Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Eur Radiol ; 19(2): 370-9, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18795299

RESUMO

Fluoro-18-deoxyglucose positron emission tomography computed tomography (FDG-PET/CT) and magnetic resonance imaging (MRI), including unenhanced single-shot spin-echo echo planar imaging (SS SE-EPI) and small paramagnetic iron oxide (SPIO) enhancement, were compared prospectively for detecting colorectal liver metastases. Twenty-four consecutive patients suspected for metastases underwent MRI and FDG-PET/CT. Fourteen patients (58%) had previously received chemotherapy, including seven patients whose chemotherapy was still continuing to within 1 month of the PET/CT study. The mean interval between PET/CT and MRI was 10.2+/-5.2 days. Histopathology (n=18) or follow-up imaging (n=6) were used as reference. Seventy-seven metastases were detected. In nine patients, MRI and PET/CT gave concordant results. Sensitivities for unenhanced SS SE-EPI, MRI without SS SE-EPI and FDG-PET/CT were, respectively, 100% (p=9 x 10(-10) vs PET, p=8 x 10(-3) vs MRI without SS SE-EPI), 90% (p=2 x 10(-7) vs PET) and 60%. PET/CT sensitivity dropped significantly with decreasing size, from 100% in lesions larger than 20 mm (identical to MRI), over 54% in lesions between 10 and 20 mm (p=3 x 10(5) versus unenhanced SS SE-EPI), to 32% in lesions under 10 mm (p=6 x 10(-5) versus unenhanced SS SE-EPI). Positive predictive value of PET was 100% (identical to MRI). MRI, particularly unenhanced SS SE-EPI, has good sensitivity and positive predictive value for detecting liver metastases from colorectal carcinoma. Its sensitivity is better than that of FDG-PET/CT, especially for small lesions.


Assuntos
Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste/farmacologia , Dextranos , Feminino , Compostos Férricos/farmacologia , Óxido Ferroso-Férrico , Fluordesoxiglucose F18/farmacologia , Humanos , Ferro/farmacologia , Fígado/patologia , Nanopartículas de Magnetita , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Óxidos/farmacologia
2.
Eur J Radiol ; 81(12): 3870-6, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22944331

RESUMO

PURPOSE: To evaluate dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) for prediction and early monitoring of treatment in colorectal liver metastases. MATERIALS AND METHODS: Ten patients were included. Baseline and follow-up DCE-MRI examinations were evaluated by whole tumour and selected ROI placements calculating Kep-values. Selective ROIs, concentric-like and hot spot, were drawn on early arterial phase images. Monitoring of treatment was performed comparing RECIST1.1 criteria with whole tumour and selected ROI placement. To evaluate treatment effect between responders and non-responders, independent samples t-test was used on Kep-values. RESULTS: In each patient largest lesion was evaluated totalling 10 target lesions. At baseline, for whole tumour ROI placements mean Kep-values in responders were significantly higher than mean Kep-values in non-responders (t=7.481, p<0.001). Selective ROI placement comparison of mean Kep-values at baseline and after 6 weeks of treatment (first follow-up measurement) showed significant decrease in responding patients (t=4.706, p=0.003) whereas increase in Kep-values in non-responding patients was not statistically significant. CONCLUSION: This preliminary study shows that baseline Kep for whole tumour ROI is a predictor for treatment outcome. Decrease of Kep using selective ROIs allows early identification of response after 6 weeks of treatment.


Assuntos
Carcinoma/secundário , Carcinoma/terapia , Neoplasias Colorretais/patologia , Neoplasias Colorretais/terapia , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Carcinoma/patologia , Meios de Contraste , Feminino , Humanos , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
3.
Eur J Radiol ; 74(3): 529-35, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19375256

RESUMO

PURPOSE: To prospectively evaluate a new imaging sequence (4D THRIVE) for whole liver perfusion in high temporal and spatial resolution. Feasibility of parametric mapping and its potential for characterizing focal liver lesions (FLLs) are investigated. MATERIALS AND METHODS: Fifteen patients suspected for colorectal liver metastases (LMs) were included. Parametric maps were evaluated qualitatively (ring-enhancement and lesion heterogeneity) and compared to three-phased contrast-enhanced MRI. Quantitative analysis was based on average perfusion values of entire FLLs. Reference standard comprised surgery with histopathology or follow-up imaging. Fisher's exact test was used for qualitative and Kruskal-Wallis test for quantitative analysis. RESULTS: In total 29 LMs, 17 hemangiomas and 4 focal nodular hyperplasias were evaluated. FLLs could be differentiated by qualitative assessment of parametric maps respectively three-phased contrast-enhanced MRI (Fisher's p<0.001 for comparisons between LMs and hemangiomas and LMs and FNHs for both ring-enhancement and lesion heterogeneity) rather than by quantitative analysis of parametric maps (Chi-square for Kep=0.33 (p=0.847) and Chi-square for Kel=1.35 (p=0.509)). CONCLUSION: This preliminary study shows potential of 4D THRIVE for whole liver imaging enabling calculation of parametric maps. Qualitative rather than quantitative analysis was accurate for differentiating malignant and benign FLLs.


Assuntos
Algoritmos , Neoplasias Colorretais/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/secundário , Angiografia por Ressonância Magnética/métodos , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Eur J Radiol ; 69(1): 131-8, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17950553

RESUMO

PURPOSE: To assess the added value of true diffusion (D), perfusion factor (f) and apparent diffusion coefficient at low b-values (ADC(low)) for differentiation between liver metastases and hemangiomas based on respiratory-triggered high-resolution Black-Blood Single-Shot SpinEcho Echo Planar Imaging (BB SS SE-EPI). MATERIALS AND METHODS: Twenty-five patients suspected for malignant colorectal liver lesions were included in this study. A total of 106 lesions were examined. Different b-value images were compared for lesion conspicuity, image quality and artifacts using rank order statistic (RIDIT) and Student's t-test. D, f, and ADC(low) values were calculated. Pearson correlation coefficient is used for comparison of interobserver variability. RESULTS: Best lesion conspicuity (p<0.05) was achieved with BB SS SE-EPI (b=0 and 10s/mm(2)); best image quality (p<0.05) with b=10s/mm(2). Image artifacts were lowest (p<0.05) with b=0s/mm(2). Over the whole sample, D in metastases (D(met)) was significantly (p<0.05) lower than D in hemangiomas (D(hem)); f and ADC(low) of metastases (f(met), respectively, ADC(lowmet)) were significantly (p<0.05) higher than f and ADC(low) of hemangiomas (f(hem), respectively, ADC(lowhem)). All Pearson correlations were statistically significant at a 0.01 level. CONCLUSIONS: This preliminary study shows the potential of BB SS SE-EPI as a useful technique to aid in differentiating between liver metastasis and hemangioma. The calculation of D, f and ADC(low) provides useful additional information for differentiating metastases from hemangiomas.


Assuntos
Neoplasias Colorretais/patologia , Imagem Ecoplanar/métodos , Hemangioma/patologia , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/secundário , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Necrose/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Eur J Radiol ; 72(3): 432-9, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18849130

RESUMO

PURPOSE: To compare lesion conspicuity and image quality between single-shot spin echo echo planar imaging (SS SE-EPI) before, immediately and 5min after intravenous (IV) injection of superparamagnetic iron oxide (SPIO) for detecting and characterizing focal liver lesions (FLLs). MATERIALS AND METHODS: Twenty-five patients suspected for colorectal liver metastases were prospectively included. Lesion detection and characterization were compared between all SS SE-EPI and T2-weighted turbo spin echo (T2w TSE) sets (two-sided Fisher's exact test). Image quality and lesion conspicuity were compared for SS SE-EPI sets using rank order statistic (RIDIT). Reference standard comprised of surgery, biopsy and/or follow-up. RESULTS: Reference standard demonstrated 18 benign and 43 malignant FLLs. Best lesion detection (p<0.05) was achieved with non-contrast-enhanced SS SE-EPI. Lesion characterization was best using all T2w TSE sequences. Best image quality and lesion conspicuity (p<0.05) was achieved with non-contrast-enhanced SS SE-EPI. CONCLUSION: Non-contrast-enhanced SS SE-EPI was best for lesion detection. SS SE-EPI sequences were not useful for lesion characterization (differentiation between benign and malignant lesions). Unenhanced SS SE-EPI did not allow differentiation especially as many benign FLLs were hyperintense on the highest b-value images. Combining unenhanced and SPIO-enhanced SS SE-EPI performed better but still was not clinically useful due to variable degree of uptake and vascular pooling of SPIO for (especially) benign FLLs. T2w TSE with SPIO-enhancement was needed for characterization.


Assuntos
Neoplasias Colorretais/diagnóstico , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Óxido Ferroso-Férrico , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/secundário , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
J Magn Reson Imaging ; 27(1): 117-24, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18050350

RESUMO

PURPOSE: To prospectively compare single-shot spin-echo echo-planar imaging (SSSE-EPI) using b = 0, 10, 150, and 400 seconds/mm(2) with standard MRI techniques after intravenous super paramagnetic iron oxide (SPIO) in the detection and characterization of focal liver lesions with focus on small (<10 mm) focal liver lesions. MATERIALS AND METHODS: A total of 25 patients suspected for colorectal liver metastases were included. Number of detected lesions was evaluated. Image quality was compared between SSSE-EPI sequence and post-SPIO (fat-suppressed T1-weighted [T1w] gradient echo [GE], T2-weighted [T2w] turbo spin echo [TSE] and T2* GE) sequences using rank order statistic (RIDIT). Lesion characterization was performed for SSSE-EPI and for all remaining sequences pre- and post-SPIO. Reference standard comprised surgery, biopsy, and/or follow-up. RESULTS: Reference standard demonstrated 25 hemangiomas and 70 metastases. Best lesion detection respectively best image quality (P < 0.05) was achieved with SSSE-EPI (b = 10 seconds/mm(2)) post-SPIO T1w GE and T2w turbo spin echo. Lesion characterization using all sequences pre- and post-SPIO performed best for lesion characterization compared with SSSE-EPI. CONCLUSION: This preliminary study shows the potential of SSSE-EPI as a stand-alone sequence for the detection of liver hemangiomas and metastases when compared with SPIO-enhanced imaging. Sequences pre- and post-SPIO are needed for qualitative lesion characterization.


Assuntos
Neoplasias Colorretais/patologia , Meios de Contraste/administração & dosagem , Imagem Ecoplanar/métodos , Ferro/administração & dosagem , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética/métodos , Óxidos/administração & dosagem , Dextranos , Feminino , Óxido Ferroso-Férrico , Humanos , Injeções Intravenosas , Nanopartículas de Magnetita , Masculino , Pessoa de Meia-Idade , Imagem Corporal Total
7.
J Comput Assist Tomogr ; 27(2): 284-8, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12703027

RESUMO

OBJECTIVE: The aim of this study is to compare multislice computed tomography (MSCT) in combination with a newly developed semiautomated software program with calibrated aortography in patients who are scheduled for endovascular aortic stent graft placement. METHODS: From November 2000 until December 2001, seven patients with an abdominal aortic aneurysm (AAA) underwent both calibrated aortography and MSCT for preoperative endovascular stent graft planning. Both studies were performed within 14 days. Further, length measurements were performed with a semiautomated computerized tomographic angiography (CTA) calibration method and a conventional calibrated aortography technique using three differently configured tubes with variable tortuosity. The AAA length measurements of the semiautomated CTA calibration method and the calibrated aortography were compared. RESULTS: Statistical analysis included linear regression analysis and revealed a probability value of 0.000381 and an r2 value of 0.93. Using phantoms, it is proven by the authors that the accuracy of the semiautomated CTA calibration method increases with increasing tortuosity when compared with the conventional calibrated aortography technique. CONCLUSIONS: Our preliminary results show that the semiautomated CTA calibration method has a potentially advantageous role in preoperative stent graft planning regarding the aortic length measurements and seems to be more accurate than calibrated aortography, especially in extremely tortuous vessels. Further studies have to be performed, however.


Assuntos
Aorta Abdominal/transplante , Artéria Ilíaca/transplante , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/cirurgia , Aortografia , Implante de Prótese Vascular , Calibragem , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Desenho de Prótese , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA