Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 90(9): 5627-5636, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29579379

RESUMO

Knowledge of the nature of biofluids at a crime scene is just as important as DNA test to link the nature of the biofluid, the criminal act, and the dynamics of the crime. Identification of methods currently used for each biological fluid (blood, semen, saliva, urine) suffer from several limitations including instability of assayed biomolecules, and low selectivity and specificity; as an example of the latter issue, it is not possible to discriminate between alpha-amylase 1 (present in saliva) and alpha-amylase 2 (present in semen and vaginal secretion. In this context, the aim of the work has been to provide a predictive protein signature characteristic of each biofluid by the recognition of specific peptides unique for each protein in a single analysis. A panel of four protein biomarkers for blood, four for saliva, five for semen, and two for urine has been monitored has been monitored by using a single multiple reaction monitoring (MRM)-based method targeting concomitantly 46 different peptides. Then, The optimized method allows four biological matrices to be identified when present on their own or in 50:50 mixture with another biofluid. Finally, a valid strategy combining both DNA analysis and liquid chromatographic-tandem mass spectrometric multiple reaction monitoring (LC-MS-MRM) identification of biofluids on the same sample has been demonstrated to be particularly effective in forensic investigation of real trace evidence collected at a crime scene.


Assuntos
Líquidos Corporais/química , Crime , Ciências Forenses/métodos , Espectrometria de Massas em Tandem/métodos , Apolipoproteínas/análise , Biomarcadores/análise , Glicoproteínas/análise , Humanos , Cadeias kappa de Imunoglobulina , Albumina Sérica Humana/análise , alfa 1-Antitripsina/análise
2.
Rapid Commun Mass Spectrom ; 28(17): 1904-16, 2014 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-25088134

RESUMO

RATIONALE: New psychoactive substances (NPSs) are rapidly spreading worldwide, and forensic laboratories are often requested to identify new substances for which no reference standards or analytical data are available. This article describes an analytical approach that was adopted in Italy by a few collaborative centres of the Italian Early Warning System for Drugs, which has contributed many alerts for the identification of different classes of NPSs in the last 24 months. METHODS: Seized crystals and powders were initially analysed via single quadrupole gas chromatography/mass spectrometry (GC/MS), followed by liquid chromatography/high-resolution mass spectrometry (LC/HRMS) in the positive electrospray ionisation (ESI) mode at 100,000 full width at half maximum resolution (FWHM) without fragmentation to elucidate the elemental compositions of unknown molecules. Different fragmentation voltages during LC/HRMS were applied to study the accurate masses of the obtained characteristic fragments. Nuclear magnetic resonance (NMR) analyses were performed to identify specific isomers when necessary. RESULTS: Some interesting examples of unknown NPSs from seizures later identified in our laboratories are reported, with special focus on those cases where analytical standards were not available during analyses. These cases include cathinones, such as 3-methylmethcathinone (3-MMC), methylone, bk-MBDB (butylone), 4-methylethcathinone (4-MEC), flephedrone, methylenedioxypyrovalerone (MDPV) and pentedrone, methoxetamine, apinaca or AKB48, benzydamine, meta-chlorophenylpiperazine (m-CPP), 5-MeO-N,N-dialkyl tryptamines, such as 5-MeO-DALT and 5-MeOMIPT, benzofurans, such as 6-APB and 4-APB, and diphenidine (identified for the first time in Europe). CONCLUSIONS: The identification of NPSs in confiscated materials was successfully achieved via GC/MS coupled with LC/HRMS and, in a few cases, NMR analyses. The availability of GC/MS libraries is of great assistance in the identification of new drugs. Alternatively, the study of characteristic molecule fragments combined with the determination of their accurate masses can be a useful approach to identify unknown samples not previously analysed.


Assuntos
Drogas Desenhadas/análise , Ciências Forenses/métodos , Psicotrópicos/análise , Alcaloides/análise , Benzofuranos/análise , Cromatografia Líquida , Cromatografia Gasosa-Espectrometria de Massas , Espectroscopia de Ressonância Magnética , Espectrometria de Massas , Piperazinas/análise , Triptaminas/análise
3.
Forensic Sci Int ; 246: 25-30, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25460104

RESUMO

The capability to collect timely information about the substances employed on-site at a crime scene is of fundamental importance during scientific investigations in crimes involving the use of explosives. TNT (2,4,6-trinitrotoluene) is one of the most employed explosives in the 20th century. Despite the growing use of improvised explosives, criminal use and access to TNT is not expected to decrease. Immunoassays are simple and selective analytical tests able to detect molecules and their immunoreactions can occur in portable formats for use on-site. This work demonstrates the application of three immunochemical assays capable of detecting TNT to typical forensic samples from experimental tests: an indirect competitive ELISA with chemiluminescent detection (CL-ELISA), a colorimetric lateral flow immunoassay (LFIA) based on colloidal gold nanoparticles label, and a chemiluminescent-LFIA (CL-LFIA). Under optimised working conditions, the LOD of the colorimetric LFIA and CL-LFIA were 1 µg mL(-1) and 0.05 µg mL(-1), respectively. The total analysis time for LFIAs was 15 min. ELISA proved to be a very effective laboratory approach, showing very good sensitivity (LOD of 0.4 ng mL(-1)) and good reproducibility (CV value about 7%). Samples tested included various materials involved in controlled explosions of improvised explosive devices (IEDs), as well as hand swabs collected after TNT handling tests. In the first group of tests, targets covered with six different materials (metal, plastic, cardboard, carpet fabric, wood and adhesive tape) were fixed on top of wooden poles (180 cm high). Samples of soil from the explosion area and different materials covering the targets were collected after each explosion and analysed. In the second group of tests, hand swabs were collected with and without hand washing after volunteers simulated the manipulation of small charges of TNT. The small amount of solution required for each assay allows for several analyses. Results of immunoassays confirmed that they were suitable to detect post-blast residues in soil and target materials and post transfer residues on hands, allowing further confirmation by more selective techniques. ELISA and LFIAs results obtained from the same solution were consistently in good agreement, and were confirmed by gas chromatography coupled to mass spectrometry (GC-MS). The reported immunoassays data demonstrates the suitability of LFIAs as on-site rapid and effective assays to detect TNT traces. The CL-ELISA proved useful in obtaining very sensitive detection in forensic investigations and testing, while CL-LFIA had performances in between LFIA and CL-ELISA.


Assuntos
Colorimetria , Ensaio de Imunoadsorção Enzimática/métodos , Substâncias Explosivas/análise , Imunoensaio/métodos , Medições Luminescentes/métodos , Trinitrotolueno/análise , Explosões , Ciências Forenses/métodos , Cromatografia Gasosa-Espectrometria de Massas , Mãos , Humanos , Reprodutibilidade dos Testes , Pele/química , Solo/química
4.
Forensic Sci Int ; 216(1-3): 163-7, 2012 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-22071309

RESUMO

The application of diffuse reflectance UV-VIS-NIR spectroscopy is proposed to differentiate 20 office paper samples, which had been deemed similar by a preliminary visual examination under several different lighting sources. The samples were firstly screened on the basis of the qualitative appearance of their spectra. A further discrimination was obtained by taking into account three parameters: the average reflectivity of the paper samples in the range 680-900nm, and the integrated intensity of the absorption peak in the UV range at 272nm and at 360nm. The homogeneity of these parameters on both sides of the paper sheets was assessed, detecting a very uniform distribution of the optical brighteners. A special focus was posed on the determination of the discriminative power, in order to give a quantitative parameter on the proposed procedure, which is important when reporting results to the Court. The remarkable achievement of differentiating all the examined samples was obtained by UV-VIS spectroscopy, a very less expensive technique which is readily available in practically all forensic laboratories.

5.
Forensic Sci Int ; 197(1-3): 70-4, 2010 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-20079986

RESUMO

The possibility to discriminate between sheets of paper can be of considerable importance in questioned document examinations. 19 similar types of office paper were characterized by infrared spectroscopy and X-ray diffraction to individuate the most discriminating features that could be measured by these techniques. The discriminating value associated to them was also assessed. By using a sequence of these two techniques, all the samples could be differentiated.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA