Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Cytometry B Clin Cytom ; 72(5): 387-96, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17474130

RESUMO

BACKGROUND: Various assays are used to enumerate peripheral blood absolute CD4+ T-lymphocytes. Flow cytometry is considered the gold standard for this purpose. However, the high cost of available flow cytometers and monoclonal antibody reagents make it difficult to implement such methods in the resource-poor settings. In this study, we evaluated a cheaper, recently developed single-platform microcapillary cytometer for CD4+ T-lymphocyte enumeration, the personal cell analyzer (PCA), from Guava Technologies. METHODS: CD4+ and CD8+ T-lymphocyte counts in whole blood samples from 250 HIV-1 infected Thais were determined, using a two-color reagent kit and the Guava PCA, and compared with the results obtained with two reference microbead-based methods from Becton Dickinson Biosciences: the three-color TruCOUNT tube method and the two-color FACSCount method. Statistical correlations and agreements were determined using linear correlation and Bland-Altman analysis. RESULTS: Absolute CD4+ T-lymphocyte counts obtained using the Guava PCA method highly correlated with those obtained using TruCOUNT method (R(2) = 0.95, mean bias +13.1 cells/microl, limit of agreement [LOA]-117.9 to +144.1 cells/microl) and the FACSCount method (R2 = 0.94, mean bias = +33.2 cells/microl, LOA-101.8 to +168.3 cells/microl). Absolute CD8+ T-lymphocyte counts obtained using the Guava PCA method also highly correlated with those obtained with the two reference methods (R(2) = 0.92 and 0.88, respectively). CONCLUSION: This study shows that the enumeration of CD4+ T-lymphocytes using the Guava microcapillary cytometer PCA method performed well when compared with the two reference bead-based methods. However, like the two reference methods, this new method needs substantial technical expertise.


Assuntos
Contagem de Linfócito CD4/instrumentação , Linfócitos T CD4-Positivos/imunologia , Citometria de Fluxo/instrumentação , Infecções por HIV/diagnóstico , Infecções por HIV/imunologia , Contagem de Linfócito CD4/economia , Contagem de Linfócito CD4/métodos , Linfócitos T CD4-Positivos/virologia , Linfócitos T CD8-Positivos/imunologia , Análise Custo-Benefício , Citometria de Fluxo/economia , Citometria de Fluxo/métodos , Infecções por HIV/sangue , Humanos , Indicadores e Reagentes/normas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Tailândia
2.
Clin Diagn Lab Immunol ; 12(12): 1416-24, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16339065

RESUMO

Use of the standard dual-platform flow cytometric method for determination of CD4(+) T-lymphocyte counts, which needs both a flow cytometer (FCM) and hematological analyzer, would inevitably lead to increased variability. The development of new single-platform (SP) FCMs that provide direct CD4(+) T-lymphocyte counts for improved assay precision and accuracy have recently attracted attention. This study evaluated one of those systems, CyFlow(green) (Partec), a single-parameter SP volumetric FCM. The performance of CyFlow(green) was compared with those of two reference standard SP microbead-based technologies of the three-color TruCOUNT tube with the FACScan FCM and a two-color FACSCount system (Becton Dickinson Biosciences). Absolute CD4(+) and CD8(+) T-lymphocyte counts in 200 human immunodeficiency virus type 1-seropositive blood specimens were determined. Statistical analysis for correlation and agreement were performed. A high correlation of absolute CD4 counts was shown when those obtained with CyFlow(green) were compared with those obtained with the bead-based three-color TruCOUNT system (R(2)=0.96; mean bias, -69.1 cells/microl; 95% confidence interval [CI], -225.7 to+87.5 cells/microl) and the FACSCount system (R(2)=0.97; mean bias, -40.0 cells/microl; 95% CI, -165.1 to+85.1 cells/microl). The correlation of the CD4(+) T-lymphocyte counts obtained by the two bead-based systems was high (R(2)=0.98). Interestingly, CyFlow(green) yielded CD4(+) T-lymphocyte counts that were 21.8 and 7.2 cells/microl lower than those obtained with the TruCOUNT and the FACSCount systems, respectively, when CD4(+) T-lymphocyte counts were <250 CD4(+) T-lymphocyte counts/microl range or 17.3 and 5.8 cells/microl less, respectively, when CD4(+) T-lymphocyte counts were <200 cells/microl. The single-parameter CyFlow(green) volumetric technology performed well in comparison with the performance of the standard SP bead-based FCM system. However, a multicenter comparative study is needed before this FCM machine is implemented in resource-limited settings.


Assuntos
Contagem de Linfócito CD4/métodos , Citometria de Fluxo/métodos , Infecções por HIV/imunologia , HIV-1 , Adulto , Linfócitos T CD8-Positivos , Citometria de Fluxo/instrumentação , Humanos , Modelos Lineares , Contagem de Linfócitos/métodos , Controle de Qualidade , Reprodutibilidade dos Testes , Tailândia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA