Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Nano Lett ; 21(24): 10172-10177, 2021 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-34865498

RESUMO

With continued scaling toward higher component densities, integrated circuits (ICs) contain ever greater lengths of nanowire that are vulnerable to failure via electromigration. Previously, plastic electromigration driven by the "electron wind" has been observed, but not the elastic response to the wind force itself. Here we describe mapping, via electron energy-loss spectroscopy, the density of a lithographically defined aluminum nanowire with sufficient precision to determine both its temperature and its internal pressure. An electrical current density of 108 A/cm2 produces Joule heating, tension upwind, and compression downwind. Surprisingly, the pressure returns to its ambient value well inside the wire, where the current density is still high. This spatial discrepancy points to physics that are not captured by a classical "wind force" model and to new opportunities for optimizing electromigration-resistant IC design.


Assuntos
Elétrons
2.
Nature ; 496(7443): 74-7, 2013 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-23535594

RESUMO

Dislocations and their interactions strongly influence many material properties, ranging from the strength of metals and alloys to the efficiency of light-emitting diodes and laser diodes. Several experimental methods can be used to visualize dislocations. Transmission electron microscopy (TEM) has long been used to image dislocations in materials, and high-resolution electron microscopy can reveal dislocation core structures in high detail, particularly in annular dark-field mode. A TEM image, however, represents a two-dimensional projection of a three-dimensional (3D) object (although stereo TEM provides limited information about 3D dislocations). X-ray topography can image dislocations in three dimensions, but with reduced resolution. Using weak-beam dark-field TEM and scanning TEM, electron tomography has been used to image 3D dislocations at a resolution of about five nanometres (refs 15, 16). Atom probe tomography can offer higher-resolution 3D characterization of dislocations, but requires needle-shaped samples and can detect only about 60 per cent of the atoms in a sample. Here we report 3D imaging of dislocations in materials at atomic resolution by electron tomography. By applying 3D Fourier filtering together with equal-slope tomographic reconstruction, we observe nearly all the atoms in a multiply twinned platinum nanoparticle. We observed atomic steps at 3D twin boundaries and imaged the 3D core structure of edge and screw dislocations at atomic resolution. These dislocations and the atomic steps at the twin boundaries, which appear to be stress-relief mechanisms, are not visible in conventional two-dimensional projections. The ability to image 3D disordered structures such as dislocations at atomic resolution is expected to find applications in materials science, nanoscience, solid-state physics and chemistry.

3.
J Power Sources ; 4362019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31824126

RESUMO

Charging a commercial lithium-ion battery intercalates lithium into the graphite-based anode, creating various lithium carbide structures. Despite their economic importance, these structures and the dynamics of their charging-discharging transitions are not well-understood. We have videoed single microcrystals of high-quality, natural graphite undergoing multiple lithiation-delithiation cycles. Because the equilibrium lithium-carbide compounds corresponding to full, half, and one-third charge are gold, red, and blue respectively, video observations give direct insight into both the macromolecular structures and the kinematics of charging and discharging. We find that the transport during the first lithiation is slow and orderly, and follows the core-shell or shrinking annuli model with phase boundaries moving at constant velocities (i.e. non-diffusively). Subsequent lithiations are markedly different, showing transport that is both faster and disorderly, which indicates that the initially pristine graphite is irreversibly and considerably altered during the first cycle. In all cases deintercalation is not the time-reverse of intercalation. These findings both illustrate how lithium enters nearly defect-free host material, and highlight the differences between the idealized case and an actual, cycling graphite anode.

4.
Nature ; 483(7390): 444-7, 2012 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-22437612

RESUMO

Transmission electron microscopy is a powerful imaging tool that has found broad application in materials science, nanoscience and biology. With the introduction of aberration-corrected electron lenses, both the spatial resolution and the image quality in transmission electron microscopy have been significantly improved and resolution below 0.5 ångströms has been demonstrated. To reveal the three-dimensional (3D) structure of thin samples, electron tomography is the method of choice, with cubic-nanometre resolution currently achievable. Discrete tomography has recently been used to generate a 3D atomic reconstruction of a silver nanoparticle two to three nanometres in diameter, but this statistical method assumes prior knowledge of the particle's lattice structure and requires that the atoms fit rigidly on that lattice. Here we report the experimental demonstration of a general electron tomography method that achieves atomic-scale resolution without initial assumptions about the sample structure. By combining a novel projection alignment and tomographic reconstruction method with scanning transmission electron microscopy, we have determined the 3D structure of an approximately ten-nanometre gold nanoparticle at 2.4-ångström resolution. Although we cannot definitively locate all of the atoms inside the nanoparticle, individual atoms are observed in some regions of the particle and several grains are identified in three dimensions. The 3D surface morphology and internal lattice structure revealed are consistent with a distorted icosahedral multiply twinned particle. We anticipate that this general method can be applied not only to determine the 3D structure of nanomaterials at atomic-scale resolution, but also to improve the spatial resolution and image quality in other tomography fields.

5.
Microsc Microanal ; 29(Supplement_1): 1608-1609, 2023 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-37613837
6.
Microsc Microanal ; 29(Supplement_1): 1851-1852, 2023 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-37613897
8.
Nano Lett ; 15(6): 3983-7, 2015 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-25927328

RESUMO

Conductive bridge random access memory (CBRAM) is a leading candidate to supersede flash memory, but poor understanding of its switching process impedes widespread implementation. The underlying physics and basic, unresolved issues such as the connecting filament's growth direction can be revealed with direct imaging, but the nanoscale target region is completely encased and thus difficult to access with real-time, high-resolution probes. In Pt/Al2O3/Cu CBRAM devices with a realistic topology, we find that the filament grows backward toward the source metal electrode. This observation, consistent over many cycles in different devices, corroborates the standard electrochemical metallization model of CBRAM operation. Time-resolved scanning transmission electron microscopy (STEM) reveals distinct nucleation-limited and potential-limited no-growth periods occurring before and after a connection is made, respectively. The subfemtoampere ionic currents visualized move some thousands of atoms during a switch and lag the nanoampere electronic currents.


Assuntos
Óxido de Alumínio/química , Cobre/química , Nanoestruturas/química , Platina/química
9.
Nature ; 503(7476): E1-2, 2013 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-24256806
10.
Proc Natl Acad Sci U S A ; 107(38): 16448-52, 2010 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-20823262

RESUMO

A key challenge for organic electronics research is to develop device models that correctly account for the structural and energetic disorder typically present in such materials. In this paper we report an approach to analyze the electrical performance of an organic electronic device based upon charge extraction measurements of charge densities and transient optoelectronic measurements of charge carrier dynamics. This approach is applied to a poly(3-hexyl thiophene) (P3HT)/6,6 phenyl C61 butyric acid methyl ester (PCBM) blend photovoltaic device. These measurements are employed to determine the empirical rate law for bimolecular recombination losses, with the energetic disorder present in the materials being accounted for by a charge-density-dependent recombination coefficient. This rate law is then employed to simulate the current/voltage curve. This simulation assumes the only mechanism for the loss of photogenerated charges is bimolecular recombination and employs no fitting parameters. Remarkably the simulation is in good agreement with the experimental current/voltage data over a wide range of operating conditions of the solar cell. We thus demonstrate that the primary determinant of both the open-circuit voltage and fill factor of P3HT:PCBM devices is bimolecular recombination. We go on to discuss the applicability of this analysis approach to other materials systems, and particularly to emphasize the effectiveness of this approach where the presence of disorder complicates the implementation of more conventional, voltage-based analyses such as the Shockley diode equation.

11.
Sci Adv ; 9(28): eadg5135, 2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37436993

RESUMO

The lithium-ion battery is currently the preferred power source for applications ranging from smart phones to electric vehicles. Imaging the chemical reactions governing its function as they happen, with nanoscale spatial resolution and chemical specificity, is a long-standing open problem. Here, we demonstrate operando spectrum imaging of a Li-ion battery anode over multiple charge-discharge cycles using electron energy-loss spectroscopy (EELS) in a scanning transmission electron microscope (STEM). Using ultrathin Li-ion cells, we acquire reference EELS spectra for the various constituents of the solid-electrolyte interphase (SEI) layer and then apply these "chemical fingerprints" to high-resolution, real-space mapping of the corresponding physical structures. We observe the growth of Li and LiH dendrites in the SEI and fingerprint the SEI itself. High spatial- and spectral-resolution operando imaging of the air-sensitive liquid chemistries of the Li-ion cell opens a direct route to understanding the complex, dynamic mechanisms that affect battery safety, capacity, and lifetime.

12.
J Am Chem Soc ; 134(22): 9251-62, 2012 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-22632379

RESUMO

Single crystals of doped aniline oligomers are produced via a simple solution-based self-assembly method. Detailed mechanistic studies reveal that crystals of different morphologies and dimensions can be produced by a "bottom-up" hierarchical assembly where structures such as one-dimensional (1-D) nanofibers can be aggregated into higher order architectures. A large variety of crystalline nanostructures including 1-D nanofibers and nanowires, 2-D nanoribbons and nanosheets, 3-D nanoplates, stacked sheets, nanoflowers, porous networks, hollow spheres, and twisted coils can be obtained by controlling the nucleation of the crystals and the non-covalent interactions between the doped oligomers. These nanoscale crystals exhibit enhanced conductivity compared to their bulk counterparts as well as interesting structure-property relationships such as shape-dependent crystallinity. Furthermore, the morphology and dimension of these structures can be largely rationalized and predicted by monitoring molecule-solvent interactions via absorption studies. Using doped tetraaniline as a model system, the results and strategies presented here provide insight into the general scheme of shape and size control for organic materials.

13.
Small ; 8(9): 1415-22, 2012 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-22351509

RESUMO

To study the effects of hydrocarbon precursor gases, graphene is grown by chemical vapor deposition from methane, ethane, and propane on copper foils. The larger molecules are found to more readily produce bilayer and multilayer graphene, due to a higher carbon concentration and different decomposition processes. Single- and bilayer graphene can be grown with good selectivity in a simple, single-precursor process by varying the pressure of ethane from 250 to 1000 mTorr. The bilayer graphene is AB-stacked as shown by selected area electron diffraction analysis. Additionally propane is found to only produce a combination of single- to few-layer and turbostratic graphene. The percent coverage is investgated using Raman spectroscopy and optical, scanning electron, and transmission electron microscopies. The data are used to discuss a possible mechanism for the second-layer growth of graphene involving the different cracking pathways of the hydrocarbons.

14.
Langmuir ; 28(8): 3695-8, 2012 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-22320230

RESUMO

Using scanning transmission electron microscopy we image ~4 nm platinum nanoparticles deposited on an insulating membrane, where the membrane is one of two electron-transparent windows separating an aqueous environment from the microscope's high vacuum. Upon receiving a relatively moderate dose of ~10(4) e/nm(2), initially immobile nanoparticles begin to move along trajectories that are directed radially outward from the center of the field of view. With larger dose rates the particle motion becomes increasingly dramatic. These observations demonstrate that, even under mild imaging conditions, the in situ electron microscopy of aqueous environments can produce electrophoretic charging effects that dominate the dynamics of nanoparticles under observation.


Assuntos
Microscopia Eletrônica de Transmissão e Varredura/métodos , Nanopartículas/química , Nanopartículas/ultraestrutura , Água/química
15.
J Am Chem Soc ; 133(32): 12536-43, 2011 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-21732685

RESUMO

Growth of graphene on copper (100) single crystals by chemical vapor deposition has been accomplished. The atomic structure of the graphene overlayer was studied using scanning tunneling microscopy. A detailed analysis of moiré superstructures present in the graphene topography reveals that growth occurs in a variety of orientations over the square atomic lattice of the copper surface. Transmission electron microscopy was used to elucidate the crystallinity of the grown graphene. Pristine, defect-free graphene was observed over copper steps, corners, and screw dislocations. Distinct protrusions, known as "flower" structures, were observed on flat terraces, which are attributed to carbon structures that depart from the characteristic honeycomb lattice. Continuous graphene growth also occurs over copper adatoms and atomic vacancies present at the single-crystal surface. The copper atom mobility within vacancy islands covered with suspended graphene sheets reveals a weak graphene-substrate interaction. The observed continuity and room-temperature vacancy motion indicates that copper mobility likely plays a significant role in the mechanism of sheet extension on copper substrates. Lastly, these results suggest that the quality of graphene grown on copper substrates is ultimately limited by nucleation at the surface of the metal catalyst.

16.
Phys Rev Lett ; 106(11): 116803, 2011 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-21469887

RESUMO

A model of electrons hopping from atom to atom in graphene's honeycomb lattice gives low-energy electronic excitations that obey a relation formally identical to a 2+1 dimensional Dirac equation. Graphene's spin equivalent, "pseudospin," arises from the degeneracy introduced by the honeycomb lattice's two inequivalent atomic sites per unit cell. Previously it has been thought that the usual electron spin and the pseudospin indexing the graphene sublattice state are merely analogues. Here we show that the pseudospin is also a real angular momentum. This identification explains the suppression of electron backscattering in carbon nanotubes and the angular dependence of light absorption by graphene. Furthermore, it demonstrates that half-integer spin like that carried by the quarks and leptons can derive from hidden substructure, not of the particles themselves, but rather of the space in which these particles live.

18.
Ultramicroscopy ; 222: 113198, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33482467

RESUMO

Total electron yield (TEY) imaging is an established scanning transmission X-ray microscopy (STXM) technique that gives varying contrast based on a sample's geometry, elemental composition, and electrical conductivity. However, the TEY-STXM signal is determined solely by the electrons that the beam ejects from the sample. A related technique, X-ray beam-induced current (XBIC) imaging, is sensitive to electrons and holes independently, but requires electric fields in the sample. Here we report that multi-electrode devices can be wired to produce differential electron yield (DEY) contrast, which is also independently sensitive to electrons and holes, but does not require an electric field. Depending on whether the region illuminated by the focused STXM beam is better connected to one electrode or another, the DEY-STXM contrast changes sign. DEY-STXM images thus provide a vivid map of a device's connectivity landscape, which can be key to understanding device function and failure. To demonstrate an application in the area of failure analysis, we image a 100 nm, lithographically-defined aluminum nanowire that has failed after being stressed with a large current density.

19.
Nature ; 428(6986): 924-7, 2004 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-15118721

RESUMO

The development of manipulation tools that are not too 'fat' or too 'sticky' for atomic scale assembly is an important challenge facing nanotechnology. Impressive nanofabrication capabilities have been demonstrated with scanning probe manipulation of atoms and molecules on clean surfaces. However, as fabrication tools, both scanning tunnelling and atomic force microscopes suffer from a loading deficiency: although they can manipulate atoms already present, they cannot efficiently deliver atoms to the work area. Carbon nanotubes, with their hollow cores and large aspect ratios, have been suggested as possible conduits for nanoscale amounts of material. Already much effort has been devoted to the filling of nanotubes and the application of such techniques. Furthermore, carbon nanotubes have been used as probes in scanning probe microscopy. If the atomic placement and manipulation capability already demonstrated by scanning probe microscopy could be combined with a nanotube delivery system, a formidable nanoassembly tool would result. Here we report the achievement of controllable, reversible atomic scale mass transport along carbon nanotubes, using indium metal as the prototype transport species. This transport process has similarities to conventional electromigration, a phenomenon of critical importance to the semiconductor industry.

20.
ACS Nano ; 14(9): 11510-11517, 2020 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-32790350

RESUMO

More efficient thermoelectric devices would revolutionize refrigeration and energy production, and low-dimensional thermoelectric materials are predicted to be more efficient than their bulk counterparts. But nanoscale thermoelectric devices generate thermal gradients on length scales that are too small to resolve with traditional thermometry methods. Here we fabricate, using single-crystal bismuth telluride (Bi2Te3) and antimony/bismuth telluride (Sb2-xBixTe3) flakes exfoliated from commercially available bulk materials, functional thermoelectric coolers (TECs) that are only 100 nm thick. These devices are the smallest TECs ever demonstrated by a factor of 104. After depositing indium nanoparticles to serve as nanothermometers, we measure the heating and cooling produced by the devices with plasmon energy expansion thermometry (PEET), a high-spatial-resolution, transmission electron microscopy (TEM)-based thermometry technique, demonstrating a ΔT = -21 ± 4 K from room temperature. We also establish proof-of-concept for condensation thermometry, a quantitative temperature-change mapping technique with a spatial precision of ≲300 nm.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA