Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 25(1): e14217, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38018758

RESUMO

PURPOSE: Chest wall postmastectomy radiation therapy (PMRT) should consider the effects of chest wall respiratory motion. The purpose of this study is to evaluate the effectiveness of robustness planning intensity modulated radiation therapy (IMRT) for respiratory movement, considering respiratory motion as a setup error. MATERIAL AND METHODS: This study analyzed 20 patients who underwent PMRT (10 left and 10 right chest walls). The following three treatment plans were created for each case and compared. The treatment plans are a planning target volume (PTV) plan (PP) that covers the PTV within the body contour with the prescribed dose, a virtual bolus plan (VP) that sets a virtual bolus in contact with the body surface and prescribing the dose that includes the PTV outside the body contour, and a robust plan (RP) that considers respiratory movement as a setup uncertainty and performs robust optimization. The isocenter was shifted to reproduce the chest wall motion pattern and the doses were recalculated for comparison for each treatment plan. RESULT: No significant difference was found between the PP and the RP in terms of the tumor dose in the treatment plan. In contrast, VP had 3.5% higher PTV Dmax and 5.5% lower PTV V95% than RP (p < 0.001). The RP demonstrated significantly higher lung V20Gy and Dmean by 1.4% and 0.4 Gy, respectively, than the PP. The RP showed smaller changes in dose distribution affected by chest wall motion and significantly higher tumor dose coverage than the PP and VP. CONCLUSION: We revealed that the RP demonstrated comparable tumor doses to the PP in treatment planning and was robust for respiratory motion compared to both the PP and the VP. However, the organ at risk dose in the RP was slightly higher; therefore, its clinical use should be carefully considered.


Assuntos
Neoplasias da Mama , Radioterapia de Intensidade Modulada , Parede Torácica , Humanos , Feminino , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica , Mastectomia
2.
J Appl Clin Med Phys ; 25(6): e14330, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38478368

RESUMO

BACKGROUND: This study aimed to evaluate the clinical acceptability of rotational gantry-based single-position carbon-ion radiotherapy (CIRT) to reduce the gastrointestinal (GI) dose in pancreatic cancer. We also evaluated the usefulness of the deformable image registration (DIR)-based dosimetry method for CIRT. MATERIAL AND METHODS: Fifteen patients with pancreatic cancer were analyzed. The treatment plans were developed for four beam angles in the supine (SP plan) and prone (PR plan) positions. In the case of using multiple positions, the treatment plan was created with two angles for each of the supine and prone position (SP + PR plan). Dose evaluation for multiple positions was performed in two ways: by directly adding the values of the DVH parameters for each position treatment plan (DVH sum), and by calculating the DVH parameters from the accumulative dose distribution created using DIR (DIR sum). The D2cc and D6cc of the stomach and duodenum were recorded for each treatment plan and dosimetry method and compared. RESULTS: There were no significant differences among any of the treatment planning and dosimetry methods (p > 0.05). The DVH parameters for the stomach and duodenum were higher in the PR plan and SP plan, respectively, and DVH sum tended to be between the SP and PR plans. DVH sum and DIR sum, DVH sum tended to be higher for D2cc and DIR sum tended to be higher for D6cc. CONCLUSION: There were no significant differences in the GI dose, which suggests that treatment with a simple workflow performed in one position should be clinically acceptable. In CIRT, DIR-based dosimetry should be carefully considered because of the potential for increased uncertainty due to the steep dose distributions.


Assuntos
Radioterapia com Íons Pesados , Órgãos em Risco , Neoplasias Pancreáticas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia com Íons Pesados/métodos , Órgãos em Risco/efeitos da radiação , Radioterapia de Intensidade Modulada/métodos , Posicionamento do Paciente , Masculino , Feminino , Processamento de Imagem Assistida por Computador/métodos , Idoso , Pessoa de Meia-Idade , Prognóstico
3.
Gan To Kagaku Ryoho ; 50(13): 1959-1961, 2023 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-38303264

RESUMO

BACKGROUND: Carbon-ion radiotherapy(CIRT)has an advantage over conventional radiotherapy by its dose distribution and biological effect for locally advanced unresectable pancreatic cancer(UR-PC). Conversion surgery(CS)might be attempted for UR-PC with favorable response by chemotherapy and radiotherapy. CASE PRESENTATION: A 67-year-old female who have a history of distal gastrectomy. CT scan revealed locally advanced UR-PC with invasion to celiac artery, 60 mm in size. Systemic chemotherapy with gemcitabine and nab-paclitaxel was continued for 15 months, showing decrease of tumor markers and radiological shrinkage of the tumor. The patient was referred to our hospital for surgical consultation. Since there was no metastasis in staging laparoscopy, CIRT with gemcitabine was administered for 3 weeks. After completion of CIRT, distal pancreatectomy with celiac axis resection and total remnant gastrectomy for direct invasion of the tumor was performed as CS, resulting R0 resection. Her postoperative course was uneventful with 17 days of hospital stay. DISCUSSION: CS after CIRT was safely performed. Clinical trial of total neoadjuvant therapy with systemic chemotherapy, CIRT, followed by CS for locally advanced CIRT is ongoing in our hospital. CIRT could be an effective treatment in locally advanced UR-PC in the context of multi-modal treatment including CS.


Assuntos
Gencitabina , Neoplasias Pancreáticas , Humanos , Feminino , Idoso , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Pâncreas/patologia , Neoplasias Pancreáticas/tratamento farmacológico , Neoplasias Pancreáticas/cirurgia , Carbono/uso terapêutico
4.
BMC Med Inform Decis Mak ; 22(1): 111, 2022 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-35477440

RESUMO

BACKGROUND: Cancer treatment requires a multidisciplinary approach. Therefore, multidisciplinary team meetings (MDTMs) have been widely used to determine the direction of treatment. However, no standard provisions exist for conducting MDTMs, and recommendations discussed in MDTMs are sometimes not implemented. ​This study analyzed the indications for radiotherapy discussed and recommended at MDTMs, identified the rate of radiotherapy recommendations for patients that were not implemented, and clarified the reasons at a single academic center in Japan. METHODS: This was a cross-sectional study that analyzed the minutes and electronic medical records of cases discussed at MDTMs held between April 2012-March 2017 at Yamagata University Hospital. We categorized how radiotherapy was initially presented at MDTMs, determined the rate of radiotherapy recommendations made through MDTMs, analyzed whether treatment recommendations were subsequently implemented, and examined the causes of non-implementation. We performed a statistical analysis to assess some clinical factors (sex, age, number of multidisciplinary team meetings, and classification of planned treatment) associated with the non-implementation of radiotherapy recommendations from MDTMs. RESULTS: A total of 1813 cases were discussed at MDTMs, of which 71% (1293 cases) were presented with treatment plans, including radiotherapy. Further, 66% (1205 cases) were recommended for radiotherapy through the MDTMs. Recommendations from MDTMs were not implemented in 7% (142 cases). The most typical reason for non-implementation was the clinician's opinion (30%), followed by patient preferences (27%) and disease progression (20%). Change in cancer stage and improvement in symptoms were 12% and 4%, respectively. These ratios were similar each year. We could not find the factors associated with the non-implementation of radiotherapy recommendations from MDTMs. CONCLUSIONS: MDTMs had a significant effect on the recommendation of radiotherapy for each patient with a tumor. The primary reason for the non-implementation of decisions made at MDTMs was the opinion of clinicians and the patient's preference. These results were similar to previous studies. We need to establish a monitoring system where patients themselves can decide the treatments based on their choices while using the recommendations from MDTMs.


Assuntos
Instalações de Saúde , Equipe de Assistência ao Paciente , Estudos Transversais , Tomada de Decisões , Humanos , Japão
5.
Cancer Sci ; 112(9): 3598-3606, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34107139

RESUMO

There are no clinical reports of long-term follow-up after carbon-ion radiotherapy (CIRT) using a dose of 51.6 Gy (relative biological effectiveness [RBE]) in 12 fractions for localized prostate cancer, or of a comparison of clinical outcomes between passive and scanning beam irradiation. A total of 256 patients with localized prostate cancer who received CIRT at a dose of 51.6 Gy (RBE) in 12 fractions using two different beam delivery techniques (passive [n = 45] and scanning [n = 211]), and who were followed for more than 1 year, were analyzed. The biochemical relapse-free (bRF) rate was defined by the Phoenix definition, and the actuarial toxicity rates were evaluated using the Kaplan-Meier method. Of the 256 patients, 41 (16.0%), 111 (43.4%), and 104 (40.6%) were classified as low, intermediate, and high risk, respectively, after a median follow-up of 7.0 (range 1.1-10.4) years. Androgen deprivation therapy was performed in 212 patients (82.8%). The 5-year bRF rates of the low-, intermediate-, and high-risk patients were 95.1%, 90.9%, and 91.1%, respectively. The 5-year rates of grade 2 late gastrointestinal and genitourinary toxicities in all patients were 0.4% and 6.3%, respectively. No grade ≥3 toxicities were observed. There were no significant differences in the rates of bRF or grade 2 toxicities in patients who received passive irradiation versus scanning irradiation. Our long-term follow-up results showed that a CIRT regimen of 51.6 Gy (RBE) in 12 fractions for localized prostate cancer yielded a good therapeutic outcome and low toxicity rates irrespective of the beam delivery technique.


Assuntos
Antagonistas de Androgênios/uso terapêutico , Radioterapia com Íons Pesados/efeitos adversos , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/radioterapia , Radioterapia de Intensidade Modulada/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Fracionamento da Dose de Radiação , Seguimentos , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/epidemiologia , Neoplasias da Próstata/mortalidade , Estudos Retrospectivos , Taxa de Sobrevida
6.
J Appl Clin Med Phys ; 20(6): 53-59, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31054217

RESUMO

PURPOSE: We evaluated the setup accuracy of a three-degree-of-freedom fiducial marker (3DOF-FM)-based setup compared to a soft tissue (ST)-based setup in hypofractionated intensity-modulated radiotherapy (IMRT) for prostate cancer. MATERIALS AND METHODS: We analyzed the setup accuracy for 17 consecutive prostate cancer patients with three implanted FMs who underwent hypofractionated IMRT. The 3DOF-ST-based setup using cone-beam computed tomography (CT) was performed after a six DOF-bony structure (BS)-based setup using an ExacTrac x-ray system. The 3DOF-FM-based matching using the ExacTrac x-ray system was done during the BS- and ST-based setups. We determined the mean absolute differences and the correlation between the FM- and ST-based translational shifts relative to the BS-based setup position. The rotational mean shifts detected by the ExacTrac x-ray system were also evaluated. RESULTS: The mean differences in the anterior-posterior (AP), superior-inferior (SI), and left-right (LR) dimensions were 0.69, 0.0, and 0.30 mm, respectively. The Pearson correlation coefficients for both shifts were 0.92 for AP, 0.91 for SI, and 0.68 for LR. The percentages of shift agreements within 2 mm were 85% for AP, 93% for SI, and 99% for LR. The absolute values of rotational shifts were 0.1° for AP, 0.3°, and 1.2° for LR. CONCLUSIONS: The setup accuracy of the 3DOF-FM-based setup has the potential to be interchangeable with a ST-based setup. Our data are likely to be useful in clinical practice along with the popularization of the hypofractionated IMRT in prostate cancer.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Marcadores Fiduciais , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/metabolismo , Dosagem Radioterapêutica , Erros de Configuração em Radioterapia/prevenção & controle
7.
J Appl Clin Med Phys ; 16(5): 239­245, 2015 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699304

RESUMO

The purpose of this study was to test the superiority of a soft tissue-based setup using cone-beam computed tomography (CBCT) to a bony structure-based setup using the ExacTrac system in intensity-modulated radiotherapy (IMRT) for prostate cancer. We studied 20 patients with localized prostate cancer who received IMRT between November 2010 and February 2012. After the initial setup, the pelvic bony structure-based setup and ExacTrac system were applied. After that, CBCT and a soft tissue-based setup were used. A shift in the isocenter between the ExacTrac-based and CBCT-based setup was recorded in the anterior-posterior (AP), superior-inferior (SI), and left-right (LR) axes. The shift was considered an interfractional prostate shift. Post-treatment CBCT was also taken once a week to measure the intrafractional prostate shift, based on the coordinates of the isocenter between pre- and post-treatment CBCT. The planning target volume (PTV) margins were determined using van Herk's method. We measured the elapsed time required for soft tissue matching and the entire treatment time using CBCT. The means ± standard deviation (SD) of the inter- and intrafractional shifts were 0.9 ± 2.8 mm and -0.3 ± 1.4 mm in the AP, 0.9 ± 2.2 mm and -0.1 ± 1.2 mm in the SI, and 0.1 ± 0.7 mm and -0.1 ± 0.7 mm in the LR directions. The PTV margins in the cases of bony structure-based and soft tissue-based setups were 7.3 mm and 2.7 mm in the AP, 5.8 mm and 2.3 mm in the SI, and 1.9 mm and 1.2 mm in the LR directions. Even though the median elapsed time using CBCT was expanded in 5.9 min, the PTV margins were significantly reduced. We found the calculated PTV margins in the soft tissue-based setup using CBCT were small, and this arrangement was superior to the bony structure-based setup in prostate IMRT.


Assuntos
Osso e Ossos/efeitos da radiação , Braquiterapia , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Radioterapia Guiada por Imagem/métodos , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Prognóstico , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
8.
Jpn J Radiol ; 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38727960

RESUMO

PURPOSE: This study aimed to develop a user-friendly prediction formula for dose rate adjustment after initial 177Lu-Dotatate therapy from a prospective observational study of patients. MATERIALS AND METHODS: This study included consenting patients in a prospective observational study who underwent their first treatment in four cycles of 177Lu-Dotatate treatment at our hospital between January 2022 and February 2024. All patients received 7.4 GBq of 177Lu-Dotatate. The prediction formula was derived from the regression analysis of tumor-related factors and renal function. Creatinine clearance was estimated using the Cockcroft-Gault equation in this study for renal function. RESULTS: Among the 13 patients (seven males, six females, median age: 59 years), logarithmically transformed total tumor volume (cc) and maximum tumor diameter (mm) of primary tumors or metastases showed strong correlations (p < 0.001, R2 = 0.897). As such, the maximum tumor diameter was used as the tumor parameter in the prediction formula. Additionally, maximum tumor diameter and creatinine clearance showed strong (p < 0.001, R2 = 0.768) and moderate (p = 0.013, R2 = 445) correlations, respectively, with the ratio of the dose rate 5.5-h post-administration to the dose rate immediately post-administration (%) at 1 m from the body surface. The resulting formula, 51.4 + 0.360 × maximum tumor diameter (mm) - 0.212 × creatinine clearance (ml/min), demonstrated an extremely strong correlation (p < 0.001, R2 = 0.937). CONCLUSION: The present study showed that the maximum tumor diameter and renal function affected the declining the dose rate of patients surface after 177Lu-Dotatate, which can inform post-administration dose rate management and potentially facilitate outpatient treatment in Japan.

9.
Int J Part Ther ; 11: 100011, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38757079

RESUMO

Purpose: We performed computed tomography (CT)-stopping power ratio (SPR) calibration in a carbon-ion therapy facility and evaluated SPR estimation accuracy. Materials and Methods: A polybinary tissue model method was used for the calibration of CT numbers and SPR. As a verification by dose calculation, we created a virtual phantom to which the CT-SPR calibration table was applied. Then, SPR was calculated from the change in the range of the treatment planning beam when changing to 19 different CT numbers, and the accuracy of the treatment planning system (TPS) calculation of SPR values from the CT-SPR calibration table was validated. As a verification by measurement, 5 materials (water, milk, olive oil, ethanol, 40% K2HPO4) were placed in a container, and the SPR was obtained by measurement from the change in the range of the beam that passed through the materials. Results: The results of the dose calculations of the TPS showed that the results agreed within 1% for the lower CT numbers up to 1000 HU, but there was a difference of 3.0% in the higher CT number volume. The difference between the SPR calculated by TPS and the SPR caused by the difference in the energy of the incident particles agreed within 0.51%. The accuracy of SPR estimation was measured, and the error was within 2% for all materials tested. Conclusion: These results indicate that the SPR estimation errors are within the range of errors that can be expected in particle therapy. From commissioning and verification results, the CT-SPR calibration table obtained during this commissioning process is clinically applicable.

10.
Oncol Ther ; 10(2): 493-501, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35852785

RESUMO

INTRODUCTION: Although magnetic resonance imaging (MRI) is an important modality for the diagnosis of metastatic spinal cord compression (MSCC), there are only a few reports on MSCC findings and symptoms after radiotherapy. We aimed to reveal the factors related to ambulatory function after treatment, including the MRI findings, in a prospective observational study. METHODS: Patients with suspected MSCC who were treated with radiotherapy were included in this study. Orthopedic surgeons evaluated the neurological function according to the Frankel grade. All patients underwent spinal MRI, and the degree of spinal cord compression was assessed by a radiologist and a radiation oncologist using an MRI grading scale. One month after treatment, orthopedic surgeons reassessed the Frankel grade. Twenty-three patients who were evaluated 1 month after radiotherapy were included in the analysis. RESULTS: Before radiotherapy, 17 patients were ambulatory and six were unable to walk. Furthermore, 13 patients were diagnosed with grade 3 compression on MRI (spinal cord compression with no cerebrospinal fluid seen on axial T2-weighted imaging). Patients with grade 3 MSCC were significantly more likely to be non-ambulatory at 1 month. CONCLUSIONS: The MRI grading scale for MSCC may be a prognostic factor for ambulatory function after radiotherapy. MRI findings could aid in determining the indication for radiotherapy.

11.
J Radiat Res ; 62(4): 699-706, 2021 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-34059894

RESUMO

We aimed to predict the minimum distance between a tumor and the gastrointestinal (GI) tract that can satisfy the dose constraint by creating simulation plans with carbon-ion (C-ion) radiotherapy (RT) and photon RT for each case assuming insertion of virtual spacers of various thicknesses. We enrolled 55 patients with a pelvic tumor adjacent to the GI tract. Virtual spacers were defined as the overlap volume between the GI tract and the volume expanded 7-17 mm from the gross tumor volume (GTV). Simulation plans (70 Gy in 35 fractions for at least 95% of the planning target volume [PTV]) were created with the lowest possible dose to the GI tract under conditions that meet the dose constraints of the PTV. We defined the minimum thickness of virtual spacers meeting D2 cc of the GI tract <50 Gy as 'MTS'. Multiple regression was used with explanatory variables to develop a model to predict MTS. We discovered that MTSs were at most 9 mm and 13 mm for C-ion RT and photon RT plans, respectively. The volume of overlap between the GI tract and a virtual spacer of 14 mm in thickness (OV14)-PTV was found to be the most important explanatory variable in the MTS prediction equation for both C-ion and photon RT plans. Multiple R2 values for the regression model were 0.571 and 0.347 for C-ion RT and photon RT plans, respectively. In conclusion, regression equations were developed to predict MTS in C-ion RT and photon RT.


Assuntos
Simulação por Computador , Radioterapia com Íons Pesados , Neoplasias Pélvicas/radioterapia , Fótons , Relação Dose-Resposta à Radiação , Humanos , Dosagem Radioterapêutica
12.
Radiat Oncol ; 14(1): 207, 2019 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-31752932

RESUMO

PURPOSE: The purpose of this study was to compare carbon-ion (C-ion), proton and photon radiotherapy (RT) plans with regard to dose reduction of the gastrointestinal (GI) tract by using a greater omentum spacer (GO spacer). METHODS: We retrospectively retrieved data for ten patients who received the GO spacer as surgical spacer placement for abdominal and pelvic tumors. Simulation plans were created on pre-spacer Computed Tomography (CT) and post-spacer CT for C-ion RT, proton RT and photon RT to compare the dose of the GI tract. The plans were normalized so that at least 95% of the planning target volume (PTV) received 70 Gy (relative biological effectiveness equivalent) delivered in 35 fractions. All plans were created with the lowest possible dose to the GI tract under conditions that meet the dose constraints for the PTV and spinal cord (maximum dose < 45 Gy). The part of the GI tract to be evaluated was defined as that most adjacent to the PTV. C-ion RT plans and proton RT plans were calculated by a spot scanning technique, and photon RT plans were calculated employing by fixed-field intensity-modulated radiation therapy. RESULTS: D2 cc and V10-70 of the GI tract were significantly lower on post-spacer plans than on pre-spacer plans for all three RT modalities. Regarding post-spacer plans, D2 cc of the GI tract was significantly lower on C-ion RT plans and proton RT plans than on photon RT plans (C-ion vs photon p = 0.001, proton vs photon p = 0.002). However, there was no significant difference between C-ion RT plans and proton RT plans for D2 cc of the GI tract (C-ion vs proton p = 0.992). In the photon RT plan for one patient, D2 cc of the GI tract did not meet < 50 Gy. CONCLUSIONS: The GO spacer shows a significant dose reduction effect on the GI tract.


Assuntos
Neoplasias Abdominais/radioterapia , Radioterapia com Íons Pesados/métodos , Omento/efeitos da radiação , Neoplasias Pélvicas/radioterapia , Terapia com Prótons/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Abdominais/cirurgia , Simulação por Computador , Feminino , Trato Gastrointestinal/efeitos da radiação , Humanos , Masculino , Neoplasias Pélvicas/cirurgia , Fótons , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
13.
J Radiat Res ; 57(3): 280-7, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26983988

RESUMO

We investigated the outcomes of treatment for patients with localized prostate cancer (PCa) treated with 3D conformal radiation therapy (3D-CRT) followed by two-fraction high-dose-rate brachytherapy within a single day (2-fr.-HDR-BT/day) at a single institution. A total of 156 consecutive Asian males (median age, 67 years) were enrolled. To compare our findings with those of other studies, we analyzed our results using the D'Amico classification, assigning the patients to low- ( N =: 5; 3.2%), intermediate- ( N =: 36; 23.1%) and high-risk ( N =: 115; 73.7%) groups (Stage T3 PCa patients were classified as high-risk). One patient in the D'Amico low-risk group (20%), 13 intermediate-risk patients (36.1%) and 99 high-risk patients (86.1%) underwent androgen deprivation therapy. We administered a prescription dose of 39 Gy in 13 fractions of 3D-CRT combined with 18 Gy of HDR-BT in two 9-Gy fractions delivered within a single day. We did not distinguish between risk groups in determining the prescription dose. The median follow-up period was 38 months. Of the 156 patients, one died from primary disease and five died from other diseases. The 3-year overall survival (OS) rates were 100%, 100% and 93.7%, and the 3-year 'biochemical no evidence of disease (bNED)' rates were 100%, 100% and 96.9% for the D'Amico low-, intermediate- and high-risk groups, respectively. No patient developed ≥ Grade 3 early toxicity. The Grade 3 late genitourinary toxicity rate was 2.6%, and no ≥ Grade 3 late gastrointestinal toxicity occurred. The efficacy and safety of this study were satisfactory, and longer-term follow-up is necessary.


Assuntos
Braquiterapia/métodos , Fracionamento da Dose de Radiação , Neoplasias da Próstata/radioterapia , Idoso , Braquiterapia/efeitos adversos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Resultado do Tratamento
15.
Radiat Oncol ; 10: 31, 2015 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-25636830

RESUMO

BACKGROUND: To evaluate the risks and benefits of endoscopic submucosal dissection (ESD) in addition to chemoradiotherapy (CRT) for the treatment of superficial esophageal squamous cell carcinoma (SESCC). METHODS AND MATERIALS: We retrospectively reviewed the treatment outcomes of 47 patients with SESCC treated between October 2000 and December 2011. Sixteen patients with invasion into the submucosal layer (T1b) or the muscularis mucosa (m3) with positive vascular invasion were treated with CRT after ESD (ESD-CRT group). The lymph node area was irradiated to a total dose of 40-44 Gy and a boost radiation was administered if PET-positive lymph nodes or positive margins were observed. The remaining 31 patients received definitive CRT only (dCRT group). RESULTS: The radiation field was significantly larger in the ESD-CRT group; the "long T" was used in 11 patients (35.4%) in the dCRT group and 15 (93.7%) in the ESD-CRT group (p = 0.0001). The total radiation dose was smaller in the ESD-CRT group; 40 Gy was used in 10 patients (62.5%) in the ESD-CRT group and all but one patient in the dCRT group received ≥60 Gy (p = 0.00001). The 3-year overall survival rates in the dCRT and ESD-CRT groups were 63.2% and 90.0% respectively (p = 0.118). Recurrence developed in nine patients (29.0%) in the dCRT group and one (6.3%) in the ESD-CRT group. Local recurrence was observed in six patients (19%) in the dCRT group and none in the ESD-CRT-group (p = 0.029). Pericardial effusion (≥Grade 3) occurred in three patients (9.7%) in the dCRT group and none in the ESD-CRT group. CONCLUSIONS: ESD followed by CRT is an effective and safe approach for SESCC at m3 or T1b. This combination of ESD and CRT improves the local control rate, and it could decrease the number of cardiac toxicities due to a radiation-dose reduction relative to CRT alone.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Carcinoma de Células Escamosas/terapia , Neoplasias Esofágicas/terapia , Esofagectomia , Esofagoscopia/métodos , Mucosa/cirurgia , Recidiva Local de Neoplasia/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas/mortalidade , Carcinoma de Células Escamosas/patologia , Terapia Combinada , Dissecação , Neoplasias Esofágicas/mortalidade , Neoplasias Esofágicas/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/mortalidade , Recidiva Local de Neoplasia/patologia , Estadiamento de Neoplasias , Prognóstico , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada , Estudos Retrospectivos , Taxa de Sobrevida
16.
Dev Dyn ; 230(1): 107-13, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15108314

RESUMO

Mitf (gene for microphthalmia-associated transcription factor) encodes a transcription factor of the basic/helix-loop-helix/leucine-zipper family and is a key regulator during the development of two different types of melanin-producing cell lineages, namely neural crest-derived melanocytes/melanophores, and the retinal pigment epithelium (RPE) differentiated from the outer layer of the eye cup. Mitf-deficient mice show a lack of melanocytes and small eyes caused by abnormal RPE development. An interesting feature of Mitf is the existence of multiple isoforms with different amino termini and their functions in the development of these melanin-producing pigment cells. In this study, we isolated two Mitf homologues (XlMitfalpha and XlMitfbeta) and their isoforms from Xenopus laevis. Alignment analysis of the amino acid sequences of the N-termini suggests that these isoforms are homologues of mouse Mitf-M (expressed specifically in the melanocyte lineage) and Mitf-A (strongly expressed in the RPE, although this expression is ubiquitous). In Xenopus, XlMitfalpha is strongly expressed in the melanophore lineage (especially in premigratory melanoblasts) and the presumptive RPE and the epiphysis, in which melanin-producing cells differentiate in some vertebrates. Conservation of the Mitf isoforms expected to possess specific functions in the development of melanin-producing cells and of the expressions in such cell types in Xenopus suggest that XlMitf plays a central role in the development of melanin-producing cell lineages, and that, as in mice and humans, most of the signaling molecules or transcription factors implicated genetically in the development of melanin-producing cell lineages affect either Mitf expression or its function (Goding [2000] Genes Dev. 14:1712-1728).


Assuntos
Proteínas de Ligação a DNA/biossíntese , Proteínas de Ligação a DNA/fisiologia , Regulação da Expressão Gênica no Desenvolvimento , Fatores de Transcrição/biossíntese , Fatores de Transcrição/fisiologia , Sequência de Aminoácidos , Animais , Diferenciação Celular , Linhagem da Célula , DNA Complementar/metabolismo , Células Epiteliais/citologia , Olho/embriologia , Hibridização In Situ , Melaninas/metabolismo , Melanócitos/metabolismo , Melanóforos/metabolismo , Camundongos , Fator de Transcrição Associado à Microftalmia , Dados de Sequência Molecular , Crista Neural/embriologia , Epitélio Pigmentado Ocular/embriologia , Epitélio Pigmentado Ocular/metabolismo , Isoformas de Proteínas , Estrutura Terciária de Proteína , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Homologia de Sequência de Aminoácidos , Xenopus laevis
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA