J Appl Clin Med Phys ; 22(11): 185-195, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34697869

RESUMO

PURPOSE: Research productivity metrics are important for decisions regarding hiring, retention, and promotion in academic medicine, and these metrics can vary widely among different disciplines. This article examines productivity metrics for radiation therapy physicists (RTP) in the United States. METHODS AND MATERIALS: Database searches were performed for RTP faculty at US institutions that have RTP residencies accredited by the Commission on Accreditation of Medical Physics Education Programs (CAMPEP). Demographics, academic rank, number of publications, academic career length, Hirsch index (h-index), m-quotient, and history of National Institutes of Health (NIH) funding as a principal investigator (PI) were collected for each RTP. Logistic regression was performed to determine the probability of academic rank as a function of h-index and m-quotient. Statistical tests used included the Wilcoxon ranked sum test and the Pearson χ2 test. RESULTS: A total of 1038 faculty and staff were identified at 78 institutions with CAMPEP-accredited residencies. The average RTP academic career duration is 13.5 years, with 46.7 total publications, h-index of 10.7, and m-quotient of 0.66. Additionally, 10.5% of RTP have a history of NIH funding as a PI. Large disparities were found in academic productivity of doctoral-prepared physicists compared to those with a terminal master's degree. For differences in junior and senior faculty, statistical tests yielded significance in career duration, number of publications, h-index, and m-quotient. Gender disparities were identified in the overall distribution of RTP consistent with the membership of the American Association of Physicists in Medicine. Further gender disparities were found in the number of doctoral-prepared RTP and physicists in senior faculty roles. CONCLUSIONS: This manuscript provides objective benchmark data regarding research productivity of academic RTP. These data may be of interest to faculty preparing for promotion, and also to institutional leadership.


Assuntos
Pesquisa Biomédica , Internato e Residência , Eficiência , Docentes , Humanos , National Institutes of Health (U.S.) , Física , Estados Unidos
2.
J Appl Clin Med Phys ; 22(5): 89-96, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33783960

RESUMO

PURPOSE: The purpose of this study was to evaluate the performance of three common deformable image registration (DIR) packages across algorithms and institutions. METHODS AND MATERIALS: The Deformable Image Registration Evaluation Project (DIREP) provides ten virtual phantoms derived from computed tomography (CT) datasets of head-and-neck cancer patients over a single treatment course. Using the DIREP phantoms, DIR results from 35 institutions were submitted using either Velocity, MIM, or Eclipse. Submitted deformation vector fields (DVFs) were compared to ground-truth DVFs to calculate target registration error (TRE) for six regions of interest (ROIs). Statistical analysis was performed to determine the variability between each DIR software package and the variability of users within each algorithm. RESULTS: Overall mean TRE was 2.04 ± 0.35 mm for Velocity, 1.10 ± 0.29 mm for MIM, and 2.35 ± 0.15 mm for Eclipse. The MIM mean TRE was significantly different than both Velocity and Eclipse for all ROIs. Velocity and Eclipse mean TREs were not significantly different except for when evaluating the registration of the cord or mandible. Significant differences between institutions were found for the MIM and Velocity platforms. However, these differences could be explained by variations in Velocity DIR parameters and MIM software versions. CONCLUSIONS: Average TRE was shown to be <3 mm for all three software platforms. However, maximum errors could be larger than 2 cm indicating that care should be exercised when using DIR. While MIM performed statistically better than the other packages, all evaluated algorithms had an average TRE better than the largest voxel dimension. For the phantoms studied here, significant differences between algorithm users were minimal suggesting that the algorithm used may have more impact on DIR accuracy than the particular registration technique employed. A significant difference in TRE was discovered between MIM versions showing that DIR QA should be performed after software upgrades as recommended by TG-132.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Cabeça , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
3.
J Appl Clin Med Phys ; 21(12): 178-187, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33226709

RESUMO

PURPOSE: Real-time magnetic resonance guided radiation therapy (MRgRT) uses 2D cine imaging for target tracking. This work evaluates the percent image uniformity (PIU) and spatial integrity of cine images in the presence of multileaf collimator (MLC) and gantry motion in order to simulate sliding window and volumetric modulated arc therapy (VMAT) conditions. METHODS: Percent image uniformity and spatial integrity of cine images were measured (1) during MLC motion, (2) as a function of static gantry position, and (3) during gantry rotation. PIU was calculated according to the ACR MRI Quality Control Manual. Spatial integrity was evaluated by measuring the geometric distortion of 16 measured marker positions (10 cm or 15.225 cm from isocenter). RESULTS: The PIU of cine images did not vary by more than 1% from static linac conditions during MLC motion and did not vary by more than 3% during gantry rotation. Banding artifacts were present during gantry rotation. The geometric distortion in the cine images was less than 0.88 mm for all points measured throughout MLC motion. For all static gantry positions, the geometric distortion was less than 0.88 mm at 10 cm from isocenter and less than 1.4 mm at 15.225 cm from isocenter. During gantry rotation, the geometric distortion remained less than 0.92 mm at 10 cm from isocenter and less than 1.60 mm at 15.225 cm from isocenter. CONCLUSION: During MLC motion, cine images maintained adequate PIU, and the geometric distortion of points within 15.225 cm from isocenter was less than the 1 mm threshold necessary for real-time target tracking and gating. During gantry rotation, PIU was negatively affected by banding artifacts, and spatial integrity was only maintained within 10 cm from isocenter. Future work should investigate the effects imaging artifacts have on real-time target tracking during MRgRT.


Assuntos
Aceleradores de Partículas , Radioterapia de Intensidade Modulada , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Controle de Qualidade
4.
J Appl Clin Med Phys ; 19(3): 149-158, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29682879

RESUMO

PURPOSE: To describe the commissioning of AIRO mobile CT system (AIRO) for adaptive proton therapy on a compact double scattering proton therapy system. METHODS: A Gammex phantom was scanned with varying plug patterns, table heights, and mAs on a CT simulator (CT Sim) and on the AIRO. AIRO-specific CT-stopping power ratio (SPR) curves were created with a commonly used stoichiometric method using the Gammex phantom. A RANDO anthropomorphic thorax, pelvis, and head phantom, and a CIRS thorax and head phantom were scanned on the CT Sim and AIRO. Clinically realistic treatment plans and nonclinical plans were generated on the CT Sim images and subsequently copied onto the AIRO CT scans for dose recalculation and comparison for various AIRO SPR curves. Gamma analysis was used to evaluate dosimetric deviation between both plans. RESULTS: AIRO CT values skewed toward solid water when plugs were scanned surrounded by other plugs in phantom. Low-density materials demonstrated largest differences. Dose calculated on AIRO CT scans with stoichiometric-based SPR curves produced over-ranged proton beams when large volumes of low-density material were in the path of the beam. To create equivalent dose distributions on both data sets, the AIRO SPR curve's low-density data points were iteratively adjusted to yield better proton beam range agreement based on isodose lines. Comparison of the stoichiometric-based AIRO SPR curve and the "dose-adjusted" SPR curve showed slight improvement on gamma analysis between the treatment plan and the AIRO plan for single-field plans at the 1%, 1 mm level, but did not affect clinical plans indicating that HU number differences between the CT Sim and AIRO did not affect dose calculations for robust clinical beam arrangements. CONCLUSION: Based on this study, we believe the AIRO can be used offline for adaptive proton therapy on a compact double scattering proton therapy system.


Assuntos
Algoritmos , Cabeça/diagnóstico por imagem , Imagens de Fantasmas , Terapia com Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/instrumentação , Humanos , Processamento de Imagem Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos
5.
J Appl Clin Med Phys ; 18(3): 130-136, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28436155

RESUMO

PURPOSE: The purpose of this study was to characterize the Mobius AIRO Mobile CT System for localization and image-guided proton therapy. This is the first known application of the AIRO for proton therapy. METHODS: Five CT images of a Catphan® 504 phantom were acquired on the AIRO Mobile CT System, Varian EDGE radiosurgery system cone beam CT (CBCT), Philips Brilliance Big Bore 16 slice CT simulator, and Siemens SOMATOM Definition AS 20 slice CT simulator. DoseLAB software v.6.6 was utilized for image quality analysis. Modulation transfer function, scaling discrepancy, geometric distortion, spatial resolution, overall uniformity, minimum uniformity, contrast, high CNR, and maximum HU deviation were acquired. Low CNR was acquired manually using the CTP515 module. Localization accuracy and CT Dose Index were measured and compared to reported values on each imaging device. For treatment delivery systems (Edge and Mevion), the localization accuracy of the 3D imaging systems were compared to 2D imaging systems on each system. RESULTS: The AIRO spatial resolution was 0.21 lp mm-1 compared with 0.40 lp mm-1 for the Philips CT Simulator, 0.37 lp mm-1 for the Edge CBCT, and 0.35 lp mm-1 for the Siemens CT Simulator. AIRO/Siemens and AIRO/Philips differences exceeded 100% for scaling discrepancy (191.2% and 145.8%). The AIRO exhibited higher dose (>27 mGy) than the Philips CT Simulator. Localization accuracy (based on the MIMI phantom) was 0.6° and 0.5 mm. Localization accuracy (based on Stereophan) demonstrated maximum AIRO-kV/kV shift differences of 0.1 mm in the x-direction, 0.1 mm in the y-direction, and 0.2 mm in the z-direction. CONCLUSIONS: The localization accuracy of AIRO was determined to be within 0.6° and 0.5 mm despite its slightly lower image quality overall compared to other CT imaging systems at our institution. Based on our study, the Mobile AIRO CT system can be utilized accurately and reliably for image-guided proton therapy.


Assuntos
Terapia com Prótons/instrumentação , Radiocirurgia/instrumentação , Radioterapia Guiada por Imagem/instrumentação , Tomografia Computadorizada por Raios X , Tomografia Computadorizada de Feixe Cônico , Desenho de Equipamento , Humanos , Imagens de Fantasmas , Terapia com Prótons/métodos , Radiocirurgia/métodos , Radioterapia Guiada por Imagem/métodos
6.
J Appl Clin Med Phys ; 17(3): 25-40, 2016 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-27167256

RESUMO

Benchmarking is a process in which standardized tests are used to assess system performance. The data produced in the process are important for comparative purposes, particularly when considering the implementation and quality assurance of DIR algorithms. In this work, five commercial DIR algorithms (MIM, Velocity, RayStation, Pinnacle, and Eclipse) were benchmarked using a set of 10 virtual phantoms. The phantoms were previously developed based on CT data collected from real head and neck patients. Each phantom includes a start of treatment CT dataset, an end of treatment CT dataset, and the ground-truth deformation vector field (DVF) which links them together. These virtual phantoms were imported into the commercial systems and registered through a deformable process. The resulting DVFs were compared to the ground-truth DVF to determine the target registration error (TRE) at every voxel within the image set. Real treatment plans were also recalculated on each end of treatment CT dataset and the dose transferred according to both the ground-truth and test DVFs. Dosimetric changes were assessed, and TRE was correlated with changes in the DVH of individual structures. In the first part of the study, results show mean TRE on the order of 0.5 mm to 3 mm for all phan-toms and ROIs. In certain instances, however, misregistrations were encountered which produced mean and max errors up to 6.8 mm and 22 mm, respectively. In the second part of the study, dosimetric error was found to be strongly correlated with TRE in the brainstem, but weakly correlated with TRE in the spinal cord. Several interesting cases were assessed which highlight the interplay between the direction and magnitude of TRE and the dose distribution, including the slope of dosimetric gradients and the distance to critical structures. This information can be used to help clinicians better implement and test their algorithms, and also understand the strengths and weaknesses of a dose adaptive approach.


Assuntos
Algoritmos , Neoplasias de Cabeça e Pescoço/patologia , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Benchmarking , Feminino , Humanos , Masculino , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X
7.
Med Dosim ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38849262

RESUMO

Bolus electron conformal therapy (BECT) in the treatment of cancers of the head and neck is often limited by an inability to reduce dosimetric hot spots resulting from surface irregularity or tissue heterogeneity. We examined the potential benefits of using intensity modulation for electron therapy (IM-BECT) to reduce hotspots in patients undergoing electron beam therapy for superficial cancers of the head and neck (HN). Twenty patients with HN cancer previously treated with BECT were identified. Each case included the treatment targets and a primary organ at risk (OAR) that were defined by the radiation oncologist. A target +2 cm rind structure was created for analysis of the dose deposition in areas surrounding the target volume as a measure of conformality. Each patient plan was transferred into the novel IM-BECT planning software and each case was recomputed as per the original parameters. Next, each case was replanned with the inclusion of intensity modulation, as well as a new custom conformal bolus that was redesigned for optimized range compensation when paired with an intensity modulator. The plans were then normalized to prescription dose and compared for target coverage/dose and OAR dose. For patients who had a hotspot of 125% or greater, the hotspot was on average reduced by 13.1% with IM-BECT. For IM-BECT, the average primary OAR means dose and target+2cm rind mean dose increased slightly by 10.6% and 6.4%, respectively (primary OAR mean [p = 0.0001], and Target+2cm rind mean [p = 0.0001], paired t-test). IM-BECT is an effective method of reducing hotspots in patients with superficial HN cancer. Improvements came at the expense of slight increases in dose to the underlying tissues. This retrospective planning study represents the first example of IM-BECT to actual HN patient cases. Expanding the role of IM-BECT in other disease sites could potentially compared to conventional BECT.

8.
Radiother Oncol ; 191: 110064, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38135187

RESUMO

BACKGROUND AND PURPOSE: Radiation dose escalation may improve local control (LC) and overall survival (OS) in select pancreatic ductal adenocarcinoma (PDAC) patients. We prospectively evaluated the safety and efficacy of ablative stereotactic magnetic resonance (MR)-guided adaptive radiation therapy (SMART) for borderline resectable (BRPC) and locally advanced pancreas cancer (LAPC). The primary endpoint of acute grade ≥ 3 gastrointestinal (GI) toxicity definitely related to SMART was previously published with median follow-up (FU) 8.8 months from SMART. We now present more mature outcomes including OS and late toxicity. MATERIALS AND METHODS: This prospective, multi-center, single-arm open-label phase 2 trial (NCT03621644) enrolled 136 patients (LAPC 56.6 %; BRPC 43.4 %) after ≥ 3 months of any chemotherapy without distant progression and CA19-9 ≤ 500 U/mL. SMART was delivered on a 0.35 T MR-guided system prescribed to 50 Gy in 5 fractions (biologically effective dose10 [BED10] = 100 Gy). Elective coverage was optional. Surgery and chemotherapy were permitted after SMART. RESULTS: Mean age was 65.7 years (range, 36-85), induction FOLFIRINOX was common (81.7 %), most received elective coverage (57.4 %), and 34.6 % had surgery after SMART. Median FU was 22.9 months from diagnosis and 14.2 months from SMART, respectively. 2-year OS from diagnosis and SMART were 53.6 % and 40.5 %, respectively. Late grade ≥ 3 toxicity definitely, probably, or possibly attributed to SMART were observed in 0 %, 4.6 %, and 11.5 % patients, respectively. CONCLUSIONS: Long-term outcomes from the phase 2 SMART trial demonstrate encouraging OS and limited severe toxicity. Additional prospective evaluation of this novel strategy is warranted.


Assuntos
Neoplasias Pancreáticas , Radiocirurgia , Humanos , Idoso , Neoplasias Pancreáticas/patologia , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Planejamento da Radioterapia Assistida por Computador , Radiocirurgia/efeitos adversos
9.
Pract Radiat Oncol ; 13(1): e3-e6, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35944807

RESUMO

 : Magnetic resonance image guided adaptive radiation therapy (MRgART) represents a significant improvement in our ability to deliver therapeutic radiation. However, for the process of MRgART to be carried out safely and efficiently, the covering radiation oncologist must be aware of all aspects of a patient's case, because they will be required to recontour and replan the patient before each treatment. In this report, we will demonstrate our initial experience with a video sign-out process to convey the detailed level of information required for the covering physician to treat patients safely and effectively with MRgART. We then describe our optimized video sign-out process to allow for other centers to adopt a similar approach.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Humanos , Fluxo de Trabalho , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Radioterapia Guiada por Imagem/métodos
10.
Int J Radiat Oncol Biol Phys ; 117(4): 799-808, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37210048

RESUMO

PURPOSE: Magnetic resonance (MR) image guidance may facilitate safe ultrahypofractionated radiation dose escalation for inoperable pancreatic ductal adenocarcinoma. We conducted a prospective study evaluating the safety of 5-fraction Stereotactic MR-guided on-table Adaptive Radiation Therapy (SMART) for locally advanced (LAPC) and borderline resectable pancreatic cancer (BRPC). METHODS AND MATERIALS: Patients with LAPC or BRPC were eligible for this multi-institutional, single-arm, phase 2 trial after ≥3 months of systemic therapy without evidence of distant progression. Fifty gray in 5 fractions was prescribed on a 0.35T MR-guided radiation delivery system. The primary endpoint was acute grade ≥3 gastrointestinal (GI) toxicity definitely attributed to SMART. RESULTS: One hundred thirty-six patients (LAPC 56.6%, BRPC 43.4%) were enrolled between January 2019 and January 2022. Mean age was 65.7 (36-85) years. Head of pancreas lesions were most common (66.9%). Induction chemotherapy mostly consisted of (modified)FOLFIRINOX (65.4%) or gemcitabine/nab-paclitaxel (16.9%). Mean CA19-9 after induction chemotherapy and before SMART was 71.7 U/mL (0-468). On-table adaptive replanning was performed for 93.1% of all delivered fractions. Median follow-up from diagnosis and SMART was 16.4 and 8.8 months, respectively. The incidence of acute grade ≥3 GI toxicity possibly or probably attributed to SMART was 8.8%, including 2 postoperative deaths that were possibly related to SMART in patients who had surgery. There was no acute grade ≥3 GI toxicity definitely related to SMART. One-year overall survival from SMART was 65.0%. CONCLUSIONS: The primary endpoint of this study was met with no acute grade ≥3 GI toxicity definitely attributed to ablative 5-fraction SMART. Although it is unclear whether SMART contributed to postoperative toxicity, we recommend caution when pursuing surgery, especially with vascular resection after SMART. Additional follow-up is ongoing to evaluate late toxicity, quality of life, and long-term efficacy.


Assuntos
Neoplasias Pancreáticas , Radiocirurgia , Humanos , Idoso , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/tratamento farmacológico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Estudos Prospectivos , Planejamento da Radioterapia Assistida por Computador , Qualidade de Vida , Pâncreas , Espectroscopia de Ressonância Magnética , Radiocirurgia/métodos , Neoplasias Pancreáticas
11.
J Clin Med ; 11(5)2022 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-35268279

RESUMO

With the implementation of MR-LINACs, real-time adaptive radiotherapy has become a possibility within the clinic. However, the process of adapting a patient's plan is time consuming and often requires input from the entire clinical team, which translates to decreased throughput and limited patient access. In this study, the authors propose and simulate a workflow to address these inefficiencies in staffing and patient throughput. Two physicians, three radiation therapists (RTT), and a research fellow each adapted bladder and bowel contours for 20 fractions from 10 representative patient plans. Contouring ability was compared via calculation of a Dice Similarity Index (DSI). The DSI for bladder and bowel based on each potential physician-therapist pair, as well as an inter-physician comparison, exhibited good overlap amongst all comparisons (p = 0.868). Plan quality was compared through calculation of the conformity index (CI), as well as an evaluation of the plan's dose to a 'gold standard' set of structures. Overall, non-physician plans passed 91.2% of the time. Of the eight non-physician plans that failed their clinical evaluation, six also failed their evaluation against the 'gold standard'. Another two plans that passed their clinical evaluation subsequently failed in their evaluation against the 'gold standard'. Thus, the PF-ROAR process has a success rate of 97.5%, with 78/80 plans correctly adapted to the gold standard or halted at treatment. These findings suggest that a physician-free workflow can be well tolerated provided RTTs continue to develop knowledge of MR anatomy and careful attention is given to understanding the complexity of the plan prior to treatment.

12.
J Appl Clin Med Phys ; 12(4): 3590, 2011 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-22089017

RESUMO

In the past 10 years, techniques to improve radiotherapy delivery, such as intensity-modulated radiation therapy (IMRT), image-guided radiation therapy (IGRT) for both inter- and intrafraction tumor localization, and hypofractionated delivery techniques such as stereotactic body radiation therapy (SBRT), have evolved tremendously. This review article focuses on only one part of that evolution, electromagnetic tracking in radiation therapy. Electromagnetic tracking is still a growing technology in radiation oncology and, as such, the clinical applications are limited, the expense is high, and the reimbursement is insufficient to cover these costs. At the same time, current experience with electromagnetic tracking applied to various clinical tumor sites indicates that the potential benefits of electromagnetic tracking could be significant for patients receiving radiation therapy. Daily use of these tracking systems is minimally invasive and delivers no additional ionizing radiation to the patient, and these systems can provide explicit tumor motion data. Although there are a number of technical and fiscal issues that need to be addressed, electromagnetic tracking systems are expected to play a continued role in improving the precision of radiation delivery.


Assuntos
Neoplasias/radioterapia , Radioterapia de Intensidade Modulada/métodos , Fenômenos Eletromagnéticos , Humanos
13.
JCO Oncol Pract ; 17(12): e1949-e1957, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34460290

RESUMO

PURPOSE: An episode-based payment model, the Radiation Oncology Alternative Payment Model (RO-APM), is scheduled to go into effect in January 2022. This article investigates the effects of RO-APM on hospital-based and freestanding community centers. METHODS: Historical Medicare data used to generate the RO-APM base rates were reviewed. A sensitivity analysis was performed to show how the RO-APM reimbursements compare with current reimbursements for commonly accepted treatment schedules and with current reimbursements at a large community practice. RESULTS: The RO-APM base rates represent a 2.2% decrease in overall Medicare reimbursement. Freestanding centers have historically billed at higher rates than hospital-based centers, however, and the RO-APM base rates represent a 6% decrease in global reimbursement for freestanding centers. The sensitivity analysis showed that, except for proton therapy, moderately hypofractionated treatment schedules will receive comparable reimbursement under RO-APM. Treatments using higher numbers of fractions of intensity-modulated radiation therapy or protons will see larger decreases in reimbursement. Application of the RO-APM base rates to the 2020 Medicare treatments in our health care network would result in small changes in expected reimbursement, but our sensitivity analysis indicated that Medicare reimbursement reductions could be as large as 23%. CONCLUSION: Compared with historical Medicare reimbursement, RO-APM base rates provide lower reimbursement for many common treatment scenarios, and this will have a larger effect on centers that use complex treatment techniques and longer fractionation schedules or have a large Medicare population.


Assuntos
Neoplasias , Radioterapia (Especialidade) , Idoso , Atenção à Saúde , Humanos , Oncologia , Medicare , Neoplasias/radioterapia , Estados Unidos
14.
Med Dosim ; 46(3): 264-268, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33771435

RESUMO

The purpose of this work was to evaluate using Varian HyperArc as a planning and treatment solution for whole brain radiotherapy (WBRT) with hippocampal sparing following Radiation Therapy Oncology Group (RTOG) 0933 dosimetric criteria. Ten patients previously treated for intracranial lesions were retrospectively planned for WBRT with hippocampal sparing using HyperArc and a 2-arc coplanar VMAT technique. The whole brain and hippocampus were delineated on fused MRI and CT datasets. The planning target volume (PTV), defined as the whole brain excluding the hippocampal avoidance region, was prescribed 30 Gy in 10 fractions. Plans were evaluated using dosimetric parameters which included the volume of 105% of the prescription dose (V105%) and the maximum dose to the PTV, and the minimum dose to the hippocampus. The planning time, delivery time, and delivery quality assurance (QA) results were also evaluated. Statistical significance was performed between the HyperArc and coplanar VMAT metrics using the Wilcoxon signed-rank test with a significance level of 0.05. All plans met RTOG 0933 dosimetric criteria. HyperArc plans demonstrated significant improvements in PTV dosimetric quality which included a reduced V105% of 6 ± 7% and decreased maximum dose of 1.3 ± 0.3 Gy, compared to coplanar VMAT. Significant OAR sparing was also found for HyperArc plans that included a decreased minimum dose to the hippocampus of 0.3 ± 0.3 Gy. Coplanar VMAT plans resulted in significantly shorter planning and delivery times, compared to HyperArc, by 2.4 minutes and 1.5 minutes, respectively. No significant difference was found between the delivery QA results. This study demonstrated using Varian HyperArc as a planning and treatment solution for WBRT with hippocampal sparing following RTOG 0933 dosimetric criteria. The primary advantages of WBRT with hippocampal sparing using HyperArc, compared to coplanar VMAT, are the gains in OAR sparing and reduced high dose volumes to the PTV.


Assuntos
Neoplasias Encefálicas , Radioterapia de Intensidade Modulada , Encéfalo , Neoplasias Encefálicas/radioterapia , Hipocampo , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
15.
JCO Oncol Pract ; 17(12): e1943-e1948, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33170747

RESUMO

PURPOSE: An episode-based payment model, the Radiation Oncology Alternative Payment Model (RO-APM), has been proposed for Medicare reimbursement of radiation services provided to oncology patients. RO-APM may have significant impact on reimbursement for specific patient populations. METHODS: This investigation compares historical fee-for-service technical reimbursement estimates at a large hospital-based system to the RO-APM for advanced radiotherapy treatment of specific cancer types. These advanced techniques, stereotactic radiosurgery (SRS), stereotactic body radiotherapy (SBRT), online-adaptive SBRT, and proton therapy, were specifically chosen because they are resource intensive and are correspondingly among the most expensive radiation oncology procedures. A total of 203 Medicare patients were analyzed. RESULTS: RO-APM base-rate reimbursements were similar for SRS and were 38%-47% higher for SBRT. The proposed rates were 1%-31% lower for online-adaptive SBRT, and 48%-71% lower for proton therapy. CONCLUSION: These data suggest that the RO-APM may have the desired effect of encouraging shorter courses of radiotherapy, such as SBRT. However, emerging technologies that require large capital and operating investments may see an overall significant reduction in proposed reimbursement.


Assuntos
Neoplasias , Terapia com Prótons , Radioterapia (Especialidade) , Radiocirurgia , Idoso , Humanos , Medicare , Neoplasias/radioterapia , Estados Unidos
16.
J Radiosurg SBRT ; 7(2): 149-156, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33282468

RESUMO

Commercial systems such as Varian HyperArcTM and BrainLab Elements MultiMetTM have been developed that allow radiosurgery treatment of multiple brain metastases using a single isocenter. Each software package places increased demands on frameless immobilization and requires the use of a specific immobilization system: the QFix-Encompass system for Varian and the BrainLab frameless-mask system for BrainLab. At our institution, patients receiving traditional radiosurgery (one isocenter per target lesion) were treated using both immobilization systems. Intrafraction motion was determined for each patient using multiple cone-beam CT scans and the same image-registration software during treatment. There were no statistically-significant differences in mean absolute translational shifts between the two mask systems, with a mean 3D-vector motion of approximately 0.43 mm for both systems. There were also no statistically-significant differences in the mean absolute rotational shifts between the two mask systems. Although the average residual errors were insignificant between the mask systems, special attention should be paid to individual maximum shifts with both systems. Large maximum rotational misalignments could present significant misalignment of lesions as distance increases from the isocenter. Finally, large maximum shifts highlight the need for real-time monitoring of patient movement during radiosurgery of multiple lesions using a single isocenter.

17.
Pract Radiat Oncol ; 10(5): e425-e431, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32004703

RESUMO

PURPOSE: Treating critically ill patients in radiation oncology departments poses multiple safety risks. This study describes a method to improve the speed of radiation treatment for patients in the intensive care unit by eliminating the need for computed tomography (CT) simulation or on-table treatment planning using patients' previously acquired diagnostic CT scans. METHODS AND MATERIALS: Initially, a retrospective planning study was performed to assess the applicability and safety of diagnostic scan-based planning (DSBP) for 3 typical indications for radiation therapy in patients in the intensive care unit: heterotopic ossification (10), spine metastases (cord compression; 10), and obstructive lung lesions (5). After identification of an appropriate diagnostic CT scan, treatment planning was performed using the diagnostic scan data set. These treatment plans were then transferred to the patients' simulation scans, and a dosimetric comparison was performed between the 2 sets of plans. Additionally, a time study of the first 10 patients treated with DSBP in our department was performed. RESULTS: The retrospective analysis demonstrated that DSBP resulted in treatment plans that, when transferred to the CT simulation data sets, provided excellent target coverage, a median D95% of 96% (range, 86%-100%) of the prescription dose with acceptable hot spots, and a median Dmax108% (range, 102%-113%). Subsequently, DSBP has been used for 10 critically ill patients. The patients were treated without CT simulation, and the median time between patient check-in to the department and completion of radiation therapy was 28 minutes (range, 18-47 minutes.) CONCLUSIONS: This study demonstrates that it is possible to safely use DSBP for the treatment of critically ill patients. This method has the potential to simplify the treatment process and improve the speed and safety of treatment.


Assuntos
Estado Terminal , Humanos , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
18.
Technol Cancer Res Treat ; 8(2): 123-30, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19334793

RESUMO

Initial results of megavoltage computed tomography (MVCT) brachytherapy treatment planning are presented, using a commercially available helical tomotherapy treatment unit and standard low dose rate (LDR) brachytherapy applicators used for treatment of cervical carcinoma. The accuracy of MVCT imaging techniques, and dosimetric accuracy of the CT based plans were tested with in-house and commercially-available phantoms. Three dimensional (3D) dose distributions were computed and compared to the two dimensional (2D) dosimetry results. Minimal doses received by the 2 cm3 of bladder and rectum receiving the highest doses (D(B2cc) and D(R2cc), respectively) were computed from dose-volume histograms and compared to the doses computed for the standard ICRU bladder and rectal reference dose points. Phantom test objects in MVCT image sets were localized with sub-millimetric accuracy, and the accuracy of the MVCT-based dose calculation was verified. Fifteen brachytherapy insertions were also analyzed. The ICRU rectal point dose did not differ significantly from D(R2cc) (p=0.749, mean difference was 24 cGy +/- 283 cGy). The ICRU bladder point dose was significantly lower than the D(B2cc) (p=0.024, mean difference was 291 cGy +/- 444 cGy). The median volumes of bladder and rectum receiving at least the corresponding ICRU reference point dose were 6.1 cm(3) and 2.0 cm(3), respectively. Our initial experience in using MVCT imaging for clinical LDR gynecological brachytherapy indicates that the MVCT images are of sufficient quality for use in 3D, MVCT-based dose planning.


Assuntos
Braquiterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero/radioterapia , Feminino , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Reto/efeitos da radiação , Bexiga Urinária/efeitos da radiação
19.
Int J Radiat Oncol Biol Phys ; 70(5): 1579-87, 2008 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-18234438

RESUMO

PURPOSE: Megavoltage computed tomography (MVCT) can be used daily for imaging with a helical tomotherapy unit for patient alignment before treatment delivery. The purpose of this investigation was to show that the MVCT dose can be computed in phantoms, and further, that the dose can be reported for actual patients from MVCT on a helical tomotherapy unit. METHODS AND MATERIALS: An MVCT beam model was commissioned and verified through a series of absorbed dose measurements in phantoms. This model was then used to retrospectively calculate the imaging doses to the patients. The MVCT dose was computed for five clinical cases: prostate, breast, head/neck, lung, and craniospinal axis. RESULTS: Validation measurements in phantoms verified that the computed dose can be reported to within 5% of the measured dose delivered at the helical tomotherapy unit. The imaging dose scaled inversely with changes to the CT pitch. Relative to a normal pitch of 2.0, the organ dose can be scaled by 0.67 and 2.0 for scans done with a pitch of 3.0 and 1.0, respectively. Typical doses were in the range of 1.0-2.0 cGy, if imaged with a normal pitch. The maximal organ dose calculated was 3.6 cGy in the neck region of the craniospinal patient, if imaged with a pitch of 1.0. CONCLUSION: Calculation of the MVCT dose has shown that the typical imaging dose is approximately 1.5 cGy per image. The uniform MVCT dose delivered using helical tomotherapy is greatest when the anatomic thickness is the smallest and the pitch is set to the lowest value.


Assuntos
Doses de Radiação , Tomografia Computadorizada Espiral , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Feminino , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Imagens de Fantasmas , Neoplasias da Próstata/diagnóstico por imagem , Radiometria , Estudos Retrospectivos , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada Espiral/instrumentação
20.
Adv Radiat Oncol ; 2(3): 494-502, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29114618

RESUMO

PURPOSE: To characterize the accuracy of noncoplanar image guided radiation therapy with the Varian Edge radiosurgery system for intracranial stereotactic radiosurgery (SRS) treatments by assessing the accuracy of kV/kV orthogonal pair registration with Optical Surface Monitoring System (OSMS) monitoring relative to cone beam computed tomography (CT). METHODS AND MATERIALS: A Computerized Imaging Reference System head phantom and Encompass SRS Immobilization System were used to determine collision-free space for orthogonal image pairs (kV/kV) for couch rotations (CRs) of 45°, 30°, 15°, 345°, 330°, and 315°. Couch-induced shifts were measured using kV/kV orthogonal image pairs, OSMS, and cone beam CT. The kV/kV image pairs and OSMS localization accuracy was also assessed with respect to cone beam CT. RESULTS: Mean orthogonal image pair differences for 315°, 330°, 345°, 15°, 30°, and 45° CRs were ≤±0.60 mm and ±0.37°. OSMS localization accuracy was ≤±0.25 mm and ±0.20°. Correspondingly, kV/kV localization accuracy was ≤±0.30 mm and ±0.5°. Shift differences for various image pairs at all CRs were ≤±1.10 mm and ±0.7°. Cone beam CT deviation was 0.10 mm and 0.00° without patient motion or CR. CONCLUSION: Based on our study, CR-induced shifts with the Varian Edge radiosurgery system will not produce noticeable dosimetric effects for SRS treatments. Thus, replacing cone beam CT with orthogonal kV/kV pairs coupled with OSMS at the treatment couch angle could reduce the number of cone beam CT scans that are acquired during a standard SRS treatment while providing an accurate and safe treatment with negligible dosimetric effects on the treatment plan.