Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Echocardiography ; 39(6): 783-793, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35536700

RESUMO

OBJECTIVES: To determine the 4D Flow Cardiac Magnetic Resonance (CMR) thresholds that achieve the best agreement with transthoracic echocardiography (TTE) for grading mitral regurgitation (MR). METHODS: We conducted a single-center prospective study of patients evaluated for chronic primary MR in 2016-2020. MR was evaluated blindly by TTE and 4D Flow CMR, respectively by two cardiologists and two radiologists with decades of experience. MR was graded with both methods as mild, moderate, or severe. 4D Flow CMR measurements included MR regurgitant volume per beat (RV) and mitral anterograde flow per beat (MF). RF was obtained as the ratio RV/MF. Additionally, MF was compared to left ventricular stroke volume (LVSV) by cine-CMR. RESULTS: We included 33 patients in the initial cohort and 33 in the validation cohort. Inter-observer agreement was excellent for 4D Flow CMR ICC = .94 (95% CI, .86-.97, p < 0.0001). Using recommended TTE thresholds (30 ml, 60 ml, 30%, 50%), agreement was moderate for RV and RF. The best agreement between 4D Flow CMR and TTE was obtained with CMR thresholds of 20 and 40 ml for RV (κ = .93; 95% CI, .8-1) and 20% and 37% for RF (κ = .90; 95% CI, .7-.9). In the validation cohort, agreement between TTE and 4D Flow CMR was good with the optimal thresholds (κ = .78; 95% CI, .61-.94). CONCLUSION: We propose CMR thresholds that provide a good agreement between TTE and CMR for grading MR. Further studies are needed to fully validate 4D-Flow CMR accuracy for primary MR quantification.


Assuntos
Insuficiência da Valva Mitral , Ecocardiografia/métodos , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Insuficiência da Valva Mitral/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
2.
Radiology ; 274(3): 684-92, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25599157

RESUMO

PURPOSE: To assess the feasibility of exercise perfusion computed tomography (CT) in patients suspected of having hemodynamically significant coronary stenosis. MATERIALS AND METHODS: This study had institutional review board approval, and all patients gave informed consent. Thirty-two consecutive patients (26 men [mean age, 63 years] and six women [mean age, 71 years]) with 55 coronary stenoses of at least 50% underwent coronary CT angiography (one stenosis in 13 patients, two stenoses in 15 patients, and three stenoses in four patients). CT myocardial perfusion imaging was performed within 1 minute after patients performed supine exercise on an ergometer secured to the CT table. The pressure-rate product was computed to assess level of exercise. The myocardial enhancement ratio between stenotic and normally perfused territories was determined for each stenosis. Fractional flow reserve less than 0.8, as measured during invasive coronary angiography, was the reference for defining significant stenoses. Receiver operating characteristic curves were constructed to determine the myocardial enhancement ratio cutoff value. RESULTS: In the per-patient analysis, a myocardial enhancement ratio cutoff of 0.8 performed best for identifying functionally significant stenosis: Sensitivity was 95% (21 of 22 patients), specificity was 90% (nine of 10 patients), positive predictive value was 95% (21 of 22 patients), negative predictive value was 90% (nine of 10 patients), and accuracy was 94% (30 of 32 patients). Corresponding values in the per-stenosis analysis were 97% (29 of 30 stenoses), 96% (23 of 24 stenoses), 97% (29 of 30 stenoses), 96% (23 of 24 stenoses), and 96% (52 of 54 stenoses), respectively. CONCLUSION: Exercise CT myocardial perfusion imaging is feasible and accurate for assessment of the functional significance of coronary stenosis.


Assuntos
Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Teste de Esforço/métodos , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
3.
Histopathology ; 65(2): 278-82, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24702653

RESUMO

AIMS: Angiomatoid fibrous histiocytoma (AFH) is a rare neoplastic disease usually occurring in the dermis or subcutis of the extremities of young adults or children. Although sporadic cases in deep soft tissue and visceral organs have been reported, we present here the first description of AFH developing in a large artery. METHODS AND RESULTS: Paraffin sections of the surgical specimen were stained with haematoxylin and eosin, and immunohistochemistry was performed (CKAE1/AE3, EMA, CD34, p63, CD38, smooth muscle actin, and desmin). In addition, FISH and RT-PCR were applied in order to check for EWRS rearrangement. The histomorphological features, and FISH analysis revealing rearrangement of EWSR, indicated the definitive diagnosis of AFH. RT-PCR confirmed EWSR rearrangement, and detected an EWSR1-ATF1 fusion transcript. CONCLUSIONS: A thoracic location of AFH has not been reported until very recently, and shares a differential diagnosis with diverse neoplasms, including spindle cell carcinoma and low-grade sarcoma. We describe the first reported case of thoracic AFH arising in a large vessel, and highlight distinctive histological and molecular features.


Assuntos
Histiocitoma Fibroso Maligno/patologia , Artéria Pulmonar/patologia , Idoso , Biomarcadores Tumorais/análise , Feminino , Histiocitoma Fibroso Maligno/genética , Humanos , Imuno-Histoquímica , Hibridização in Situ Fluorescente , Proteínas de Fusão Oncogênica/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa
5.
Diagn Interv Imaging ; 103(6): 316-323, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35090845

RESUMO

PURPOSE: The purpose of this study was to evaluate a deep-learning model (DLM) for classifying coronary arteries on coronary computed tomography -angiography (CCTA) using the Coronary Artery Disease-Reporting and Data System (CAD-RADS). MATERIALS AND METHODS: The DLM was trained with 10,800 curved multiplanar reformatted (cMPR) CCTA images classified by an expert radiologist using the CAD-RADS. For each of the three main coronary arteries, nine cMPR images 40° apart acquired around each arterial circumference were then classified by the DLM using the highest probability. For the validation set composed of 159 arteries from 53 consecutive patients, the images were read by two senior and two junior readers; consensus of the two seniors was the reference standard. With the DLM, the majority vote for the nine images was used to classify each artery. Three groups (CAD-RADS 0, 1-2, or 3-4-5) and 2 groups CAD-RADS 0-1-2 or 3-4-5 (<50% vs. ≥50% stenosis) were used for comparisons with readers and consensus. Performance of the model and readers was compared to the consensus reading using the intraclass coefficient (ICC) and Cohen's kappa coefficient at the artery and patient levels. RESULTS: With the three groups at the artery level, the ICC of the DLM was 0.82 (95% CI: 0.75-0.88) and not significantly different from those of 3/4 readers; accuracy was 81%. With the binary classification, Cohen kappa coefficient of the DLM was 0.85 (95% CI: 0.69-0.94) and not significantly different from that of 3/4 readers; accuracy was 96%. At the patient level, sensitivity and specificity were 93% and 97% respectively, and the negative predictive value was 97%. CONCLUSION: The DLM detected ≥50% stenoses with performances similar to those achieved by senior radiologists.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Aprendizado Profundo , Angiografia por Tomografia Computadorizada/métodos , Constrição Patológica , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes
6.
Artif Organs ; 35(11): 1115-8, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21995580

RESUMO

Neurological morbidity is a major concern in pediatric cardiac surgery. Cardiopulmonary bypass is one of the few modifiable factors affecting neurodevelopmental outcome. This study aimed to measure the incidence of abnormalities apparent by magnetic resonance imaging (MRI) after neonatal arterial switch operation using warm surgery. Neonates admitted for transposition of the great arteries underwent pre- and postoperative brain MRI. They were operated on using a warm perfusion method. The data collected included antenatal diagnosis, place of birth, gestational age, total maturation score as described by Childs, weight, cyanosis as assessed by minimal SpO(2) sustained for at least 10 min, balloon atrial septostomy, prostaglandin E1 infusion, need for neonatal intensive care, bypass time, time to extubation, and length of stay in intensive care. All of the MRI results were interpreted by the same senior specialist in pediatric neuroimaging, and lesions were classified as white matter injury, infarct, or hemorrhage. On preoperative exam, nine patients (42%) had one or more lesions, with infarct in four patients, white matter injury in four patients, and hemorrhage in five. We were unable to find any correlation between the data collected and brain injury. On postoperative exam, there was one new infarct, two new cases of white matter injury, and three cases of hemorrhage but no worsening of the preoperative lesions. Based on this initial experience with brain imaging, there is no deleterious effect of warm perfusion and no rationale to postpone surgery in neonates with "subclinical" brain injury.


Assuntos
Procedimentos Cirúrgicos Cardiovasculares/métodos , Imageamento por Ressonância Magnética , Neuroimagem , Perfusão/métodos , Transposição dos Grandes Vasos/cirurgia , Encéfalo/patologia , Ponte Cardiopulmonar/métodos , Humanos , Recém-Nascido , Período Pós-Operatório , Período Pré-Operatório , Temperatura
7.
Pediatr Radiol ; 41(2): 244-9, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20821005

RESUMO

BACKGROUND: For coronary artery visualization, retrospective ECG-gated acquisition by dual-source computed tomography (DSCT) was superior to spiral non-ECG-gated acquisition in a paediatric population of congenital heart disease (CHD) patients. However, retrospective cardiac CT is associated with substantial radiation doses to the patient. Recently, DSCT with end-systolic reconstruction was found to be robust for imaging the coronary arteries in patients with high heart rates. OBJECTIVE: To evaluate step-and-shoot DSCT with end-systolic reconstruction for evaluating the heart, coronary arteries and other thoracic structures in young children with CHD. MATERIALS AND METHODS: All neonates and children younger than 6 years of age who were referred to our institution for CHD evaluation between September and October 2009 were included in the study. ECG-gated DSCT was performed in sequential prospective mode centred on the systolic phase identified by ECG analysis. To assess the radiation dose, we recorded the dose-length product (DLP) in mGy·cm and the effective dose in mSv estimated from the DLP. Overall image quality was evaluated using a 5-grade scoring system and was assessed by looking at cardiac and vascular structures. The image quality for the proximal and middle segments of the right and left coronary arteries was also evaluated using a 5-grade scale. RESULTS: Images of diagnostic quality (grade ≥ 3) were obtained in all 30 children with a mean image quality grade of 4.7 ± 0.6 (range, 3-5). Mean DLP was 5.7 ± 4.8 mGy*cm (range, 1-22 mGy cm) and mean effective radiation dose was 0.26 ± 0.16 mSv (range, 0.05-0.8 mSv). CONCLUSION: Prospective ECG-gated thoracic DSCT at end-systole usually provides adequate thoracic and coronary artery image quality in neonates, infants and young children with CHD, independent of heart rate. This new method is associated with lower radiation doses compared to previous literature (mean effective dose, 0.26 mSv).


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Doses de Radiação , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Eur Radiol ; 20(5): 1118-23, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-19890642

RESUMO

OBJECTIVES: Reconstruction of cardiac computed tomography (CT) images is challenging when the heart rate is higher than 65 beats per minute (bpm). The optimal reconstruction time is often found to be at the end-systolic phase, but image quality remains uncertain. Using dual-source (DS) CT and 83-ms temporal resolution, we evaluated the robustness of the temporal window with low motion during the end systole. METHODS: We studied 41 DSCT in consecutive patients with a heart rate >65 bpm. Eleven systolic reconstructions were performed every 20 ms between 200 ms and 400 ms of the R-R interval. The end-systolic temporal window (ESTW) was defined as the interval between the first and last selected phases judged adequate for diagnosis. RESULTS: Heart rates varied from 67 to 150 bpm. ESTW was always to be found greater than 100 ms. The mean ESTW was 178 ms (SD: 57 ms), and varied independently of heart rate. All data sets achieved diagnostic quality during the end-systolic phase at a time point between 35 and 50% of the R-R interval. CONCLUSION: Our data suggest that CT with a temporal window below 100 ms may provide acceptable systolic reconstructions at any heart rate, in a large proportion of patients.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Frequência Cardíaca/fisiologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Iopamidol/análogos & derivados , Masculino , Intensificação de Imagem Radiográfica/métodos , Sístole
9.
Pediatr Radiol ; 40(6): 869-75, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20432005

RESUMO

Multidetector CT (MDCT) is increasingly used for imaging congenital heart disease (CHD) patients in addition to echocardiography, due to its ability to provide high quality three-dimensional images, giving a comprehensive evaluation of complex heart malformations. Using 4-slice or 16-slice CT, diagnostic information in CHD patients is limited to extra-cardiac anatomy, mainly the pulmonary arteries, aorta and venous connections. Due to high heart rates in babies however, coronary evaluation and intra-cardiac analysis were not reliable with the first generations of MDCT. Larger detector size with 64-slice CT and faster acquisition time, up to 75 ms for one slice, has progressively improved coronary and intra-cardiac visualization. Because radiation dose is the main concern, especially in children, every attempt to minimize dose whilst preserving image quality is important: the ALARA concept should always be applied in this population. The 80 kVp setting is now well accepted as a standard for more and more radiological teams involved in CT of children. Different acquisition strategies are now possible for childhood coronary imaging, using retrospective or even prospective gating. Using the latest technology, sub-mSv acquisitions are now attainable for scanning a whole thorax, providing a complete analysis of any 3-D cardiac malformation, including coronary artery course visualisation. This review will describe how technological developments have improved image quality with continuous reduction of radiation dose.


Assuntos
Conhecimentos, Atitudes e Prática em Saúde , Cardiopatias Congênitas/diagnóstico por imagem , Radiologia/tendências , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/tendências , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estados Unidos
10.
Pediatr Radiol ; 39(7): 668-76, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19319514

RESUMO

BACKGROUND: There are only a few reports on the diagnostic accuracy, and the technical and clinical feasibility, of multidetector CT (MDCT) in infants with congenital heart disease (CHD). OBJECTIVE: To evaluate the image quality and radiation dose of DSCT in babies with CHD. MATERIALS AND METHODS: From November 2006 to November 2007, 110 consecutive infants with CHD referred for pre- or postoperative CT evaluation were included. All these infants had a spiral angiothoracic DSCT scan after injection of 300 mg/ml iopromide at 0.5-1 ml/s with a power injector using a low-dose protocol (80 kVp and 10 mAs/kg). Of these infants, 34 also underwent an ECG-gated coronary CT scan for evaluation of the course of the coronary arteries. RESULTS: No serious adverse events were recorded. The mean dose-length product was 8+/-6 mGy x cm (effective dose 0.5+/-0.2 mSv) and 21+/-9 mGy x cm (effective dose 1.3+/-0.6 mSv) during the non-ECG-gated spiral acquisition and ECG-gated acquisition, respectively. Diagnostic quality images were achieved with the spiral acquisition in 89% of cases. Compared to the spiral mode, ECG-gated acquisition significantly improved the visualization of the coronary arteries, with a diagnostic rate of 91% and 84% for the left and right coronary arteries, respectively. CONCLUSION: DSCT together with iopromide at 300 mg/ml is a valuable tool for the routine clinical evaluation of infants with CHD. ECG-gated acquisition provides reliable visualization of the course of the coronary arteries.


Assuntos
Carga Corporal (Radioterapia) , Angiografia Coronária/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Doses de Radiação , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Presse Med ; 43(9): 994-1007, 2014 Sep.
Artigo em Francês | MEDLINE | ID: mdl-25154908

RESUMO

Chronic thromboembolic pulmonary hypertension is a rare but underdiagnosed disease. The development of imaging played a crucial role for the screening and the decision of operability over the past few years. Indeed, chronic thromboembolic pulmonary hypertension is the only type of pulmonary hypertension with a potential curative treatment: pulmonary endarterectomy. It is a complexe surgical procedure performed under cardiopulmonary bypass with deep hypothermia and circulatory arrest. The aim of the procedure is to completely remove the scar tissue inside the pulmonary arteries down to the segmental and sub-segmental levels. Compared to lung transplantation, which carries a postoperative mortality of 15-20% and a 5-year survival of 50%, pulmonary endarterectomy is a curative treatment with a postoperative mortality of less than 3%. However, lung transplantation remains an option for young patients with inoperable distal disease or after pulmonary endarterectomy failure. Considering that medical history of deep venous thrombosis or pulmonary embolism is lacking in 25 to 50%, the diagnosis of chronic thromboembolic pulmonary hypertension remains challenging. The lung V/Q scan is useful for the diagnosis showing ventilation and perfusion mismatches. Lesions located at the level of the pulmonary artery, the lobar or segmental arteries may be accessible to surgical removal. The pulmonary angiogram with the lateral view and the pulmonary CT scan help to determine the level of the intravascular lesions. If there is a correlation between the vascular obstruction assessed by imaging and the pulmonary resistance, pulmonary endarterectomy carries a postoperative mortality of less than 3% and has a high rate of success. If the surgery is performed at a later stage of the disease, pulmonary arteriolitis developed mainly in unobstructed territories and participated in the elevated vascular resistance. At this stage, postoperative risk is higher.


Assuntos
Endarterectomia/métodos , Hipertensão Pulmonar/cirurgia , Embolia Pulmonar/cirurgia , Arterite/diagnóstico , Cateterismo Cardíaco , Doença Crônica , Diagnóstico Diferencial , Equinococose/diagnóstico , Ecocardiografia Doppler , Humanos , Hipertensão Pulmonar/diagnóstico , Pulmão/diagnóstico por imagem , Transplante de Pulmão , Mediastinite/diagnóstico , Células Neoplásicas Circulantes , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico , Radiografia , Cintilografia , Sarcoma/diagnóstico , Neoplasias Vasculares/diagnóstico
13.
Int J Cardiovasc Imaging ; 29(3): 651-7, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22918571

RESUMO

To compare image quality of coronary CT angiography in step-and-shoot mode at the diastolic phase at low heart rates (<70 bpm) and systolic phase at high heart rates (≥70 bpm). We prospectively included 96 consecutive patients then excluded 5 patients with arrhythmia. Coronary CT-angiography was performed using a dual-source 128-slice CT machine, at the diastolic phase in the 55 patients with heart rates <70 bpm (group D) and at the systolic phase in the 36 patients with heart rates ≥70 (group S). Image quality was scored on a 5 point-scale (1, not interpretable; 2, insufficient for diagnosis; 3, fair, sufficient for diagnosis; 4, good; 5, excellent). In addition, we compared the number of stair-step artifacts in the two groups. Mean image quality score was 4 (0.78) in group D and 4.1 (0.34) in group S (NS), with an unequal distribution (p = 0.01). Step artifacts were seen in 44 % of group D and 18 % of group S patients (p = 0.02). In 3 group D patients and no group S patients, the image score was <3 due to artifacts, requiring repeat CT-angiography. When performing dual-source 128-slice CT-angiography, step-and-shoot acquisition provides comparable mean image quality in systole, with less variability and fewer stair-step artifacts, compared to diastole. This method may be feasible at any heart rate in most patients in sinus rhythm, allowing low-dose prospective acquisition without beta-blocker premedication.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Frequência Cardíaca , Tomografia Computadorizada Multidetectores , Doses de Radiação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Meios de Contraste , Doença da Artéria Coronariana/fisiopatologia , Diástole , Eletrocardiografia , Estudos de Viabilidade , Humanos , Iohexol/análogos & derivados , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Sístole , Adulto Jovem
15.
Ann Thorac Surg ; 95(3): e71-2, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23438569

RESUMO

Invasive thymoma is a malignant tumor of the anterior mediastinum that could have intravenous affinity associated with a high recurrence rate. This report highlights the need of coronary sinus exploration when intraatrial thymoma recurrence is diagnosed. Surgical resection of invaded coronary sinus can be achieved safely with a good result.


Assuntos
Neoplasias Cardíacas/secundário , Recidiva Local de Neoplasia/secundário , Timoma/secundário , Neoplasias do Timo/secundário , Biópsia , Procedimentos Cirúrgicos Cardíacos/métodos , Seio Coronário , Seguimentos , Átrios do Coração , Neoplasias Cardíacas/diagnóstico , Neoplasias Cardíacas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico , Recidiva Local de Neoplasia/cirurgia , Tomografia por Emissão de Pósitrons , Timectomia , Timoma/diagnóstico , Timoma/cirurgia , Neoplasias do Timo/diagnóstico , Neoplasias do Timo/cirurgia , Tomografia Computadorizada por Raios X
16.
J Thorac Cardiovasc Surg ; 142(1): 120-6, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21292283

RESUMO

OBJECTIVES: A detailed preoperative evaluation of coronary anatomy is mandatory before surgical intervention for tetralogy of Fallot. In pediatric patients, the preoperative evaluation of coronary anatomy has relied classically on conventional angiographic analysis and, more recently, on echocardiographic analysis, which have well-known limitations and complications. Recent technological improvements allow the use of multislice computed tomographic analysis to evaluate coronary artery anatomy in very young children, even those with high heart rates. The purpose of this prospective study was to assess the accuracy of preoperative dual-source computed tomographic analysis in detecting coronary artery abnormalities by using surgical findings as the reference standard. METHODS: We prospectively evaluated 100 patients with tetralogy of Fallot before surgical intervention between November 2006 and September 2009 by using dual-source computed tomographic analysis with either retrospective, electrocardiographically gated, helical computed tomographic analysis or prospective, electrocardiographically triggered, sequential computed tomographic acquisition. The patients had a median age of 6.8 months (range, 1.2 months-6.8 years) and a median weight of 7.9 kg (range, 3-30 kg). RESULTS: Compared with surgical findings, dual-source computed tomographic analysis had 100% sensitivity and 100% specificity for detecting coronary artery abnormalities. Major coronary artery abnormalities were found in 7 (7%) patients. The radiation dose was low. CONCLUSIONS: Dual-source computed tomographic analysis is an accurate and noninvasive tool for delineating coronary artery anatomy before surgical intervention in children with tetralogy of Fallot. Dual-source computed tomographic analysis might deserve to be used routinely instead of angiographic analysis and in combination with echocardiographic analysis for the preoperative assessment of patients with tetralogy of Fallot.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Angiografia Coronária/métodos , Anomalias dos Vasos Coronários/diagnóstico por imagem , Tetralogia de Fallot/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Procedimentos Cirúrgicos Cardíacos , Criança , Pré-Escolar , Anomalias dos Vasos Coronários/cirurgia , Feminino , França , Humanos , Lactente , Masculino , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Estudos Prospectivos , Doses de Radiação , Sensibilidade e Especificidade , Tetralogia de Fallot/cirurgia , Tomografia Computadorizada Espiral , Ultrassonografia
17.
Transplantation ; 91(5): 583-8, 2011 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-21297555

RESUMO

BACKGROUNDS: We evaluate the feasibility and safety of coronary computed tomography angiography (CCTA) as the first-line investigation in heart transplant patients and the rate of coronary allograft vasculopathy detected using CCTA. METHODS: From September 2003 to June 2009, we prospectively included 65 heart transplant recipients, retaining 62 who underwent yearly CCTA for coronary allograft vasculopathy detection (261 CCTAs). We used 16-slice, 64-slice, and 2×64-slice CT machines. Patients with coronary artery stenosis by CCTA had a confirmation and a further follow-up exclusively by conventional coronary angiography (CCA). RESULTS: No major coronary events occurred during the study. Of the 62 baseline CCTAs, 37 (60%) were normal, 18 (29%) showed wall thickening, and 7 (11%) known significant stenosis, confirmed by CCA. The mean follow-up duration was 5 years. At the last follow-up, 26 (70%) patients with normal baseline findings remained normal, 9 (24%) had wall thickening, and 2 (6%) significant stenoses. Time to stenosis was consistently greater than 3 years. Of the 18 patients with initially wall thickening, 14 (78%) had wall thickening and 4 (22%) significant stenosis at last follow-up. The mean interval without any coronary lesion was 9.46±3.98 years. The mean interval without de novo significant stenosis was 10.31±4 years. CONCLUSIONS: CCTA seems to be a safe noninvasive tool for monitoring heart transplant patients, and thus obviating the need for CCA. In patients with normal baseline CCTA, a 2-year interval between CCTAs may be safe.


Assuntos
Angiografia/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Cardiopatias/cirurgia , Transplante de Coração , Tomografia Computadorizada Espiral/métodos , Adolescente , Adulto , Idoso , Angiografia/efeitos adversos , Criança , Pré-Escolar , Angiografia Coronária , Doença da Artéria Coronariana/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Lactente , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos , Tomografia Computadorizada Espiral/efeitos adversos , Resultado do Tratamento , Adulto Jovem
18.
Interact Cardiovasc Thorac Surg ; 12(2): 179-82, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21098509

RESUMO

OBJECTIVES: To prospectively assess the value of multidetector computed tomography (MDCT) for detecting partial anomalous pulmonary venous return (PAPVR) in children with suspected sinus venosus-atrial septal defect (SV-ASD). METHODS: Forty-four children (mean age, 7.3 years; range, nine months-16 years) from whom transthoracic echocardiography (TTE) was inconclusive for the diagnosis underwent MDCT after contrast medium injection. Diagnosis was suspected on TTE by abnormal pulmonary venous return, no visualization of pulmonary venous ostia, or unexpected dilatation of right cavities. The first 11 children also underwent cardiac catheterization. Surgical findings constituted the diagnostic reference standard. RESULTS: Thirty-two (73%) children had SV-ASD with PAPVR. Of the first 11 patients, one had PAPVR by MDCT and 10 by conventional angiography; these 11 patients had PAPVR by surgery. Of the remaining 33 patients, 21 had SV-ASD and 12 had ostium secundum ASD, by both MDCT and surgery. MDCT had 100% sensitivity, 100% specificity, 100% positive predictive value, and 100% negative predictive value for diagnosing PAPVR in patients with suspected SV-ASD. CONCLUSION: Contrast-enhanced MDCT is a highly accurate, minimally-invasive technique for detecting PAPVR associated with SV-ASD. Contrast-enhanced MDCT may be used safely to replace conventional angiography for the definitive diagnosis and preoperative evaluation of children with suspected SV-ASD.


Assuntos
Cuidados Pré-Operatórios/métodos , Veias Pulmonares/anormalidades , Intensificação de Imagem Radiográfica , Tomografia Computadorizada Espiral/métodos , Adolescente , Procedimentos Cirúrgicos Cardíacos/métodos , Criança , Pré-Escolar , Intervalos de Confiança , Feminino , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Humanos , Lactente , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Sensibilidade e Especificidade
20.
Eur J Cardiothorac Surg ; 36(2): 413-4, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19524452

RESUMO

Bronchopulmonar intralobar sequestrations receive their arterial blood supply through anomalous arteries from the systemic circulation. Usually the lumen of the aberrant artery can be oversized, but it is unusual to find a true arterial aneurysm. Here, we report a case of a 40-year-old woman with this unusual evolution. Because of the potential risk of rupture, she was treated with a lobectomy associated with a resection of the aneurysm.


Assuntos
Aneurisma/etiologia , Sequestro Broncopulmonar/complicações , Artéria Pulmonar , Adulto , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Feminino , Humanos , Pneumonectomia/métodos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA