1.
J Loss Prev Process Ind ; 61: 1-7, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31745379

RESUMO

Correctly applied rock dust can dilute, inert, and mitigate the explosive potential of float coal dust. Trickle dusters are one element of a comprehensive system to help prevent coal dust explosions in underground coal mines. Trickle dusters supply rock dust to inert fine float coal dust in areas where it is commonly deposited, such as the longwall tailgate returns, return airways, pillaring areas, and downwind of belt transfers. Dust deposition studies show that the effectiveness of trickle dusters depends on several key factors. Using multiple orifices, rock dust should be released near the mine roof in the direction of the airflow in order to spread the cloud cross the entry. The rock duster should have a mechanism to break up rock dust agglomerates as they leave the rock duster. The particle size distribution of the limestone rock dust and its airborne concentration should be proportional to the airborne size distribution and concentration of coal dust passing by the trickle duster. Specifically, rock dusts having a greater proportion of <74 µm material are more effective at minimizing downwind zones of explosible mixtures than mostly larger particles. In our testing, rock dusts having more than 95% of <74 µm sized particles were adequately dispersed by trickle dusters. Based on our results, the mass rate of rock dust discharge from the trickle duster should exceed the rate of float coal production by at least a factor of four in order to minimize accumulations of explosible dusts.

2.
Fuel (Lond) ; 218: 306-315, 2018 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-29599565

RESUMO

When combustible materials ignite and burn, the potential for fire growth and flame spread represents an obvious hazard, but during these processes of ignition and flaming, other life hazards present themselves and should be included to ensure an effective overall analysis of the relevant fire hazards. In particular, the gases and smoke produced both during the smoldering stages of fires leading to ignition and during the advanced flaming stages of a developing fire serve to contaminate the surrounding atmosphere, potentially producing elevated levels of toxicity and high levels of smoke obscuration that render the environment untenable. In underground mines, these hazards may be exacerbated by the existing forced ventilation that can carry the gases and smoke to locations far-removed from the fire location. Clearly, materials that require high temperatures (above 1400 K) and that exhibit low mass loss during thermal decomposition, or that require high heat fluxes or heat transfer rates to ignite represent less of a hazard than materials that decompose at low temperatures or ignite at low levels of heat flux. In order to define and quantify some possible parameters that can be used to assess these hazards, small-scale laboratory experiments were conducted in a number of configurations to measure: 1) the toxic gases and smoke produced both during non-flaming and flaming combustion; 2) mass loss rates as a function of temperature to determine ease of thermal decomposition; and 3) mass loss rates and times to ignition as a function of incident heat flux. This paper describes the experiments that were conducted, their results, and the development of a set of parameters that could possibly be used to assess the overall fire hazard of combustible materials using small scale laboratory experiments.

3.
J Loss Prev Process Ind ; 54: 103-109, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29681689

RESUMO

The relationship between the explosion inerting effectiveness of rock dusts on coal dusts, as a function of the specific surface area (cm2/g) of each component is examined through the use of 20-L explosion chamber testing. More specifically, a linear relationship is demonstrated for the rock dust to coal dust (or incombustible to combustible) content of such inerted mixtures with the specific surface area of the coal and the inverse of that area of the rock dust. Hence, the inerting effectiveness, defined as above, is more generally linearly dependent on the ratio of the two surface areas. The focus on specific surface areas, particularly of the rock dust, provide supporting data for minimum surface area requirements in addition to the 70% less than 200 mesh requirement specified in 30 CFR 75.2.

4.
J Loss Prev Process Ind ; 39: 7-16, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26834390

RESUMO

Dispersible rock dust must be applied to the surfaces of entries in underground coal mines in order to inert the coal dust entrained or made airborne during an explosion and prevent propagating explosions. 30 CFR. 75.2 states that "… [rock dust particles] when wetted and dried will not cohere to form a cake which will not be dispersed into separate particles by a light blast of air …" However, a proper definition or quantification of "light blast of air" is not provided. The National Institute for Occupational Safety and Health (NIOSH) has, consequently, designed a dust dispersion chamber to conduct quantitative laboratory-scale dispersibility experiments as a screening tool for candidate rock dusts. A reproducible pulse of air is injected into the chamber and across a shallow tray of rock dust. The dust dispersed and carried downwind is monitored. The mass loss of the dust tray and the airborne dust measurements determine the relative dispersibility of the dust with respect to a Reference rock dust. This report describes the design and the methodology to evaluate the relative dispersibility of rock dusts with and without anti-caking agents. Further, the results of this study indicate that the dispersibility of rock dusts varies with particle size, type of anti-caking agent used, and with the untapped bulk density. Untreated rock dusts, when wetted and dried forming a cake that was much less dispersible than the reference rock dust used in supporting the 80% total incombustible content rule.

5.
J Loss Prev Process Ind ; 37: 33-8, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26523092

RESUMO

The Mine Safety and Health Administration (MSHA) specification for rock dust used in underground coal mines, as defined by 30 CFR 75.2, requires 70% of the material to pass through a 200 mesh sieve (<75 µm). However, in a collection of rock dusts, 47% were found to not meet the criteria. Upon further investigation, it was determined that some of the samples did meet the specification, but were inadequate to render pulverized Pittsburgh coal inert in the National Institute for Occupational Safety and Health (NIOSH) Office of Mine Safety and Health Research (OMSHR) 20-L chamber. This paper will examine the particle size distributions, specific surface areas (SSA), and the explosion suppression effectiveness of these rock dusts. It will also discuss related findings from other studies, including full-scale results from work performed at the Lake Lynn Experimental Mine. Further, a minimum SSA for effective rock dust will be suggested.

6.
J Chromatogr Sci ; 53(6): 854-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25452581

RESUMO

Sulfur hexafluoride (SF6) is widely used as a tracer gas because of its detectability at low concentrations. This attribute of SF6 allows the quantification of both small-scale flows, such as leakage, and large-scale flows, such as atmospheric currents. SF6's high detection sensitivity also facilitates greater usage efficiency and lower operating cost for tracer deployments by reducing quantity requirements. The detectability of SF6 is produced by its high molecular electronegativity. This property provides a high potential for negative ion formation through electron capture thus naturally translating to selective detection using negative ion chemical ionization mass spectrometry (NCI-MS). This paper investigates the potential of using gas chromatography (GC) with NCI-MS for the detection of SF6. The experimental parameters for an ultra-trace SF6 detection method utilizing minimal customizations of the analytical instrument are detailed. A method for the detection of parts per trillion (ppt) level concentrations of SF6 for the purpose of underground ventilation tracer gas analysis was successfully developed in this study. The method utilized a Shimadzu gas chromatography with negative ion chemical ionization mass spectrometry system equipped with an Agilent J&W HP-porous layer open tubular column coated with an alumina oxide (Al2O3) S column. The method detection limit (MDL) analysis as defined by the Environmental Protection Agency of the tracer data showed the method MDL to be 5.2 ppt.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Hexafluoreto de Enxofre/análise , Hexafluoreto de Enxofre/química , Monitoramento Ambiental , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA