Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Chem Phys ; 144(8): 084903, 2016 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-26931722

RESUMO

We report on high pressure small angle x-ray scattering on suspensions of colloidal crystallites in water. The crystallites made out of charge-stabilized poly-acrylate particles exhibit a complex pressure dependence which is based on the specific pressure properties of the suspending medium water. The dominant effect is a compression of the crystallites caused by the compression of the water. In addition, we find indications that also the electrostatic properties of the system, i.e. the particle charge and the dissociation of ions, might play a role for the pressure dependence of the samples. The data further suggest that crystallites in a metastable state induced by shear-induced melting can relax to a similar structural state upon the application of pressure and dilution with water. X-ray cross correlation analysis of the two-dimensional scattering patterns indicates a pressure-dependent increase of the orientational order of the crystallites correlated with growth of these in the suspension. This study underlines the potential of pressure as a very relevant parameter to understand colloidal crystallite systems in aqueous suspension.

2.
Opt Express ; 21(21): 24647-64, 2013 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-24150309

RESUMO

The single shot based coherence properties of hard x-ray pulses from the Linac Coherent Light Source (LCLS) were measured by analyzing coherent diffraction patterns from nano-particles and gold nanopowder. The intensity histogram of the small angle x-ray scattering ring from nano-particles reveals the fully transversely coherent nature of the LCLS beam with a number of transverse mode 〈Ms〉 = 1.1. On the other hand, the speckle contrasts measured at a large wavevector yields information about the longitudinal coherence of the LCLS radiation after a silicon (111) monochromator. The quantitative agreement between our data and the simulation confirms a mean coherence time of 2.2 fs and a x-ray pulse duration of 29 fs. Finally the observed reduction of the speckle contrast generated by x-rays with pulse duration longer than 30 fs indicates ultrafast dynamics taking place at an atomic length scale prior to the permanent sample damage.

3.
Phys Rev Lett ; 109(18): 185502, 2012 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-23215295

RESUMO

The availability of ultrafast pulses of coherent hard x rays from the Linac Coherent Light Source opens new opportunities for studies of atomic-scale dynamics in amorphous materials. Here, we show that single ultrafast coherent x-ray pulses can be used to observe the speckle contrast in the high-angle diffraction from liquid Ga and glassy Ni(2)Pd(2)P and B(2)O(3). We determine the thresholds above which the x-ray pulses disturb the atomic arrangements. Furthermore, high contrast speckle is observed in scattering patterns from the glasses integrated over many pulses, demonstrating that the source and optics are sufficiently stable for x-ray photon correlation spectroscopy studies of dynamics over a wide range of time scales.


Assuntos
Vidro/química , Modelos Teóricos , Difração de Raios X/métodos , Compostos de Boro/química , Gálio/química , Níquel/química , Paládio/química , Fósforo/química , Fótons
4.
Phys Rev Lett ; 108(2): 024801, 2012 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-22324689

RESUMO

We measured the transverse and longitudinal coherence properties of the Linac Coherent Light Source (LCLS) at SLAC in the hard x-ray regime at 9 keV photon energy on a single shot basis. Speckle patterns recorded in the forward direction from colloidal nanoparticles yielded the transverse coherence properties of the focused LCLS beam. Speckle patterns from a gold nanopowder recorded with atomic resolution allowed us to measure the shot-to-shot variations of the spectral properties of the x-ray beam. The focused beam is in the transverse direction fully coherent with a mode number close to 1. The average number of longitudinal modes behind the Si(111) monochromator is about 14.5 and the average coherence time τ(c)=(2.0±1.0) fc. The data suggest a mean x-ray pulse duration of (29±14) fs behind the monochromator for (100±14) fc electron pulses.


Assuntos
Ouro/química , Luz , Nanopartículas Metálicas/química , Modelos Teóricos , Nanoestruturas/química , Fótons , Elétrons , Aceleradores de Partículas , Espalhamento de Radiação , Raios X
5.
Rev Sci Instrum ; 90(4): 045106, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31042974

RESUMO

We present a novel experimental setup for performing a precise pre-alignment of a hard X-ray split-and-delay unit based on low coherence light interferometry and high-precision penta-prisms. A split-and-delay unit is a sophisticated perfect crystal-optics device that splits an incoming X-ray pulse into two sub-pulses and generates a controlled time-delay between them. While the availability of a split-and-delay system will make ultrafast time-correlation and X-ray pump-probe experiments possible at free-electron lasers, its alignment process can be very tedious and time-consuming due to its complex construction. By implementing our experimental setup at beamline P10 of PETRA III, we were able to reduce the time of alignment to less than 3 h. We also propose an alternate method for finding the zero-time delay crossing without the use of X-rays or pulsed laser sources. The successful demonstration of this method brings prospect for operating the split-and-delay systems under alignment-time-critical environments such as X-ray free electron laser facilities.

6.
Nat Commun ; 9(1): 1704, 2018 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-29703980

RESUMO

One of the important challenges in condensed matter science is to understand ultrafast, atomic-scale fluctuations that dictate dynamic processes in equilibrium and non-equilibrium materials. Here, we report an important step towards reaching that goal by using a state-of-the-art perfect crystal based split-and-delay system, capable of splitting individual X-ray pulses and introducing femtosecond to nanosecond time delays. We show the results of an ultrafast hard X-ray photon correlation spectroscopy experiment at LCLS where split X-ray pulses were used to measure the dynamics of gold nanoparticles suspended in hexane. We show how reliable speckle contrast values can be extracted even from very low intensity free electron laser (FEL) speckle patterns by applying maximum likelihood fitting, thus demonstrating the potential of a split-and-delay approach for dynamics measurements at FEL sources. This will enable the characterization of equilibrium and, importantly also reversible non-equilibrium processes in atomically disordered materials.

7.
Rev Sci Instrum ; 89(3): 036103, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29604789

RESUMO

A transmission polarizer for producing elliptically polarized soft X-ray radiation from linearly polarized light is presented. The setup is intended for use at synchrotron and free-electron laser beamlines that do not directly offer circularly polarized light for, e.g., X-ray magnetic circular dichroism (XMCD) measurements or holographic imaging. Here, we investigate the degree of ellipticity upon transmission of linearly polarized radiation through a cobalt thin film. The experiment was performed at a photon energy resonant to the Co L3-edge, i.e., 778 eV, and the polarization of the transmitted radiation was determined using a polarization analyzer that measures the directional dependence of photo electrons emitted from a gas target. Elliptically polarized radiation can be created at any absorption edge showing the XMCD effect by using the respective magnetic element.

8.
Rev Sci Instrum ; 87(6): 063905, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27370468

RESUMO

In this paper we describe a setup for x-ray scattering experiments on complex fluids using a liquid jet. The setup supports Small and Wide Angle X-ray Scattering (SAXS/WAXS) geometries. The jet is formed by a gas-dynamic virtual nozzle (GDVN) allowing for diameters ranging between 1 µm and 20 µm at a jet length of several hundred µm. To control jet properties such as jet length, diameter, or flow rate, the instrument is equipped with several diagnostic tools. Three microscopes are installed to quantify jet dimensions and stability in situ. The setup has been used at several beamlines performing both SAXS and WAXS experiments. As a typical example we show an experiment on a colloidal dispersion in a liquid jet at the X-ray Correlation Spectroscopy instrument at the Linac Coherent Light Source free-electron laser.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA