Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Drug Metab Lett ; 10(4): 286-294, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28093968

RESUMO

OBJECTIVE: We developed a simple and validated liquid chromatography tandem mass spectrometry( LC-MS/MS) for quantification of etodolac using pioglitazone as an internal standard (IS) to assess pharmacokinetics and to appraise bioequivalence of two formulations of etodolac (reference and tested) in 27 healthy Korean subjects. METHODS: Isocratic mobile phase consisted of 10 mM ammonium formate and acetonitrile were used to separate the analytes on a Gemini C18 column. Also, analytes were analyzed by MS/MS in multiple reaction monitoring (MRM) mode using the transitions of (M+H)+ ions, m/z 288.2→ 172.3 and m/z 357.1→ 134.2 for quantification of etodolac and IS each. The standard calibration curves displayed significant linearity within the range of 0.2-30.0 µ g/mL (r2=0.9956, 1/x2 weighting) with LLOQ of 0.1 µg/mL. RESULTS: The retention times of etodolac and the IS were 0.77 min and 0.57 min each, indicating the high-throughput potential of the proposed method. The pharmacokinetic parameters were calculated from the plasma samples and data form the reference and test drugs were represented as follows; Area under plasma concentration-time curve (AUCt) (78.03 vs. 84.00 µgxh/mL), AUC∞ (86.67 vs. 93.92 µgxh/mL), maximal plasma concentration (Cmax) (19.49 vs. 18.94 µg/mL), time for maximal concentrations (Tmax) (2.13 vs. 2.26 h), Plasma elimination half-life (T1/2) (8.12 vs. 8.47 h), elimination rate constant (λz) (0.0853 vs. 0.0818 h-1). Pharmacokinetic parameters with 90% confidence interval fall within the bioequivalence range of 80-125%. CONCLUSION: Thus, the new testified method was successfully applied for the pharmacokinetic and bioequivalence studies for two etodolac formulations.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Inibidores de Ciclo-Oxigenase 2/farmacocinética , Etodolac/farmacocinética , Espectrometria de Massas em Tandem/métodos , Adulto , Área Sob a Curva , Calibragem , Cromatografia Líquida de Alta Pressão/instrumentação , Estudos Cross-Over , Inibidores de Ciclo-Oxigenase 2/sangue , Etodolac/sangue , Meia-Vida , Voluntários Saudáveis , Humanos , Masculino , Distribuição Aleatória , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/instrumentação , Equivalência Terapêutica , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA