Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
2.
J Card Surg ; 36(10): 3881-3883, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34145631

RESUMO

In this case report, we describe how to recycle the left internal thoracic artery (LITA) when misused but not damaged. Eight years after a left anterior small thoracotomy followed by left anterior descending (LAD) stenting for STEMI in first postoperative day, a 67-years-old woman had an NSTEMI with angiographic evidence of intrastent re-stenosis with a perfectly patent LITA, harvested only from the fourth to the sixth intercostal space. During redo surgery, LITA was harvested as a pedicle from the anastomosis to the fourth intercostal space and primarily from the first to the fourth intercostal space. Special attention was paid at the level of the fourth intercostal space where the vessel was stuck to the sternum: a 15-blade was used being scissors or cautery too dangerous. At the end of harvesting, the LITA was full-length available for a new coronary anastomosis on LAD, distal to the previous one.


Assuntos
Artéria Torácica Interna , Idoso , Feminino , Humanos , Artéria Torácica Interna/diagnóstico por imagem , Artéria Torácica Interna/cirurgia , Esterno/cirurgia , Toracotomia
3.
Medicina (Kaunas) ; 57(9)2021 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-34577832

RESUMO

Background and Objectives: Aortic arch disease is still a high-risk surgical challenge despite major advances both in surgical and anesthesiological management. A combined surgical and endovascular approach has been proposed for aortic arch disease treatment to avoid hypothermia and circulatory arrest in high-risk patients. Materials and Methods: Between June 2004 and June 2021, 112 patients were referred to our department for aortic arch surgery; 38 (33.9%) patients underwent supra-aortic debranching and endovascular treatment. Of these, 21 (55%) patients underwent type I aortic arch hybrid debranching procedure and in 17 (45%) patients a type II aortic arch hybrid debranching procedure was performed. None of the patients were emergent. Results: No intra-operative deaths were recorded. In the type I aortic arch hybrid debranching patients' group, one patient died at home waiting the endovascular step, one developed ascending aortic dissection and another one developed a pseudoaneurysm at the site of the debranching at follow-up. In the type II aortic arch hybrid debranching patients' group, left carotid artery branch closure was detected at follow-up in one patient. Thirty day/in-hospital rates of adverse neurological events for both the surgical and endovascular procedures were 3% for minor stroke, with no permanent neurological deficit and 0% for permanent paraplegia/paraparesis. In 100% of the cases, the endovascular step succeeded and the type Ia endoleak rate was 0%. Conclusions: Hybrid arch surgery is a valuable option for aortic arch aneurysm treatment in patients with high surgical risk. The choice of aortic arch debranching between type I or type II is crucial and depends on anatomic and clinical patient characteristics. Further larger scale studies are needed to better define the advantages of these techniques.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Humanos , Estudos Retrospectivos , Fatores de Risco , Stents , Resultado do Tratamento
4.
Ann Vasc Surg ; 49: 107-114, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29481924

RESUMO

BACKGROUND: We report the results of the operative treatment of synchronous type B acute aortic dissection (TBAAD) and infrarenal abdominal aortic aneurysm (AAA). METHODS: It is an observational, descriptive multicenter case series. Inclusion criterion was patients with diagnosis of TBAAD and AAA detected synchronously for the first time at clinical onset of dissection. Follow-up imaging protocol included triple-phase spiral/computed tomography angiography performed at 1, 6, and 12 months after thoracic endovascular aortic repair (TEVAR), and annually thereafter. Major end points were perioperative mortality and long-term survival, freedom from aortic events, and freedom from reintervention. RESULTS: We identified and treated 15 cases. All TBAADs were treated by TEVAR in the acute phase: infrarenal aortic repair was performed with stent graft (SG) in 10 (66.7%) patients, with open repair in 5 (33.3%). Overall, staged repair was used in 11 (73.3%) patients. Mean descending aortic endovascular length coverage was 21 cm ± 7 (range, 10-35; interquartile range [IQR], 150-265). Overall, early perioperative mortality occurred in 1 (6.7%) patient. Median radiologic follow-up was 48 months (range, 6-120; IQR, 36-67). During the follow-up, TEVAR-related mortality was not observed. Aortic remodeling after TEVAR was obtained in 12 (85.7%) patients; abdominal sac shrinkage after SG was obtained in 8 (80.0%) patients. Freedom from aortic event rate was 79% ± 10 (95% confidence interval [CI]: 53.1-92.6) at 1 year and 64% ± 13 (95% CI: 38.1-83.5) at 5 year. Freedom from reintervention rate at 1 and 5 year was 85% ± 10 (95% CI: 57.8-95.7). CONCLUSIONS: In our experience, the association of TBAAD and AAA was a rare finding. Because of the lack of available evidence to opt for a single intervention or a staged approach, selective approach with TEVAR and endovascular/open conventional treatment of the abdominal aorta yielded satisfactory results at midterm follow-up.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Dissecção Aórtica/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/metabolismo , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Bases de Dados Factuais , Intervalo Livre de Doença , Feminino , Humanos , Itália , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Retratamento , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada Espiral , Resultado do Tratamento , Remodelação Vascular
5.
J Heart Valve Dis ; 26(1): 12-17, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28544826

RESUMO

BACKGROUND: Stabilization of the ventriculo-aortic junction (VAJ) is gaining increasing interest in the context of aortic valve repair, since its dilation is a well-recognized risk factor for long-term repair failure. Interleaflets triangles are key elements of the VAJ, but cannot be completely visualized using echocardiography. A three-dimensional (3D) reconstruction of electrocardiogram-triggered computed tomography (CT) scan images allows an analysis of the real dimensions and anatomic characteristics of the subcommissural triangles. METHODS: A method was developed to visualize the interleaflets triangle at the CT-scan based on multiplanar post-processing reconstructions. Attention was focused on the triangles' apical angle evaluation. The data obtained with CT-scan reconstructions were compared with those collected in a previous post-mortem study to validate this measurement method. RESULTS: In the CT-scan group the angles between the left and right coronary sinuses, and the right non-coronary and left non-coronary sinuses were 46.23 ± 7.79°, 47.38 ± 6.97°, 45° [range: 42.75- 50.75°], respectively, and in the post-mortem group were 45.44 ± 12.39°, 48.31 ± 1218°, 50.25 ± 7.29°. No statistically significant differences between the two groups were identified (p = 0.84, 0.81, and 0.23). CONCLUSIONS: Based on experience acquired in the operating room, the acute-angle subcommissural triangles were considered normal, the equilateral triangles mildly dilated, and the obtuse triangles severely dilated. According to this classification, different reparative approaches were selected. A CTscan 3D reconstruction method, as validated by the present data, allows a preoperative evaluation of the triangles and VAJ in order to best plan a surgical reparative approach tailored to a single patient.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Aorta , Ecocardiografia , Humanos , Tomografia Computadorizada por Raios X
6.
J Artif Organs ; 19(4): 350-356, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27230086

RESUMO

Pericardial and porcine stented aortic valves have different leaflet kinematics. To study the biomechanics of a prosthesis thoroughly, the in vitro setting is the most appropriate. The aim of our study was to find out whether the prosthesis design in which the pericardial sheet is outside the stent post might influence the opening and closing patterns of the leaflets. Four pericardial prostheses (Magna Ease [MG] 21, Trifecta [TRI] 21, Soprano-Armonia [SA] 20 and Mitroflow [MF] 23) that fitted aortic roots with a native annulus diameter of 2.1 cm were implanted and their leaflet kinematics was studied by a high-speed digital camera. In the opening phase, MG showed the shortest RVOT and the highest RVOVI, with values of 12 ± 2 and 209 ± 17 ms, respectively. The RVOT of MG was significantly shorter than that of MF (p < 0.01), but not than that of TRI (p = 0.286). Both TRI and SA showed similar opening patterns (TRI: RVOT of 15 ± 3 ms and RVOVI of 132 ± 25 ms; SA: 17 ± 2 ms and 126 ± 19 ms), without statistically significant difference. Conversely, MF showed the slowest profile, with an RVOT of 23 ± 3 ms and an RVOVI of 94 ± 8 ms (Table 1; Fig. 3). The opening/closing profile is not influenced by the position of the pericardial leaflets, but depends on other intrinsic structural characteristics related to the material used for the stent and leaflets. Moreover, the kinematics does not affect the valve performance. Table 1 Kinematics and hydrodynamic results, reported as means and standard deviations, evaluated over the tested heart samples TRI SA MG MF ANOVA TRI versus SA TRI versus MG TRI versus MF SA versus MG SA versus MF MG versus MF p Value p Value p Value p Value p Value p Value p Value ET (ms) 1.0 1.0 1.0 1.0 RVOT (ms) 15 ± 3 17 ± 2 12 ± 2 23 ± 3 <0.01 1.0 0.286 <0.01 0.03 <0.01 <0.01 SVCT (ms) 247 ± 14 231 ± 15 256 ± 26 241 ± 11 0.170 0.463 0.853 0.931 0.213 1.0 1.0 RVCT (ms) 35 ± 19 52 ± 13 32 ± 17 52 ± 4 0.07 0.474 1.0 0.494 0.236 1.0 0.247 TVCT (ms) 283 ± 10 283 ± 19 289 ± 10 293 ± 11 0.584 1.00 1.0 1.0 1.0 1.0 1.0 RVOVI (ms-1) 132 ± 25 126 ± 19 209 ± 17 94 ± 8 <0.01 0.959 <0.01 0.02 <0.01 0.07 <0.01 SVCVI (ms-1) -0.9 ± 0.3 -1.1 ± 0.4 -0.57 ± 0.1 -0.55 ± 0.1 <0.01 1.0 0.353 0.292 0.045 0.04 1.0 RVCVI (ms-1) -16 ± 4 -10 ± 2 -18 ± 6 -10 ± 1 <0.01 0.396 1.0 0.513 0.025 1.0 0.03 Δp (mmHg) 6.7 ± 3.6 10.6 ± 5.5 15.2 ± 7.9 10.7 ± 6.1 <0.01 0.01 <0.01 0.01 0.04 1.0 <0.01 EOA (cm2) 2.2 ± 1.2 1.7 ± 0.9 1.5 ± 0.8 1.7 ± 0.9 <0.01 0.03 <0.01 0.01 0.261 0.617 0.11 El  % 7.3 ± 1 11.9 ± 1 15.4 ± 2 11.8 ± 3 <0.01 <0.01 <0.01 <0.01 0.04 1.00 0.03 CO (L/min) 3.1 ± 0.4 2.8 ± 0.5 3.1 ± 0.3 3.0 ± 0.5 0.534 0.282 0.792 0.702 0.106 0.552 0.559 ET ejection time, RVOT rapid valve-opening time, SVCT slow valve-closing time, RVCT rapid valve-closing time, TVCT total valve-closing time, RVOVI rapid valve-opening velocity index, SVCVI slow valve-closing velocity index, RVCVI rapid valve-closing velocity index, Δp mean pressure drop, EOA effective orifice area, El % energy loss, CO cardiac output.


Assuntos
Valva Aórtica , Bioprótese/estatística & dados numéricos , Próteses Valvulares Cardíacas/estatística & dados numéricos , Animais , Aorta , Fenômenos Biomecânicos , Débito Cardíaco , Hemodinâmica , Humanos , Hidrodinâmica , Técnicas In Vitro , Pericárdio/transplante , Desenho de Prótese , Stents , Suínos
7.
J Heart Valve Dis ; 24(3): 290-1, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26901897

RESUMO

The reimplantation technique is one of the most popular valve-sparing procedures. Previously published in-vitro studies have demonstrated the success of the aortic interleaflets triangle reshaping approach in increasing the coaptation surface. An alternative positioning of the pledgeted stitches used in the proximal suture line of the David operation is proposed to simultaneously stabilize the annulus and improve the valve functional reserve in case of annulo-aortic ectasia due to dilation of the interleaflet triangles.


Assuntos
Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/métodos , Insuficiência da Valva Aórtica/cirurgia , Humanos , Técnicas de Sutura
8.
J Heart Valve Dis ; 24(5): 596-603, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26897839

RESUMO

BACKGROUND AND AIM OF THE STUDY: Many variables may affect the fluid dynamic of an implanted bioprosthesis. In-vitro studies have provided accurate data such that, when different prostheses are implanted in the same true aortic root, it should be possible to make a fair comparison. The study aim was to evaluate the fluid dynamic and geometric characteristics of the four most widely used stented pericardial bioprostheses. METHODS: Four types of pericardial prosthesis (Magna Ease 21, Trifecta 21, Soprano-Armonia 20, and Mitroflow 23) that fitted eight aortic roots with a native annulus diameter of 2.1 cm were implanted and tested in a mock loop. RESULTS: Energy loss and mean gradients were increased with stroke volume (SV) in all valves tested. The effective orifice area values were fairly stable across the SV intervals (p = 0.57). All hemodynamic-related indices displayed mutually consistent behaviors, with Trifecta showing the lowest hindrance to flow. Both geometric orifice area (GOA) and edge geometric orifice area (eGOA) were increased significantly as the SV increased; the Trifecta valve showed the largest eGOA value, while the Trifecta and Mitroflow provided the largest GOAs. For the Trifecta and Soprano-Armonia prostheses (and the Magna to a lesser extent), the most distal cross-section was systematically greater than the inflow area, suggesting a divergent configuration at the systolic peak. CONCLUSION: The study results combined the fluid dynamic reproducibility of the in-vitro setting and the specificity of surgery. A quantitative comparison of the fluid dynamic performance of the different bioprostheses was feasible.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemodinâmica , Modelos Cardiovasculares , Pericárdio/transplante , Stents , Animais , Valva Aórtica/fisiopatologia , Simulação por Computador , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hidrodinâmica , Técnicas In Vitro , Teste de Materiais , Desenho de Prótese , Suínos
10.
J Heart Valve Dis ; 23(1): 122-6, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24779338

RESUMO

BACKGROUND AND AIM OF THE STUDY: Quadricuspid aortic valve (QAV) is an extremely rare congenital defect in which the valve features an additional fourth cusp. It is often associated with an alteration in valve functionality such as valve regurgitation, stenosis and coronary disease. These associated pathologies entail surgical correction in about 50% of patients at a mean age of 50 years. METHODS: A swine QAV was studied in a pulsatile mock loop in the laboratory. Rest (70 bpm) and exercise (100 bpm) conditions were simulated, and opening and closing kinematics were evaluated from a high-speed video. Short- and long-axis echocardiograms were recorded. The pressure drop across the valve, valve competence and effective orifice area were evaluated and compared to data from healthy samples tested in the same experimental apparatus. RESULTS: Hemodynamic quantities were physiologic-like, despite the QAV showing an altered kinematics (longer closing and opening times compared to healthy samples) and an asynchronous closing phase (the extra cusps reached the closed configuration at the end of systole systematically earlier with respect to the other three cusps). Echocardiographic data showed an increased coaptation height between the left and right coronary cusps, and a mismatch between the lunule of the extra cusp and the non-coronary cusp. CONCLUSION: The altered kinematics, together with incorrect coaptation, can alter the biomechanics of the structure, inducing an anomalous distribution of local stress which could lead to structural failure over time.


Assuntos
Valva Aórtica/anormalidades , Valva Aórtica/fisiopatologia , Modelos Cardiovasculares , Animais , Valva Aórtica/diagnóstico por imagem , Fenômenos Biomecânicos , Ecocardiografia , Frequência Cardíaca/fisiologia , Hemodinâmica/fisiologia , Técnicas In Vitro , Fluxo Pulsátil/fisiologia , Gravação em Vídeo
11.
J Heart Valve Dis ; 23(4): 424-31, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25803968

RESUMO

BACKGROUND AND AIM OF THE STUDY: Subcommissural triangles reshaping is a reparative technique used to remodel the ventriculo-aortic junction. The study aim was to evaluate, by means of in-vitro testing, the effects of this technique on hemodynamics, leaflet kinematics and aortic root functional unit morphology. METHODS: Twenty-one porcine aortic roots were tested in a pulsatile mock loop under basal conditions and after subcommissural triangles reshaping performed at 50% of the interleaflet triangles height. During each test, hydrodynamic quantities, high-speed digital videos and echocardiographic images were recorded. RESULTS: The comparison between pre- and post-surgery data showed a statistically significant increase in coaptation height (p < 0.01) and length (p < 0.01). Significant reductions were found in the virtual basal ring diameter (p < 0.01), sinus of Valsalva diameters (p < 0.01), maximum leaflet opening (p < 0.01), leaflet opening before rapid valve closing time (p < 0.01) and maximum opening area (p < 0.01). An opened valve time reduction (p <0.01) was observed due to an opening time reduction (p < 0.01), offset by a closed valve time increase (p < 0.01). A slow closing period increase (p < 0.07) and a rapid closing phase reduction (p < 0.01), were also highlighted without influence on the total closing time. A statistical, but not clinically significant, increase in pressure drop across the valve (p < 0.01) and an effective orifice area reduction (p < 0.01) were observed. CONCLUSION: Subcommissural triangles reshaping performed at 50% of the interleaflet triangles' height determines an increase in leaflet coaptation by remodeling the ventriculo-aortic junction. Some hydrodynamic and kinematic changes also occur, without any acute clinically threatening alterations.


Assuntos
Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/métodos , Animais , Valva Aórtica/patologia , Fenômenos Biomecânicos , Hemodinâmica , Hidrodinâmica , Técnicas In Vitro , Suínos
12.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38212996

RESUMO

OBJECTIVES: In the last decades, 4 different scores for the prediction of mortality following surgery for type A acute aortic dissection (TAAD) were proposed. We aimed to validate these scores in a large external multicentre cohort. METHODS: We retrospectively analysed patients who underwent surgery for TAAD between 2000 and 2020. Patients were enrolled from 10 centres from 2 European countries. Outcomes were the early (30-day and/or in-hospital) and 1-year mortality. Discrimination, calibration and observed/expected (O/E) ratio were evaluated. RESULTS: A total of 1895 patients (31.7% females, mean age 63.72 ± 12.8 years) were included in the study. Thirty-day mortality and in-hospital mortality were 21.7% (n = 412) and 22.5% (n = 427) respectively. The German Registry of Acute Aortic Dissection Type A (GERAADA) score shows to have the best discrimination [area under the curve (AUC) 0.671 and 0.672] in predicting as well the early and the 1-year mortality, followed by the International Registry of Acute Aortic Dissection (IRAD) model 1 (AUC 0.658 and 0.672), the Centofanti (AUC 0.645 and 0.66) and the UK aortic score (AUC 0.549 and 0.563). According to Hosmer-Lemeshow and Brier tests, the IRAD model I and GERAADA, respectively, were well calibrated for the early mortality, while the GERAADA and Centofanti for the 1-year mortality. The O/E analysis showed a marked underestimation for patients labelled as low-risk for UK aortic score and IRAD model I for both outcomes. CONCLUSIONS: The GERAADA score showed the best performance in comparison with other scores. However, none of them achieved together a fair discrimination and a good calibration for predicting either the early or the 1-year mortality.


Assuntos
Dissecção Aórtica , Azidas , Desoxiglucose/análogos & derivados , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Estudos Retrospectivos , Dissecção Aórtica/cirurgia , Mortalidade Hospitalar , Europa (Continente) , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
13.
Artigo em Inglês | MEDLINE | ID: mdl-24403952

RESUMO

A narrative review of the major evidence concerning the relationship between anxiety, social support and cardiac disease was conducted. Literature demonstrates that a strict relationship between anxiety, social support and cardiac disease outcomes subsists. However, the function of social support within anxiety and heart disease association remains unclear and needs to further researches to be established. Moreover evidence suggests that it's the quality of close relationships to play an important role in affecting psychological and physiological health status. The main components that the literature suggests for a better quality of social support and close relationship, and the main assessment measure are presented. Evidence about cardiac rehabilitation programs and the need to assess and intervene on psychological and psychosocial factors is discussed.

14.
Ann Biomed Eng ; 51(4): 715-725, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36151505

RESUMO

Emerging treatments for tricuspid valve (TV) regurgitation require realistic TV pathological models for preclinical testing. The aim of this work was to investigate structural features of fresh and defrosted porcine right-heart samples as models of mild and severe functional tricuspid regurgitation (FTR) condition in ex-vivo pulsatile flow platform. Ten fresh hearts were tested ex-vivo under steady and pulsatile flow in typical right-heart loading conditions. Hemodynamics and 3D echocardiographic imaging of TV and right ventricle (RV) were acquired. Hearts were then kept frozen for 14 days, defrosted, and tested again with the same protocol. Morphometric parameters of TV and RV were derived from 3D reconstructions based on echo data. Fresh samples showed a slightly dilated TV morphology, with coaptation gaps among the leaflets. Sample freezing induced worsening of TV insufficiency, with significant (p < 0.05) increases in annulus size (annulus area and perimeter 7.7-3.1% respectively) and dilation of RV (9.5%), which led to an increase in tenting volume (123.7%). These morphologic alterations reflected into a significant increment of regurgitation fraction (27%). Together, such results suggest that fresh porcine heart samples may be a reliable ex-vivo model of mild FTR condition, which can be enhanced through freezing/thawing treatment to model a severe pathological condition.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Tricúspide , Suínos , Animais , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/diagnóstico por imagem , Ventrículos do Coração
15.
J Cardiovasc Transl Res ; 16(4): 956-967, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37097591

RESUMO

Coronary flow obstruction following transcatheter aortic valve-in-valve implantation (VIV-TAVI) is associated with a high mortality risk. The aim of this work was to quantify the coronary perfusion after VIV-TAVI in a high-risk aortic root anatomy. 3D printed models of small aortic root were used to simulate the implantation of a TAVI prosthesis (Portico 23) into surgical prostheses (Trifecta 19 and 21). The aortic root models were tested in a pulsatile in vitro bench setup with a coronary perfusion simulator. The tests were performed at baseline and post-VIV-TAVI procedure in aligned and misaligned commissural configurations under simulated hemodynamic rest and exercise conditions. The experimental design provided highly controllable and repeatable flow and pressure conditions. The left and right coronary mean flow did not differ significantly at pre- and post-VIV-TAVI procedure in any tested configurations. The commissural misalignment did not induce any significant alterations to the coronary flow. High-risk aortic root anatomy did not trigger coronary ostia obstruction or coronary flow alteration after transcatheter aortic valve implantation in a surgical bioprosthesis as shown from in-vitro flow loop tests.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Oclusão Coronária , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Aorta Torácica/cirurgia , Falha de Prótese , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Perfusão , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Resultado do Tratamento
16.
Eur J Cardiothorac Surg ; 61(3): 647-654, 2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-34363669

RESUMO

OBJECTIVES: Commissural orientation <160° is a recognized risk factor for bicuspid aortic valve repair failure. Based on this observation, repairing this subtype of aortic valve by reorienting the 2 commissures at 180° has recently been proposed. METHODS: Nine porcine hearts with aortic annulus diameters of 25 mm were selected. A pathological model of a Sievers 1 bicuspid aortic valve was obtained by suturing the coaptation line between the left and right leaflets. Each heart underwent reimplantation procedures both in the native (120°) and the reoriented (180°) configuration. After the operation, each sample was tested on a pulse duplicator at rest (heart rate 60 beats per min) and with mild exercise (heart rate 90 beats per min) conditions. RESULTS: No statistically significant difference was noted in mean and peak transvalvular aortic gradients between the 2 configurations at rest (18.6 ± 5 vs 17.5 ± 4 for the mean aortic gradient; 42.8 ± 12.7 vs 36.3 ± 5.8 for the peak aortic gradient) but the group with the 120°-oriented commissures had significantly higher mean transaortic gradients compared to the group with the 180°-oriented commissures at initial exercise stress conditions (30.1 ± 9.1 vs 24.9 ± 3.8; p value 0.002). CONCLUSIONS: The 180° commissural reorientation of the asymmetrical bicuspid aortic valve does not improve the transvalvular aortic gradient in an acute model at rest conditions, but it could do so under stress situations. Even if it is surgically more complex and time-consuming, this approach could be a good strategy to improve long-term results, particularly in young patients.


Assuntos
Insuficiência da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Animais , Valva Aórtica/patologia , Insuficiência da Valva Aórtica/cirurgia , Humanos , Estudos Retrospectivos , Suínos , Resultado do Tratamento
17.
Front Cardiovasc Med ; 9: 850393, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35402526

RESUMO

The increasing incidence of calcific aortic valve disease necessitates the elaboration of new strategies to retard the progression of the pathology with an innovative solution. While the increasing diffusion of the transcatheter aortic valve replacements (TAVRs) allows a mini-invasive approach to aortic valve substitution as an alternative to conventional surgical replacement (SAVR) in an always larger patient population, TAVR implantation still has contraindications for young patients. In addition, it is liable to undergo calcification with the consequent necessity of re-intervention with conventional valve surgery or repeated implantation in the so-called TAVR-in-TAVR procedure. Inspired by applications for non-cardiac pathologies or for vascular decalcification before stenting (i.e., coronary lithotripsy), in the present study, we show the feasibility of human valve treatment with a mini-invasive device tailored to deliver shockwaves to the calcific leaflets. We provide evidence of efficient calcium deposit ruptures in human calcified leaflets treated ex vivo and the safety of the treatment in pigs. The use of this device could be helpful to perform shockwaves valvuloplasty as an option to retard TAVR/SAVR, or as a pretreatment to facilitate prosthesis implantation and minimize the occurrence of paravalvular leak.

19.
Artigo em Inglês | MEDLINE | ID: mdl-34143578

RESUMO

We propose a technique to minimize the neurological and systemic risks involved in rerouting the blood flow toward the brain in a "single remaining vessel" configuration with a 90% stenosis by means of complete hypothermic cerebral protection associated with normothermic systemic blood flow with a "restitutio ad integrum" of the supra-aortic trunks flow. The perfusion of the brain and the arms was almost completely separated from the systemic perfusion by the deployment 1 year before of a thoracic endoprosthesis in association with complete chronic occlusion of the brachiocephalic trunk and a functioning carotid-subclavian bypass. The Free Flow of the prosthesis, which acted as a hook, moved the calcium toward the left carotid ostium, creating a 90% stenosis with intermittent acute cerebral hypoperfusion and amaurosis. We achieved an optimal result: The patient was discharged on postoperative day 7 with no neurological problems and with patency and direct blood flow in all the supra-aortic trunks.


Assuntos
Aorta Torácica/cirurgia , Procedimentos Endovasculares/métodos , Prótese Vascular/efeitos adversos , Tronco Braquiocefálico/cirurgia , Isquemia Encefálica/etiologia , Isquemia Encefálica/cirurgia , Estenose das Carótidas/cirurgia , Feminino , Humanos , Pessoa de Meia-Idade
20.
Int J Artif Organs ; 43(7): 468-475, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31894714

RESUMO

BACKGROUND: Bioprostheses are complex structures and yield a very complex fluid dynamics. Hence, it can be hypothesized that prosthesis structural characteristics affect the position of the vena contracta and, consequently, influences the pattern and the extent of pressure recovery downstream from the vena contracta. MATERIALS AND METHODS: The study was performed on pericardial aortic prostheses, specifically Crown 21 and 23 (LivaNova PLC, UK), Trifecta 19 and 21 (Edwards Lifescience, USA), and Magna 19 and 21(Abbott, USA), tested in an "ad hoc" devised steady flow loop circuit at four flow rates (10, 15, 20, and 25 L/min). Fluid dynamic quantities were obtained by direct pressure measurement and Doppler interrogation. RESULTS: Pressure drop at 25 L/min flow rate was 26.5 ± 0.3 mm Hg and 14.9 ± 0.1 mm Hg for the Trifecta 19 and 21, 37.1 ± 1.0 mm Hg and 27.3 ± 0.4 mm Hg for the Magna 19 and 21, and 36.6 ± 1.0 mm Hg and 22.7 ± 0.1 mm Hg for Crown 21 and 23, respectively. The vena contracta was shorter for Trifecta compared with the Magna and the Crown in which it developed further downstream and as far as 1 cm from the valve leaflets fringes. The pressure recovery was 54% ± 1% for Trifecta 21, 39% ± 1% for Magna 21, and 41% ± 2% for Crown 23 with different patterns. CONCLUSION: The design of bioprosthesis affects pressure recovery and the position of the vena contracta. The different patterns of pressure recovery might have clinical impact.


Assuntos
Valva Aórtica/fisiopatologia , Bioprótese , Próteses Valvulares Cardíacas , Desenho de Prótese , Valva Aórtica/cirurgia , Pressão Sanguínea/fisiologia , Implante de Prótese de Valva Cardíaca , Hemodinâmica , Humanos , Modelos Cardiovasculares , Pericárdio/transplante
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA