed a significantly higher fracture load than MC_B (P<.05). ZC_A exhibited the lowest Weibull modulus. FEA revealed that the maximum principal stress occurred near the loading area of the veneer. ZL displayed the lowest maximum principal stress among all the materials. CONCLUSIONS: ZL and MC_A exhibited more favorable fracture resistance. The substructure design of MC, with increased metal coverage of the palatal surface, improved fracture resistance significantly.


Assuntos
Coroas , Planejamento de Prótese Dentária , Cerâmica/química , Cerâmica/uso terapêutico , Porcelana Dentária/química , Porcelana Dentária/uso terapêutico , Falha de Restauração Dentária , Análise do Estresse Dentário , Estética Dentária , Teste de Materiais , Zircônio/química
14.
J Prosthet Dent ; 128(6): 1319.e1-1319.e10, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36334990

RESUMO

STATEMENT OF PROBLEM: Studies that compared the fracture strength of monolithic lithium disilicate and 5-mol% yttria partially stabilized zirconia multiunit fixed dental prostheses are sparse. PURPOSE: As the connector is the weakest part of a fixed dental prosthesis, the purpose of this in vitro study was to investigate the effect of connector designs and material on the fracture strength of 3-unit monolithic fixed dental prostheses. MATERIAL AND METHODS: Resin-ceramic canine and premolar teeth (N=144) were prepared for fixed dental prosthesis abutments. Prostheses with 3 connector designs (width=height, widthheight) were made from 2 types of lithium disilicate (IPS e.max CAD and Amber Mill) and 5-mol% yttria partially stabilized zirconia (3M Lava Esthetic and Katana Zirconia UTML). Fracture strengths were measured after 200 000 cycles of dynamic loading of 50 N and thermocycling at 5 °C and 55 °C, and the fracture patterns were analyzed. Two-way analysis of variance and the Fisher exact test were used for statistical analysis (α=.05). RESULTS: The material and connector design affected the fracture strength of fixed dental prostheses (P<.05), and a significant interaction was found between the material and connector design (P<.05). The IPS e.max CAD material had significantly lower fracture strength than Amber Mill, 3M Lava Esthetic, or Katana Zirconia UTML (P<.05). Connector designs with a greater width versus height showed significantly lower fracture strengths than other designs (P<.05). CONCLUSIONS: The connector design of 3-unit fixed dental prostheses, particularly the connector height, may affect fracture strength depending on the prosthesis material.


Assuntos
Implantes Dentários , Falha de Restauração Dentária , Análise do Estresse Dentário , Âmbar , Teste de Materiais , Estética Dentária , Porcelana Dentária , Zircônio , Desenho Assistido por Computador , Cerâmica , Materiais Dentários
15.
Soft Matter ; 17(24): 5888-5896, 2021 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-34027539

RESUMO

Collecting or removing oil drops dispersed in water is essential in a range of industrial processes including oil recovery and oil spill cleanup. However, it is by no means easy to induce merging of oil drops with another body of oil due to slow drainage of the intervening water film. Here, we report immediate coalescence of oil drops with oil films that lie on micropillar arrays as immersed in various aqueous solutions. In addition to experimental demonstrations, we theoretically construct a regime map to predict whether the drop will bounce off or coalesce with the oil film, which is determined by the oil film thickness, geometry of the pillar array and liquid properties. Good agreement between theory and experiment indicates that micropillar arrays provide additional drainage paths of the intervening film, which helps drop-film coalescence. Our results suggest potential implications of utilizing oil-laden microporous structures to achieve efficient demulsification of oil drops in contaminated water.

16.
J Prosthet Dent ; 123(6): 866-873, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31653400

RESUMO

STATEMENT OF PROBLEM: Materials used for dental restorations should cause wear similar to that of natural teeth. Studies on the wear of dental alloys against monolithic zirconia are lacking. PURPOSE: The purpose of this in vitro study was to compare the wear of Co-Cr, gold, and Ni-Cr alloys against monolithic zirconia of different surface roughness. MATERIAL AND METHODS: Cylindrical monolithic zirconia specimens were prepared by a sintering process. Sintered zirconia was then polished to prepare 30 zirconia substrate specimens with a smooth surface (Ra<0.1 µm) and 30 with a rough surface (3.5 µm

Assuntos
Ligas Dentárias , Porcelana Dentária , Esmalte Dentário , Teste de Materiais , Propriedades de Superfície , Zircônio
17.
J Prosthodont ; 29(4): 334-340, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31876065

RESUMO

PURPOSE: To determine the effects of the total thickness and core/veneer thickness ratio of bilayered ceramics on their three-point flexural strength and translucency. MATERIALS AND METHODS: Two groups of specimens were prepared with two different total thicknesses, 1.0 mm and 0.6 mm. These groups were divided into five and three subgroups with ten specimens each, respectively, having different core/veneer thickness ratios. Lithium disilicate was pressed on the zirconia surface using the "lost-wax technique." The translucency and three-point flexural strength were measured, and a one-way analysis of variance test (p < 0.05) was performed to determine whether the translucency and three-point flexural strength were affected by the total thickness and core/veneer thickness ratio of the specimens. RESULTS: For the same total thickness, translucency decreased with a increase in the zirconia core proportion (p < 0.001). For the same core/veneer ratio, the translucency decreased with an increase in the total thickness (p < 0.001). If the zirconia thickness was less than half of the total thickness, the bilayered ceramic specimens containing zirconia cores and monolithic lithium disilicate specimens exhibited a similar translucency. The three-point flexural strength increased with the increasing proportion of zirconia; however, it did not change significantly with the total thickness. However, for the same total thickness, the flexural strengths of the bilayered ceramics were higher than those of the monolithic specimens. CONCLUSIONS: At the same total thickness, increasing the zirconia core thickness decreased the translucency and increased the three-point flexural strength. Bilayered ceramic specimens with low zirconia ratios exhibited translucency similar to that of monolithic lithium disilicate ceramic but a higher flexural strength.


Assuntos
Porcelana Dentária , Resistência à Flexão , Cerâmica , Análise do Estresse Dentário , Teste de Materiais , Propriedades de Superfície , Zircônio
18.
Small ; 15(37): e1900595, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31373770

RESUMO

Although sodium-ion batteries (SIBs) are considered promising alternatives to their Li counterparts, they still suffer from challenges like slow kinetics of the sodiation process, large volume change, and inferior cycling stability. On the other hand, the presence of additional reversible conversion reactions makes the metal compounds the preferred anode materials over carbon. However, conductivity and crystallinity of such materials often play the pivotal role in this regard. To address these issues, atomic layer deposited double-anion-based ternary zinc oxysulfide (ZnOS) thin films as an anode material in SIBs are reported. Electrochemical studies are carried out with different O/(O+S) ratios, including O-rich and S-rich crystalline ZnOS along with the amorphous phase. Amorphous ZnOS with the O/(O+S) ratio of ≈0.4 delivers the most stable and considerably high specific (and volumetric) capacities of 271.9 (≈1315.6 mAh cm-3 ) and 173.1 mAh g-1 (≈837.7 mAh cm-3 ) at the current densities of 500 and 1000 mA g-1 , respectively. A dominant capacitive-controlled contribution of the amorphous ZnOS anode indicates faster electrochemical reaction kinetics. An electrochemical reaction mechanism is also proposed via X-ray photoelectron spectroscopy analyses. A comparison of the cycling stability further establishes the advantage of this double-anion-based material over pristine ZnO and ZnS anodes.

19.
Environ Res ; 172: 194-201, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30802670

RESUMO

Endocrine disrupting chemicals (EDCs) in the environment are considered to be a contributing factor to the decline in the sperm quality. With growing evidence of the harmful effects of EDCs on the male reproductive system, we tested the hypothesis that prenatal exposure to an environmentally relevant phthalate mixture adversely affects reproductive outcomes and androgen synthesis. In this study, an environmentally relevant composition of phthalates (15% DiNP, 21% DEHP, 36% DEP, 15% DBP, 8% DiBP, and 5% BBzP) that were detected in urine samples of pregnant women in Illinois, United States, was used. Pregnant CD-1 mice (F0) were orally dosed with a vehicle or the phthalate mixtures (20 µg/kg/day, 200 µg/kg/day, 200 mg/kg/day, or 500 mg/kg/day) from gestational day 10.5 to the day of birth. Then, the indices of the reproductive function of the F1 males born to these dams were assessed. Those male mice prenatally exposed to the phthalate mixture had smaller gonads, prostates and seminal vesicles, especially in the 20 µg/kg/day and 500 mg/kg/day phthalate mixture groups, compared to the controls. Importantly, at the age of 12 months, those prenatally exposed mice had significantly lower serum testosterone concentrations accompanied by the decreased mRNA expression of testicular steroidogenic genes (StAR, Cyp11, and Cyp17) and impaired spermatogenesis. Taken together, this study found that prenatal exposure to environmentally relevant doses of a phthalate mixture caused a life-long impact on the reproduction in male mice.


Assuntos
Dietilexilftalato , Poluentes Ambientais , Ácidos Ftálicos , Efeitos Tardios da Exposição Pré-Natal , Testosterona , Animais , Poluentes Ambientais/toxicidade , Poluentes Ambientais/urina , Feminino , Regulação da Expressão Gênica/efeitos dos fármacos , Genitália Masculina/efeitos dos fármacos , Humanos , Illinois , Masculino , Camundongos , Ácidos Ftálicos/toxicidade , Ácidos Ftálicos/urina , Gravidez , Testosterona/sangue , Testosterona/metabolismo
20.
Ann Vasc Surg ; 55: 239-245, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30217712

RESUMO

BACKGROUND: Cyanoacrylate closure for the treatment of incompetent saphenous veins does not cause thermal damage and demonstrates satisfactory outcomes with rapid recovery. However, the characteristics of phlebitis-like abnormal reaction (PLAR), the most common adverse event after cyanoacrylate closure, have not been clarified. Moreover, it differs from typical phlebitis after thermal ablation. The objective of our study is to investigate the clinical features of PLAR after cyanoacrylate closure and to report its management. METHODS: A total of 160 patients with 271 incompetent saphenous veins (great saphenous veins, 201; small saphenous veins, 70) underwent cyanoacrylate closure with the VenaSeal™ system. We defined PLAR as any unusual skin condition that develops suddenly, such as erythema, itching, swelling, and pain/tenderness, over the treated veins several days after cyanoacrylate closure. Oral antihistamines and intravenous dexamethasone were administered to manage PLAR. RESULTS: Of the 271 treated veins, 69 experienced PLAR (25.4%). The mean time of occurrence was 13.6 ± 4.6 days after treatment. The rate of occurrence of erythema, itching, swelling, and pain/tenderness were 92.2%, 91.2%, 66.2%, and 48.5%, respectively. The occurrence of PLAR was significantly higher for great saphenous veins than for small saphenous veins (P < 0.001). Occurrences were more frequent in cases with a suprafascial great saphenous vein of length >10 cm than in cases with a subfascial great saphenous vein (P = 0.001). The proportion of patients who reported swelling decreased by more than half after the administration of oral antihistamine. The pain score on the 10th day also decreased significantly after the administration of antihistamine (P = 0.006). CONCLUSIONS: PLAR must be distinguished from classic phlebitis. We believe that PLAR is a type IV hypersensitivity reaction due to a foreign body, and in our experience, antihistamines or steroids are effective for the prevention and management of PLAR.


Assuntos
Cianoacrilatos/efeitos adversos , Reação a Corpo Estranho/induzido quimicamente , Hipersensibilidade Tardia/induzido quimicamente , Flebite/induzido quimicamente , Veia Safena , Adesivos Teciduais/efeitos adversos , Insuficiência Venosa/terapia , Administração Intravenosa , Administração Oral , Adulto , Idoso , Dexametasona/administração & dosagem , Feminino , Reação a Corpo Estranho/diagnóstico por imagem , Reação a Corpo Estranho/tratamento farmacológico , Reação a Corpo Estranho/fisiopatologia , Glucocorticoides/administração & dosagem , Antagonistas dos Receptores Histamínicos/administração & dosagem , Humanos , Hipersensibilidade Tardia/diagnóstico por imagem , Hipersensibilidade Tardia/tratamento farmacológico , Hipersensibilidade Tardia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Flebite/diagnóstico por imagem , Flebite/tratamento farmacológico , Flebite/fisiopatologia , Estudos Prospectivos , Fatores de Risco , Veia Safena/diagnóstico por imagem , Veia Safena/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Insuficiência Venosa/diagnóstico por imagem , Insuficiência Venosa/fisiopatologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA