1.
Inhal Toxicol ; 36(1): 44-56, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38343121

RESUMO

Objective: The nasal cavity effectively captures the particles present in inhaled air, thereby preventing harmful and toxic pollutants from reaching the lungs. This filtering ability of the nasal cavity can be effectively utilized for targeted nasal drug delivery applications. This study aims to understand the particle deposition patterns in three age groups: neonate, infant, and adult.Materials and methods: The CT scans are built using MIMICS 21.0, followed by CATIA V6 to generate a patient-specific airway model. Fluid flow is simulated using ANSYS FLUENT 2021 R2. Spherical monodisperse microparticles ranging from 2 to 60 µm and a density of 1100 kg/m3 are simulated at steady-state and sedentary inspiration conditions.Results: The highest nasal valve depositions for the neonate are 25% for 20 µm, for infants, 10% for 50 µm, 15% for adults, and 15% for 15 µm. At mid nasal region, deposition of 15% for 20 µm is observed for infant and 8% for neonate and adult nasal cavities at a particle size of 10 and 20 µm, respectively. The highest particle deposition at the olfactory region is about 2.7% for the adult nasal cavity for 20 µm, and it is <1% for neonate and infant nasal cavities.Discussion and conclusions: The study of preferred nasal depositions during natural sedentary breathing conditions is utilized to determine the size that allows medication particles to be targeted to specific nose regions.


Assuntos
Cavidade Nasal , Nariz , Adulto , Lactente , Recém-Nascido , Humanos , Cavidade Nasal/diagnóstico por imagem , Nariz/diagnóstico por imagem , Tamanho da Partícula
2.
Sensors (Basel) ; 23(7)2023 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-37050750

RESUMO

The continuous monitoring of arterial blood pressure (BP) is vital for assessing and treating cardiovascular instability in a sick infant. Currently, invasive catheters are inserted into an artery to monitor critically-ill infants. Catheterization requires skill, is time consuming, prone to complications, and often painful. Herein, we report on the feasibility and accuracy of a non-invasive, wearable device that is easy to place and operate and continuously monitors BP without the need for external calibration. The device uses capacitive sensors to acquire pulse waveform measurements from the wrist and/or foot of preterm and term infants. Systolic, diastolic, and mean arterial pressures are inferred from the recorded pulse waveform data using algorithms trained using artificial neural network (ANN) techniques. The sensor-derived, continuous, non-invasive BP data were compared with corresponding invasive arterial line (IAL) data from 81 infants with a wide variety of pathologies to conclude that inferred BP values meet FDA-level accuracy requirements for these critically ill, yet normotensive term and preterm infants.


Assuntos
Determinação da Pressão Arterial , Recém-Nascido Prematuro , Lactente , Humanos , Recém-Nascido , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Pressão Arterial , Punho
3.
Sensors (Basel) ; 21(13)2021 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-34206457

RESUMO

This paper reviews recent advances in non-invasive blood pressure monitoring and highlights the added value of a novel algorithm-based blood pressure sensor which uses machine-learning techniques to extract blood pressure values from the shape of the pulse waveform. We report results from preliminary studies on a range of patient populations and discuss the accuracy and limitations of this capacitive-based technology and its potential application in hospitals and communities.


Assuntos
Algoritmos , Determinação da Pressão Arterial , Pressão Sanguínea , Frequência Cardíaca , Humanos , Aprendizado de Máquina
4.
Transfusion ; 60(3): 466-472, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31984520

RESUMO

BACKGROUND: Understanding factors that impact tissue oxygen extraction may guide red blood cell (RBC) transfusion decision making in preterm infants. Our objective was to assess the influence of enteral feeding and anemia on cerebral and mesenteric oxygen saturation (Csat and Msat) and fractional tissue oxygen extraction (cFTOE and mFTOE) over the entire time course of RBC transfusion. STUDY DESIGN AND METHODS: Preterm, very low-birth-weight infants receiving RBC transfusions at a single center were enrolled. Near-infrared spectroscopy sensors measured Csat and Msat levels from an hour before transfusion to 24 hours after. During this period, changes in Csat, Msat, cFTOE, and mFTOE were described, and their association with enteral feeding status and pretransfusion degree of anemia were assessed using generalized estimating equations. RESULTS: RBC transfusion data from 31 preterm infants were included. Infants receiving enteral feeds exhibited lower pretransfusion Msat. Infants with pretransfusion hematocrit greater than 30% exhibited higher pretransfusion Csat and lower pretransfusion cFTOE. Such differences in baseline measurements persisted through 24 hours after transfusion. However, no statistically significant differences in oxygenation measures over time by enteral feeding or anemia status were identified. CONCLUSION: Compared to NPO, enteral feeding was associated with lower Msat; anemia (hematocrit ≤30%) was associated with lower Csat and higher cFTOE. Over the time course of RBC transfusion, trajectories of Csat, Msat, cFTOE and mFTOE did not differ by enteral feeding or anemia status.


Assuntos
Anemia/terapia , Transfusão de Eritrócitos , Peso ao Nascer/fisiologia , Nutrição Enteral , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Espectroscopia de Luz Próxima ao Infravermelho
5.
Artigo em Inglês | MEDLINE | ID: mdl-38884320

RESUMO

Face cups form a vital component of breathing, assisting with devices that aid in artificial breathing for neonates. This study aims to evaluate the flow parameters in the nasal cavity for two different types of face cups. The neonatal nasal cavity model was developed from CT scans using MIMICS 21.0. Two face cups, one hemispherical and the other anatomical shaped cups are developed around the nasal cavity and the airflow is simulated using ANSYS 2021 R2. Results are compared with a nasal-only model. At the nasal valve region, the highest velocity is seen for the nasal-only model which is 16.3% higher than that of the hemispherical face cup and 15.2% superior to the anatomical-shaped face cup. In addition, the decrease in pressure across the nasal-only model is 7.4 and 6.6% below that of the hemispherical cup and anatomical cup masks. The nasal resistance values across the nasal cavity are the lowest for the nasal-only model, 7.7 and 6.7% lower respectively than the hemispherical and anatomical-shaped cups. There were very minor changes in the flow parameters such as velocity, pressure and wall shear stress when comparing the hemispherical and anatomic-shaped masks for the airflow inside the nasal cavity.

7.
Front Pediatr ; 11: 1138062, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36969281

RESUMO

Neonates with hypoxic ischemic encephalopathy (HIE) are at significant risk for adverse outcomes including death and neurodevelopmental impairment. Neuromonitoring provides critical diagnostic and prognostic information for these infants. Modalities providing continuous monitoring include continuous electroencephalography (cEEG), amplitude-integrated electroencephalography (aEEG), near-infrared spectroscopy (NIRS), and heart rate variability. Serial bedside neuromonitoring techniques include cranial ultrasound and somatic and visual evoked potentials but may be limited by discrete time points of assessment. EEG, aEEG, and NIRS provide distinct and complementary information about cerebral function and oxygen utilization. Integrated use of these neuromonitoring modalities in addition to other potential techniques such as heart rate variability may best predict imaging outcomes and longer-term neurodevelopment. This review examines available bedside neuromonitoring techniques for the neonate with HIE in the context of therapeutic hypothermia.

8.
Can J Anaesth ; 59(11): 1023-31, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23055030

RESUMO

INTRODUCTION: Anesthesia information management systems (AIMS) have been developed by multiple vendors and are deployed in thousands of operating rooms around the world, yet not much is known about measuring and improving AIMS usability. We developed a methodology for evaluating AIMS usability in a low-fidelity simulated clinical environment and used it to compare an existing user interface with a revised version. We hypothesized that the revised user interface would be more useable. METHODS: In a low-fidelity simulated clinical environment, twenty anesthesia providers documented essential anesthetic information for the start of the case using both an existing and a revised user interface. Participants had not used the revised user interface previously and completed a brief training exercise prior to the study task. All participants completed a workload assessment and a satisfaction survey. All sessions were recorded. Multiple usability metrics were measured. The primary outcome was documentation accuracy. Secondary outcomes were perceived workload, number of documentation steps, number of user interactions, and documentation time. The interfaces were compared and design problems were identified by analyzing recorded sessions and survey results. RESULTS: Use of the revised user interface was shown to improve documentation accuracy from 85.1% to 92.4%, a difference of 7.3% (95% confidence interval [CI] for the difference 1.8 to 12.7). The revised user interface decreased the number of user interactions by 6.5 for intravenous documentation (95% CI 2.9 to 10.1) and by 16.1 for airway documentation (95% CI 11.1 to 21.1). The revised user interface required 3.8 fewer documentation steps (95% CI 2.3 to 5.4). Airway documentation time was reduced by 30.5 seconds with the revised workflow (95% CI 8.5 to 52.4). There were no significant time differences noted in intravenous documentation or in total task time. No difference in perceived workload was found between the user interfaces. Two user interface design problems were identified in the revised user interface. DISCUSSION: The usability of anesthesia information management systems can be evaluated using a low-fidelity simulated clinical environment. User testing of the revised user interface showed improvement in some usability metrics and highlighted areas for further revision. Vendors of AIMS and those who use them should consider adopting methods to evaluate and improve AIMS usability.


Assuntos
Anestesia , Documentação/métodos , Gestão da Informação/métodos , Gestão da Informação/normas , Interface Usuário-Computador , Comportamento do Consumidor , Interpretação Estatística de Dados , Documentação/normas , Registros de Saúde Pessoal , Humanos , Reprodutibilidade dos Testes , Inquéritos e Questionários , Carga de Trabalho
9.
Semin Fetal Neonatal Med ; 27(5): 101332, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35428591

RESUMO

Clinical Decision Support (CDS) tools help the healthcare team diagnose, monitor, and treat patients more efficiently and consistently by executing clinical practice guidelines and recommendations. As a result, CDS has a direct impact on the delivery and healthcare outcomes. This review covers the fundamental concepts, as well as the infrastructure needed to create a CDS tool and examples of its use in the neonatal setting. This article also serves as a primer on what to think about when proposing the development of a new CDS tool, or when upgrading an existing one. We also highlight important elements that influence CDS development, such as informatics methodologies, data and device interoperability, and regulation.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Recém-Nascido , Humanos , Unidades de Terapia Intensiva Neonatal , Registros Eletrônicos de Saúde , Atenção à Saúde , Equipe de Assistência ao Paciente
10.
Invest Ophthalmol Vis Sci ; 62(1): 20, 2021 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-33475689

RESUMO

Purpose: Obesity is associated with peripheral neuropathy, which bariatric surgery may ameliorate. The aim of this study was to assess whether corneal confocal microscopy can show a change in corneal nerve morphology and keratocyte density in subjects with severe obesity after bariatric surgery. Methods: Twenty obese patients with diabetes (n = 13) and without diabetes (n = 7) underwent assessment of hemoglobin A1c (HbA1c), lipids, IL-6, highly sensitive C-reactive protein (hsCRP), and corneal confocal microscopy before and 12 months after bariatric surgery. Corneal nerve fiber density (CNFD), corneal nerve branch density (CNBD), corneal nerve fiber length (CNFL), and keratocyte density (KD) from the anterior, middle, and posterior stroma were quantified. Twenty-two controls underwent assessment at baseline only. Results: CNFL (P < 0.001), CNBD (P < 0.05), and anterior (P < 0.001), middle (P < 0.001), and posterior (P < 0.001) keratocyte densities were significantly lower in obese patients compared to controls, and anterior keratocyte density (AKD) correlated with CNFL. Twelve months after bariatric surgery, there were significant improvements in body mass index (BMI; P < 0.001), HDL cholesterol (P < 0.05), hsCRP (P < 0.001), and IL-6 (P < 0.01). There were significant increases in CNFD (P < 0.05), CNBD (P < 0.05), CNFL (P < 0.05), and anterior (P < 0.05) and middle (P < 0.001) keratocyte densities. The increase in AKD correlated with a decrease in BMI (r = -0.55, P < 0.05) and triglycerides (r = -0.85, P < 0.001). There were no significant correlations between the change in keratocyte densities and corneal nerve fiber or other neuropathy measures. Conclusions: Corneal confocal microscopy demonstrates early small fiber damage and reduced keratocyte density in obese patients. Bariatric surgery leads to weight reduction and improvement in lipids and inflammation and an improvement in keratocyte density and corneal nerve regeneration.


Assuntos
Cirurgia Bariátrica , Córnea/inervação , Doenças da Córnea/etiologia , Ceratócitos da Córnea/patologia , Obesidade Mórbida/complicações , Nervo Oftálmico/patologia , Adulto , Contagem de Células , Doenças da Córnea/diagnóstico , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 2/complicações , Feminino , Humanos , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Obesidade Mórbida/cirurgia
11.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 4551-4554, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-33019006

RESUMO

Multiple designs of textile-based sensors were developed and integrated into blankets for the measurement of Electrocardiogram (ECG) signals. Once the patient makes direct skin contact with the electrodes, the ECG signals are acquired and transmitted wirelessly by a wireless data acquisition unit to an associated computer for analysis, assessment and storage. A variety of designs and manufacturing methods were tested. An adult human subjects' study was conducted to test the feasibility of these measurements as well as to test the different design types and manufacturing methods. The heart rate and Signal to Noise ratio (SNR) are comparable to the gold standard adhesive lead measurements.


Assuntos
Eletrocardiografia , Têxteis , Adulto , Eletrodos , Humanos , Unidades de Terapia Intensiva , Razão Sinal-Ruído
12.
J Diabetes Sci Technol ; 4(4): 949-57, 2010 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-20663461

RESUMO

BACKGROUND: Studies have indicated that sharing of self-monitoring of blood glucose (SMBG) data and subsequent feedback from the health care provider (HCP) can help achieve glycemic goals such as a reduction in glycated hemoglobin. Electronic SMBG data management and sharing tools for the PC and smartphones may help in reducing the effort to manage SMBG data. METHODS: We reviewed software and top-ranking applications (Apps) for the iPhone platform to document the variety of useful features. Additionally, in an attempt to assess metrics such as task analysis and user friendliness of diabetes Apps, we observed and surveyed patients with diabetes as they recorded and relayed sample SMBG results to their hypothetical HCP using three Apps. RESULTS: Observation and survey demonstrated that the WaveSense Diabetes Manager allowed the participants to complete preselected SMBG data entry and relay tasks faster than other Apps. The survey revealed patient behavior patterns that would be useful in future App development. CONCLUSION: Being able to record, analyze, seamlessly share, and obtain feedback on the SMBG data using an iPhone/iTouch App might potentially benefit patients. Trends in SMBG data management and the possibility of having interoperability of blood glucose monitors and smartphones may open up new avenues of diabetes management for the technologically savvy patient.


Assuntos
Automonitorização da Glicemia/instrumentação , Telefone Celular , Diabetes Mellitus/sangue , Diabetes Mellitus/terapia , Aplicações da Informática Médica , Glicemia/análise , Glicemia/metabolismo , Coleta de Dados , Interpretação Estatística de Dados , Hemoglobinas Glicadas/análise , Pessoal de Saúde , Humanos , Software
13.
J Diabetes Sci Technol ; 4(1): 145-50, 2010 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-20167178

RESUMO

BACKGROUND: Studies have shown that controlling blood glucose can reduce the onset and progression of the long-term microvascular and neuropathic complications associated with the chronic course of diabetes mellitus. Improved glycemic control can be achieved by frequent testing combined with changes in medication, exercise, and diet. Technological advancements have enabled improvements in analytical accuracy of meters, and this paper explores two such parameters to which that accuracy can be attributed. METHODS: Four blood glucose monitoring systems (with or without dynamic electrochemistry algorithms, codeless or requiring coding prior to testing) were evaluated and compared with respect to their accuracy. RESULTS: Altogether, 108 blood glucose values were obtained for each system from 54 study participants and compared with the reference values. The analysis depicted in the International Organization for Standardization table format indicates that the devices with dynamic electrochemistry and the codeless feature had the highest proportion of acceptable results overall (System A, 101/103). Results were significant when compared at the 10% bias level with meters that were codeless and utilized static electrochemistry (p = .017) or systems that had static electrochemistry but needed coding (p = .008). CONCLUSIONS: Analytical performance of these blood glucose meters differed significantly depending on their technologic features. Meters that utilized dynamic electrochemistry and did not require coding were more accurate than meters that used static electrochemistry or required coding.


Assuntos
Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/normas , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/normas , Glicemia/análise , Calibragem , Diabetes Mellitus/sangue , Diabetes Mellitus/tratamento farmacológico , Eletroquímica/instrumentação , Eletroquímica/métodos , Processamento Eletrônico de Dados , Feminino , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Cinética , Masculino , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/normas , Valores de Referência , Reprodutibilidade dos Testes