Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Vascular ; : 17085381231153245, 2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36689328

RESUMO

BACKGROUND: Focal peripheral arterial aneurysms, though rare, have a relatively high association with coexisting synchronous or metachronous aneurysms. While most are asymptomatic at presentation, there is concern for aneurysm thrombosis, embolization, or rupture, which can lead to acute limb ischemia or even limb loss. These complications require early intervention with either open or endovascular surgery, oftentimes staged due to complexity. METHOD: We describe a case of a 65-year-old male presenting with a symptomatic common femoral artery aneurysm with a simultaneous infrarenal abdominal aortic aneurysm, requiring a hybrid endovascular and open approach for operative repair due to the size and characteristics of his aneurysms. DISCUSSION: As the consensus for the management of synchronous/metachronous aneurysms is to stage the procedures, it is important to report scenarios where a single hybrid operation was technically feasible and resulted in good patient outcomes. CONCLUSION: This report supports the role of utilizing multiple hybrid operative techniques to best repair the respective aneurysm in a single operation, with favorable patient outcomes.

2.
J Biomed Phys Eng ; 9(1): 37-50, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30881933

RESUMO

BACKGROUND: Estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. Hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at different depths and field sizes. OBJECTIVE: Determining correction factors (KNR and KNCSF) recommended recently for small field dosimetry formalism by American Association of Physicists in Medicine (AAPM) for different detectors at 6 and 18 MV photon beams. METHODS: EGSnrc Monte Carlo code was used to calculate the doses measured with different detectors located in a slab phantom and the recommended KNR and KNCSF correction factors for various circular small field sizes ranging from 5-30 mm diameters. KNR and KNCSF correction factors were determined for different active detectors (a pinpoint chamber, EDP-20 and EDP-10 diodes) in a homogeneous phantom irradiated to 6 and 18 MV photon beams of a Varian linac (2100C/D). RESULTS: KNR correction factor estimated for the highest small circular field size of 30 mm diameter for the pinpoint chamber, EDP-20 and EDP-10 diodes were 0.993, 1.020 and 1.054; and 0.992, 1.054 and 1.005 for the 6 and 18 MV beams, respectively. The KNCSF correction factor estimated for the lowest circular field size of 5 mm for the pinpoint chamber, EDP-20 and EDP-10 diodes were 0.994, 1.023, and 1.040; and 1.000, 1.014, and 1.022 for the 6 and 18 MV photon beams, respectively. CONCLUSION: Comparing the results obtained for the detectors used in this study reveals that the unshielded diodes (EDP-20 and EDP-10) can confidently be recommended for small field dosimetry as their correction factors (KNR and KNCSF) was close to 1.0 for all small field sizes investigated and are mainly independent from the electron beam spot size.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA