Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 227
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37957842

RESUMO

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Dilatação , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de Prótese
2.
Cardiovasc Diabetol ; 22(1): 28, 2023 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-36747244

RESUMO

BACKGROUND: Despite paucity of data, it is common practice to discontinue metformin before invasive coronary angiography due to an alleged risk of Metformin-Associated Lactic Acidosis (M-ALA). We aimed at assessing the safety of metformin continuation in diabetic patients undergoing coronary angiography in terms of significant increase in lactate levels. METHODS: In this open-label, prospective, multicentre, single-arm trial, all diabetic patients undergoing coronary angiography with or without percutaneous coronary intervention at 3 European centers were screened for enrolment. The primary endpoint was the increase in lactate levels from preprocedural levels at 72-h after the procedure. Secondary endpoints included contrast associated-acute kidney injury (CA-AKI), M-ALA, and all-cause mortality. RESULTS: 142 diabetic patients on metformin therapy were included. Median preprocedural lactate level was 1.8 mmol/l [interquartile range (IQR) 1.3-2.3]. Lactate levels at 72 h after coronary angiography were 1.7 mmol/l (IQR 1.3-2.3), with no significant differences as compared to preprocedural levels (p = 0.91; median difference = 0; IQR - 0.5 to 0.4 mmol/l). One patient had 72-h levels ≥ 5 mmol/l (5.3 mmol/l), but no cases of M-ALA were reported. CA-AKI occurred in 9 patients (6.1%) and median serum creatinine and estimated glomerular filtration rate remained similar throughout the periprocedural period. At a median follow-up of 90 days (43-150), no patients required hemodialysis and 2 patients died due to non-cardiac causes. CONCLUSIONS: In diabetic patients undergoing invasive coronary angiography, metformin continuation throughout the periprocedural period does not increase lactate levels and was not associated with any decline in renal function. TRIAL REGISTRATION: The study was registered at Clinicaltrials.gov (NCT04766008).


Assuntos
Acidose Láctica , Injúria Renal Aguda , Diabetes Mellitus , Metformina , Humanos , Acidose Láctica/induzido quimicamente , Acidose Láctica/diagnóstico , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Angiografia Coronária/efeitos adversos , Diabetes Mellitus/induzido quimicamente , Hipoglicemiantes/efeitos adversos , Lactatos , Metformina/efeitos adversos , Estudos Prospectivos
3.
Catheter Cardiovasc Interv ; 102(6): 1020-1033, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37855169

RESUMO

BACKGROUND: Diabetic patients are at higher risk of recurrent adverse events following percutaneous coronary intervention (PCI) than the nondiabetics. Despite the introduction of new generation drug-eluting stents, their efficacy in the diabetics is still limited. AIMS: To evaluate the efficacy of the Abluminus DES+ biodegradable polymer sirolimus-eluting stent in reducing neointimal hyperplasia in diabetic patients, compared to a durable polymer everolimus-eluting stent (DP-EES). METHODS: A total of 131 patients with diabetes and coronary artery disease were enrolled in six Italian centers and randomized in a 2:1 fashion to PCI with Abluminus DES+ or DP-EES: 85 were assigned to Abluminus DES+ and 46 to DP-EES. The primary endpoint was optimal coherence tomography (OCT)-derived neointimal volume at 9-12 months. Secondary endpoints included OCT-derived neointimal area, neointimal volume obstruction and adverse clinical events. RESULTS: The primary endpoint, neointimal volume, did not differ between Abluminus DES+ and DP-EES (29.11 ± 18.90 mm3 vs. 25.48 ± 17.04 mm3 , p = 0.40) at 9-12-month follow-up. This finding remained consistent after weighing for the sum of stents lengths (1.14 ± 0.68 mm3 vs. 0.99 ± 0.74 mm3 for Abluminus DES+ and DP-EES, respectively, p = 0.38). Similarly, other OCT-derived and clinical secondary endpoints did not significantly differ between the two groups. Rate of target lesion failure was high in both groups (21.2% for Abluminus DES+ and 19.6% for DP-EES). CONCLUSIONS: This preliminary study failed to demonstrate the superiority of the Abluminus DES+ over the DP-EES in diabetic patients in terms of neointimal proliferation.


Assuntos
Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Implantes Absorvíveis , Everolimo/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Sirolimo/efeitos adversos , Tomografia de Coerência Óptica , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 101(5): 911-917, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36856010

RESUMO

BACKGROUND: Chronic total occlusion (CTO) revascularization is a major source of radiation for both patients and physicians. Therefore, efforts to minimize radiation during CTO percutaneous coronary intervention (PCI) are highly encouraged. AIMS: To evaluate the impact of an Ultra Low fluoroscopic Dose Protocol (ULDP), based on 3.75 frames per second for the fluoroscopy and 7.5 frames per second for the cine acquisition, during CTO PCI. METHODS: One hundred fifty consecutive patients who underwent CTO PCI were retrospectively enrolled. Eighty-five underwent standard dose protocol (SDP) and 65 ULDP. Radiation exposure and acute clinical outcomes were compared between groups. Results were stratified according to lesion complexity. RESULTS: Patients undergoing ULDP, as compared to those undergoing SDP, showed a significant reduction of kerma area product, both for simple lesions (6861.0 vs. 13236.0 mGy × cm2 ; p = 0.014) and complex lesions (CL) (8865.0 vs. 16618.0 mGy × cm2 ; p < 0.001). Similarly, Air Kerma (AK) was lower when ULDP was used (1222.5 vs. 2015.0 cGy in SL, p = 0.134; 1499.0 vs. 2794.0 cGy in CL, p < 0.001). No significant differences were reported regarding procedural success and in-hospital major adverse cardiovascular events between groups. Notably, there was not any crossover from ULDO to SDP due to poor quality images. Interestingly, fluoroscopy time, procedural time and contrast volume was significantly lower in patients undergoing ULDP only for CLs. CONCLUSIONS: ULDP significantly reduces radiation exposure in the setting of high complexity procedures such as CTO PCI. This reduction seemed to be greater with increased procedural complexity and did not impact acute success or adverse clinical events.


Assuntos
Oclusão Coronária , Fluoroscopia , Intervenção Coronária Percutânea , Humanos , Doença Crônica , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Oclusão Coronária/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 101(4): 798-805, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36841945

RESUMO

OBJECTIVES: The objective of this study is to investigate the use of cutting balloon (CB) inflated at high pressure compared with noncompliant balloon (NCB) for the treatment of calcified coronary lesions. BACKGROUND: No data are available regarding the safety and efficacy of CB inflated at high pressure in coronary artery calcifications. METHODS: Patients with calcified lesions (more than 100° of calcium demonstrated at baseline intravascular ultrasound) were randomized. Primary endpoint of the study was the final minimal stent area (MSA) and stent symmetry in the calcific segment. Secondary endpoints included rate of device failure and the 1-year rate of target lesion revascularization, target vessel revascularization, and major adverse cardiovascular events. RESULTS: From September 2019 to June 2021, a total of 100 patients were included and randomized; 13 patients were excluded for major protocol deviations. Lesions were complex (type B2/C n = 61 [71.2%]) with a mean arch of calcium of 266 ± 84°, a calcium length of 12 ± 6.6 mm. CB was inflated at comparable atmospheres when compared with NCB (18.3 ± 5 vs. 19 ± 4.5, p = 0.46). In the per-protocol population, the final MSA at the level of the calcium site was significantly higher in the CB group (8.1 ± 2 vs. 7.3 ± 2.1, p = 0.035) with a higher eccentricity index achieved in the CB group (0.84 ± 0.07 vs. 0.8 ± 0.08, p = 0.013). Three device failure occurred in the CB group. One-year follow-up outcomes were comparable. CONCLUSIONS: Treatment of calcified lesions with high-pressure CB has a good safety profile and is associated with a larger MSA and higher eccentricity of the stent at the level of the calcium site compared with NCB.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Humanos , Angiografia Coronária , Cálcio , Resultado do Tratamento , Doença da Artéria Coronariana/terapia , Stents
6.
Catheter Cardiovasc Interv ; 102(5): 931-943, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37668097

RESUMO

BACKGROUND: Evidence of clinical impact of PPM after TAVI is conflicting and might vary according to the type of valve implanted. AIMS: To assess the clinical impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) with balloon-expandable (BEV) and self-expandable valves (SEV) in patients with small annuli. METHODS: TAVI-SMALL 2 enrolled 628 patients in an international retrospective registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 ) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Analyses were performed comparing patients with less than moderate (n = 452), moderate (n = 138), and severe PPM (n = 38). Primary endpoint was incidence of all-cause mortality. Predictors of all-cause mortality and PPM were investigated. RESULTS: At a median follow-up of 380 days (interquartile range: 210-709 days), patients with severe PPM, but not moderate PPM, had an increased risk of all-cause mortality when compared with less than moderate PPM (log-rank p = 0.046). Severe PPM predicted all-cause mortality in patients with BEV (hazard ratio [HR]: 5.20, 95% confidence interval [CI]: 1.27-21.2) and intra-annular valves (IAVs, HR: 4.23, 95% CI: 1.28-14.02), and it did so with borderline significance in the overall population (HR: 2.89, 95% CI: 0.95-8.79). Supra-annular valve (SAV) implantation was the only predictor of severe PPM (odds ratio: 0.33, 95% CI: 0.13-0.83). CONCLUSIONS: Patients with small aortic annuli and severe PPM after TAVI have an increased risk of all-cause mortality at early term follow-up, especially after IAV or BEV implantation. TAVI with SAV protected from severe PPM.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estudos Retrospectivos , Desenho de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos
7.
Catheter Cardiovasc Interv ; 102(6): 1048-1056, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37933728

RESUMO

BACKGROUND: Percutaneous treatment for ostial left circumflex artery (LCx) lesions is known to be associated with suboptimal results. AIMS: The present study aims to assess the procedural and long-term clinical outcomes of percutaneous coronary intervention (PCI) for de novo ostial LCx lesions overall and according to the coronary revascularization strategy. METHODS: Consecutive patients undergoing PCI with second generation drug eluting stents or drug coated balloons for de novo ostial LCx lesions in three high-volume Italian centers between 2012 and 2021 were retrospectively evaluated. The primary endpoint was target-vessel revascularization (TVR) at 2 years. Secondary endpoints included major adverse cardiovascular and cerebrovascular events (MACCE), target lesion revascularization, myocardial infarction, stroke, all-cause death, and repeat revascularization. RESULTS: A total of 366 patients were included in the analysis with a median follow-up of 901 (IQR: 450-1728) days. 79.5% of the patients were male, 33.6% were diabetic, 49.7% had a previous PCI, and 23.1% a prior surgical revascularization. Very ostial LCx stenting was performed in 34.1%, crossover from left main to LCx in 17.3%, and a two-stent strategy in 48.6% of cases, respectively. In the overall population, the incidence of TVR at 2 years was 19.0% while MACCE rate was 25.7%. No major differences in clinical outcomes were found according to the stenting strategy. Use of intracoronary imaging was associated with fewer MACCE (HR: 0.47, 95% CI: 0.25-1.13, p = 0.01), while the diameter of the stent implanted in the ostial LCx was associated with less TVR (HR: 0.43, 95% CI: 0.25-0.75, p = 0.002). CONCLUSIONS: Percutaneous revascularization of the ostial LCx is associated with a high rate of TVR, regardless of the stenting strategy. Intracoronary imaging and proper stent sizing may reduce the failure rates.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Resultado do Tratamento , Angiografia Coronária/métodos
8.
Rev Cardiovasc Med ; 23(2): 76, 2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35229567

RESUMO

Tricuspid regurgitation (TR) has a considerable prevalence in the overall population, that further increases in selected categories of patients. Three morphologic types of TR prevail, namely primary, secondary and atrial TR, mostly, but not always, occurring in different subsets of patients. Recent evidences demonstrate a negative impact of TR on outcomes, irrespective of etiology and even when less than severe in grading. Unfortunately, current surgical standards are void of strong prospective evidence of positive impact on clinical outcomes. While on one hand recent advances in diagnosis and risk stratification of patients with TR are shedding light onto the population that may benefit from intervention and its appropriate timing, on the other hand the arrival on stage of percutaneous treatment options is widening even more the therapeutic options for such population. In this review we will address and discuss the available evidence on the prognostic impact of TR in different clinical contexts encountered in practice.


Assuntos
Insuficiência da Valva Tricúspide , Humanos , Prognóstico , Estudos Prospectivos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/terapia
9.
Catheter Cardiovasc Interv ; 99(3): 827-835, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34783423

RESUMO

OBJECTIVES: To compare incidence of forearm radial artery occlusion (RAO) and hemostasis characteristics between distal and conventional transradial approach (DRA and TRA, respectively). BACKGROUND: DRA has the potential advantage of reducing RAO. DRA effectively reduces time-to-hemostasis, however its role on preserving flow in the radial artery (PF) during hemostasis and consequent impact on RAO remains speculative. METHODS: Eight hundred thirty-seven patients with TRA were previously enrolled in a prospective registry investigating the relationship of residual anticoagulation and RAO. Three hundred twenty-six additional patients with DRA were added to the cohort and matched to the original cohort by propensity score. The composite end-point of RAO at forearm and distal site of puncture (dRAO) was evaluated as secondary end-point. RESULTS: RAO occurred in 4.8% (41 of 837) of patients undergoing TRA and in 0% (0 of 326) of those undergoing DRA (p < 0.0001). DRA was associated with higher percentage of PF (97.2% vs. 78.5% in TRA group, p < 0.0001) and reduced time-to-hemostasis (147 ± 99 min vs. 285 ± 138 min, p < 0.0001). After matching, hemostasis characteristics were still significant different (PF 95.7% vs. 90.1%, p = 0.023, and 190 ± 92 vs. 323 ± 162 min, p < 0.0001) with reduction in the incidence of RAO (0 of 213, 0% vs. 7 of 213, 3.3%, p = 0.0015). dRAO occurred in one case (0.3% and 0.5% after matching, p < 0.0001 and p = 0.032 compared to TRA). CONCLUSIONS: DRA was associated with lower rates of RAO compared to TRA. This effect is potentially explained by reduced time-to-hemostasis and maintained flow at the wrist during hemostasis.


Assuntos
Arteriopatias Oclusivas , Cateterismo Periférico , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/epidemiologia , Arteriopatias Oclusivas/etiologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Periférico/efeitos adversos , Hemostasia , Humanos , Pontuação de Propensão , Estudos Prospectivos , Artéria Radial/diagnóstico por imagem , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 99(6): 1766-1777, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35312151

RESUMO

INTRODUCTION: Device entrapment is a life-threatening complication during percutaneous coronary intervention (PCI). However, the success for its management is predominantly based on operator experience with limited available guidance in the published literature. METHODS: A systematic review was performed on December 2021; we searched PubMed for articles on device entrapment during PCI. In addition, backward snowballing (i.e., review of references from identified articles and pertinent reviews) was employed. RESULTS: A total of 4209 articles were retrieved, of which 150 studies were included in the synthesis of the data. A methodical algorithmic approach to prevention and management of device entrapment can help to optimize outcomes. The recommended sequence of steps are as follows: (a) pulling, (b) trapping, (c) snaring, (d) plaque modification, (e) telescoping, and (f) surgery. CONCLUSIONS: In-depth knowledge of the techniques and necessary tools can help optimize the likelihood of successful equipment retrieval and minimization of complications.


Assuntos
Intervenção Coronária Percutânea , Placa Aterosclerótica , Humanos , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 100(5): 903-909, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36040688

RESUMO

OBJECTIVES: To report the experience of a high-volume center with balloon-expandable (BE) stents implantation to manage vascular complications after transcatheter aortic valve replacement (TAVR). BACKGROUND: Despite increased operator experience and better devices, vascular complications after TAVR are still a major issue and covered stent implantation is often required. METHODS: We retrospectively collected baseline and procedural data about 78 consecutive patients who underwent BE stent implantation to manage a vascular complication after transfemoral TAVR. Primary endpoints were technical success, incidence of new-onset claudication and need for vascular interventions during long-term follow-up. Secondary endpoints included length of hospitalization, in-hospital and 30-day mortality, and major postoperative complications. RESULTS: BE stents implantation to manage vascular complications after TAVR was successfully performed in 96.2% of the cases, with bailout surgery required in two cases. One patient suffered in-hospital death. Predischarge Doppler Ultrasound revealed no cases of in-stent occlusion or fracture. At a median follow-up of 429 days (interquartile range, 89-994 days), no cases of symptomatic leg ischemia were reported and only one patient experienced new-onset claudication. CONCLUSIONS: Our experience showed good periprocedural and long-term results of BE covered stent implantation to manage vascular complication after TAVR. Their great radial outward force may guarantee effective hemostasis without necessarily being associated with stent deformation/fracture resulting in restenosis or further interventions. More research is needed to define the role of BE covered stents in this setting.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Doenças Vasculares , Humanos , Seguimentos , Estudos Retrospectivos , Mortalidade Hospitalar , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Resultado do Tratamento , Stents , Doenças Vasculares/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
12.
Catheter Cardiovasc Interv ; 100(4): 620-627, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35842775

RESUMO

OBJECTIVES: To assess feasibility and safety of second-generation left atrial appendage closure (LAAC) Ultraseal device in patients with nonvalvular atrial fibrillation (NVAF). BACKGROUND: LAAC with first-generation Ultraseal device (Cardia, Eagan, Minnesota) has been shown to be a feasible therapeutic option in patients with NVAF. However, there is a paucity of data regarding the novel second-generation Ultraseal device. METHODS: All patients with NVAF undergoing second-generation Ultraseal device implantation between February 2018 and September 2020 were included in a multicenter international registry. Periprocedural and post-discharge events were collected through 6-month follow-up. Co-primary efficacy endpoints were device success and technical success while primary safety endpoint was in-hospital major adverse event (MAE) occurrence. RESULTS: A total of 52 patients were included: mean age 75 ± 8, 30.8% women, mean HAS-BLED 3 ± 1. The device was successfully implanted in all patients. Technical success was achieved in 50 patients (96.1%). In-hospital MAEs occurred in three patients (5.8%). The incidence of 6-month all-cause death and major bleeding was 11.6% and 2.1%, respectively. No strokes, transient ischemic attacks, systemic embolisms, or device embolization were reported after discharge. CONCLUSIONS: Second-generation Ultraseal device implantation was associated with high success rates and a low incidence of peri-procedural complications. Larger studies with longer follow-up are warranted to further evaluate the safety and the efficacy of this device, especially at long-term follow-up.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Assistência ao Convalescente , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Feminino , Humanos , Masculino , Alta do Paciente , Sistema de Registros , Resultado do Tratamento
13.
J Cardiovasc Pharmacol ; 80(1): 140-147, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35436244

RESUMO

ABSTRACT: Despite large-scale randomized clinical trials (RCTs) highlighting a consistent prognostic benefit of sodium-glucose cotransporter 2 inhibitors (SGLT2is) both in diabetic patients at high cardiovascular risk and in those with heart failure, there is relative paucity of data on their biochemical effects in a real-world setting. We performed a retrospective analysis on consecutive diabetic patients who were prescribed a SGLT2i in a tertiary referral center and completed at least 1 year of treatment. Changes in glycated hemoglobin, weight, and hematocrit were compared across 2 cardiovascular risk categories, defined through the inclusion criteria of 3 large RCTs. Of the 459 patients screened, 312 completed 1 year of treatment (68.0%), 92 interrupted the treatment prematurely (20.0%), and 55 were lost to follow-up (12.0%). The most common cause of drug discontinuation was genital or urinary tract infections (9.4%). At 1 year, reduction in glycated hemoglobin concentration (-0.7 ± 1.5%, P < 0.001) and body weight (2.4 ± 4.6 kg, P < 0.001) was comparable between patients at high versus low cardiovascular risk, while hematocrit increase (2.3 ± 3.3%, P < 0.001) was more marked in patients with high cardiovascular risk and low baseline hematocrit. In a real-world population of diabetic patients, SGLT2is were well-tolerated at 1 year and led to improved glycemic control and weight loss. Hematocrit increase was more consistent in patients with high cardiovascular risk and signs of fluid overload, indicating euvolemic restoration as a potential cardioprotective mechanism mediated by these compounds.


Assuntos
Diabetes Mellitus Tipo 2 , Insuficiência Cardíaca , Inibidores do Transportador 2 de Sódio-Glicose , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Glucose , Hemoglobinas Glicadas , Fatores de Risco de Doenças Cardíacas , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Sódio , Inibidores do Transportador 2 de Sódio-Glicose/uso terapêutico
15.
Lancet ; 395(10235): 1487-1495, 2020 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-32386592

RESUMO

BACKGROUND: Antiplatelet therapy is recommended among patients with established atherosclerosis. We compared monotherapy with a P2Y12 inhibitor versus aspirin for secondary prevention. METHODS: In this systematic review and meta-analysis, all randomised trials comparing P2Y12 inhibitor with aspirin monotherapy for secondary prevention in patients with cerebrovascular, coronary, or peripheral artery disease were evaluated for inclusion. On Dec 18, 2019, we searched PubMed, Embase, BioMedCentral, Google Scholar, and the Cochrane Central Register of Controlled Trials. Additionally, we reviewed references from identified articles and searched abstracts from 2017 to 2019 presented at relevant scientific meetings. Data about year of publication, inclusion and exclusion criteria, sample size, baseline patients' features including the baseline condition determining study inclusion (ie, cerebrovascular, coronary, or peripheral artery disease), P2Y12 inhibitor type and dosage, aspirin dosage, endpoint definitions, effect estimates, follow-up duration, and percentage of patients lost to follow-up were collected. Odds ratios (ORs) and 95% CIs were used as metric of choice for treatment effects with random-effects models. Co-primary endpoints were myocardial infarction and stroke. Key secondary endpoints were all-cause death and vascular death. Heterogeneity was assessed with the I2 index. This study is registered with PROSPERO (CRD42018115037). FINDINGS: A total of nine randomised trials were identified and included in this study, and 42 108 patients randomly allocated to a P2Y12 inhibitor (n=21 043) or aspirin (n=21 065) were included in our analyses. Patients who received a P2Y12 inhibitor had a borderline reduction for the risk of myocardial infarction compared with those who received aspirin (OR 0·81 [95% CI 0·66-0·99]; I2=10·9%). Risks of stroke (OR 0·93 [0·82-1·06]; I2=34·5%), all-cause death (OR 0·98 [0·89-1·08]; I2=0%), and vascular death (OR 0·97 [0·86-1·09]; I2=0%) did not differ between patients who received a P2Y12 inhibitor and those who received aspirin. Similarly, the risk of major bleeding (OR 0·90 [0·74-1·10]; I2=3·9%) did not differ between patients who received a P2Y12 inhibitor and those who received aspirin. The number needed to treat to prevent one myocardial infarction with P2Y12 inhibitor monotherapy was 244 patients. Findings were consistent regardless of the type of P2Y12 inhibitor used. INTERPRETATION: Compared with aspirin monotherapy, P2Y12 inhibitor monotherapy is associated with a risk reduction for myocardial infarction and a comparable risk of stroke in the setting of secondary prevention. The benefit of P2Y12 inhibitor monotherapy is of debatable clinical relevance, in view of the high number needed to treat to prevent a myocardial infarction and the absence of any effect on all-cause and vascular mortality. FUNDING: Italian Ministry of Education.


Assuntos
Aspirina/uso terapêutico , Aterosclerose/tratamento farmacológico , Clopidogrel/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Antagonistas do Receptor Purinérgico P2Y/uso terapêutico , Ticagrelor/uso terapêutico , Ticlopidina/uso terapêutico , Idoso , Aterosclerose/complicações , Transtornos Cerebrovasculares/tratamento farmacológico , Doença das Coronárias/tratamento farmacológico , Feminino , Hemorragia/induzido quimicamente , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/prevenção & controle , Doença Arterial Periférica/tratamento farmacológico , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Prevenção Secundária/métodos , Acidente Vascular Cerebral/prevenção & controle
16.
Catheter Cardiovasc Interv ; 98(1): 66-75, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32592437

RESUMO

OBJECTIVES AND BACKGROUND: There is conflicting evidence about the effects of drug-coated balloons (DCB) compared with drug-eluting stents (DES) in patients with native small vessel coronary artery disease (CAD). METHODS: The PubMed, Embase, Cochrane Central Register of Controlled Trials, and ClinicalTrials.gov databases and main international conference proceedings were searched for randomized controlled trials (RCT) comparing DCB versus DES in patients with native small vessel CAD. Data were pooled by meta-analysis using a random-effects model. The primary endpoint was target vessel revascularization (TVR). Secondary clinical endpoints were: myocardial infarction (MI), target lesion revascularization (TLR), all-cause death, cardiac death, and stent thrombosis or target vessel thrombosis. Secondary angiographic outcomes were: in-segment restenosis, in-segment percentage-diameter stenosis, in-segment late lumen loss, in-segment net luminal gain, and in-segment minimal lumen diameter. RESULTS: Five trials enrolling 1,459 patients were included. Mean clinical follow-up was 10.2 months. The use of DCB, compared with DES, was associated with similar risk of TVR (odds ratio [OR]: 0.97; 95% confidence interval [CI] 0.56 to 1.68; p = .92), TLR (OR: 1.74; 95% CI: 0.57 to 5.28; p = .33), all-cause death (OR: 1.03; 95% CI: 0.14 to 7.48; p = .98), with a trend toward a lower risk of MI (OR: 0.49; 95% CI: 0.23 to 1.03; p = .06), and with significant lower risk of vessel thrombosis (OR: 0.12; 95% CI: 0.01 to 0.94; p = .04). DCB use was associated with similar risk of angiographic restenosis (OR: 1.12; 95% CI 0.69 to 1.84; p = .64), comparable late luminal loss (standardized mean difference (SMD): -0.18; 95% CI: -0.39 to 0.03; p = .09), while leading to significant higher percentage diameter stenosis (SMD: 0.27; 95% CI 0.12 to 0.41; p < .01) and smaller minimal luminal diameter (SMD: -0.52; 95% CI: -0.86 to -0.18; p = .003). CONCLUSION: Compared with DES, the use of DCB for the treatment of native small vessel CAD is associated with similar TVR and restenosis and reduces the risk of vessel thrombosis, although DES implantation yields slightly better angiographic surrogate endpoints.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Preparações Farmacêuticas , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Resultado do Tratamento
17.
Catheter Cardiovasc Interv ; 97(7): 1369-1376, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32761864

RESUMO

OBJECTIVES: To assess the independent predictors of patent and occlusive hemostasis (PH and OH, respectively) during radial hemostasis after coronary procedures. BACKGROUND: Radial artery occlusion (RAO) is a thrombotic complication of transradial catheterization that can lead to permanent occlusion of the radial artery. Sheath-vessel diameter ratio, postprocedure compression time, occlusive hemostasis, inadequate, and excessive anticoagulation are all predictors of RAO. METHODS: As a part of a previously published study investigating the relationship between residual anticoagulation and risk of RAO, 837 patients undergoing transradial diagnostic coronary angiography or percutaneous coronary interventions were enrolled. Cumulative heparin dose used during the procedure and ACT measured before sheath removal were recorded. PH with reverse Barbeau test was attempted in all patients (NCT02762344). RESULTS: PH was less frequently obtained for increasing cumulative heparin dose and ACT values (p < .0001 and p = .0034, respectively). At logistic regression analysis both cumulative heparin dose and ACT values were independent predictors of OH (OR 1.017, 95% IC 1.011-1.023 p < .0001 and OR 1.004, 95% IC 1.001-1.006, p = .0004) while adjusted probability for RAO showed exponential relationship with both parameters. CONCLUSIONS: The level of anticoagulation is strongly related to the incidence of RAO, and should be taken into account when choosing hemostasis protocol.


Assuntos
Arteriopatias Oclusivas , Artéria Radial , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/etiologia , Cateterismo Cardíaco/efeitos adversos , Angiografia Coronária/efeitos adversos , Hemostasia , Heparina/efeitos adversos , Humanos , Artéria Radial/diagnóstico por imagem , Resultado do Tratamento
18.
Catheter Cardiovasc Interv ; 98(3): 595-604, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33586278

RESUMO

BACKGROUND: Valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) is an emerging alternative to re-do surgery. However, the challenge of coronary access (CA) following ViV-TAVR is a potential limitation as TAVR expands to younger lower-risk populations. OBJECTIVES: Using post-implantation computed tomography (CT) scans to evaluate the geometrical relationship between coronary ostia and valve frame in patients undergoing ViV-TAVR with the ACURATE neo valve. METHODS: Post-implant CT scans of 18 out of 20 consecutive patients treated with the ACURATE neo valve were analyzed. Coronary ostia location in relation to the highest plane (HP) (highest point of the ACURATE neo or surgical valve) was determined. Ostia located below the highest plan were further subclassified according to the gap available between the transcatheter heart valve frame and ostium (transcatheter-to-coronary [TTC] distance). The impact implantation depth has on these geometrical relationships was evaluated. RESULTS: A total of 21 out of 36 coronary ostia (58%) were located below the level of the HP with the left coronary artery (36%) more likely to be affected than the right (22%). Further sub-classification of these ostia revealed a large (>6 mm), moderate (4-6 mm), and small (<4 mm) TTC distance in 57% (12/21), 38% (8/21), and in 6% (1/18) of cases, respectively. At an implantation depth <4 mm compared to >4 mm, all ostia were located below the HP with no difference in post-procedural mean gradients (14.5 mmHg ± 4.7 vs. 12.6 mmHg ± 5.8; p = .5, 95%CI 3.8-7.5). CONCLUSIONS: CA following ACURATE neo implantation for ViV-TAVR could potentially be challenging in a significant proportion of patients and specific consideration should be given to the implantation depth.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Tomografia , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
Catheter Cardiovasc Interv ; 97(3): 411-420, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32198845

RESUMO

OBJECTIVES: We aimed to evaluate the use of bare metal stent (BMS) implantation in current percutaneous coronary intervention (PCI) era, focusing on indications for use and clinical outcomes. BACKGROUND: Limited data on BMS usage in current clinical practice are available. METHODS: All patients who underwent PCI with at least one BMS implantation in 18 Italian centers from January 1, 2013 to December 31, 2017, were included in our registry. Rates of BMS use and reasons for BMS implantations were reported for the overall study period and for each year. Primary outcomes were mortality, bleeding (Bleeding Academic Research Consortium-BARC and Thrombolysis in Myocardial Infarction-TIMI non-CABG definitions), and major adverse cardiac events (MACE) defined as the composite of all-cause and cardiac death, any myocardial infarction, target vessel revascularization, or any stent thrombosis. RESULTS: Among 58,879 patients undergoing PCI in the study period, 2,117 (3.6%) patients (mean age 73 years, 69.7% males, 73.3% acute coronary syndrome) were treated with BMS implantation (2,353 treated lesions). The rate of BMS implantation progressively decreased from 10.1% (2013) to 0.3% (2017). Main reasons for BMS implantation were: ST-elevation myocardial infarction (STEMI) (23.1%), advanced age (24.4%), and physician's perception of high-bleeding risk (34.0%). At a mean follow-up of 2.2 ± 1.5 years, all-cause and cardiac mortality were 25.6 and 12.7%, respectively; MACE rate was 35.3%, any bleeding rate was 13.0% (BARC 3-5 bleeding 6.3%, TIMI non-CABG major bleeding 6.1%). CONCLUSION: In a large, contemporary, real-world, multicenter registry, BMS use progressively reduced over the last 5 years. Main reasons for BMS implantation were STEMI, advanced age, and physician's perception of high-bleeding risk. High rates of mortality and MACE were observed in this real-world high-risk population.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Feminino , Humanos , Itália , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Stents , Resultado do Tratamento
20.
Curr Cardiol Rep ; 23(10): 137, 2021 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-34410511

RESUMO

PURPOSE OF THE REVIEW: Annular-based strategies for treating tricuspid valve (TV) regurgitation do not always have satisfactory long-term outcomes. Management of failed TV annuloplasty can be challenging and requires a dedicated heart team approach. This review explores the treatment options available for failed TV annuloplasty. RECENT FINDINGS: Recent developments and novel percutaneous treatment options have emerged as promising alternatives for patients with failed TV annuloplasty. Leaflet-based interventions, valve-in-valve procedures, transcatheter tricuspid valves and new-generation trans-caval valves are all feasible options, which can assure good results whilst minimizing risks for the patient. Failure of tricuspid annuloplasty is not uncommon amongst patients treated with either a tricuspid ring or suture-based device. The complex anatomy, physiology and clinical risk profile should be carefully evaluated on an individual patient-by-patient basis in order to select the most appropriate clinical and percutaneous treatment strategy. Different transcatheter tricuspid valve repair or replacement techniques may provide an attractive alternative treatment option for managing this challenging patient cohort.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide , Valva Aórtica , Humanos , Valva Mitral/cirurgia , Recidiva , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA