1.
J Robot Surg ; 18(1): 268, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38922454

RESUMO

Robotic-assisted surgery emerged as a technological advancement in the twentieth century, with gynaecology being a key adopter of this approach. The Senhance Surgical System has gained prominence for total hysterectomies from single-site experiences, but multi-site reporting are still lacking in present literature. This multi-site study, conducted at Klaipeda University Hospital and Academic Teaching Hospital Feldkirch, aimed to explore the safety and feasibility of total hysterectomies with the Senhance Surgical System. The study involved 295 cases, showcasing a well-established routine with minimal procedure times. The average age of the patients was 53.5 years (SD: 10.3 years), ranging from 18 to 80 years. The patients' BMI averaged 25.6 kg/m2 (SD: 6.2 kg/m2), ranging from a minimum of 17.7 kg/m2 to a maximum of 69.5 kg/m2. The duration of surgery varied between 30 and 215 min, with a median of 95 min (IQR: 81-116). The docking time was a median of 3 (IQR: 2-5) min and varied between 1.0 and 30.0 min, with a minimum to a maximum range of 1.0 to 122 min. Conversion (3 cases, 1%) and adverse events (6 cases, 2%) were infrequent. Additionally, robotic malfunctions were recorded minimally in 4,1% (12 cases) of the procedures, and pain on a 0-10 visual pain scale was reduced from mild [2.7 (± 1.2)] one day postoperative to minimal [0.9 (± 0.5)] at discharge. Overall, a great routine with the Senhance Surgical System proves good control and, thus, feasibility and safety. Therefore, the Senhance Surgical System is a viable option for total hysterectomy.


Assuntos
Estudos de Viabilidade , Histerectomia , Duração da Cirurgia , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/estatística & dados numéricos , Feminino , Pessoa de Meia-Idade , Histerectomia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Adolescente , Adulto Jovem
2.
J Robot Surg ; 18(1): 94, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38413542

RESUMO

Robotic surgery is on its way to revolutionizing traditional surgical procedures, offering precise and minimally invasive techniques hypothesized to shorten recovery times and improve patient outcomes. While there have been multiple publications on robotic systems' medical and procedural achievements, more emphasis should be put on the surgeon's experience, especially in comparison with laparoscopic surgery. The present report aims to systematically examine the stress impact on surgeons by comparing the robotic Senhance Surgical System (Asensus Surgical, Durham, North Carolina, U.S.A) to laparoscopic surgery. The well-established "SURG-TLX" survey is used to measure distinct stress entities. The "SURG-TLX" survey is a modified version of the NASA-TLX, validated for surgery by M. Willson. Based on a comprehensive database from six centers encompassing various disciplines and surgical procedures, our analysis indicates significantly reduced "overall stress" levels for robotic (cockpit) compared to laparoscopic surgeons. Exploring the "SURG-TLX" stress dimensions further between methods (robotic vs. laparoscopic) and surgeon position (laparoscopic, (robotic) bedside, or (robotic) cockpit) resulted in significantly more Mental (p.value < 0.015), less Physical Demands (p.value < 0.001) and less Distraction (p.value < 0.009) for robotic surgery, especially regarding the robotic cockpit surgeons. This finding suggests that robotic surgery with the Senhance Surgical System contributes to a favorable stress profile for surgeons, potentially enhancing their overall well-being and performance.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Cirurgiões , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Inquéritos e Questionários
3.
J Gynecol Obstet Hum Reprod ; 50(1): 102031, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33253905

RESUMO

OBJECTIVE: In this article, we present the first 100 gynaecological robotic surgeries in Klaipeda University Hospital, Klaipeda, Lithuania. STUDY DESIGN: A prospective analysis was performed of 100 women age range 22-82, on average 52 years. Patients underwent various robotic gynaecological operations, 61 (61 %) procedures were robotic total hysterectomy with bilateral salpingo-oophorectomy. RESULTS: Duration of the surgery varied from 30 min to 185 min, on average 99 ± 33 min. Of all 25 (25 %) patients had operations in the past. Most operations (72 %) were performed for benign diseases and 28 % of the patients were operated for various types of gynaecological malignancies. All cancer surgeries were radical (R0). In-hospital stay was on average 4 ± 2.3 days, range 1-14 days. There were six (6%) conversions: one to laparoscopy and five to open. Three (3%) complications occurred during 30 days after surgery, one demanded surgery (Clavien-Dindo II-IIIb). There was no mortality in this patient population. CONCLUSION: Our early experience with different types of robotic gynaecological surgeries allows us to state that Senhance® robotic system is feasible and safe in gynaecology.


Assuntos
Procedimentos Cirúrgicos em Ginecologia , Procedimentos Cirúrgicos Robóticos , Adulto , Idoso , Idoso de 80 Anos ou mais , Conversão para Cirurgia Aberta , Feminino , Humanos , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias , Estudos Prospectivos , Adulto Jovem
4.
J Robot Surg ; 14(2): 371-376, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31301021

RESUMO

Until recently, robotic surgery has been associated only with the da Vinci robotic system. A novel Senhance® robotic system (TransEnterix Surgical Inc., Morrisville, NC, USA) was introduced almost 5 years ago. Published reports on experience using this robotic platform are very limited. We present a prospective analysis of the first 100 robotic surgeries in abdominal surgery, gynecology, and urology in Klaipeda University Hospital, Klaipeda, Lithuania. Out of 100 operated patients during the mentioned period, 49 were female and 51 men, age range 27-79 years, on an average 55 years. 39 underwent robotic abdominal surgical procedures, 31-urological, and 30 gynecological surgeries. Duration of surgery varied from 30 min to 6 h and 5 min, on an average 2 h 25 min. Almost half 49 (49%) were operated on for malignant diseases: prostate cancer-27, renal cell carcinoma-1, endometrial cancer-7, ovarian cancer-1, colorectal cancer-13 (7 colon and 6 rectum). In-hospital stay was on an average 4 days, range 1-15 days. There were 3 (3%) conversions: two to laparoscopy (both undergoing robotic radical prostatectomy) and one to open (undergoing total hysterectomy). 6 (6%) complications occurred during 30 postoperative days, 2 demanding surgery. According to the Clavien-Dido classification, they were grade II in 3, grade III a in 1 and grade III b in 2 cases. There was no mortality in this patient population. Our experience with different types of robotic surgeries allows us to state that the Senhance® robotic system is feasible and safe in general surgery, gynecology, and urology, and wider implementation of this system worldwide is simply a question of time.


Assuntos
Procedimentos Cirúrgicos Robóticos/instrumentação , Adulto , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/métodos , Segurança