Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
2.
Eur J Radiol ; 131: 109257, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32947092

RESUMO

PURPOSE: To compare a zoomed EPI-DWI (z-EPI) with a standard EPI-DWI (s-EPI) in the primary diagnostics of rectal cancer and assess its potential of reduced image artifacts. METHOD: 22 therapy-naïve patients with rectal cancer underwent rectal MRI at a 3 T-system. The protocols consisted of a z-EPI DWI and s-EPI DWI sequence. Images were assessed by two independent and experienced readers regarding overall image quality and artifacts on a 5-point Likert scale, as well as overall sequence preference. In a lesion-based analysis, tumor and lymph node detection were rated on a 4-point Likert scale. Apparent diffusion coefficient (ADC) measurements were performed. RESULTS: Overall Image quality score for z-EPI and s-EPI showed no statistically significant differences (p = 0.80/0.54, reader 1/2) with a median score of 4 ("good" image quality) for both sequences. The image quality preference rank for z-EPI and s-EPI was given the category 'no preference' in 64 % (reader 1) and 50 % (reader 2). Most artifact-related scores (susceptibility, motion and distortion) did not show reproducible significant differences between z-EPI and s-EPI. The two sequences exhibited comparable, mostly good and excellent quality scores for tumor and lymph node detection (p = 0.19-0.99). ADC values were significantly lower for z-EPI than for s-EPI (p = 0.001/0.002, reader 1/2) with good agreement of ADC measurements between both readers. CONCLUSION: Our data showed comparable image quality and lesion detection for the z-EPI and the s-EPI sequence in MRI of rectal cancer, whereas the mean ADC of the tumor was significantly lower in z-EPI compared to s-EPI.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Imageamento Tridimensional/métodos , Neoplasias Retais/diagnóstico por imagem , Adulto , Idoso , Artefatos , Feminino , Humanos , Aumento da Imagem , Linfonodos/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
3.
Phys Med Biol ; 61(24): 8736-8749, 2016 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-27893446

RESUMO

This study aimed to identify a set of stable radiomic parameters in CT perfusion (CTP) maps with respect to CTP calculation factors and image discretization, as an input for future prognostic models for local tumor response to chemo-radiotherapy. Pre-treatment CTP images of eleven patients with oropharyngeal carcinoma and eleven patients with non-small cell lung cancer (NSCLC) were analyzed. 315 radiomic parameters were studied per perfusion map (blood volume, blood flow and mean transit time). Radiomics robustness was investigated regarding the potentially standardizable (image discretization method, Hounsfield unit (HU) threshold, voxel size and temporal resolution) and non-standardizable (artery contouring and noise threshold) perfusion calculation factors using the intraclass correlation (ICC). To gain added value for our model radiomic parameters correlated with tumor volume, a well-known predictive factor for local tumor response to chemo-radiotherapy, were excluded from the analysis. The remaining stable radiomic parameters were grouped according to inter-parameter Spearman correlations and for each group the parameter with the highest ICC was included in the final set. The acceptance level was 0.9 and 0.7 for the ICC and correlation, respectively. The image discretization method using fixed number of bins or fixed intervals gave a similar number of stable radiomic parameters (around 40%). The potentially standardizable factors introduced more variability into radiomic parameters than the non-standardizable ones with 56-98% and 43-58% instability rates, respectively. The highest variability was observed for voxel size (instability rate >97% for both patient cohorts). Without standardization of CTP calculation factors none of the studied radiomic parameters were stable. After standardization with respect to non-standardizable factors ten radiomic parameters were stable for both patient cohorts after correction for inter-parameter correlations. Voxel size, image discretization, HU threshold and temporal resolution have to be standardized to build a reliable predictive model based on CTP radiomics analysis.


Assuntos
Imagem de Perfusão/métodos , Tomografia Computadorizada por Raios X/métodos , Volume Sanguíneo , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/fisiopatologia , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/fisiopatologia , Neoplasias Orofaríngeas/diagnóstico por imagem , Neoplasias Orofaríngeas/patologia , Neoplasias Orofaríngeas/fisiopatologia , Prognóstico , Carga Tumoral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA