Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Br J Surg ; 100(8): 1037-44, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23696463

RESUMO

BACKGROUND: Combining radioactive colloids and a near-infrared (NIR) fluorophore permits preoperative planning and intraoperative localization of deeply located sentinel lymph nodes (SLNs) with direct optical guidance by a single lymphatic tracer. The aim of this clinical trial was to evaluate and optimize a hybrid NIR fluorescence and radioactive tracer for SLN detection in patients with breast cancer. METHODS: Patients with breast cancer undergoing SLN biopsy were enrolled. The day before surgery, a periareolar injection of indocyanine green (ICG)-99mTc-radiolabelled nanocolloid was administered and a lymphoscintigram acquired. Blue dye was injected immediately before surgery. Intraoperative SLN localization was performed using a γ probe and the Mini-FLARE™ NIR fluorescence imaging system. Patients were divided into two dose groups, with one group receiving twice the particle density of ICG and nanocolloid, but the same dose of radioactive 99mTc. RESULTS: Thirty-two patients were enrolled in the trial. At least one SLN was identified before and during operation. All 48 axillary SLNs could be detected by γ tracing and NIR fluorescence imaging, but only 42 of them stained blue. NIR fluorescence imaging permitted detection of lymphatic vessels draining to the SLN up to 29 h after injection. Doubling the particle density did not yield a difference in fluorescence intensity (median 255 (range 98-542) versus 284 (90-921) arbitrary units; P = 0.590) or signal-to-background ratio (median 5·4 (range 3·0-15·4) versus 4·9 (3·5-16·3); P = 1·000) of the SLN. CONCLUSION: The hybrid NIR fluorescence and radioactive tracer permitted accurate preoperative and intraoperative detection of the SLNs in patients with breast cancer. REGISTRATION NUMBER: NTR3685 (Netherlands Trial Register; http://www.trialregister.nl).


Assuntos
Neoplasias da Mama/patologia , Mama/patologia , Carcinoma Ductal de Mama/patologia , Carcinoma Lobular/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Lobular/diagnóstico por imagem , Corantes , Feminino , Fluorescência , Humanos , Biópsia Guiada por Imagem , Verde de Indocianina , Cuidados Intraoperatórios/métodos , Metástase Linfática , Linfocintigrafia/métodos , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Biópsia de Linfonodo Sentinela/métodos , Espectroscopia de Luz Próxima ao Infravermelho , Agregado de Albumina Marcado com Tecnécio Tc 99m
2.
Artigo em Inglês | MEDLINE | ID: mdl-34425967

RESUMO

INTRODUCTION AND OBJECTIVES: To evaluate the migration of 99mTc-tilmanocept from the injection site (IS) as well as the uptake in sentinel nodes (SNs) and non-SNs for lymphatic mapping in patients with breast cancer and melanoma, scheduled for SN biopsy after interstitial tracer administration. MATERIALS AND METHODS: For 29 primary tumours in 28 patients (mean age: 62y, range: 45-81y) scheduled for SN biopsy planar images were acquired 10 and 120min after administration of 74MBq 99mTc-tilmanocept, in order to evaluate lymphatic drainage as well as uptake ratios between injection site (IS), SN and non-SN. SPECT-CT was performed immediately after delayed planar images to enable anatomical lymph node localization. RESULTS: SNs were visualized in all patients (100%) with drainage to 34 basins. Uptake in non-SNs was perceived in 16 basins (47%). Number of SNs was concordant between early and delayed images in all basins excepting five (86%). In 24 patients tracer migrated to one lymph node basin (LNB), in three to 2 and in one to 4. When IS was included (N=29) on image, IS/SN ratio could be measured per LNB. The IS/SN ratio at 2h compared to 15min decreased with an average of 66% (range: 15-96%). SN/non-SN 2h ratio in LNBs with visible non-SNs averaged 6.6 (range: 2.3-15.6). In 9 patients with two SNs SN1/SN2 ratio averaged 1.9 on delayed images. At histopathology, SNs were found to be tumour positive in 7 basins (20%). CONCLUSION: 99mTc-tilmanocept appears to meet the requirements for improved SN imaging in breast cancer and melanoma on the basis of early and persistent SN visualization frequently accompanied by no or markedly less non-SN uptake. This is associated to rapid migration from the injection site together with increasing SN uptake and retention as expressed by decreasing IS/SN and persistently high SN/non-SN ratios. Further head-to-head comparison of 99mTc-tilmanocept with standard SN radiotracers in larger series of patients is necessary.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Dextranos/farmacocinética , Mananas/farmacocinética , Melanoma/diagnóstico por imagem , Compostos Radiofarmacêuticos/farmacocinética , Linfonodo Sentinela/diagnóstico por imagem , Neoplasias Cutâneas/diagnóstico por imagem , Pentetato de Tecnécio Tc 99m/análogos & derivados , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Dextranos/administração & dosagem , Feminino , Humanos , Linfonodos/diagnóstico por imagem , Masculino , Mananas/administração & dosagem , Melanoma/patologia , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/administração & dosagem , Linfonodo Sentinela/metabolismo , Biópsia de Linfonodo Sentinela , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Neoplasias Cutâneas/patologia , Pentetato de Tecnécio Tc 99m/administração & dosagem , Pentetato de Tecnécio Tc 99m/farmacocinética , Fatores de Tempo
3.
Biomater Sci ; 9(5): 1683-1690, 2021 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-33410436

RESUMO

AIM: Pre-targeting is a proven strategy for in vivo delivery of a diagnostic or therapeutic payload. The pre-targeting concept can be realized through various conjugation strategies, one of which is based on copper-free "click" chemistry. Copper-free click reactions have shown in vivo potential for imaging and radionuclide therapy, but this conjugation strategy has not yet been explored in combination with microspheres or unicellular organisms. This study aims to evaluate the in vivo efficacy of strain-promoted azide-alkyne cycloaddition (SPAAC) reactions to achieve imaging and targeting of azide-functionalized macro-aggregated albumin (MAA) microspheres and Staphylococcus aureus bacteria. METHODS: MAA microspheres (diameter 10-90 µm) were functionalized with a biorthogonal Cy5 fluorophore, bearing an azide functionality (N3), to generate MAA-Cy5-N3. S. aureus (diameter ∼1 µm) were functionalized with 99mTc-UBI29-41-Cy5-N3, generating S. aureus-99mTc-UBI29-41-Cy5-N3. In situ and in vitro click conjugation on the -N3 moieties was studied for 20 h using a radioactivity-based assay and fluorescence microscopy. For in vivo validation, both primary entities, radiolabeled with 99mTc, were deposited into the microvasculature of the liver via intrasplenic injections. Secondary targeting was realized following the intravenous administration of indium-111-radiolabeled diethylenetriaminepentaacetic acid-dibenzocyclooctyne (111In-DTPA-DBCO). To assess click reaction efficiency in vivo, 99mTc and 111In-biodistributions were measured (SPECT and %ID g-1). Use of 111In-DTPA-DBCO in mice without MAA deposits or mice infected with non-functionalized S. aureus served as controls. Ex vivo confocal fluorescence imaging was carried out in excised tissues to confirm the presence of functionalized MAA and bacteria. RESULTS: In vitro data confirmed effective click reactions on both the MAA particles and the bacterial membrane. SPECT imaging and biodistribution studies revealed significantly (p < 0.05) increased accumulation of 111In-DTPA-DBCO at the sites where MAA-Cy5-N3 (7.5 ± 1.5%ID g-1vs. 3.5 ± 0.5%ID g-1 in control mice) and S. aureus-99mTc-UBI29-41-Cy5-N3 (9.3 ± 1.3%ID g-1vs. 6.0 ± 0.5%ID g-1 in control mice) resided. Ex vivo fluorescence imaging confirmed the presence of either functionalized MAA or S. aureus in excised spleens and livers of mice. CONCLUSION: Copper-free click chemistry between a DBCO moiety and Cy5-N3-functionalized microspheres or bacterial entities in the liver can be used to realize in vivo imaging and targeting.


Assuntos
Química Click , Medicina Nuclear , Animais , Camundongos , Microesferas , Staphylococcus aureus , Distribuição Tecidual
4.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31133492

RESUMO

PURPOSE: To assess the feasibility of using freehand Single Photon Emission Computed Tomography (freehandSPECT) for the identification of technetium-99m-hydroxydiphosphonate (99mTc-HDP) positive bone lesions and to evaluate the possibility of using these imaging data-sets for augmented- and virtual-reality based navigation approaches. MATERIAL AND METHODS: In 20 consecutive patients referred for scintigraphy with 99mTc-HDP, 21 three-dimensional freehandSPECT-images were generated using a handheld gamma camera. Concordance of the two different data sets was ranked. Furthermore, feasibility of segmenting the hotspot of tracer accumulation for navigation purposes was assessed. RESULTS: In 86% of the cases freehandSPECT images showed good concordance with the corresponding part of the scintigraphic images. In lesions with a signal to background ratio (SBR) >1.36, freehandSPECT provided an automatically segmented reference point for navigation purposes. In 14% of the cases (average SBR 1.82, range 1.0-3.4) freehandSPECT images showed intermediate concordance due to difficult anatomical area or negative bone scintigraphy and could not be used as navigation targets. CONCLUSION: In this pilot study, in 86% of the cases freehandSPECT demonstrated good concordance with traditional scintigraphy. A lesion with a SBR of 1.36 or more was suitable for navigation. These high-quality freehandSPECT images supported the future exploration navigation strategies, e.g. guided needle biopsies.


Assuntos
Biópsia por Agulha/métodos , Doenças Ósseas/diagnóstico por imagem , Câmaras gama , Biópsia Guiada por Imagem/métodos , Medronato de Tecnécio Tc 99m/análogos & derivados , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Doenças Ósseas/patologia , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Método Duplo-Cego , Desenho de Equipamento , Humanos , Biópsia Guiada por Imagem/instrumentação , Especificidade de Órgãos , Imagens de Fantasmas , Projetos Piloto , Compostos Radiofarmacêuticos/farmacocinética , Software , Medronato de Tecnécio Tc 99m/farmacocinética , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Imagem Corporal Total
5.
Rev Esp Med Nucl Imagen Mol ; 35(5): 292-7, 2016.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-27174865

RESUMO

PURPOSE: To assess if combined fluorescence- and radio-guided occult lesion localization (hybrid ROLL) is feasible in patients scheduled for surgical resection of non-palpable (18)F-FDG-avid lesions on PET/CT. METHODS: Four patients with (18)F-FDG-avid lesions on follow-up PET/CT that were not palpable during physical examination but were suspected to harbor metastasis were enrolled. Guided by ultrasound, the hybrid tracer indocyanine green (ICG)-(99m)Tc-nanocolloid was injected centrally in the target lesion. SPECT/CT imaging was used to confirm tracer deposition. Intraoperatively, lesions were localized using a hand-held gamma ray detection probe, a portable gamma camera, and a fluorescence camera. After excision, the gamma camera was used to check the wound bed for residual activity. RESULTS: A total of six (18)F-FDG-avid lymph nodes were identified and scheduled for hybrid ROLL. Comparison of the PET/CT images with the acquired SPECT/CT after hybrid tracer injection confirmed accurate tracer deposition. No side effects were observed. Combined radio- and fluorescence-guidance enabled localization and excision of the target lesion in all patients. Five of the six excised lesions proved tumor-positive at histopathology. CONCLUSION: The hybrid ROLL approach appears to be feasible and can facilitate the intraoperative localization and excision of non-palpable lesions suspected to harbor tumor metastases. In addition to the initial radioguided detection, the fluorescence component of the hybrid tracer enables high-resolution intraoperative visualization of the target lesion. The procedure needs further evaluation in a larger cohort and wider range of malignancies to substantiate these preliminary findings.


Assuntos
Fluordesoxiglucose F18 , Doença de Hodgkin/diagnóstico por imagem , Verde de Indocianina , Melanoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Agregado de Albumina Marcado com Tecnécio Tc 99m , Adulto , Idoso , Feminino , Doença de Hodgkin/patologia , Humanos , Melanoma/secundário , Imagem Multimodal
7.
Q J Nucl Med Mol Imaging ; 58(2): 127-39, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24835289

RESUMO

A few years ago SPECT/CT was successfully incorporated into the sentinel node (SN) procedure for breast cancer and melanoma. Important contributions of SPECT/CT in these two malignancies were the anatomical localization of SNs already visualized on planar images, the detection of additional SNs in aberrant basins, and the depiction of SNs in cases with no visualization on planar images. Recently, in a large series of melanoma patients the use of SPECT/CT was associated with the detection of more metastatic SNs and a higher rate of disease-free survival. Following the experiences in breast cancer and melanoma, SPECT/CT has been applied in oral cavity cancer as well as in urological and gynaecological malignancies. In the areas of lymphatic drainage of these malignancies (head and neck, pelvis, and upper abdomen) SPECT/CT appears to be essential to localize SNs, providing surgeons with helpful anatomical landmarks to plan SN biopsies. In gastrointestinal and lung malignancies SPECT/CT has only incidentally been used. With the improvement of the CT component in the second generation of SPECT/CT gamma cameras, nuclear physicians today can identify lymph nodes corresponding with the radioactive SNs. This is possible using a display of SPECT/CT similar to that of conventional tomography. Multiplanar reconstruction enables to correlate radioactive sentinel nodes seen on fused SPECT/CT with lymph nodes seen on CT, and the use of cross-reference lines allows the navigation between axial, coronal and sagittal views. This visual information is helpful for the intraoperative procedure and for post-excision assessment using portable devices. Fused SPECT/CT images may also be three-dimensionally displayed, improving anatomical SN localisation and recognition. This recent imaging improvement is leading to a new paradigm of "see and open" in contraposition to the former "open and see" in the SN procedure. The new mixed reality protocols which are able to transfer SPECT/CT to the operating room for surgical navigation will reinforce this "see and open" concept. However, a comprehensive interpretation of SPECT/CT together with lymphoscintigraphy is necessary to identify radioactive lymph nodes as sentinel nodes and classify them into different categories that are important for the intraoperative procedure.


Assuntos
Neoplasias da Mama/diagnóstico , Linfonodos/patologia , Melanoma/diagnóstico , Melanoma/secundário , Biópsia de Linfonodo Sentinela/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Medicina Baseada em Evidências , Feminino , Humanos , Biópsia Guiada por Imagem/métodos , Metástase Linfática , Masculino , Imagem Multimodal/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA