Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Phys Rev Lett ; 106(2): 021303, 2011 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-21405218

RESUMO

Data from the operation of a bubble chamber filled with 3.5 kg of CF3I in a shallow underground site are reported. An analysis of ultrasound signals accompanying bubble nucleations confirms that alpha decays generate a significantly louder acoustic emission than single nuclear recoils, leading to an efficient background discrimination. Three dark matter candidate events were observed during an effective exposure of 28.1 kg day, consistent with a neutron background. This observation provides strong direct detection constraints on weakly interacting massive particle (WIMP)-proton spin-dependent scattering for WIMP masses >20 GeV/c2.

2.
Phys Rev Lett ; 106(13): 131302, 2011 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-21517371

RESUMO

We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from weakly interacting massive particles (WIMPs) with masses below ∼10 GeV/c(2). This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9 GeV/c(2) and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.

3.
Phys Rev Lett ; 107(20): 201803, 2011 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-22181724

RESUMO

The KTeV E799 experiment has conducted a search for the rare decays, K(L)→π(0)π(0)µ(+)µ(-) and K(L)→π(0)π(0)X(0)→π(0)π(0)µ(+)µ(-), where the X(0) is a possible new neutral boson that was reported by the HyperCP experiment with a mass of (214.3 ± 0.5) MeV/c(2). We find no evidence for either decay. We obtain upper limits of Br(K(L)→π(0)π(0)X(0)→π(0)π(0)µ(+)µ(-)) < 1.0 × 10(-10) and Br(K(L)→π(0)π(0)µ(+)µ(-)) < 9.2 × 10(-11) at the 90% confidence level. This result rules out the pseudoscalar X(0) as an explanation of the HyperCP result under the scenario that the dsX(0) coupling is completely real.

4.
Phys Rev Lett ; 103(14): 141802, 2009 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-19905561

RESUMO

We report on the first axion search results from the Cryogenic Dark Matter Search (CDMS) experiment at the Soudan Underground Laboratory. An energy threshold of 2 keV for electron-recoil events allows a search for possible solar axion conversion into photons or local galactic axion conversion into electrons in the germanium crystal detectors. The solar axion search sets an upper limit on the Primakov coupling g(agammagamma) of 2.4x10(-9) GeV-1 at the 95% confidence level for an axion mass less than 0.1 keV/c2. This limit benefits from the first precise measurement of the absolute crystal plane orientations in this type of experiment. The galactic axion search analysis sets a world-leading experimental upper limit on the axioelectric coupling g(aee) of 1.4x10(-12) at the 90% confidence level for an axion mass of 2.5 keV/c2.

5.
Phys Rev Lett ; 99(5): 051804, 2007 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-17930743

RESUMO

The E799-II (KTeV) experiment at Fermilab has collected 83 262 K(L)-->e+ e- gamma(gamma) events above a background of 79 events. We measure a decay width, normalized to the K(L)-->pi0pi0pi(D)0 (pi0-->gammagamma, pi0-->gammagamma, pi(D0-->e+ e- gamma(gamma)) decay width, of Gamma(K(L)-->e+e-gamma(gamma))/Gamma(K(L)-->pi0pi0pi(D)0)=(1.3302+/-0.0046(stat)+/-0.0102(syst)) x 10(-3). We also measure parameters of two K(L)gamma*gamma form factor models. In the Bergström-Massó-Singer parametrization, we find Calpha(K*)= -0.517 +/- 0.030(stat) +/- 0.022(syst). We separately fit for the first parameter of the D'Ambrosio-Isidori-Portolés model and find alpha(DIP)= -1.729 +/- 0.043(stat) +/- 0.028(syst).

6.
Nucl Instrum Methods Phys Res A ; 830: 119-129, 2016 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-27746514

RESUMO

A strip-line and waveform sampling based readout is a signal multiplexing method that can efficiently reduce the readout channels while fully exploiting the fast time characteristics of photo-detectors such as the SiPM. We have applied this readout method for SiPM-based time-of-flight (TOF) positron emission tomography (PET) detectors. We have prototyped strip-line boards in which 8 SiPMs (pitch 5.2 mm) are connected by using a single strip-line, and the signals appearing at the ends of the strip-line are acquired by using the DRS4 waveform sampler at a nominal sampling frequency of 1-5 GS/s. Experimental tests using laser and LYSO scintillator are carried out to assess the performance of the strip-line board. Each SiPM position, which is inferred from the arrival time difference of the two signals at the ends of the strip-line, is well identified with 2.6 mm FWHM resolution when the SiPMs are coupled to LYSO crystals and irradiated by a 22Na source. The average energy and coincidence time resolution responding to 511 keV photons are measured to be ~32% and ~510 ps FWHM, respectively, at a 5.0 GS/s DRS4 sampling rate. The results show that the sampling rate can be lowered to 1.5 GS/s without performance degradation. These encouraging initial test results indicate that the strip-line and waveform sampling readout method is applicable for SiPM-based TOF PET development.

7.
Nucl Instrum Methods Phys Res A ; 784: 557-564, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-25937685

RESUMO

We are developing a time-of-flight Positron Emission Tomography (PET) detector by using silicon photo-multipliers (SiPM) on a strip-line and high speed waveform sampling data acquisition. In this design, multiple SiPMs are connected on a single strip-line and signal waveforms on the strip-line are sampled at two ends of the strip to reduce readout channels while fully exploiting the fast time response of SiPMs. In addition to the deposited energy and time information, the position of the hit SiPM along the strip-line is determined by the arrival time difference of the waveform. Due to the insensitivity of the SiPMs to magnetic fields and the compact front-end electronics, the detector approach is highly attractive for developing a PET insert system for a magnetic resonance imaging (MRI) scanner to provide simultaneous PET/MR imaging. To investigate the feasibility, experimental tests using prototype detector modules have been conducted inside a 9.4 Tesla small animal MRI scanner (Bruker BioSpec 94/30 imaging spectrometer). On the prototype strip-line board, 16 SiPMs (5.2 mm pitch) are installed on two strip-lines and coupled to 2 × 8 LYSO scintillators (5.0 × 5.0 × 10.0 mm3 with 5.2 mm pitch). The outputs of the strip-line boards are connected to a Domino-Ring-Sampler (DRS4) evaluation board for waveform sampling. Preliminary experimental results show that the effect of interference on the MRI image due to the PET detector is negligible and that PET detector performance is comparable with the results measured outside the MRI scanner.

8.
Science ; 153(3740): 1058, 1966 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-17737577
9.
Nucl Instrum Methods Phys Res A ; 767: 67-74, 2014 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-25506113

RESUMO

We have developed a new time calibration method for the DRS4 waveform sampler that enables us to precisely measure the non-uniform sampling interval inherent in the switched-capacitor cells of the DRS4. The method uses the proportionality between the differential amplitude and sampling interval of adjacent switched-capacitor cells responding to a sawtooth-shape pulse. In the experiment, a sawtooth-shape pulse with a 40 ns period generated by a Tektronix AWG7102 is fed to a DRS4 evaluation board for calibrating the sampling intervals of all 1024 cells individually. The electronic time resolution of the DRS4 evaluation board with the new time calibration is measured to be ~2.4 ps RMS by using two simultaneous Gaussian pulses with 2.35 ns full-width at half-maximum and applying a Gaussian fit. The time resolution dependencies on the time difference with the new time calibration are measured and compared to results obtained by another method. The new method could be applicable for other switched-capacitor-array technology-based waveform samplers for precise time calibration.

10.
Science ; 327(5973): 1619-21, 2010 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-20150446

RESUMO

Astrophysical observations indicate that dark matter constitutes most of the mass in our universe, but its nature remains unknown. Over the past decade, the Cryogenic Dark Matter Search (CDMS II) experiment has provided world-leading sensitivity for the direct detection of weakly interacting massive particle (WIMP) dark matter. The final exposure of our low-temperature germanium particle detectors at the Soudan Underground Laboratory yielded two candidate events, with an expected background of 0.9 +/- 0.2 events. This is not statistically significant evidence for a WIMP signal. The combined CDMS II data place the strongest constraints on the WIMP-nucleon spin-independent scattering cross section for a wide range of WIMP masses and exclude new parameter space in inelastic dark matter models.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA