Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Vet Radiol Ultrasound ; 63(2): 197-200, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35050530

RESUMO

Intracranial abscessation is a life-threatening condition in dogs and cats, and rapid diagnosis is important for prognosis and treatment planning. The aims of this retrospective, single-center, case series study were to describe clinical and MRI diffusion-weighted imaging characteristics in three dogs and three cats with presumed or confirmed intracranial abscessation. All lesions appeared hyperintense on b1000 trace diffusion-weighted images, hypointense on apparent diffusion coefficient (ADC) map, with mean ADC values ranging from 0.37 to 1.24 × 10-3  mm2 /s. The majority (5/6) of the obtained mean ADC values were low (<1.10 × 10-3  mm2 /s), as previously reported in the human literature.


Assuntos
Doenças do Gato , Doenças do Cão , Animais , Doenças do Gato/diagnóstico por imagem , Gatos , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/veterinária , Doenças do Cão/diagnóstico por imagem , Cães , Imageamento por Ressonância Magnética , Estudos Retrospectivos
2.
Can J Vet Res ; 84(1): 24-32, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31949326

RESUMO

The objective of this study was to document tidal variations in tracheal height during normal respiration in 19 healthy adult (> 1 y old) small-breed dogs (< 10 kg) using fluoroscopy and radiography. Each dog underwent tracheal fluoroscopic examination on inspiration and expiration while in a standing position (F-S) and in right lateral recumbency (F-RL), followed by radiographic projections obtained in right lateral recumbency. The percent variation in tracheal height during maximal inspiration and expiration was determined at 3 different locations [cervical region (CR), thoracic inlet (TI), and intrathoracic (IT) region]. When all imaging procedures and sites of measurement were considered, tracheal height varied during physiologic inspiration and expiration from 0% to 21.1%, with a mean of 4.5%. The mean percent variation in tracheal height was not significantly different among imaging modalities (F-S versus F-RL versus radiography) (P = 0.16) or measurement sites (CR versus TI versus IT) (P = 0.89). The body condition score (BCS) (P = 0.96), age (P = 0.95), and breed (P = 0.19) did not significantly influence the mean percent variation in tracheal height. The average variation in tracheal height during maximal physiological inspiration and expiration is small (< 6%) in most healthy adult small-breed dogs as assessed by fluoroscopy and radiography, although tracheal height may vary by as much as 21.1% in some healthy individuals. Inspiratory and expiratory radiographs acquired in right lateral recumbency provide an accurate assessment of tracheal height as an alternative to fluoroscopy.


L'objectif de la présente étude était de documenter les variations de la hauteur de la trachée durant la respiration normale chez 19 chiens adulte en santé (> 1 an) de petites races (< 10 kg) à l'aide de la fluoroscopie et de la radiographie. Chaque chien a été soumis à un examen fluoroscopique de la trachée lors de l'inspiration et de l'expiration alors qu'il était en position debout (F-S) et en décubitus latéral droit (F-RL), suivi d'images radiographiques obtenues en décubitus latéral droit. Le pourcentage de variation de la hauteur de la trachée durant l'inspiration et l'expiration maximales fut déterminé à trois endroits différents [région cervicale (CR), l'entrée thoracique (TI), et la région intrathoracique (IT)]. Lorsque toutes les procédures d'imagerie et les sites de mesure étaient considérés, la hauteur de la trachée variait durant l'inspiration et l'expiration physiologique de 0 % à 21,1 %, avec une moyenne de 4,5 %. Le pourcentage de variation moyen de la hauteur de la trachée n'était pas significativement différent parmi les différentes modalités d'imagerie (F-S versus F-RL versus radiographie) (P = 0,16) ou les sites de mesure (CR versus TI versus IT) (P = 0,89). Le score de condition corporelle (BCS) (P = 0,96), l'âge (P = 0,95), et la race (P = 0,19) n'influençaient pas significativement le pourcentage de variation moyen de la hauteur de la trachée. La variation moyenne de la hauteur de la trachée durant l'inspiration et l'expiration physiologique maximale est petite (< 6 %) chez la plupart des chiens adultes de petites races en santé telle qu'évalué par fluoroscopie et radiographie, bien que la hauteur de la trachée puisse varier jusqu'à 21,1 % chez certains individus en santé. Les radiographies à l'inspiration et à l'expiration obtenues en décubitus latéral droit fournissent une évaluation précise de la hauteur de la trachée comme alternative à la fluoroscopie.(Traduit par Docteur Serge Messier).


Assuntos
Cães/anatomia & histologia , Expiração/fisiologia , Inalação/fisiologia , Traqueia/anatomia & histologia , Traqueia/diagnóstico por imagem , Animais , Tamanho Corporal , Cães/classificação , Cães/fisiologia , Feminino , Fluoroscopia/veterinária , Masculino , Radiografia Torácica/veterinária , Traqueia/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA