Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Mass Spectrom Rev ; 42(5): 1927-1964, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35822576

RESUMO

Mass spectrometry imaging (MSI) has become a widespread analytical technique to perform nonlabeled spatial molecular identification. The Achilles' heel of MSI is the annotation and identification of molecular species due to intrinsic limitations of the technique (lack of chromatographic separation and the difficulty to apply tandem MS). Successful strategies to perform annotation and identification combine extra analytical steps, like using orthogonal analytical techniques to identify compounds; with algorithms that integrate the spectral and spatial information. In this review, we discuss different experimental strategies and bioinformatics tools to annotate and identify compounds in MSI experiments. We target strategies and tools for small molecule applications, such as lipidomics and metabolomics. First, we explain how sample preparation and the acquisition process influences annotation and identification, from sample preservation to the use of orthogonal techniques. Then, we review twelve software tools for annotation and identification in MSI. Finally, we offer perspectives on two current needs of the MSI community: the adaptation of guidelines for communicating confidence levels in identifications; and the creation of a standard format to store and exchange annotations and identifications in MSI.

2.
BMC Bioinformatics ; 21(1): 448, 2020 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-33036551

RESUMO

BACKGROUND: Multimodal imaging that combines mass spectrometry imaging (MSI) with Raman imaging is a rapidly developing multidisciplinary analytical method used by a growing number of research groups. Computational tools that can visualize and aid the analysis of datasets by both techniques are in demand. RESULTS: Raman2imzML was developed as an open-source converter that transforms Raman imaging data into imzML, a standardized common data format created and adopted by the mass spectrometry community. We successfully converted Raman datasets to imzML and visualized Raman images using open-source software designed for MSI applications. CONCLUSION: Raman2imzML enables both MSI and Raman images to be visualized using the same file format and the same software for a straightforward exploratory imaging analysis.


Assuntos
Processamento de Imagem Assistida por Computador/normas , Espectrometria de Massas , Imagem Molecular , Análise Espectral Raman , Padrões de Referência
3.
J Cheminform ; 15(1): 80, 2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37715285

RESUMO

Matrix-Assisted Laser Desorption Ionization Mass Spectrometry Imaging (MALDI-MSI) spatially resolves the chemical composition of tissues. Lipids are of particular interest, as they influence important biological processes in health and disease. However, the identification of lipids in MALDI-MSI remains a challenge due to the lack of chromatographic separation or untargeted tandem mass spectrometry. Recent studies have proposed the use of MALDI in-source fragmentation to infer structural information and aid identification. Here we present rMSIfragment, an open-source R package that exploits known adducts and fragmentation pathways to confidently annotate lipids in MALDI-MSI. The annotations are ranked using a novel score that demonstrates an area under the curve of 0.7 in ROC analyses using HPLC-MS and Target-Decoy validations. rMSIfragment applies to multiple MALDI-MSI sample types and experimental setups. Finally, we demonstrate that overlooking in-source fragments increases the number of incorrect annotations. Annotation workflows should consider in-source fragmentation tools such as rMSIfragment to increase annotation confidence and reduce the number of false positives.

4.
Anal Chim Acta ; 1171: 338669, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34112434

RESUMO

Mass spectrometry imaging (MSI) consist of spatially located spectra with thousands of peaks. Only a fraction of these peaks corresponds to unique monoisotopic peaks, as mass spectra include isotopes, adducts and fragments of compounds. Current peak annotation solutions depend on matching MS features to compounds libraries. We present rMSIannotation, a peak annotation algorithm to annotate carbon isotopes and adducts in metabolomics and lipidomics imaging mass spectrometry datasets without using supporting libraries. rMSIannotation measures and evaluates the intensity ratio between carbon isotopic peaks and models their distribution across the m/z axis of the compounds in the Human Metabolome Database. Monoisotopic peak selection is based on the isotopic likelihood score (ILS) made of three components: image morphology correlation, validation of isotopic intensity ratios, and peak centroid mass deviation. rMSIannotation proposes pairs of peaks that can be adducts based on three scores: isotopic pattern coherence, image correlation and mass error. We validated rMSIannotation with three MALDI-MSI datasets which were manually annotated by experts, and compared the annotations obtained with rMSIannotation and with the METASPACE annotation platform. rMSIannotation replicated more than 90% of the manual annotation reported in FT-ICR datasets and expanded the list of annotated compounds with additional monoisotopic peaks and neutral masses. Finally, we evaluated isotopic peak annotation as a data reduction method for MSI by comparing the results of PCA and k-means segmentation before and after removing non-monoisotopic peaks. The results show that monoisotopic peaks retain most of the biologic variance in the dataset.

5.
J Cheminform ; 12(1): 45, 2020 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-33431000

RESUMO

Mass spectrometry imaging (MSI) has become a mature, widespread analytical technique to perform non-targeted spatial metabolomics. However, the compounds used to promote desorption and ionization of the analyte during acquisition cause spectral interferences in the low mass range that hinder downstream data processing in metabolomics applications. Thus, it is advisable to annotate and remove matrix-related peaks to reduce the number of redundant and non-biologically-relevant variables in the dataset. We have developed rMSIcleanup, an open-source R package to annotate and remove signals from the matrix, according to the matrix chemical composition and the spatial distribution of its ions. To validate the annotation method, rMSIcleanup was challenged with several images acquired using silver-assisted laser desorption ionization MSI (AgLDI MSI). The algorithm was able to correctly classify m/z signals related to silver clusters. Visual exploration of the data using Principal Component Analysis (PCA) demonstrated that annotation and removal of matrix-related signals improved spectral data post-processing. The results highlight the need for including matrix-related peak annotation tools such as rMSIcleanup in MSI workflows.

6.
Metabolites ; 9(8)2019 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-31382415

RESUMO

Many MALDI-MS imaging experiments make a case versus control studies of different tissue regions in order to highlight significant compounds affected by the variables of study. This is a challenge because the tissue samples to be compared come from different biological entities, and therefore they exhibit high variability. Moreover, the statistical tests available cannot properly compare ion concentrations in two regions of interest (ROIs) within or between images. The high correlation between the ion concentrations due to the existence of different morphological regions in the tissue means that the common statistical tests used in metabolomics experiments cannot be applied. Another difficulty with the reliability of statistical tests is the elevated number of undetected MS ions in a high percentage of pixels. In this study, we report a procedure for discovering the most important ions in the comparison of a pair of ROIs within or between tissue sections. These ROIs were identified by an unsupervised segmentation process, using the popular k-means algorithm. Our ion filtering algorithm aims to find the up or down-regulated ions between two ROIs by using a combination of three parameters: (a) the percentage of pixels in which a particular ion is not detected, (b) the Mann-Whitney U ion concentration test, and (c) the ion concentration fold-change. The undetected MS signals (null peaks) are discarded from the histogram before the calculation of (b) and (c) parameters. With this methodology, we found the important ions between the different segments of a mouse brain tissue sagittal section and determined some lipid compounds (mainly triacylglycerols and phosphatidylcholines) in the liver of mice exposed to thirdhand smoke.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA