Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Hyperthermia ; 28(2): 175-83, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22335231

RESUMO

PURPOSE: To design and test a wideband multi-channel amplifier system for time reversal (TR) microwave hyperthermia, operating in the frequency range 300 MHz-1 GHz, enabling operation in both pulsed and continuous wave regimes. This is to experimentally verify that adaptation of the heating pattern with respect to tumour size can be realised by varying the operating frequency of the antennas and potentially by using Ultra-wideband (UWB) pulse sequences instead of pure harmonic signals. MATERIALS AND METHODS: The proposed system consists of 12 identical channels driven by a common reference signal. The power and phase settings are applied with resolutions of 0.1 W and 0.1°, respectively. Using a calibration procedure, the measured output characteristics of each channel are interpolated using polynomial functions, which are then implemented into a system software algorithm driving the system feedback loop. RESULTS: The maximum output power capability of the system varies with frequency, between 90 and 135 W with a relative power error of ± 6%. A phase error in the order of ± 4° has been achieved within the entire frequency band. CONCLUSIONS: The developed amplifier system prototype is capable of accurate power and phase delivery, over the entire frequency band of the system. The output power of the present system allows for an experimental verification of a recently developed TR-method on phantoms or animals. The system is suitable for further development for head and neck tumours, breast or extremity applications.


Assuntos
Amplificadores Eletrônicos , Hipertermia Induzida/instrumentação , Animais , Desenho de Equipamento , Hipertermia Induzida/métodos , Micro-Ondas , Software
2.
Basic Clin Neurosci ; 4(1): 31-5, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-25337325

RESUMO

INTRODUCTION: Ciprofloxacin which was used in this study is a Fluoroquinolone (FQ). This kind of drug may cause epileptic seizures probably because of the inhibition of GABA binding to its receptors. Wag/Rij rats (an animal model for generalized absence epilepsy), were used as experimental subjects. METHODS: For EEG study, electrodes were inserted into the cortex of animals according to paxinos coordinates. After and before ciprofloxacin injection, EEG was recorded and their SWDs were compared with each others. RESULTS: Findings showed a significant increase in the mean number of seizures during recording period. But the mean number of SWDs during seizures did not show any significant differences between groups. DISCUSSION: These results may be due to involvement of GABA antagonistic effects of FQs and/or Mg2+ linked blockade of NMDA receptors. More researches are going to determine physiopathology of SWDs and find new effective substance against this kind of epilepsy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA